{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,20]],"date-time":"2025-09-20T19:26:39Z","timestamp":1758396399444,"version":"3.37.3"},"reference-count":57,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2018,12,13]],"date-time":"2018-12-13T00:00:00Z","timestamp":1544659200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["61773194","61304084"],"award-info":[{"award-number":["61773194","61304084"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Natural Science Foundation of Fujian Province of China","award":["2018J01542"],"award-info":[{"award-number":["2018J01542"]}]},{"name":"Program for New Century Excellent Talents in Fujian Province University"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Neural Process Lett"],"published-print":{"date-parts":[[2019,8]]},"DOI":"10.1007\/s11063-018-9965-7","type":"journal-article","created":{"date-parts":[[2018,12,13]],"date-time":"2018-12-13T05:15:12Z","timestamp":1544678112000},"page":"887-909","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Classification of Gait Patterns Using Kinematic and Kinetic Features, Gait Dynamics and Neural Networks in Patients with Unilateral Anterior Cruciate Ligament Deficiency"],"prefix":"10.1007","volume":"50","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8353-8265","authenticated-orcid":false,"given":"Wei","family":"Zeng","sequence":"first","affiliation":[]},{"given":"Shiek Abdullah","family":"Ismail","sequence":"additional","affiliation":[]},{"given":"Yoong Ping","family":"Lim","sequence":"additional","affiliation":[]},{"given":"Richard","family":"Smith","sequence":"additional","affiliation":[]},{"given":"Evangelos","family":"Pappas","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2018,12,13]]},"reference":[{"issue":"1","key":"9965_CR1","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1016\/j.humov.2011.04.009","volume":"31","author":"B Gao","year":"2012","unstructured":"Gao B, Cordova ML, Zheng NN (2012) Three-dimensional joint kinematics of ACL-deficient and ACL-reconstructed knees during stair ascent and descent. Hum Mov Sci 31(1):222\u2013235","journal-title":"Hum Mov Sci"},{"issue":"2","key":"9965_CR2","doi-asserted-by":"publisher","first-page":"56","DOI":"10.2519\/jospt.2007.2292","volume":"37","author":"JR Houck","year":"2007","unstructured":"Houck JR, De Haven KE, Maloney M (2007) Influence of anticipation on movement patterns in subjects with ACL deficiency classified as noncopers. J Orthop Sports Phys Ther 37(2):56\u201364","journal-title":"J Orthop Sports Phys Ther"},{"issue":"3","key":"9965_CR3","doi-asserted-by":"publisher","first-page":"598","DOI":"10.1177\/0363546517744313","volume":"46","author":"JA Thompson-Kolesar","year":"2018","unstructured":"Thompson-Kolesar JA, Gatewood CT, Tran AA, Silder A, Shultz R, Delp SL, Dragoo JL (2018) Age influences biomechanical changes after participation in an anterior cruciate ligament injury prevention program. Am J Sports Med 46(3):598\u2013606","journal-title":"Am J Sports Med"},{"issue":"1","key":"9965_CR4","first-page":"1","volume":"1","author":"MH Lam","year":"2009","unstructured":"Lam MH, Fong DTP, Yung PSH, Ho EP, Chan WY, Chan KM (2009) Knee stability assessment on anterior cruciate ligament injury: clinical and biomechanical approaches. Sports Med Arthrosc Rehabilit Ther Technol 1(1):1","journal-title":"Sports Med Arthrosc Rehabilit Ther Technol"},{"issue":"10","key":"9965_CR5","doi-asserted-by":"publisher","first-page":"2526","DOI":"10.1016\/j.jbiomech.2014.03.027","volume":"47","author":"K Takeda","year":"2014","unstructured":"Takeda K, Hasegawa T, Kiriyama Y, Matsumoto H, Otani T, Toyama Y, Nagura T (2014) Kinematic motion of the anterior cruciate ligament deficient knee during functionally high and low demanding tasks. J Biomech 47(10):2526\u20132530","journal-title":"J Biomech"},{"key":"9965_CR6","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1016\/j.clinbiomech.2016.04.002","volume":"35","author":"SA Ismail","year":"2016","unstructured":"Ismail SA, Button K, Simic M, Van Deursen R, Pappas E (2016) Three-dimensional kinematic and kinetic gait deviations in individuals with