{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,8]],"date-time":"2025-10-08T22:04:30Z","timestamp":1759961070143,"version":"3.37.3"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2021,7,29]],"date-time":"2021-07-29T00:00:00Z","timestamp":1627516800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,7,29]],"date-time":"2021-07-29T00:00:00Z","timestamp":1627516800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Sign Process Syst"],"published-print":{"date-parts":[[2022,6]]},"DOI":"10.1007\/s11265-021-01681-z","type":"journal-article","created":{"date-parts":[[2021,7,29]],"date-time":"2021-07-29T22:02:26Z","timestamp":1627596146000},"page":"579-593","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["A Low-power Dry Electrode-based ECG Signal Acquisition with De-noising and Feature Extraction"],"prefix":"10.1007","volume":"94","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5436-8044","authenticated-orcid":false,"given":"Deepa","family":"Kota","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nishat","family":"Tasneem","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Karthik","family":"Kakaraparty","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ifana","family":"Mahbub","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gayatri","family":"Mehta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kamesh","family":"Namuduri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,7,29]]},"reference":[{"issue":"12","key":"1681_CR1","doi-asserted-by":"publisher","first-page":"e67","DOI":"10.1161\/CIR.0000000000000558","volume":"137","author":"EJ Benjamin","year":"2018","unstructured":"Benjamin, E.J., Virani, S.S., Callaway, C.W., Chamberlain, A.M., Chang, A.R., Cheng, S., Chiuve, S.E., Cushman, M., Delling, F.N., Deo, R., & et al. (2018). Heart disease and stroke statistics\u20142018 update: a report from the american heart association. Circulation, 137(12), e67\u2013e492.","journal-title":"Circulation"},{"key":"1681_CR2","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1016\/j.inffus.2019.06.004","volume":"53","author":"MAG Santos","year":"2020","unstructured":"Santos, M.A.G., Munoz, R., Olivares, R., Rebou\u00e7as Filho, P.P., Del Ser, J., & de Albuquerque, V.H.C. (2020). Online heart monitoring systems on the internet of health things environments: A survey, a reference model and an outlook. Information Fusion, 53, 222\u2013239.","journal-title":"Information Fusion"},{"issue":"18","key":"1681_CR3","doi-asserted-by":"publisher","first-page":"1904664","DOI":"10.1002\/adma.201904664","volume":"32","author":"Y Ling","year":"2020","unstructured":"Ling, Y., An, T., Yap, L.W., Zhu, B., Gong, S., & Cheng, W. (2020). Disruptive, soft, wearable sensors. Advanced Materials, 32(18), 1904664.","journal-title":"Advanced Materials"},{"issue":"15","key":"1681_CR4","doi-asserted-by":"publisher","first-page":"11627","DOI":"10.1039\/C4RA15101A","volume":"5","author":"AC Myers","year":"2015","unstructured":"Myers, A.C., Huang, H., & Zhu, Y. (2015). Wearable silver nanowire dry electrodes for electrophysiological sensing. Rsc Advances, 5(15), 11627\u201311632.","journal-title":"Rsc Advances"},{"key":"1681_CR5","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.sna.2015.09.024","volume":"235","author":"H-L Peng","year":"2015","unstructured":"Peng, H.-L., Liu, J.-Q., Tian, H.-C., Xu, B., Dong, Y.-Z., Yang, B., Chen, X., & Yang, C.