{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,8,1]],"date-time":"2024-08-01T23:29:44Z","timestamp":1722554984643},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2011,9,15]],"date-time":"2011-09-15T00:00:00Z","timestamp":1316044800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sci. China Inf. Sci."],"published-print":{"date-parts":[[2011,10]]},"DOI":"10.1007\/s11432-011-4384-7","type":"journal-article","created":{"date-parts":[[2011,9,14]],"date-time":"2011-09-14T10:37:25Z","timestamp":1315996645000},"page":"2199-2208","source":"Crossref","is-referenced-by-count":4,"title":["Silicon-based microelectrode arrays for stimulation and signal recording of in vitro cultured neurons"],"prefix":"10.1007","volume":"54","author":[{"given":"HaiXian","family":"Pan","sequence":"first","affiliation":[]},{"given":"XiaoYing","family":"L\u00fc","sequence":"additional","affiliation":[]},{"given":"ZhiGong","family":"Wang","sequence":"additional","affiliation":[]},{"given":"TianLing","family":"Ren","sequence":"additional","affiliation":[]},{"given":"Tao","family":"Fang","sequence":"additional","affiliation":[]},{"given":"Jie","family":"Zhang","sequence":"additional","affiliation":[]},{"given":"ChangJian","family":"Zhou","sequence":"additional","affiliation":[]},{"given":"LiGang","family":"Wang","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2011,9,15]]},"reference":[{"key":"4384_CR1","doi-asserted-by":"crossref","first-page":"796","DOI":"10.1038\/423796a","volume":"423","author":"H. Hoag","year":"2003","unstructured":"Hoag H, Neuroengineering: Remot control. Nature, 2003, 423: 796\u2013798","journal-title":"Nature"},{"key":"4384_CR2","doi-asserted-by":"crossref","first-page":"2306","DOI":"10.1109\/JSSC.2003.819174","volume":"38","author":"B. Eversmann","year":"2003","unstructured":"Eversmann B, Jenkner M, Hofmann F, et al. A 128 \u00d7 128 CMOS biosensor array for extracellular recording of neural activity. IEEE J Solid State Circuit, 2003, 38: 2306\u20132317","journal-title":"IEEE J Solid State Circuit"},{"key":"4384_CR3","doi-asserted-by":"crossref","first-page":"1620","DOI":"10.1109\/JSSC.2006.873677","volume":"41","author":"F. Heer","year":"2006","unstructured":"Heer F, Hafizovic S, Franks W, et al. CMOS microelectrode array for bidirectional interaction with neuronal networks. IEEE J Solid State Circuits, 2006, 41: 1620\u20131629","journal-title":"IEEE J Solid State Circuits"},{"key":"4384_CR4","doi-asserted-by":"crossref","first-page":"2478","DOI":"10.1016\/j.bios.2006.09.026","volume":"22","author":"G. X. Xiang","year":"2007","unstructured":"Xiang G X, Pan L B, Huang L H, et al. Microelectrode array-based system for neuropharmacological applications with cortical neurons cultured in vitro. Biosens Bioelectron, 2007, 22: 2478\u20132484","journal-title":"Biosens Bioelectron"},{"key":"4384_CR5","first-page":"168","volume-title":"The neuron cell and molecular biology","author":"I. B. Levitan","year":"1997","unstructured":"Levitan I B, Kaczmarek L K. The neuron cell and molecular biology. New York: Oxford University Press, 1997. 168\u2013169"},{"key":"4384_CR6","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1038\/260799a0","volume":"260","author":"E. Neher","year":"1976","unstructured":"Neher E, Sakmann B. Single-channel currents recorded from membrane of denervated frog muscle fibres. Nature, 1976, 260: 799\u2013802","journal-title":"Nature"},{"key":"4384_CR7","first-page":"253","volume":"3","author":"K. Cole","year":"1968","unstructured":"Cole K. Dynamic electrical characteristics of the squid axon membrane. Arch Sci Physiol, 1968, 3: 253\u2013258","journal-title":"Arch Sci Physiol"},{"key":"4384_CR8","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/0014-4827(72)90481-8","volume":"74","author":"C. A. Thomas","year":"1972","unstructured":"Thomas C A, Springer P A, Loeb G E, et al. A miniature microelectrode array to monitor the bioelectrical activity of cultured cells. Exp Cell Res, 1972, 74: 61\u201366","journal-title":"Exp Cell