{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,4]],"date-time":"2025-06-04T09:31:36Z","timestamp":1749029496728},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2013,5,1]],"date-time":"2013-05-01T00:00:00Z","timestamp":1367366400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Comput. Sci. Technol."],"published-print":{"date-parts":[[2013,5]]},"DOI":"10.1007\/s11390-013-1351-3","type":"journal-article","created":{"date-parts":[[2013,5,2]],"date-time":"2013-05-02T02:35:38Z","timestamp":1367462138000},"page":"499-507","source":"Crossref","is-referenced-by-count":6,"title":["Gallbladder Removal Simulation for Laparoscopic Surgery Training: A Hybrid Modeling Method"],"prefix":"10.1007","volume":"28","author":[{"given":"Youngjun","family":"Kim","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dongjune","family":"Chang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jungsik","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sehyung","family":"Park","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2013,5,1]]},"reference":[{"key":"1351_CR1","unstructured":"Allard J,Cotin S, Faure F et al. Sofa \u2014 An open source framework for medical simulation. In Medicine Meets Virtual Reality 15, Westwood J D, Haluck R S, Hoffman H M et al. (eds), 2007, pp.13\u201318."},{"issue":"3","key":"1351_CR2","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1016\/j.cmpb.2004.11.002","volume":"77","author":"U Meier","year":"2005","unstructured":"Meier U, L\u00f3pez O, Monserrat C, Juan MC, Alca\u00f1iz M (2005) Real-time deformablemodels for surgery simulation: A survey. Computer Methods and Programs in Biomedicine 77(3):183\u2013197","journal-title":"Computer Methods and Programs in Biomedicine"},{"key":"1351_CR3","unstructured":"Mosegaard J. Cardiac surgery simulation \u2014 Graphics hardware meets congenitalheart disease [Ph.D. Thesis]. Department of Computer Science, University of Aarhus, Denmark, 2006."},{"issue":"12","key":"1351_CR4","doi-asserted-by":"crossref","first-page":"1943","DOI":"10.1007\/s00464-003-9052-6","volume":"17","author":"M Schijven","year":"2003","unstructured":"Schijven M, Jakimowicz J (2003) Virtual reality surgical laparoscopic simulators: How to choose. Surgical Endoscopy 17(12):1943\u20131950","journal-title":"Surgical Endoscopy"},{"key":"1351_CR5","first-page":"23","volume":"132","author":"E Basafa","year":"2008","unstructured":"Basafa E, Farahmand F, Vossoughi G (2008) A non-linear mass-spring model for morerealistic and efficient simulation of soft tissues surgery. Studies in Health Technologyand Informatics 132:23\u201325","journal-title":"Studies in Health Technologyand Informatics"},{"issue":"1","key":"1351_CR6","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1109\/2945.764872","volume":"5","author":"S Cotin","year":"1999","unstructured":"Cotin S, Delingette H, Ayache H (1999) Real-time elastic deformations of soft tissues for surgery simulation. IEEE Trans Visualization and Computer Graphics 5(1):62\u201373","journal-title":"IEEE Trans. Visualization and Computer Graphics"},{"issue":"6","key":"1351_CR7","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1109\/38.252559","volume":"13","author":"SA Cover","year":"1993","unstructured":"Cover SA, Ezquerra NF, O\u2019Brien JF et al (1993) Interactively deformable models for surgery simulation. IEEE Computer Graphics and Applications 13(6):68\u201375","journal-title":"IEEE Computer Graphics and Applications"},{"issue":"3","key":"1351_CR8","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1109\/3516.951365","volume":"6","author":"C Basdogan","year":"2001","unstructured":"Basdogan C, Ho CH, Srinivasan MA (2001) Virtual environments for medical training: Graphical and haptic simulation of laparoscopic common bile