-S. (2015). Flexible dry electrode based on carbon nanotube\/polymer hybrid micropillars for biopotential recording. Sensors and Actuators A: Physical, 235, 48\u201356.","journal-title":"Sensors and Actuators A: Physical"},{"issue":"2","key":"1681_CR6","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1109\/TBME.2015.2462312","volume":"63","author":"MA Yokus","year":"2015","unstructured":"Yokus, M.A., & Jur, J.S. (2015). Fabric-based wearable dry electrodes for body surface biopotential recording. IEEE Transactions on Biomedical Engineering, 63(2), 423\u2013430.","journal-title":"IEEE Transactions on Biomedical Engineering"},{"key":"1681_CR7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.snb.2016.02.061","volume":"231","author":"H-L Peng","year":"2016","unstructured":"Peng, H.-L., Liu, J.-Q., Dong, Y.-Z., Yang, B., Chen, X., & Yang, C.-S. (2016). Parylene-based flexible dry electrode for bioptential recording. Sensors and Actuators B: Chemical, 231, 1\u201311.","journal-title":"Sensors and Actuators B: Chemical"},{"key":"1681_CR8","doi-asserted-by":"publisher","first-page":"6074","DOI":"10.1038\/srep06074","volume":"4","author":"SM Lee","year":"2014","unstructured":"Lee, S.M., Byeon, H.J., Lee, J.H., Baek, D.H., Lee, K.H., Hong, J.S., & Lee, S.-H. (2014). Self-adhesive epidermal carbon nanotube electronics for tether-free long-term continuous recording of biosignals. Scientific reports, 4, 6074.","journal-title":"Scientific reports"},{"key":"1681_CR9","doi-asserted-by":"crossref","unstructured":"Tasneem, N.T., Pullano, S.A., Critello, C.D., Fiorillo, A.S., & Mahbub, I. (2020). A low-power on-chip ecg monitoring system based on mwcnt\/pdms dry electrodes. IEEE Sensors Journal.","DOI":"10.1109\/JSEN.2020.3001209"},{"key":"1681_CR10","doi-asserted-by":"crossref","unstructured":"Adhikari, P.R., Tasneem, N., Mahbub, I., & Reid, R.C. (2020). Design of a reverse-electrowetting transducer based wireless self-powered motion sensor. In International Symposium on Circuits and Systems. IEEE.","DOI":"10.1109\/ISCAS45731.2020.9180973"},{"issue":"5","key":"1681_CR11","doi-asserted-by":"publisher","first-page":"861","DOI":"10.1016\/j.dsp.2007.05.009","volume":"18","author":"D Cvetkovic","year":"2008","unstructured":"Cvetkovic, D., \u00dcbeyli, E.D., & Cosic, I. (2008). Wavelet transform feature extraction from human ppg, ecg, and eeg signal responses to elf pemf exposures: A pilot study. Digital signal processing, 18(5), 861\u2013874.","journal-title":"Digital signal processing"},{"key":"1681_CR12","doi-asserted-by":"crossref","unstructured":"Vullings, H.J.L.M., Verhaegen, M.H.G., & Verbruggen, H.B. (1997). Ecg segmentation using time-warping. In International Symposium on Intelligent Data Analysis, pp 275\u2013285. Springer.","DOI":"10.1007\/BFb0052847"},{"issue":"1","key":"1681_CR13","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1109\/51.566158","volume":"16","author":"JS Sahambi","year":"1997","unstructured":"Sahambi, J.S., Tandon, S.N., & Bhatt, R.K.P. (1997). Using wavelet transforms for ecg characterization. an on-line digital signal processing system. IEEE Engineering in Medicine and Biology Magazine, 16(1), 77\u201383.","journal-title":"IEEE Engineering in Medicine and Biology Magazine"},{"key":"1681_CR14","unstructured":"Mahmoodabadi, S.Z., Ahmadian, A., & Abolhasani, M.D. (2005). Ecg feature extraction using daubechies wavelets. In Proceedings of the fifth IASTED International conference on Visualization, Imaging and Image Processing, pp 343\u2013348."