{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T07:29:07Z","timestamp":1740122947328,"version":"3.37.3"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2023,9,28]],"date-time":"2023-09-28T00:00:00Z","timestamp":1695859200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,9,28]],"date-time":"2023-09-28T00:00:00Z","timestamp":1695859200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Multimed Tools Appl"],"DOI":"10.1007\/s11042-023-16961-y","type":"journal-article","created":{"date-parts":[[2023,9,28]],"date-time":"2023-09-28T09:01:43Z","timestamp":1695891703000},"page":"35979-35993","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Repeatability and reproducibility of landmark localization on panoramic images for PA (Posteroanterior) cephalometric analysis"],"prefix":"10.1007","volume":"83","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8592-9964","authenticated-orcid":false,"given":"Abhishek","family":"Gupta","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9513-329X","authenticated-orcid":false,"given":"Shailendra Singh","family":"Rana","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arshad","family":"Eranhikkal","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9988-0236","authenticated-orcid":false,"given":"Prashant","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,9,28]]},"reference":[{"key":"16961_CR1","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1007\/s00056-004-0331-1","volume":"65","author":"U Hirschfelder","year":"2004","unstructured":"Hirschfelder U, Piechot E, Schulte M, Leher A (2004) Abnormalities of the TMJ and the musculature in the oculo-auriculo-vertebral spectrum (OAV). A CT study. J Orofac Orthop 65:204\u2013216","journal-title":"J Orofac Orthop"},{"key":"16961_CR2","doi-asserted-by":"crossref","unstructured":"Gupta A (2023) On imaging modalities for cephalometric analysis: a review. Multimed Tools Appl","DOI":"10.1007\/s11042-023-14971-4"},{"key":"16961_CR3","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1016\/0889-5406(91)70045-X","volume":"100","author":"W Schmid","year":"1991","unstructured":"Schmid W, Mongini F, Felisio A (1991) A computer-based assessment of structural and displacement asymmetries of the mandible. Am J Orthod Dentofac Orthop 100:19\u201334","journal-title":"Am J Orthod Dentofac Orthop"},{"issue":"214","key":"16961_CR4","first-page":"26","volume":"51","author":"FS Chebib","year":"1981","unstructured":"Chebib FS, Chamma AM (1981) Indices of craniofacial asymmetry. Angle Orthod 51(214):26","journal-title":"Angle Orthod"},{"key":"16961_CR5","first-page":"448","volume":"21","author":"DC Grummons","year":"1987","unstructured":"Grummons DC, Kappeyne van de Coppello MA (1987) Frontal asymmetry analysis. J Clin Orthod 21:448\u201365","journal-title":"J Clin Orthod"},{"key":"16961_CR6","first-page":"297","volume":"4","author":"RM Ricketts","year":"2003","unstructured":"Ricketts RM, Grummons D (2003) Frontal cephalometrics: practical applications, part 1. World J Orthod 4:297\u2013316","journal-title":"World J Orthod"},{"issue":"2","key":"16961_CR7","first-page":"99","volume":"5","author":"D Grummons","year":"2004","unstructured":"Grummons D, Ricketts RM (2004) Frontal cephalometrics: practical applications, part 2. World J Orthod 5(2):99\u2013119","journal-title":"World J Orthod"},{"key":"16961_CR8","doi-asserted-by":"publisher","first-page":"208","DOI":"10.1597\/02-112","volume":"41","author":"N Kitai","year":"2004","unstructured":"Kitai N et al (2004) Craniofacial morphology in an unusual case with nasal aplasia studied by roentgencephalometry and three-dimensional CT scanning. Cleft Palate Craniofac J 41:208\u2013213","journal-title":"Cleft Palate Craniofac J"},{"key":"16961_CR9","doi-asserted-by":"publisher","first-page":"779","DOI":"10.1016\/j.ajodo.2005.02.021","volume":"130","author":"H-S Hwang","year":"2006","unstructured":"Hwang H-S, Hwang CH, Lee K-H, Kang B-C (2006) Maxillofacial 3-dimensional image analysis for the diagnosis of facial asymmetry. Am J Orthod Dentofac Orthop 130:779\u2013785","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"16961_CR10","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1016\/0030-4220(81)90369-8","volume":"52","author":"WD McDavid","year":"1981","unstructured":"McDavid WD, Tronje G, Welander U, Morris CR (1981) Effects of errors in film speed and beam alignment on the image layer in rotational panoramic radiography. Oral Surg Oral Med Oral Pathol 52:561\u2013564","journal-title":"Oral Surg Oral Med Oral Pathol"},{"key":"16961_CR11","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1016\/S1073-8746(98)80004-2","volume":"4","author":"B Friedland","year":"1998","unstructured":"Friedland B (1998) Clinical radiological issues in orthodontic practice. Semin Orthod 4:64\u201378","journal-title":"Semin Orthod"},{"key":"16961_CR12","first-page":"92","volume":"18","author":"DK Yeo","year":"2002","unstructured":"Yeo DK, Freer TJ, Brockhurst PJ (2002) Distortions in panoramic radiographs. Aust Orthod J 18:92\u201398","journal-title":"Aust Orthod J"},{"key":"16961_CR13","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1093\/ejo\/cjq190","volume":"34","author":"I Titiz","year":"2012","unstructured":"Titiz I, Laubinger M, Keller T, Hertrich K, Hirschfelder U (2012) Repeatability and reproducibility of landmarks\u2014a three-dimensional computed tomography study. Eur J Orthod 34:276\u2013286","journal-title":"Eur J Orthod"},{"key":"16961_CR14","doi-asserted-by":"publisher","first-page":"41869","DOI":"10.1007\/s11042-021-11609-1","volume":"81","author":"A Gupta","year":"2022","unstructured":"Gupta A (2022) RegCal: registration-based calibration method to perform linear measurements on PA (posteroanterior) cephalogram- a pilot study. Multimed Tools Appl 81:41869\u201341879.