chronic anterior cruciate ligament deficient knee: a systematic review and meta-analysis. Clin Biomech 35:68\u201380","journal-title":"Clin Biomech"},{"issue":"6","key":"9965_CR7","doi-asserted-by":"publisher","first-page":"871","DOI":"10.2106\/00004623-199072060-00012","volume":"72","author":"M Berchuck","year":"1990","unstructured":"Berchuck M, Andriacchi TP, Bach BR, Reider B (1990) Gait adaptations by patients who have a deficient anterior cruciate ligament. J Bone Jt Surg 72(6):871\u2013877","journal-title":"J Bone Jt Surg"},{"issue":"3","key":"9965_CR8","doi-asserted-by":"publisher","first-page":"586","DOI":"10.1177\/0363546509349492","volume":"38","author":"I Eitzen","year":"2010","unstructured":"Eitzen I, Eitzen TJ, Holm I, Snyder-Mackler L, Risberg MA (2010) Anterior cruciate ligament deficient potential copers and noncopers reveal different isokinetic quadriceps strength profiles in the early stage after injury. Am J Sports Med 38(3):586\u2013593","journal-title":"Am J Sports Med"},{"issue":"5","key":"9965_CR9","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1111\/j.1600-0838.1998.tb00484.x","volume":"8","author":"T Muneta","year":"1998","unstructured":"Muneta T, Seklya I, Ogiuchi T, Yagishita K, Yamamoto H, Shinomiya K (1998) Objective factors affecting overall subjective evaluation of recovery after anterior cruciate ligament reconstruction. Scand J Med Sci Sports 8(5):283\u2013289","journal-title":"Scand J Med Sci Sports"},{"key":"9965_CR10","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1016\/j.cmpb.2016.12.006","volume":"140","author":"I Stajduhar","year":"2017","unstructured":"Stajduhar I, Mamula M, Miletic D, Unal G (2017) Semi-automated detection of anterior cruciate ligament injury from MRI. Comput Methods Progr Biomed 140:151\u2013164","journal-title":"Comput Methods Progr Biomed"},{"issue":"3","key":"9965_CR11","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1016\/j.jbiomech.2012.10.010","volume":"46","author":"ME Zabala","year":"2013","unstructured":"Zabala ME, Favre J, Scanlan SF, Donahue J, Andriacchi TP (2013) Three-dimensional knee moments of ACL reconstructed and control subjects during gait, stair ascent, and stair descent. J Biomech 46(3):515\u2013520","journal-title":"J Biomech"},{"issue":"1","key":"9965_CR12","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1109\/TBME.2013.2278780","volume":"61","author":"HC Chen","year":"2014","unstructured":"Chen HC, Wu CH, Wang CK, Lin CJ, Sun YN (2014) A Joint-constraint model-based system for reconstructing total knee motion. IEEE Trans Biomed Eng 61(1):171\u2013181","journal-title":"IEEE Trans Biomed Eng"},{"key":"9965_CR13","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1016\/j.jbiomech.2004.02.010","volume":"38","author":"TP Andriacchi","year":"2005","unstructured":"Andriacchi TP, Dyrby CO (2005) Interactions between kinematics and loading during walking for the normal and ACL deficient knee. J Biomech 38:293\u2013298","journal-title":"J Biomech"},{"key":"9965_CR14","doi-asserted-by":"publisher","first-page":"1406","DOI":"10.1007\/s00167-007-0373-1","volume":"15","author":"C Moraiti","year":"2007","unstructured":"Moraiti C, Stergiou N, Ristanis S, Georgoulis AD (2007) ACL deficiency affects stride-to-stride variability as measured using nonlinear methodology. Knee Surg Sports Traumatol Arthrosc 15:1406\u20131413","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"1","key":"9965_CR15","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1007\/s00167-009-0886-x","volume":"18","author":"M Lindstrom","year":"2010","unstructured":"Lindstrom M, Fellander-Tsai L, Wredmark T, Henriksson M (2010) Adaptations of gait and muscle activation in chronic ACL deficiency. Knee Surg Sports Traumatol Arthrosc 18(1):106\u2013114","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"9965_CR16","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1097\/01.blo.0000197079.26600.09","volume":"442","author":"TP Andriacchi","year":"2006","unstructured":"Andriacchi TP, Briant PL, Bevill SL, Koo S (2006) Rotational changes at the knee after ACL injury cause cartilage thinning. Clin Orthop