},{"key":"1681_CR15","doi-asserted-by":"crossref","unstructured":"Al Abdi, R.M., & Jarrah, M. (2018). Cardiac disease classification using total variation denoising and morlet continuous wavelet transformation of ecg signals. In 2018 IEEE 14th International Colloquium on Signal Processing Its Applications (CSPA), pp 57\u201360.","DOI":"10.1109\/CSPA.2018.8368685"},{"key":"1681_CR16","unstructured":"Moody, G.B., & Mark, R.G. (1990). The mit-bih arrhythmia database on cd-rom and software for use with it. In [1990] Proceedings Computers in Cardiology, pp 185\u2013188."},{"key":"1681_CR17","doi-asserted-by":"crossref","unstructured":"Datta, J., & Mitra, M. (2016). Automated feature extraction of ecg signal by position-index searching method. In 2016 International Conference on Signal Processing, Communication, Power and Embedded System (SCOPES), pp 867\u2013869.","DOI":"10.1109\/SCOPES.2016.7955566"},{"key":"1681_CR18","doi-asserted-by":"publisher","first-page":"152166","DOI":"10.1109\/ACCESS.2019.2948067","volume":"7","author":"C Lastre-Dom\u00ednguez","year":"2019","unstructured":"Lastre-Dom\u00ednguez, C., Shmaliy, Y S, Ibarra-Manzano, O, & Vazquez-Olguin, M (2019). Denoising and features extraction of ecg signals in state space using unbiased fir smoothing. IEEE Access, 7, 152166\u2013152178. https:\/\/doi.org\/10.1109\/ACCESS.2019.2948067 .","journal-title":"IEEE Access"},{"issue":"3","key":"1681_CR19","doi-asserted-by":"publisher","first-page":"722","DOI":"10.1109\/JBHI.2017.2686436","volume":"22","author":"U Satija","year":"2018","unstructured":"Satija, U., Ramkumar, B., & Manikandan, M.S. (2018). Automated ecg noise detection and classification system for unsupervised healthcare monitoring. IEEE Journal of Biomedical and Health Informatics, 22(3), 722\u2013732. https:\/\/doi.org\/10.1109\/JBHI.2017.2686436 .","journal-title":"IEEE Journal of Biomedical and Health Informatics"},{"issue":"1","key":"1681_CR20","first-page":"120","volume":"2","author":"C Chandrakar","year":"2012","unstructured":"Chandrakar, C., & Kowar, M.K. (2012). Denoising ecg signals using adaptive filter algorithm. International Journal of Soft Computing and Engineering (IJSCE), 2(1), 120\u2013123.","journal-title":"International Journal of Soft Computing and Engineering (IJSCE)"},{"key":"1681_CR21","doi-asserted-by":"crossref","unstructured":"Vega-Mart\u00ednez, G, Alvarado-Serrano, C, & Leija-Salas, L (2011). Ecg baseline drift removal using discrete wavelet transform. In 2011 8th International Conference on Electrical Engineering, Computing Science and Automatic Control, pp 1\u20135.","DOI":"10.1109\/ICEEE.2011.6106625"},{"key":"1681_CR22","doi-asserted-by":"crossref","unstructured":"Joshi, S.L., Vatti, R.A., & Tornekar, R.V. (2013). A survey on ecg signal denoising techniques. In 2013 International Conference on Communication Systems and Network Technologies, pp 60\u201364. organization=,.","DOI":"10.1109\/CSNT.2013.22"},{"key":"1681_CR23","doi-asserted-by":"crossref","unstructured":"Rakshit, M, & Das, S (2017). An improved emd based ecg denoising method using adaptive switching mean filter. In 2017 4th International Conference on Signal Processing and Integrated Networks (SPIN), pp 251\u2013255.","DOI":"10.1109\/SPIN.2017.8049954"},{"issue":"5","key":"1681_CR24","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1016\/j.bspc.2011.11.003","volume":"7","author":"MA Kabir","year":"2012","unstructured":"Kabir, M.A., & Shahnaz, C. (2012). Denoising of ecg signals based on noise reduction algorithms in emd and wavelet domains. Biomedical Signal Processing and Control, 7(5), 481\u2013489.","journal-title":"Biomedical Signal Processing and