{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,4]],"date-time":"2025-11-04T23:05:18Z","timestamp":1762297518581},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2009,11,18]],"date-time":"2009-11-18T00:00:00Z","timestamp":1258502400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Sign Process Syst"],"published-print":{"date-parts":[[2011,8]]},"DOI":"10.1007\/s11265-009-0430-8","type":"journal-article","created":{"date-parts":[[2009,11,17]],"date-time":"2009-11-17T13:23:42Z","timestamp":1258464222000},"page":"187-194","source":"Crossref","is-referenced-by-count":35,"title":["QRS Detection Based on Morphological Filter and Energy Envelope for Applications in Body Sensor Networks"],"prefix":"10.1007","volume":"64","author":[{"given":"Fei","family":"Zhang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yong","family":"Lian","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2009,11,18]]},"reference":[{"key":"430_CR1","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1109\/10.43620","volume":"37","author":"GM Friesen","year":"1990","unstructured":"Friesen, G. M., Jannett, T. C., Jadallah, M. A., Yates, S. L., Quint, S. R., & Nagle, H. T. (1990). A comparison of the noise sensitivity of nine QRS detection algorithms. IEEE Transactions on Bio-Medical Engineering, 37, 85\u201398.","journal-title":"IEEE Transactions on Bio-Medical Engineering"},{"key":"430_CR2","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1109\/51.993193","volume":"21","author":"BU Kohler","year":"2002","unstructured":"Kohler, B. U., Hennig, C., & Orglmeister, R. (2002). The principles of software QRS detection. IEEE Eng. in Medicine and Biology Magazine, 21, 42\u201357.","journal-title":"IEEE Eng. in Medicine and Biology Magazine"},{"key":"430_CR3","doi-asserted-by":"crossref","unstructured":"Peelers, R. L. M., Karel, J. M. H., Westra, R. L., Haddad, S. A. P., Serdijn, W. A. (2006) Multiwavelet design for cardiac signal processing. in Proc. of 28th Int. Conf. of the IEEE EMBS.","DOI":"10.1109\/IEMBS.2006.4397744"},{"issue":"12","key":"430_CR4","doi-asserted-by":"crossref","first-page":"2686","DOI":"10.1109\/TCSI.2005.857925","volume":"52","author":"J Rodrigues","year":"2005","unstructured":"Rodrigues, J., Olsson, L., S\u00f6rnmo, T., & \u00d6wall, V. (2005). Digital implementation of a wavelet-based event detector for cardiac pacemakers. IEEE TCAS-I, 52(12), 2686\u20132698.","journal-title":"IEEE TCAS-I"},{"key":"430_CR5","doi-asserted-by":"crossref","unstructured":"Zhang, F., Wei, Y., & Lian, Y. (2008). Efficient QRS detection in wearable ECG Devices for body sensor network. The 5th IEEE International Workshop on Wearable and Implantable Body Sensor Networks, Hong Kong, China, Jun 1\u20133.","DOI":"10.1109\/ISSMDBS.2008.4575076"},{"key":"430_CR6","unstructured":"Zhang, F., Wei, Y., & Lian, Y. (2009). Frequency response masking based filter bank for qrs detection in wearable biomedical devices. IEEE International Symposium on Circuits and Systems, Taipei, Taiwan, May 24\u201327."},{"key":"430_CR7","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1049\/ip-vis:19981557","volume":"145","author":"A Gasterators","year":"1998","unstructured":"Gasterators, A., Andreadis, I., & Tsalides, P. H. (1998). Fuzzy soft mathematical morphology. IEEE Proceedings Vision, Image and Signal Processing, 145, 41\u201349.","journal-title":"IEEE Proceedings Vision, Image and Signal Processing"},{"key":"430_CR8","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1016\/j.infrared.2004.06.001","volume":"46","author":"F Zhang","year":"2005","unstructured":"Zhang, F., Li, C., & Shi, L. (2005). Detecting and tracking dim moving point target in IR image sequences. Infrared Physics and Technology, 46, 323\u2013328.","journal-title":"Infrared Physics and Technology"},{"key":"430_CR9","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1109\/10.16474","volume":"36","author":"C-HN Chu","year":"1989","unstructured":"Chu, C.-H. N. & Delp, E. J. (1989). Impulsive noise suppression and background normalization of electrocardiogram signals using morphological operators. IEEE Transactions on Biomedical Engineering, 36, 262\u2013273.","journal-title":"IEEE Transactions on Biomedical Engineering"},{"key":"430_CR10","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1109\/10.212060","volume":"40","author":"PE Trahanias","year":"1993","unstructured":"Trahanias, P. E. (1993). An approach to QRS complex detection using mathematical morphology. IEEE Transactions on Biomedical Engineering, 40, 201\u2013205.","journal-title":"IEEE Transactions on Biomedical Engineering"},{"key":"430_CR11","unstructured":"Chen, Y. L., & Duan, H. L. (2005). A QRS complex detection algorithm based on mathematical morphology and envelope. in Proc. of 27th Annual International Conf. of the IEEE EMBS, Shanghai, China, pp. 4654\u20134657."},{"key":"430_CR12","doi-asserted-by":"crossref","unstructured":"Zhang, F., Tan, J., & Lian, Y (2007). An effective QRS detection algorithm for wearable ECG in Body Area Network. in Proc. of IEEE International Conf. on Biomedical Circuits and Systems.","DOI":"10.1109\/BIOCAS.2007.4463342"},{"issue":"4","key":"430_CR13","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1109\/TBCAS.2009.2020093","volume":"3","author":"F Zhang","year":"2009","unstructured":"Zhang, F. & Lian, Y. (2009). QRS detection based on multi-scale mathematical morphology for wearable ECG devices in body area networks. IEEE Transaction on Biomedical Circuits and Systems, 3(4), 220\u2013228.","journal-title":"IEEE Transaction on Biomedical Circuits and Systems"},{"key":"430_CR14","doi-asserted-by":"crossref","unstructured":"Maragos, P., Schafter, R. W., & Butt, M. A. (1996). Mathematical morphology and its applications to image and signal processing, 1996 by Kluwer Academic.","DOI":"10.1007\/978-1-4613-0469-2"},{"key":"430_CR15","unstructured":"Oppenheim, A. V., Schafer, R. W. (1989). Discrete-time signal processing, Prentice-Hall, Englewood Cliffs, NJ, pp. 775."