Relat Res 442:39\u201344","journal-title":"Clin Orthop Relat Res"},{"key":"9965_CR17","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1016\/j.clinbiomech.2016.02.008","volume":"33","author":"J Christian","year":"2016","unstructured":"Christian J, Kroll J, Strutzenberger G, Alexander N, Ofner M, Schwameder H (2016) Computer aided analysis of gait patterns in patients with acute anterior cruciate ligament injury. Clin Biomech 33:55\u201360","journal-title":"Clin Biomech"},{"issue":"5","key":"9965_CR18","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1080\/10255842.2010.542153","volume":"15","author":"BM Eskofier","year":"2012","unstructured":"Eskofier BM, Kraus M, Worobets JT, Stefanyshyn DJ, Nigg BM (2012) Pattern classification of kinematic and kinetic running data to distinguish gender, shod\/barefoot and injury groups with feature ranking. Comput Methods Biomech Biomed Eng 15(5):467\u2013474","journal-title":"Comput Methods Biomech Biomed Eng"},{"issue":"4","key":"9965_CR19","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1007\/s11517-016-1546-1","volume":"55","author":"R Altilio","year":"2017","unstructured":"Altilio R, Paoloni M (2017) Selection of clinical features for pattern recognition applied to gait analysis. Med Biol Eng Comput 55(4):685\u2013695","journal-title":"Med Biol Eng Comput"},{"issue":"2","key":"9965_CR20","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1016\/S0966-6362(00)00095-3","volume":"13","author":"T Chau","year":"2001","unstructured":"Chau T (2001) A review of analytical techniques for gait data. Part 2: neural network and wavelet methods. Gait Posture 13(2):102\u2013120","journal-title":"Gait Posture"},{"issue":"7","key":"9965_CR21","doi-asserted-by":"publisher","first-page":"655","DOI":"10.1007\/s11517-015-1269-8","volume":"53","author":"A Habachi El","year":"2015","unstructured":"El Habachi A, Moissenet F, Duprey S, Cheze L, Dumas R (2015) Global sensitivity analysis of the joint kinematics during gait to the parameters of a lower limb multi-body model. Med Biol Eng Comput 53(7):655\u2013667","journal-title":"Med Biol Eng Comput"},{"issue":"7","key":"9965_CR22","doi-asserted-by":"publisher","first-page":"1127","DOI":"10.1016\/j.jbiomech.2012.02.008","volume":"45","author":"P Federolf","year":"2012","unstructured":"Federolf P, Tecante K, Nigg B (2012) A holistic approach to study the temporal variability in gait. J Biomech 45(7):1127\u20131132","journal-title":"J Biomech"},{"key":"9965_CR23","doi-asserted-by":"publisher","first-page":"75","DOI":"10.3389\/fbioe.2018.00075","volume":"6","author":"F Cabitza","year":"2018","unstructured":"Cabitza F, Locoro A, Banfi G (2018) Machine learning in orthopedics: a literature review. Front Bioeng Biotechnol 6:75","journal-title":"Front Bioeng Biotechnol"},{"issue":"2","key":"9965_CR24","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1007\/s00264-015-2839-y","volume":"40","author":"A Matic","year":"2016","unstructured":"Matic A, Savic SP, Ristic B, Stevanovic VB, Devedzic G (2016) Infrared assessment of knee instability in ACL deficient patients. Int Orthop 40(2):385\u2013391","journal-title":"Int Orthop"},{"key":"9965_CR25","doi-asserted-by":"crossref","unstructured":"Pandey G, Dukkipati A (2017) Unsupervised feature learning with discriminative encoder. In: 2017 IEEE international conference on data mining, pp 367\u2013376.3","DOI":"10.1109\/ICDM.2017.46"},{"issue":"5","key":"9965_CR26","doi-asserted-by":"publisher","first-page":"2420","DOI":"10.1109\/TIP.2018.2804218","volume":"27","author":"J Zhang","year":"2018","unstructured":"Zhang J, Yu J, Tao D (2018) Local deep-feature alignment for unsupervised dimension reduction. IEEE Trans Image Process 27(5):2420\u20132432","journal-title":"IEEE Trans Image Process"},{"issue":"5","key":"9965_CR27","doi-asserted-by":"publisher","first-page":"1246","DOI":"10.1109\/TMM.2017.2762010","volume":"20","author":"G Ning","year":"2018","unstructured":"Ning G, Zhang Z, He Z (2018) Knowledge-guided deep fractal neural networks for human pose estimation. IEEE Trans Multimed 20(5):1246\u20131259","journal-title":"IEEE Trans