\u00a0https:\/\/doi.org\/10.1007\/s11042-021-11609-1","journal-title":"Multimed Tools Appl"},{"key":"16961_CR15","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1016\/j.tripleo.2008.05.039","volume":"107","author":"AE De Oliveira","year":"2009","unstructured":"De Oliveira AE, Cevidanes LH, Phillips C, Motta A, Burke B, Tyndall D (2009) Observer reliability of three-dimensional cephalometric landmark identification on cone-beam computerized tomography. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 107:256\u2013265","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"issue":"3","key":"16961_CR16","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1093\/ejo\/8.3.149","volume":"8","author":"WJ Houston","year":"1986","unstructured":"Houston WJ, Maher RE, McElroy D, Sherriff M (1986) Sources of error in measurements from cephalometric radiographs. Eur J Orthod 8(3):149\u2013151","journal-title":"Eur J Orthod"},{"issue":"2","key":"16961_CR17","first-page":"98","volume":"10","author":"AM Vincent","year":"1987","unstructured":"Vincent AM, West VC (1987) Cephalometric landmark identification error. Aust Orthod J 10(2):98\u2013104","journal-title":"Aust Orthod J"},{"key":"16961_CR18","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1016\/j.tripleo.2008.09.025","volume":"107","author":"JW Chadwick","year":"2009","unstructured":"Chadwick JW, Prentice RN, Major PW, Lam EW (2009) Image distortion and magnification of 3 digital CCD cephalometric systems. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 107:105\u2013112","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"16961_CR19","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1067\/mod.2002.129191","volume":"122","author":"RK Schulze","year":"2002","unstructured":"Schulze RK, Gloede MB, Doll GM (2002) Landmark identification on direct digital versus film-based cephalometric radiographs: a human skull study. Am J Orthod Dentofacial Orthop 122:635\u2013642","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"16961_CR20","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1016\/j.ajodo.2016.06.027","volume":"151","author":"A Gupta","year":"2017","unstructured":"Gupta A, Kharbanda OP, Balachandran R, Sardana V, Kalra S, Chaurasia S et al (2017) Precision of manual landmark identification between as-received and oriented volume-rendered cone-beam computed tomography images. Am J Orthod Dentofac Orthop 151:118\u2013131","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"16961_CR21","doi-asserted-by":"publisher","first-page":"1737","DOI":"10.1007\/s11548-015-1173-6","volume":"10","author":"A Gupta","year":"2015","unstructured":"Gupta A, Kharbanda O, Sardana V, Balachandran R, Sardana H (2015) A knowledge-based algorithm for automatic detection of cephalometric landmarks on CBCT images. Int J Comput Assist Radiol Surg 10:1737\u20131752","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"16961_CR22","doi-asserted-by":"publisher","first-page":"1297","DOI":"10.1007\/s11548-015-1334-7","volume":"11","author":"A Gupta","year":"2016","unstructured":"Gupta A, Kharbanda OP, Sardana V, Balachandran R, Sardana HK (2016) Accuracy of 3D cephalometric measurements based on an automatic knowledge-based landmark detection algorithm. Int J Comput Assist Radiol Surg 11:1297\u20131309","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"16961_CR23","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1504\/IJCVR.2020.108153","volume":"10","author":"A Gupta","year":"2020","unstructured":"Gupta A (2020) Challenges for Computer Aided Diagnostics using X-Ray and Tomographic Reconstruction Images in craniofacial applications. Int J Comput Vis Robot 10:360\u2013371","journal-title":"Int J Comput Vis Robot"},{"key":"16961_CR24","doi-asserted-by":"publisher","unstructured":"Gupta A (2019) Current research opportunities of image processing and computer vision. Comput Sci 20(4). https:\/\/doi.org\/10.7494\/csci.2019.20.4.3163","DOI":"10.7494\/csci.2019.20.4.3163"},{"key":"16961_CR25","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1016\/S0901-5027(06)80085-8","volume":"24","author":"MM Cohen Jr","year":"1995","unstructured":"Cohen MM Jr (1995) Perspectives on craniofacial asymmetry. III. Common and\/or well-known causes of asymmetry. Int J Oral Maxillofac Surg 24:127\u2013133","journal-title":"Int J Oral Maxillofac Surg"},{"key":"16961_CR26","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1093\/ejo\/cjl065","volume":"29","author":"K Sayinsu","year":"2007","unstructured":"Sayinsu K, Isik F, Trakyali G, Arun T (2007) An evaluation of the errors in cephalometric measurements on scanned cephalometric images and conventional tracings. Eur J Orthod 29:105\u2013108","journal-title":"Eur J Orthod"}],"container-title":["Multimedia Tools and Applications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11042-023-16961-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11042-023-16961-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11042-023-16961-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,4,2]],"date-time":"2024-04-02T13:32:57Z","timestamp":1712064777000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11042-023-16961-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,28]]},"references-count":26,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2024,4]]}},"alternative-id":["16961"],"URL":"https:\/\/doi.org\/10.1007\/s11042-023-16961-y","relation":{},"ISSN":["1573-7721"],"issn-type":[{"type":"electronic","value":"1573-7721"}],"subject":[],"published":{"date-parts":[[2023,9,28]]},"assertion":[{"value":"25 January 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 August 2023","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 September 2023","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 September 2023","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.\" The ethical approval was received from Institutional Ethics Committee of AIIMS (All India Institutes of Medical Sciences), Bathinda to conduct this study under IEC No. IEC-01\/2020\u2013015.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}}]}}