Control"},{"key":"1681_CR25","doi-asserted-by":"crossref","unstructured":"Tasneem, N., & Mahbub, I. (2020). Dry electrode based low-power ecg acquisition system with adaptive motion artifacts cancellation. In 2020 IEEE 63rd International Midwest Symposium on Circuits and Systems (MWSCAS), pp 913\u2013916.","DOI":"10.1109\/MWSCAS48704.2020.9184681"},{"key":"1681_CR26","doi-asserted-by":"crossref","unstructured":"Tasneem, N., Kota, D., Mahbub, I., Mehta, G., Namuduri, K., & Cedars, A. (2020). A dry electrode-based ecg sensor with motion artifacts cancellation and signal analysis for heart irregularity detection. In 2020 IEEE SENSORS, pp 1\u20134.","DOI":"10.1109\/SENSORS47125.2020.9278739"},{"issue":"6","key":"1681_CR27","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1016\/j.irbm.2014.10.004","volume":"35","author":"H-Y Lin","year":"2014","unstructured":"Lin, H.-Y., Liang, S.-Y., Ho, Y.-L., Lin, Y.-H., & Ma, H.-P. (2014). Discrete-wavelet-transform-based noise removal and feature extraction for ecg signals. Irbm, 35(6), 351\u2013361.","journal-title":"Irbm"},{"issue":"12","key":"1681_CR28","doi-asserted-by":"publisher","first-page":"36","DOI":"10.5120\/16850-6712","volume":"96","author":"M Mohamed","year":"2014","unstructured":"Mohamed, M., & Deriche, M. (2014). An approach for ecg feature extraction using daubechies 4 (db4) wavelet. International Journal of Computer Applications, 96(12), 36\u201341.","journal-title":"International Journal of Computer Applications"},{"issue":"22","key":"1681_CR29","doi-asserted-by":"publisher","first-page":"4968","DOI":"10.3390\/app9224968","volume":"9","author":"D Zhang","year":"2019","unstructured":"Zhang, D., Wang, S., Li, F., Wang, J., Sangaiah, A.K., Sheng, V.S., & Ding, X. (2019). An ecg signal de-noising approach based on wavelet energy and sub-band smoothing filter. Applied Sciences, 9 (22), 4968.","journal-title":"Applied Sciences"},{"key":"1681_CR30","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1016\/j.procs.2014.08.048","volume":"37","author":"M AlMahamdy","year":"2014","unstructured":"AlMahamdy, M., & Riley, H.B. (2014). Performance study of different denoising methods for ecg signals. Procedia Computer Science, 37, 325\u2013332.","journal-title":"Procedia Computer Science"},{"key":"1681_CR31","unstructured":"Grasshopper.iics. Ecg feature extraction with wavelet transform and st segment detection using matlab. https:\/\/www.codeproject.com\/."},{"issue":"1","key":"1681_CR32","first-page":"68","volume":"35","author":"C Saritha","year":"2008","unstructured":"Saritha, C., Sukanya, V., & Murthy, Y.N. (2008). Ecg signal analysis using wavelet transforms. Bulg. J. Phys, 35(1), 68\u201377.","journal-title":"Bulg. J. Phys"},{"key":"1681_CR33","doi-asserted-by":"crossref","unstructured":"Eminaga, Y., Coskun, A., & Kale, I. (2018). Area and power efficient implementation of db4 wavelet filter banks for ecg applications using reconfigurable multiplier blocks. In 2018 4th International Conference on Frontiers of Signal Processing (ICFSP), pp 65\u201368.","DOI":"10.1109\/ICFSP.2018.8552046"},{"key":"1681_CR34","doi-asserted-by":"crossref","unstructured":"Nath, R.K., Thapliyal, H., & Caban-Holt, A. (2021). Machine learning based stress monitoring in older adults using wearable sensors and cortisol as stress biomarker. Journal of Signal Processing Systems, pp 1\u201313.","DOI":"10.1007\/s11265-020-01611-5"},{"key":"1681_CR35","doi-asserted-by":"crossref","unstructured":"Lin, H., Sz-Ying Liang, Ho, Y., Lin, Y., & Ma, H. (2013). Discrete-wavelet-transform-based