duct exploration. Transactions on Mechatronics 6(3):269\u2013285","journal-title":"Transactions on Mechatronics"},{"issue":"4","key":"1351_CR9","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1016\/j.media.2007.04.001","volume":"11","author":"E Samur","year":"2007","unstructured":"Samur E, Sedef M, Basdogan C, Avtan L, Duzgun O (2007) A robotic indenter for minimally invasive measurement and characterization of soft tissue response. Medical Image Analysis 11(4):361\u2013373","journal-title":"Medical Image Analysis"},{"issue":"1","key":"1351_CR10","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1145\/588272.588278","volume":"22","author":"DL James","year":"2003","unstructured":"James DL, Pai DK (2003) Multiresolution green\u2019s function methods for interactive simulation of large-scale elastostatic objects. ACM Trans Graphics 22(1):47\u201382","journal-title":"ACM Trans. Graphics"},{"issue":"3","key":"1351_CR11","doi-asserted-by":"crossref","first-page":"524","DOI":"10.1109\/5.662877","volume":"86","author":"E Chen","year":"1998","unstructured":"Chen E, Marcus B (1998) Force feedback for surgical simulation. Proceedings of the IEEE 86(3):524\u2013537","journal-title":"Proceedings of the IEEE"},{"issue":"4","key":"1351_CR12","doi-asserted-by":"crossref","first-page":"636","DOI":"10.1109\/TMECH.2009.2031240","volume":"15","author":"J Kim","year":"2010","unstructured":"Kim J, Janabi-Sharifi F, Kim J (2010) A haptic interaction method using visual information and physically based modeling. IEEE\/ASME Trans Mechatronics 15(4):636\u2013645","journal-title":"IEEE\/ASME Trans. Mechatronics"},{"issue":"1\/6","key":"1351_CR13","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1007\/BF01758770","volume":"7","author":"L Guibas","year":"1992","unstructured":"Guibas L, Knuth D, Sharir M (1992) Randomized incremental construction of Delaunay and Voronoi diagram. Algorithmica 7(1\/6):381\u2013413","journal-title":"Algorithmica"},{"issue":"3","key":"1351_CR14","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1109\/TOH.2009.50","volume":"3","author":"R Mafi","year":"2010","unstructured":"Mafi R, Sirouspour S, Mahdavikhah BS, Moody B, Elizeh K, Kinsman A, Nicolici N (2010) A parallel computing platform for real-time haptic interaction with deformable bodies. IEEE Trans Haptics 3(3):211\u2013223","journal-title":"IEEE Trans. Haptics"},{"key":"1351_CR15","unstructured":"Bathe K J. Finite Element Procedures. New Jersey: Prentice-Hall, 1996."},{"key":"1351_CR16","unstructured":"Shewchuk J R. An introduction to the conjugate gradient method without the agonizing pain. Technical Report, Carnegie Mellon University, USA, 1994."},{"key":"1351_CR17","unstructured":"Carter F J, Frank T G, Davies P J et al. Biomechanical testing of intra-abdominal soft tissue. In Proc. Int. Workshop. Soft Tissue Deformation and Tissue Palpation, Oct. 1998."},{"issue":"2","key":"1351_CR18","doi-asserted-by":"crossref","first-page":"021020","DOI":"10.1115\/1.2898712","volume":"130","author":"J Rosen","year":"2008","unstructured":"Rosen J, Brown JD, De S, Sinanan M, Hannaford B (2008) Biomechanical properties of abdominal organs in vivo and post-mortem under compression loads. Journal of Biomechanical Engineering 130(2):021020","journal-title":"Journal of Biomechanical Engineering"},{"key":"1351_CR19","unstructured":"Brown J D, Rosen J, Kim Y S et al. In-vivoand in-situ compressive properties of porcine abdominal soft tissues. In Medicine Meets Virtual Reality 11, Westwood J D, Hoffman H M, Mogel G T et al. (eds.), 2003, pp.26\u201332."