Multimed"},{"key":"9965_CR28","doi-asserted-by":"crossref","unstructured":"Rhodin H, Salzmann M, Fua P (2018) Unsupervised geometry-aware representation for 3D human pose estimation. In: European conference on computer vision","DOI":"10.1007\/978-3-030-01249-6_46"},{"issue":"5","key":"9965_CR29","doi-asserted-by":"publisher","first-page":"2019","DOI":"10.1109\/TIP.2014.2311377","volume":"23","author":"J Yu","year":"2014","unstructured":"Yu J, Rui Y, Tao D (2014) Click prediction for web image reranking using multimodal sparse coding. IEEE Trans Image Process 23(5):2019\u20132032","journal-title":"IEEE Trans Image Process"},{"issue":"4","key":"9965_CR30","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1109\/TCYB.2014.2336697","volume":"45","author":"J Yu","year":"2015","unstructured":"Yu J, Tao D, Wang M, Rui Y (2015) Learning to rank using user clicks and visual features for image retrieval. IEEE Trans Cybern 45(4):767\u2013779","journal-title":"IEEE Trans Cybern"},{"issue":"12","key":"9965_CR31","doi-asserted-by":"publisher","first-page":"5659","DOI":"10.1109\/TIP.2015.2487860","volume":"24","author":"C Hong","year":"2015","unstructured":"Hong C, Yu J, Wan J, Tao D, Wang M (2015) Multimodal deep autoencoder for human pose recovery. IEEE Trans Image Process 24(12):5659\u20135670","journal-title":"IEEE Trans Image Process"},{"issue":"6","key":"9965_CR32","first-page":"3742","volume":"62","author":"C Hong","year":"2015","unstructured":"Hong C, Yu J, Tao D, Wang M (2015) Image-based three-dimensional human pose recovery by multiview locality-sensitive sparse retrieval. IEEE Trans Ind Electron 62(6):3742\u20133751","journal-title":"IEEE Trans Ind Electron"},{"issue":"12","key":"9965_CR33","doi-asserted-by":"publisher","first-page":"4014","DOI":"10.1109\/TCYB.2016.2591583","volume":"47","author":"J Yu","year":"2017","unstructured":"Yu J, Yang X, Gao F, Tao D (2017) Deep multimodal distance metric learning using click constraints for image ranking. IEEE Trans Cybern 47(12):4014\u20134024","journal-title":"IEEE Trans Cybern"},{"key":"9965_CR34","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1016\/j.gaitpost.2017.12.016","volume":"60","author":"S Mehdizadeh","year":"2017","unstructured":"Mehdizadeh S (2017) The largest Lyapunov exponent of gait in young and elderly individuals: a systematic review. Gait Posture 60:241\u2013250","journal-title":"Gait Posture"},{"issue":"03","key":"9965_CR35","doi-asserted-by":"publisher","first-page":"1750016","DOI":"10.4015\/S1016237217500168","volume":"29","author":"AR Jac Fredo","year":"2017","unstructured":"Jac Fredo AR, Josena TR, Palaniappan R, Mythili A (2017) Classification of normal and knee joint disorder vibroarthrographic signals using multifractals and support vector machine. Biomed Eng Appl Basis Commun 29(03):1750016","journal-title":"Biomed Eng Appl Basis Commun"},{"issue":"11","key":"9965_CR36","doi-asserted-by":"publisher","first-page":"3153","DOI":"10.1007\/s00521-016-2230-y","volume":"28","author":"Y Zhang","year":"2017","unstructured":"Zhang Y, Ji X, Liu B, Huang D, Xie F, Zhang Y (2017) Combined feature extraction method for classification of EEG signals. Neural Comput Appl 28(11):3153\u20133161","journal-title":"Neural Comput Appl"},{"issue":"2","key":"9965_CR37","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1007\/s10439-012-0668-3","volume":"41","author":"JM Yentes","year":"2013","unstructured":"Yentes JM, Hunt N, Schmid KK, Kaipust JP, McGrath D, Stergiou N (2013) The appropriate use of approximate entropy and sample entropy with short data sets. Ann Biomed Eng 41(2):349\u2013365","journal-title":"Ann Biomed Eng"},{"issue":"2","key":"9965_CR38","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1123\/mcj.16.2.229","volume":"16","author":"JP Kaipust","year":"2012","unstructured":"Kaipust JP, Huisinga JM, Filipi M, Stergiou N (2012) Gait variability measures reveal differences between multiple sclerosis patients and healthy controls. Mot Control 16(2):229\u2013244","journal-title":"Mot Control"},{"issue":"1","key":"9965_CR39","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1109\/TNN.2005.860843","volume":"17","author":"C