noise reduction and r wave detection for ecg signals. In 2013 IEEE 15th International Conference on e-Health Networking, Applications and Services (Healthcom 2013), pp 355\u2013360.","DOI":"10.1109\/HealthCom.2013.6720700"},{"issue":"23","key":"1681_CR36","doi-asserted-by":"publisher","first-page":"e215","DOI":"10.1161\/01.CIR.101.23.e215","volume":"101","author":"AL Goldberger","year":"2000","unstructured":"Goldberger, A.L., Amaral, L.A.N., Glass, L., Hausdorff, J.M., Ivanov, P.C., Mark, R.G., Mietus, J.E., Moody, G.B., Peng, C.-K., & Stanley, H.E. (2000). PhysioBank, PhysioToolkit, and PhysioNet: Components of a new research resource for complex physiologic signals. Circulation, 101 (23), e215\u2013e220. Circulation Electronic Pages: http:\/\/circ.ahajournals.org\/content\/101\/23\/e215.full PMID:1085218; https:\/\/doi.org\/10.1161\/01.CIR.101.23.e215.","journal-title":"Circulation"},{"issue":"3","key":"1681_CR37","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1007\/s00399-015-0385-3","volume":"26","author":"A Baranchuk","year":"2015","unstructured":"Baranchuk, A., & de Luna, A.B. (2015). The p-wave morphology: what does it tell us?. Herzschrittmachertherapie+ Elektrophysiologie, 26(3), 192\u2013199.","journal-title":"Herzschrittmachertherapie+ Elektrophysiologie"},{"key":"1681_CR38","doi-asserted-by":"crossref","unstructured":"Hashim, F.R., Soraghan, J.J., Petropoulakis, L., & Daud, N.G.N. (2014). Emg cancellation from ecg signals using modified nlms adaptive filters. In 2014 IEEE Conference on Biomedical Engineering and Sciences (IECBES), pp 735\u2013739.","DOI":"10.1109\/IECBES.2014.7047605"},{"key":"1681_CR39","first-page":"1","volume":"3","author":"R Kher","year":"2019","unstructured":"Kher, R. (2019). Signal processing techniques for removing noise from ecg signals. J. Biomed. Eng. Res, 3, 1\u20139.","journal-title":"J. Biomed. Eng. Res"},{"key":"1681_CR40","unstructured":"Sedghamiz, H. (2014). Matlab implementation of pan tompkins ecg qrs detector. Code Available at the File Exchange Site of MathWorks."},{"key":"1681_CR41","doi-asserted-by":"crossref","unstructured":"Kota, D., Tasneem, N.T., & Mahbub, I. (2020). Low power implementation of ecg r-wave peak detector in 180 nm cmos process. In 2020 IEEE 14th Dallas Circuits and Systems Conference (DCAS), pp 1\u20135.","DOI":"10.1109\/DCAS51144.2020.9330635"}],"container-title":["Journal of Signal Processing Systems"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11265-021-01681-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11265-021-01681-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11265-021-01681-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,6,21]],"date-time":"2022-06-21T03:36:19Z","timestamp":1655782579000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11265-021-01681-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,7,29]]},"references-count":41,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2022,6]]}},"alternative-id":["1681"],"URL":"https:\/\/doi.org\/10.1007\/s11265-021-01681-z","relation":{},"ISSN":["1939-8018","1939-8115"],"issn-type":[{"type":"print","value":"1939-8018"},{"type":"electronic","value":"1939-8115"}],"subject":[],"published":{"date-parts":[[2021,7,29]]},"assertion":[{"value":"6 November 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 April 2021","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 July 2021","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 July 2021","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}