{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,26]],"date-time":"2025-09-26T00:11:07Z","timestamp":1758845467767},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2010,7,31]],"date-time":"2010-07-31T00:00:00Z","timestamp":1280534400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Sign Process Syst"],"published-print":{"date-parts":[[2012,5]]},"DOI":"10.1007\/s11265-010-0507-4","type":"journal-article","created":{"date-parts":[[2010,7,31]],"date-time":"2010-07-31T19:53:44Z","timestamp":1280606024000},"page":"93-103","source":"Crossref","is-referenced-by-count":11,"title":["Body Sensor Network Based Context-Aware QRS Detection"],"prefix":"10.1007","volume":"67","author":[{"given":"Hongxing","family":"Wei","sequence":"first","affiliation":[]},{"given":"Huaming","family":"Li","sequence":"additional","affiliation":[]},{"given":"Jindong","family":"Tan","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2010,7,31]]},"reference":[{"key":"507_CR1","unstructured":"Data from Centers for Disease Control and Prevention (CDC) (1999)."},{"key":"507_CR2","unstructured":"IMIA Yearbook of Medical Informatics 2005: Ubiquitous Health Care Systems (pp. 125\u2013138) (2004)."},{"key":"507_CR3","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1109\/TITB.2004.837888","volume":"8","author":"U Anliker","year":"2004","unstructured":"Anliker, U., Ward, J. A., Lukowicz, P., Troster, G., Dolveck, F., Baer, M., et al. (2004). Amon: A wearable multiparameter medical monitoring and alert system. IEEE Transactions on Information Technology in Biomedicine, 8, 415\u2013427.","journal-title":"IEEE Transactions on Information Technology in Biomedicine"},{"key":"507_CR4","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1186\/1743-0003-2-6","volume":"2","author":"E Jovanov","year":"2005","unstructured":"Jovanov, E., Milenkovic, A., Otto, C., & de Groen, P. C. (2005). A wireless body area network of intelligent motion sensors for computer assisted physical rehabilitation. Journal of NeuroEngineering and Rehabilitation, 2, 6.","journal-title":"Journal of NeuroEngineering and Rehabilitation"},{"key":"507_CR5","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1109\/MM.2002.1134340","volume":"22","author":"J Hill","year":"2002","unstructured":"Hill, J., & Culler, D. (2002). Mica: A wireless platform for deeply embedded networks. IEEE Micro, 22, 12\u201324.","journal-title":"IEEE Micro"},{"key":"507_CR6","unstructured":"Gao, T., Greenspan, D., Welsh, M., Juang, R. R., & Alm, A. (2005). Vital signs monitoring and patient tracking over a wireless network. In Proceedings of the 27th IEEE EMBS annual international conference."},{"key":"507_CR7","doi-asserted-by":"crossref","unstructured":"Wei, Y., Heidemannvand, J., & Estrin, D. (2002). An energy-efficient mac protocol for wireless sensor networks. In Proceedings of the IEEE Infocom (pp.\u00a01567\u20131576).","DOI":"10.1109\/INFCOM.2002.1019408"},{"key":"507_CR8","unstructured":"van Dam, T., & Langendoen, K. (2003). An adaptive energy-efficient mac protocol for wireless sensor networks. In Proceedings of the 1st ACM conf. on embedded networked sensor systems (Sen-Sys) (pp.\u00a0171\u2013180)."},{"key":"507_CR9","unstructured":"Li, H., & Tan, J. (2005). An ultra-low-power medium access control protocol for body sensor network. In Proceedings of the 27th IEEE EMBS annual international conference (pp.\u00a02451\u20132454)."},{"issue":"1","key":"507_CR10","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1109\/TITB.2005.856864","volume":"10","author":"DM Karantonis","year":"2006","unstructured":"Karantonis, D. M., Narayanan, M. R., Mathie, M., Lovell, N. H., & Celler, B. G. (2006). Implementation of a real-time human movement classifier using a triaxial accelerometer for ambulatory monitoring. IEEE Transactions on Information Technology in Biomedicine, 10(1), 156\u2013167.","journal-title":"IEEE Transactions on Information Technology in Biomedicine"},{"issue":"1","key":"507_CR11","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1109\/TITB.2005.856863","volume":"10","author":"J Parkka","year":"2006","unstructured":"Parkka, J., Ermes, M., Korpipaa, P., Mantyjarvi, J., Peltola, J., & Korhonen, I. (2006). Activity classification using realistic data from wearable sensors. IEEE Transactions on Information Technology in Biomedicine, 10(1), 119\u2013128.","journal-title":"IEEE Transactions on Information Technology in Biomedicine"},{"key":"507_CR12","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.1161\/01.CIR.0000088001.59265.EE","volume":"108","author":"F Peter","year":"2003","unstructured":"Peter, F., Cohn, K., & Fox, M. (2003). Silent myocardial ischemia. Circulation, 108, 1263.","journal-title":"Circulation"},{"issue":"1","key":"507_CR13","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1161\/01.CIR.75.1.101","volume":"75","author":"DS Berman","year":"1987","unstructured":"Berman, D. S., Rozanski, A., & Knoebel, S. B. (1987). The detection of