},{"key":"1351_CR20","unstructured":"Dan D. Caracterisation mecanique du foie humain en situation de choc [Ph.D. Thesis]. Universite Paris 7, France, 1999. (In French)"},{"key":"1351_CR21","doi-asserted-by":"crossref","unstructured":"Nava A, Mazza E, Kleinermann F, Avis N, McClure J. Determination of the mechanical properties of soft human tissues through aspiration experiments. In Proc. the 6th MICCAI 2003, Nov. 2003, pp.222\u2013229.","DOI":"10.1007\/978-3-540-39899-8_28"},{"key":"1351_CR22","doi-asserted-by":"crossref","unstructured":"Ottensmeyer M P, Kerdok A E, Howe R D, Dawson S L. The effects of testing environment on the viscoelastic properties of soft tissues. In Proc. ISMS 2004, June 2004, pp.9\u201318.","DOI":"10.1007\/978-3-540-25968-8_2"},{"issue":"11","key":"1351_CR23","doi-asserted-by":"crossref","first-page":"2129","DOI":"10.1109\/TBME.2006.879474","volume":"53","author":"BK Tay","year":"2006","unstructured":"Tay BK, Kim J, Srinivasan MA (2006) In vivo mechanical behavior of intraabdominal organs. IEEE Trans Biom Eng 53(11):2129\u20132138","journal-title":"IEEE Trans. Biom. Eng."},{"issue":"2","key":"1351_CR24","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1016\/j.media.2004.11.002","volume":"9","author":"JM Schwartz","year":"2005","unstructured":"Schwartz JM, Denninger M, Rancourt D, Moisan C, Laurendeau D (2005) Modelling liver tissue properties using a non-linear visco-elastic model for surgery simulation. Medical Image Analysis 9(2):103\u2013112","journal-title":"Medical Image Analysis"},{"key":"1351_CR25","unstructured":"Kim Y J, Park S H, Kim L H et al. Multi-model structure and mapping method of liver model. In Proc Korean Society for Precision Engineering, May 2010."},{"issue":"1","key":"1351_CR26","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1111\/j.1467-8659.2005.00829.x","volume":"24","author":"M Teschner","year":"2005","unstructured":"Teschner M, Kimmerle S, Zachmann G et al (2005) Collision detection for deformable objects. Computer Graphics Forum 24(1):61\u201381","journal-title":"Computer Graphics Forum"},{"key":"1351_CR27","doi-asserted-by":"crossref","unstructured":"Kim Y J, Koo S O, Lee D H et al. Mesh-to-mesh collision detection by ray tracing for medical simulation with deformable bodies. In Proc. CyberWorlds, Oct. 2010, pp.60\u201366.","DOI":"10.1109\/CW.2010.10"},{"key":"1351_CR28","first-page":"74","volume":"85","author":"CD Bruyns","year":"2002","unstructured":"Bruyns CD, Montgomery K (2002) Generalized interactions using virtual tools within the spring framework: Probing, piercing, cauterizing and ablating. Studies in Health Technology and Informatics 85:74\u201378","journal-title":"Studies in Health Technology and Informatics"},{"issue":"9","key":"1351_CR29","doi-asserted-by":"crossref","first-page":"1384","DOI":"10.3748\/wjg.v13.i9.1384","volume":"13","author":"X Luo","year":"2007","unstructured":"Luo X, Li W, Bird N, Chin SB, Hill NA, Johnson AG (2007) On the mechanical behavior of the human biliary system. World Journal of Gastroenterology 13(9):1384\u20131392","journal-title":"World Journal of Gastroenterology"}],"container-title":["Journal of Computer Science and Technology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11390-013-1351-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11390-013-1351-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11390-013-1351-3","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,7,13]],"date-time":"2019-07-13T08:14:23Z","timestamp":1563005663000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11390-013-1351-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,5]]},"references-count":29,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2013,5]]}},"alternative-id":["1351"],"URL":"https:\/\/doi.org\/10.1007\/s11390-013-1351-3","relation":{},"ISSN":["1000-9000","1860-4749"],"issn-type":[{"value":"1000-9000","type":"print"},{"value":"1860-4749","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,5]]}}}