Wang","year":"2006","unstructured":"Wang C, Hill DJ (2006) Learning from neural control. IEEE Trans Neural Netw 17(1):130\u2013146","journal-title":"IEEE Trans Neural Netw"},{"issue":"3","key":"9965_CR40","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1109\/TNN.2006.889496","volume":"18","author":"C Wang","year":"2007","unstructured":"Wang C, Hill DJ (2007) Deterministic learning and rapid dynamical pattern recognition. IEEE Trans Neural Netw 18(3):617\u2013630","journal-title":"IEEE Trans Neural Netw"},{"key":"9965_CR41","volume-title":"Deterministic learning theory for identification, recognition and control","author":"C Wang","year":"2009","unstructured":"Wang C, Hill DJ (2009) Deterministic learning theory for identification, recognition and control. CRC Press, Boca Raton"},{"issue":"4","key":"9965_CR42","doi-asserted-by":"publisher","first-page":"1307","DOI":"10.1142\/S0218127409023640","volume":"19","author":"C Wang","year":"2009","unstructured":"Wang C, Chen T, Chen G, Hill DJ (2009) Deterministic learning of nonlinear dynamical systems. Int J Bifurc Chaos 19(4):1307\u20131328","journal-title":"Int J Bifurc Chaos"},{"issue":"5","key":"9965_CR43","doi-asserted-by":"publisher","first-page":"1008","DOI":"10.1109\/72.712182","volume":"9","author":"J Farrell","year":"1998","unstructured":"Farrell J (1998) Stability and approximator convergence in nonparametric nonlinear adaptive control. IEEE Trans Neural Netw 9(5):1008\u20131020","journal-title":"IEEE Trans Neural Netw"},{"key":"9965_CR44","doi-asserted-by":"publisher","first-page":"1163","DOI":"10.1007\/s00521-012-1324-4","volume":"24","author":"AT Azar","year":"2014","unstructured":"Azar AT, El-Said SA (2014) Performance analysis of support vector machines classifiers in breast cancer mammography recognition. Neural Comput Appl 24:1163\u20131177","journal-title":"Neural Comput Appl"},{"issue":"3","key":"9965_CR45","first-page":"175","volume":"11","author":"K Chu","year":"1999","unstructured":"Chu K (1999) An introduction to sensitivity, specificity, predictive values and likelihood ratios. Emerg Med Australas 11(3):175\u2013181","journal-title":"Emerg Med Australas"},{"key":"9965_CR46","doi-asserted-by":"publisher","first-page":"1250","DOI":"10.1007\/978-3-540-74282-1_141","volume-title":"Advanced intelligent computing theories and applications. With aspects of contemporary intelligent computing techniques","author":"Q Yuan","year":"2007","unstructured":"Yuan Q, Cai C, Xiao H, Liu X, Wen Y (2007) Diagnosis of breast tumours and evaluation of prognostic risk by using machine learning approaches. In: Huang DS, Heutte L, Loog M (eds) Advanced intelligent computing theories and applications. With aspects of contemporary intelligent computing techniques. Springer, Berlin, pp 1250\u20131260"},{"key":"9965_CR47","doi-asserted-by":"publisher","first-page":"e26","DOI":"10.1016\/j.jsams.2015.12.439","volume":"19","author":"Y Kaplan","year":"2015","unstructured":"Kaplan Y (2015) Identifying individuals with an anterior cruciate ligament deficient knee as copers and non-copers: a narrative literature review. J Sci Med Sport 19:e26","journal-title":"J Sci Med Sport"},{"issue":"5","key":"9965_CR48","doi-asserted-by":"publisher","first-page":"1403","DOI":"10.1007\/s00167-015-3709-2","volume":"25","author":"E Iliopoulos","year":"2017","unstructured":"Iliopoulos E, Galanis N, Iosifidis M, Zafeiridis A, Papadopoulos P, Potoupnis M, Kirkos J (2017) Anterior cruciate ligament deficiency reduces walking economy in copers and non-copers. Knee Surg Sports Traumatol Arthrosc 25(5):1403\u20131411","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"7","key":"9965_CR49","doi-asserted-by":"publisher","first-page":"1269","DOI":"10.1249\/MSS.0000000000000236","volume":"46","author":"MA Robinson","year":"2014","unstructured":"Robinson MA, Donnelly CJ, Tsao J (2014) Impact of knee modeling approach on indicators and classification of anterior cruciate ligament injury risk. Med Sci Sports Exercise 46(7):1269\u20131276","journal-title":"Med Sci Sports