{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T23:40:11Z","timestamp":1790984411028,"version":"4.1.0"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2006,6,20]],"date-time":"2006-06-20T00:00:00Z","timestamp":1150761600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Med Bio Eng Comput"],"published-print":{"date-parts":[[2006,7]]},"DOI":"10.1007\/s11517-006-0065-x","type":"journal-article","created":{"date-parts":[[2006,6,19]],"date-time":"2006-06-19T12:05:44Z","timestamp":1150718744000},"page":"569-582","source":"Crossref","is-referenced-by-count":70,"title":["Empirical mode decomposition: a novel technique for the study of tremor time series"],"prefix":"10.1007","volume":"44","author":[{"given":"Eduardo Rocon","family":"de Lima","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adriano O.","family":"Andrade","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos\u00e9 Luis","family":"Pons","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Kyberd","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Slawomir J.","family":"Nasuto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2006,6,20]]},"reference":[{"key":"65_CR1","volume-title":"Biomedical signal processing","author":"M Akay","year":"1994","unstructured":"Akay M (1994) Biomedical signal processing, 1st edn. Academic, Sandiego","edition":"1st edn."},{"key":"65_CR2","volume-title":"Detection and estimation methods for biomedical signals","author":"M Akay","year":"1999","unstructured":"Akay M (1999) Detection and estimation methods for biomedical signals. Academic, San Diego"},{"key":"65_CR3","unstructured":"Andrade AO (2005) Decomposition and analysis of electromyographic signals. PhD thesis, University of Reading, Reading"},{"key":"65_CR4","doi-asserted-by":"crossref","unstructured":"Andrade AO, Kyberd PJ, Taffler SD (2003) A novel spectral representation of electromyographic signals. In: Leder RS (ed) Engineering in medicine and biology society\u201425th annual international conference, Cancun, Mexico, vol 1, IEEE, pp 2598\u20132601","DOI":"10.1109\/IEMBS.2003.1280447"},{"key":"65_CR5","unstructured":"Ang WT (2004) Active Control compensation in Handheld Instrument for Microsurgery. PhD thesis, Johns Hopkins University"},{"issue":"6","key":"65_CR6","first-page":"523","volume":"162","author":"A Anouti","year":"1998","unstructured":"Anouti A, Koller W (1998) Tremor disorders: diagnosis and management. West J Med 162(6):523\u2013530","journal-title":"West J Med"},{"key":"65_CR7","unstructured":"Belda-Lois JM, Sanchez-Lacuesta J, Vivas-Broseta MJ, Rocon E, Bueno L, Pons JL (2003) Tremor movement analysis techniques: an approach towards ambulatory systems. Assistive technology\u2014shaping the future, pp 827\u2013831"},{"key":"65_CR8","volume-title":"Introduction to Hilbert spaces with applications","author":"L Debnath","year":"1999","unstructured":"Debnath L, Mikusinski P (1999) Introduction to Hilbert spaces with applications, 2nd edn. Academic, San Diego","edition":"2nd edn."},{"issue":"1","key":"65_CR9","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1097\/00004691-200001000-00009","volume":"17","author":"R Edwards","year":"1999","unstructured":"Edwards R, Beuter A (1999) Using time domain characteristics to discriminate physiologic and parkinsonian tremors. J Clin Neurophysiol 17(1):87\u2013100","journal-title":"J Clin Neurophysiol"},{"key":"65_CR10","doi-asserted-by":"crossref","first-page":"484","DOI":"10.1097\/00004691-199909000-00010","volume":"16","author":"R Edwards","year":"1999","unstructured":"Edwards R, Beuter A (1999) Using time frequency characteristics to discriminate physiologic and parkinsonian tremors. J Clin Neurophysiol 16:484\u2013494","journal-title":"J Clin Neurophysiol"},{"key":"65_CR11","first-page":"405","volume-title":"Movement disorders: neurologic principles and practice","author":"RJ Elble","year":"1997","unstructured":"Elble RJ (1997) The pathophysiology of tremor. In: Watts RL, Koller WC (eds) Movement disorders: neurologic principles and practice. McGraw-Hill, New York, pp 405\u2013417"},{"key":"65_CR12","volume-title":"Tremor","author":"RJ Elble","year":"1990","unstructured":"Elble RJ, Koller WC (1990) Tremor. The Johns Hopkins University Press, Baltimore"},{"key":"65_CR13","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1016\/S1388-2457(03)00006-3","volume":"114","author":"RJ Elble","year":"2003","unstructured":"Elble RJ (2003) Characteristics of physiologic tremor in young and elderly adults. Clin Neurophysiol 114:624\u2013635","journal-title":"Clin Neurophysiol"},{"key":"65_CR14","volume-title":"Parkinson\u2019s disease and movement disorders","author":"S Fahn","year":"1998","unstructured":"Fahn S, Tolosa E, Marin C (1998) Clinical rating scale for tremor. In: Tolosa E, Jankovic J (eds) Parkinson\u2019s disease and movement disorders. Urban & Schwarzenberg, Baltimore"},{"key":"65_CR15","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1007\/BF00204112","volume":"66","author":"C Gantert","year":"1992","unstructured":"Gantert C, Honerkamp J, Timmer J (1992) Analysing the dynamics of tremor time series. Biol Cybern 66:479\u2013484","journal-title":"Biol