Res"},{"key":"4384_CR9","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/0304-3940(77)90003-9","volume":"6","author":"G. W. Gross","year":"1977","unstructured":"Gross G W, Rieske E, Kreutzberg G W, et al. A new fixedarray multi-microelectrode system designed for long-term monitoring of extracellular single unit neuronal activity in vitro. Neurosci Lett, 1977, 6: 101\u2013105","journal-title":"Neurosci Lett"},{"key":"4384_CR10","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/0165-0270(80)90042-4","volume":"2","author":"J. Pine","year":"1980","unstructured":"Pine J. Recording action potentials from cultured neurons with extracellular microcircuit electrodes. J Neurosci Methods, 1980, 2: 19\u201331","journal-title":"J Neurosci Methods"},{"key":"4384_CR11","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/j.neuro.2010.04.001","volume":"31","author":"A. F. M. Johnstone","year":"2010","unstructured":"Johnstone A F M, Gross G W, Weiss D G, et al. Microelectrode arrays: A physiologically based neurotoxicity testing platform for the 21st century. NeuroToxicology, 2010, 31: 331\u2013350","journal-title":"NeuroToxicology"},{"key":"4384_CR12","doi-asserted-by":"crossref","first-page":"2212","DOI":"10.1016\/j.bios.2010.02.024","volume":"25","author":"Q. J. Liu","year":"2010","unstructured":"Liu Q J, Ye W W, Xiao L D, et al. Extracellular potentials recording in intact olfactory epithelium by microelectrode array for a bioelectronic nose. Biosens Bioelectron, 2010, 25: 2212\u20132217","journal-title":"Biosens Bioelectron"},{"key":"4384_CR13","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1016\/j.jneumeth.2009.10.007","volume":"185","author":"A. J. Hill","year":"2010","unstructured":"Hill A J, Jones N A, Williams C M, et al. Development of multi-electrode array screening for anticonvulsants in acute rat brain slices. J Neurosci Meth, 2010, 185: 246\u2013256","journal-title":"J Neurosci Meth"},{"key":"4384_CR14","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1016\/j.jneumeth.2008.10.032","volume":"177","author":"L. Berdondini","year":"2009","unstructured":"Berdondini L, Massobrio P, Chiappalone M, et al. Extracellular recordings from locally dense microelectrode arrays coupled to dissociated cortical cultures. J Neurosci Meth, 2009, 177: 386\u2013396","journal-title":"J Neurosci Meth"},{"key":"4384_CR15","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1016\/j.jneumeth.2009.05.003","volume":"181","author":"F. Gullo","year":"2009","unstructured":"Gullo F, Maffezzoli A, Dossi E, et al. Short-latency cross- and autocorrelation identify clusters of interacting cortical neurons recorded from multi-electrode array. J Neurosci Meth, 2009, 181: 186\u2013198","journal-title":"J Neurosci Meth"},{"key":"4384_CR16","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1016\/j.bios.2004.02.006","volume":"20","author":"F. Heer","year":"2004","unstructured":"Heer F, Franks W, Blau A, et al. CMOS microelectrode array for the monitoring of electrogenic cells, Biosens Bioelectron, 2004, 20: 358\u2013386","journal-title":"Biosens Bioelectron"},{"key":"4384_CR17","doi-asserted-by":"crossref","unstructured":"Frey U, Heer F, Pedron R, et al. An 11k-electrode 126-channel high-density microelectrode array to interact with electrogenic cells. In: IEEE International on Solid-State Circuits Conference, San Francisco, 2007, 158\u2013160","DOI":"10.1109\/ISSCC.2007.373636"},{"key":"4384_CR18","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1016\/j.irbm.2009.10.011","volume":"30","author":"R. Guillemaud","year":"2009","unstructured":"Guillemaud R., B\u00eache J F, Billoint O, et al. A Multi-channel platform for recording and stimulation of large neuronal structures. IRBM, 2009, 30: 226\u2013233","journal-title":"IRBM"},{"key":"4384_CR19","first-page":"468","volume":"39","author":"H. X. Pan","year":"2009","unstructured":"Pan H X, L\u00fc X Y, Wang Z G, et al, Microelectrode array for detecting electrical activities of neuron assemble. J Southeast University (Natural Science Edition) (in Chinese), 2009, 39: 468\u2013472","journal-title":"J Southeast University (Natural Science Edition) (in Chinese)"},{"key":"4384_CR20","doi-asserted-by":"crossref","first-page":"1911","DOI":"10.1016\/j.bios.2008.09.027","volume":"24","author":"C. H. Chen","year":"2009","unstructured":"Chen C H, Yao D J, Tseng S H, et al. Micro-multi-probe electrode array to measure neural signals. Biosens Bioelectron, 2009, 24: 1911\u20131917","journal-title":"Biosens Bioelectron"},{"key":"4384_CR21","doi-asserted-by":"crossref","first-page":"1757","DOI":"10.1016\/j.bios.2004.06.037","volume":"20","author":"G. X. Xu","year":"2005","unstructured":"Xu G X, Ye X S, Qin L F, et al. Cell-based biosensors based on light-addressable potentiometric sensors for single cell monitoring. Biosens Bioelectron, 2005, 20: 1757\u20131763","journal-title":"Biosens Bioelectron"},{"key":"4384_CR22","first-page":"183","volume":"10","author":"H. Yao","year":"1994","unstructured":"Yao H, Ding F Z, Liu A S, et al. Detecting physiological parameters of hippocampal neurons cultured in vitro and the monitoring the effect of neurotransmitter. Chin J Appl Physiol, 1994, 10: 183\u2013185","journal-title":"Chin J Appl Physiol"},{"key":"4384_CR23","doi-asserted-by":"crossref","first-page":"2391","DOI":"10.1007\/s11431-008-0176-8","volume":"25","author":"J. H. Lin","year":"2009","unstructured":"Lin J H, Wu X M, Huang P S, et al. Development of silicon-based microelectrode array, Sci China Ser E-Tech Sci, 2009, 25: 2391\u20132395","journal-title":"Sci China Ser E-Tech Sci"},{"key":"4384_CR24","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1088\/0960-1317\/12\/4\/312","volume":"12","author":"P. Norlin","year":"2002","unstructured":"Norlin P, Kindlundh M, Mouroux A, et al. A 32-site neural recording probe fabricated by DRIE of SOI substrates. J Micromech Microeng, 2002, 12: 414\u2013419","journal-title":"J Micromech Microeng"},{"key":"4384_CR25","doi-asserted-by":"crossref","first-page":"1462","DOI":"10.1016\/j.bios.2008.08.045","volume":"24","author":"H. Yu","year":"2009","unstructured":"Yu H, Cai H, Zhang W, et al. A novel design of multifunctional integrated cell-based biosensors for simultaneously detecting cell acidification and extracellular potential. Biosens Bioelectron, 2009, 24: 1462\u20131468","journal-title":"Biosens Bioelectron"},{"key":"4384_CR26","doi-asserted-by":"crossref","first-page":"2171","DOI":"10.1103\/PhysRevE.60.2171","volume":"60","author":"C. Spr\u00f6ssler","year":"1999","unstructured":"Spr\u00f6ssler C, Denyer M, Britland S, et al. Electrical recordings from rat cardiac muscle cells using field-effect transistors, Phys Rev E, 1999, 60: 2171\u20132176","journal-title":"Phys Rev E"},{"key":"4384_CR27","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/S1056-8719(01)00150-2","volume":"45","author":"C. K. Yeung","year":"2001","unstructured":"Yeung C K, Ingebrandt S, Krause M, et al. Validation of the use of field effect transistors for extracellular signal recording in pharmacyological bioassays. J Pharmacol Toxicol Methods, 2001, 45: 207\u2013214","journal-title":"J Pharmacol Toxicol Methods"}],"container-title":["Science China Information Sciences"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11432-011-4384-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11432-011-4384-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11432-011-4384-7","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,15]],"date-time":"2019-06-15T13:51:39Z","timestamp":1560606699000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11432-011-4384-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,9,15]]},"references-count":27,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2011,10]]}},"alternative-id":["4384"],"URL":"https:\/\/doi.org\/10.1007\/s11432-011-4384-7","relation":{},"ISSN":["1674-733X","1869-1919"],"issn-type":[{"value":"1674-733X","type":"print"},{"value":"1869-1919","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,9,15]]}}}