Exercise"},{"issue":"3","key":"9965_CR50","doi-asserted-by":"publisher","first-page":"566","DOI":"10.1007\/s10439-013-0914-3","volume":"42","author":"M Atarod","year":"2014","unstructured":"Atarod M, Frank CB, Shrive NG (2014) Kinematic and kinetic interactions during normal and ACL-deficient gait: a longitudinal in vivo study. Ann Biomed Eng 42(3):566\u2013578","journal-title":"Ann Biomed Eng"},{"issue":"1","key":"9965_CR51","doi-asserted-by":"publisher","first-page":"7269","DOI":"10.1038\/s41598-017-06601-5","volume":"7","author":"H Huang","year":"2017","unstructured":"Huang H, Guo J, Yang J, Jiang Y, Yu Y, M\u00fcller S, Ao Y (2017) Isokinetic angle-specific moments and ratios characterizing hamstring and quadriceps strength in anterior cruciate ligament deficient knees. Sci Rep 7(1):7269","journal-title":"Sci Rep"},{"issue":"1","key":"9965_CR52","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1016\/j.jelekin.2013.10.012","volume":"24","author":"S Almosnino","year":"2014","unstructured":"Almosnino S, Brandon SC, Day AG, Stevenson JM, Dvir Z, Bardana DD (2014) Principal component modeling of isokinetic moment curves for discriminating between the injured and healthy knees of unilateral ACL deficient patients. J Electromyogr Kinesiol 24(1):134\u2013143","journal-title":"J Electromyogr Kinesiol"},{"issue":"4","key":"9965_CR53","doi-asserted-by":"publisher","first-page":"981","DOI":"10.1007\/s00167-013-2436-9","volume":"21","author":"M Berruto","year":"2013","unstructured":"Berruto M, Uboldi F, Gala L, Marelli B, Albisetti W (2013) Is triaxial accelerometer reliable in the evaluation and grading of knee pivot shift phenomenon? Knee Surg Sports Traumatol Arthrosc 21(4):981\u2013985","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"4","key":"9965_CR54","doi-asserted-by":"publisher","first-page":"718","DOI":"10.1007\/s00167-012-1903-z","volume":"20","author":"S Kopf","year":"2012","unstructured":"Kopf S, Kauert R, Halfpaap J, Jung T, Becker R (2012) A new quantitative method for pivot shift grading. Knee Surg Sports Traumatol Arthrosc 20(4):718\u2013723","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"9965_CR55","unstructured":"Xu G, Wang Z, Huang H, Li W, Liu C, Liu S (2018) A model for medical diagnosis based on plantar pressure. arXiv preprint \n                    arXiv:1802.10316"},{"issue":"8","key":"9965_CR56","doi-asserted-by":"publisher","first-page":"1509","DOI":"10.1093\/bioinformatics\/bti171","volume":"21","author":"J Hua","year":"2004","unstructured":"Hua J, Xiong Z, Lowey J, Suh E, Dougherty ER (2004) Optimal number of features as a function of sample size for various classification rules. Bioinformatics 21(8):1509\u20131515","journal-title":"Bioinformatics"},{"issue":"12","key":"9965_CR57","doi-asserted-by":"publisher","first-page":"2479","DOI":"10.1109\/TBME.2006.883697","volume":"53","author":"J Kamruzzaman","year":"2006","unstructured":"Kamruzzaman J, Begg RK (2006) Support vector machines and other pattern recognition approaches to the diagnosis of cerebral palsy gait. IEEE Trans Biomed Eng 53(12):2479\u20132490","journal-title":"IEEE Trans Biomed Eng"}],"container-title":["Neural Processing Letters"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11063-018-9965-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11063-018-9965-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11063-018-9965-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,12,12]],"date-time":"2019-12-12T19:24:41Z","timestamp":1576178681000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11063-018-9965-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,12,13]]},"references-count":57,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,8]]}},"alternative-id":["9965"],"URL":"https:\/\/doi.org\/10.1007\/s11063-018-9965-7","relation":{},"ISSN":["1370-4621","1573-773X"],"issn-type":[{"type":"print","value":"1370-4621"},{"type":"electronic","value":"1573-773X"}],"subject":[],"published":{"date-parts":[[2018,12,13]]},"assertion":[{"value":"13 December 2018","order":1,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with Ethical Standards"}},{"value":"There is no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}