silent ischemia: Cautions and precautions. Circulation, 75(1), 101\u2013105.","journal-title":"Circulation"},{"key":"507_CR14","doi-asserted-by":"crossref","first-page":"1442","DOI":"10.1378\/chest.107.5.1442","volume":"107","author":"R Marcus","year":"1987","unstructured":"Marcus, R., Lowe, R. r., Froelicher, V. F., & Do, D. (1987). The exercise test as gatekeeper. limiting access or appropriately directing resources? Chest, 107, 1442\u20131446.","journal-title":"Chest"},{"key":"507_CR15","first-page":"351","volume":"341","author":"CR Cole","year":"1999","unstructured":"Cole, C. R., Blackstone, E. H., Pashkow, F. J., Snader, C. E., & Lauer, M. S. (1999). Heart-rate recovery immediately after exercise as a predictor of mortality. The New England Journal of Medicine, 341, 351\u2013357.","journal-title":"The New England Journal of Medicine"},{"key":"507_CR16","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1016\/S0735-1097(03)00833-7","volume":"42","author":"DP Vivekananthan","year":"2003","unstructured":"Vivekananthan, D. P., Blackstone, E. H., Pothier, C. E., & Lauer, M. S. (2003). Heart rate recovery after exercise is a predictor of mortality, independent of the angiographic severity of coronary disease. Journal of the American College of Cardiology, 42, 831\u2013838.","journal-title":"Journal of the American College of Cardiology"},{"key":"507_CR17","doi-asserted-by":"crossref","first-page":"1395","DOI":"10.1016\/S0735-1097(01)01171-8","volume":"37","author":"TH Makikallio","year":"2001","unstructured":"Makikallio, T. H., Huikuri, H. V., Makikallio, A., Sourander, L. B., Mitrani, R. D., Castellanos, A., et al. (2001). Prediction of sudden cardiac death by fractal analysis of heart rate variability in elderly subjects. Journal of the American College of Cardiology, 37, 1395\u20131402.","journal-title":"Journal of the American College of Cardiology"},{"key":"507_CR18","unstructured":"IEEE 802.15.4, Wireless Medium Access Control (MAC) and Physical Layer (PHY) Specifications for Low-Rate Wireless Personal Area Networks (LR-WPANs), IEEE, 1 October 2003."},{"key":"507_CR19","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1109\/10.43620","volume":"37","author":"G Friesen","year":"1990","unstructured":"Friesen, G., Jannett, T., Jadallan, M., Yates, S., Quint, S., & Nagle, H. (1990). A comparison of the noise sensitivity of nine qrs detection algorithms. IEEE Transactions on Biomedical Engineering, 37, 85\u201398.","journal-title":"IEEE Transactions on Biomedical Engineering"},{"key":"507_CR20","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1007\/BF02345816","volume":"43","author":"F Portet","year":"2005","unstructured":"Portet, F., Hernandez, A. I., & Carrault, G. (2005). Evaluation of real-time qrs detection algorithms in variable contexts. Medical & Biological Engineering, 43, 379\u2013385.","journal-title":"Medical & Biological Engineering"},{"key":"507_CR21","first-page":"37","volume":"6","author":"WAH Engelse","year":"1979","unstructured":"Engelse, W. A.\u00a0H., & Zeelenberg, C. (1979). A single scan algorithm for qrs-detection and feature extraction. Computers in Cardiology, 6, 37\u201342.","journal-title":"Computers in Cardiology"},{"key":"507_CR22","first-page":"737","volume":"30","author":"W Zong","year":"2003","unstructured":"Zong, W., Moody, G. B., & Jiang, D. (2003). A robust open-source algorithm to detect onset and duration of qrs complexes. Computers in Cardiology, 30, 737\u2013740.","journal-title":"Computers in Cardiology"},{"key":"507_CR23","unstructured":"Mark, R., & Moody, G. (1988). Mit-bih arrhythmia data base directory. Massachusetts Institute of Technology."},{"key":"507_CR24","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1161\/01.CIR.101.23.e215","volume":"101","author":"AL Goldberger","year":"2000","unstructured":"Goldberger, A. L., Amaral, L. A.\u00a0N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., et al. (2000). Physiobank, physiotoolkit, and physionet: Components of a new research resource for complex physiologic signals. Circulation, 101, e215\u2013e220.","journal-title":"Circulation"}],"container-title":["Journal of Signal Processing Systems"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11265-010-0507-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11265-010-0507-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11265-010-0507-4","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,1]],"date-time":"2019-06-01T12:19:34Z","timestamp":1559391574000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11265-010-0507-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,7,31]]},"references-count":24,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2012,5]]}},"alternative-id":["507"],"URL":"https:\/\/doi.org\/10.1007\/s11265-010-0507-4","relation":{},"ISSN":["1939-8018","1939-8115"],"issn-type":[{"value":"1939-8018","type":"print"},{"value":"1939-8115","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,7,31]]}}}