},{"key":"430_CR16","unstructured":"Whalen, A. D. (1975). Detection of signals in noise, Prentice-Hall Inc."},{"key":"430_CR17","unstructured":"Zhou, S. K., Wang, J. T., & Xu, J. R. (1988). The real-time detection of QRS complex using the envelop of ECG. in Proc. of 10th Annual IEEE EMBS International Conference."},{"key":"430_CR18","doi-asserted-by":"crossref","first-page":"538","DOI":"10.1007\/BF02442378","volume":"21","author":"ME Nygards","year":"1983","unstructured":"Nygards, M. E. & Sornmo, L. (1983). Delineation of the QRS complex using the envelope of the ECG. Medical and Biological Engineering and Computing, 21, 538\u2013547.","journal-title":"Medical and Biological Engineering and Computing"},{"key":"430_CR19","doi-asserted-by":"crossref","unstructured":"Zhang, F., & Lian, Y. (2007). Novel QRS Detection by CWT for ECG Sensor. IEEE International Conference of Biomedical Circuits and Systems, Montreal, Canada, Nov 27\u201330.","DOI":"10.1109\/BIOCAS.2007.4463346"},{"key":"430_CR20","unstructured":"Available: http:\/\/www.physionet.org\/physiobank\/database\/mitdb\/"},{"key":"430_CR21","doi-asserted-by":"crossref","first-page":"1137","DOI":"10.1109\/10.469381","volume":"42","author":"R Poli","year":"1995","unstructured":"Poli, R., Cagnoni, S., & Valli, G. (1995). Genetic design of optimum linear and non-linear QRS Detectors. IEEE Transactions on Biomedical Engineering, 42, 1137\u20131141.","journal-title":"IEEE Transactions on Biomedical Engineering"},{"key":"430_CR22","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1109\/TBME.1985.325532","volume":"32","author":"J Pan","year":"1985","unstructured":"Pan, J. & Tompkins, W. J. (1985). A real time QRS detection algorithm. IEEE Transactions on Biomedical Engineering, 32, 230\u2013236.","journal-title":"IEEE Transactions on Biomedical Engineering"},{"key":"430_CR23","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.cmpb.2005.11.012","volume":"82","author":"S Chen","year":"2006","unstructured":"Chen, S., Chen, H., & Chan, H. (2006). A real-time QRS detection method based on moving-averaging incorporating with wavelet denosing. Comput. methods and programs in biomedicine, 82, 187\u2013195.","journal-title":"Comput. methods and programs in biomedicine"},{"key":"430_CR24","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1109\/10.740882","volume":"46","author":"VX Afonso","year":"1999","unstructured":"Afonso, V. X., Tompkins, W. J., Nguyen, T. Q., & Luo, S. (1999). ECG beat detection using filter banks. IEEE Transactions on Biomedical Engineering, 46, 192\u2013201.","journal-title":"IEEE Transactions on Biomedical Engineering"},{"key":"430_CR25","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.1109\/TBME.1986.325695","volume":"33","author":"PS Hamilton","year":"1986","unstructured":"Hamilton, P. S. & Tompkins, W. J. (1986). Quantitative investigation of QRS detection rules using the MIT\/BIH arrhythmia database. IEEE Transactions on Biomedical Engineering, 33, 1157\u20131165.","journal-title":"IEEE Transactions on Biomedical Engineering"},{"key":"430_CR26","first-page":"315","volume":"39","author":"Q Xue","year":"1992","unstructured":"Xue, Q., Hu, Y. H., & Tompkins, W. J. (1992). Neural-network-based adaptive filtering for QRS detection. IEEE Transactions on Biomedical Engineering, 39, 315\u2013329.","journal-title":"IEEE Transactions on Biomedical Engineering"},{"key":"430_CR27","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1109\/10.554762","volume":"44","author":"A Ruha","year":"1997","unstructured":"Ruha, A. & Sallinen, S. (1997). A real-time microprocessor QRS detector system with a 1-ms timing accuracy for the measurement of ambulatory HRV. IEEE Transactions on Biomedical Engineering, 44, 159\u2013167.","journal-title":"IEEE Transactions on Biomedical Engineering"},{"key":"430_CR28","unstructured":"Lee, J., Jeong, K., Yoon, J., & Lee, M. (1996). A simple real-time microprocessor QRS detection algorithm. in Proc. of the 18th Annual Int. Conf. of the IEE Eng. and Med. And Biomed Society, pp. 1396\u20131398."}],"container-title":["Journal of Signal Processing Systems"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11265-009-0430-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11265-009-0430-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11265-009-0430-8","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,1]],"date-time":"2019-06-01T12:19:32Z","timestamp":1559391572000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11265-009-0430-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,11,18]]},"references-count":28,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2011,8]]}},"alternative-id":["430"],"URL":"https:\/\/doi.org\/10.1007\/s11265-009-0430-8","relation":{},"ISSN":["1939-8018","1939-8115"],"issn-type":[{"value":"1939-8018","type":"print"},{"value":"1939-8115","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,11,18]]}}}