Cybern"},{"key":"65_CR16","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1007\/s00422-001-0296-8","volume":"86","author":"JB Gao","year":"2002","unstructured":"Gao JB, Wen-wen T (2002) Pathological tremors as diffusional processes. Biol Cybern 86:263\u2013270","journal-title":"Biol Cybern"},{"issue":"5","key":"65_CR17","doi-asserted-by":"crossref","first-page":"1310","DOI":"10.1785\/0120000735","volume":"91","author":"NE Huang","year":"2001","unstructured":"Huang NE, Chern CC, Huang K, Salvino LW, Long SR, Fan KL (2001) A new spectral representation of earthquake data: Hilbert spectral analysis of station TCU129, Chi-Chi, Taiwan, 21 September 1999. Bull Seismol Soc Am 91(5):1310\u20131338","journal-title":"Bull Seismol Soc Am"},{"key":"65_CR18","doi-asserted-by":"crossref","first-page":"903","DOI":"10.1098\/rspa.1998.0193","volume":"454","author":"NE Huang","year":"1998","unstructured":"Huang NE, Shen Z, Long SR, Wu MC, Shih HH, Zheng Q, Yen N-C, Tung CC, Liu HH (1998) The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysis. Proc Roy Soc Lond 454:903\u2013995","journal-title":"Proc Roy Soc Lond"},{"key":"65_CR19","unstructured":"Jain SS, Kirshblum SC (1993) Movement disorders, including tremors. In: Joel A, DeLisa JB (eds) Rehabilitation medicine: principles and practice, vol 2. Lippincott, Philadelphia"},{"key":"65_CR20","unstructured":"Kapandji IA (1983) The physiology of the joints: upper limb, vol 1. Churchill Livingstone, London"},{"issue":"9","key":"65_CR21","doi-asserted-by":"crossref","first-page":"2600","DOI":"10.1109\/78.782222","volume":"47","author":"LS Marple Jr","year":"1999","unstructured":"Marple LS Jr (1999) Computing the discrete-time \"analytic\" signal via fft. IEEE Trans Signal Process 47(9):2600\u20132603","journal-title":"IEEE Trans Signal Process"},{"key":"65_CR22","unstructured":"Moreno JC, Freriks B, Thorsteinsson F, Sanchez J, Pons JL (2004) Intelligent knee\u2013ankle\u2013foot orthosis: the gait project approach. Rehabilitation sciences in the new millenium\u2014challenge for multidisciplinary research, pp 271\u2013274"},{"key":"65_CR23","unstructured":"Nechyba MC (1998) Learning and validation of human control strategies. PhD thesis, Johns Hopkins University, Baltimore"},{"key":"65_CR24","unstructured":"Riviere C (1981) Adaptive suppression of tremor for improved human\u2013machine control. PhD thesis, Johns Hopkins University, Baltimore"},{"key":"65_CR25","doi-asserted-by":"crossref","first-page":"3","DOI":"10.3233\/TAD-2004-16102","volume":"16","author":"E Rocon","year":"2004","unstructured":"Rocon E, Belda-Lois JM, Sanchez-Lacuesta JJ, Pons JL (2004) Pathological tremor management: modelling,compensatory technology and evaluation. Technol Disabil 16:3\u201318","journal-title":"Technol Disabil"},{"key":"65_CR26","unstructured":"Rocon E, Ruiz AF, Pons JL (2005) On the use of rate gyroscopes for tremor sensing in the human upper limb. In: Proceedings of the international conference eurosensors XIX, p MP30"},{"key":"65_CR27","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1007\/BF00202568","volume":"70","author":"J Timmer","year":"1993","unstructured":"Timmer J, Gantert C, Deuschl G, Honerkamp J (1993) Characteristics of hand tremor time series. Biol Cybern 70:75\u201380","journal-title":"Biol Cybern"},{"key":"65_CR28","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1007\/s004220050439","volume":"78","author":"J Timmer","year":"1998","unstructured":"Timmer J, Haubler S, Lauk M, Lucking CH (1998) Pathological tremors: deterministic chaos or nonlinear stochastic oscillators? Biol Cybern 78:349\u2013357","journal-title":"Biol Cybern"},{"key":"65_CR29","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1007\/s004220050439","volume":"78","author":"J Timmer","year":"1998","unstructured":"Timmer J, Lauk M, Deuschl G (1998) Cross-spectral analysis of physiological tremor and muscle activity. I. Theory and application to unsynchronized electromyogram. Biol Cybern 78:349\u2013357","journal-title":"Biol Cybern"},{"key":"65_CR30","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/S1350-4533(99)00030-2","volume":"21","author":"K Tong","year":"1999","unstructured":"Tong K, Granat MH (1999) A practical gait analysis system using gyroscopes. Med Eng Phys 21:87\u201394","journal-title":"Med Eng Phys"},{"key":"65_CR31","unstructured":"Viosca E, Peydro MF, Puchol A, Soler C, Prat J, Corts A, Sanchez J, Belda JM, Lafuente R, Poveda R (1999) Gufa de uso y prescripci=n de productos ortoprotTsicos a medida. IBV\u2014Instituto Biomec\u00e1nico de Valencia"}],"container-title":["Medical and Biological Engineering and Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-006-0065-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11517-006-0065-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-006-0065-x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,4,15]],"date-time":"2020-04-15T15:27:22Z","timestamp":1586964442000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11517-006-0065-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,6,20]]},"references-count":31,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2006,7]]}},"alternative-id":["65"],"URL":"https:\/\/doi.org\/10.1007\/s11517-006-0065-x","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2006,6,20]]}}}