{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T09:58:25Z","timestamp":1769162305127,"version":"3.49.0"},"reference-count":68,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2007,3,6]],"date-time":"2007-03-06T00:00:00Z","timestamp":1173139200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2007,3,6]],"date-time":"2007-03-06T00:00:00Z","timestamp":1173139200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Bio Eng Comput"],"published-print":{"date-parts":[[2007,5]]},"DOI":"10.1007\/s11517-007-0170-5","type":"journal-article","created":{"date-parts":[[2007,3,5]],"date-time":"2007-03-05T16:17:13Z","timestamp":1173111433000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":126,"title":["Laser Doppler perfusion monitoring and imaging: novel approaches"],"prefix":"10.1007","volume":"45","author":[{"given":"Anne","family":"Humeau","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wiendelt","family":"Steenbergen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Henrik","family":"Nilsson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomas","family":"Str\u00f6mberg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2007,3,6]]},"reference":[{"key":"170_CR1","first-page":"17","volume-title":"Laser Doppler","author":"N Almond","year":"1994","unstructured":"Almond N (1994) Laser Doppler flowmetry: theory and practice. In: Belcaro GV, Hoffman U, Bollinger A, Nicolaides AN (eds) Laser Doppler. Med-Orion, London, pp. 17\u201332"},{"key":"170_CR2","unstructured":"Belcaro GV, Hoffman U, Bollinger A, Nicolaides AN (eds) (1994) Laser Doppler. Med-Orion, London"},{"key":"170_CR3","doi-asserted-by":"crossref","first-page":"2097","DOI":"10.1364\/AO.20.002097","volume":"20","author":"RF Bonner","year":"1981","unstructured":"Bonner RF, Nossal R (1981) Model for laser Doppler measurements of blood flow in tissue. Appl Opt 20:2097\u20132107","journal-title":"Appl Opt"},{"key":"170_CR4","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1007\/978-1-4757-2083-9_2","volume-title":"Laser-Doppler blood flowmetry","author":"RF Bonner","year":"1990","unstructured":"Bonner RF, Nossal R (1990) Principles of laser-Doppler flowmetry. In: Shepherd AP, \u00d6berg P\u00c5 (eds) Laser-Doppler blood flowmetry. Kluwer, Massachusetts, pp 17\u201345"},{"key":"170_CR5","first-page":"3","volume-title":"Laser Doppler","author":"J Borgos","year":"1994","unstructured":"Borgos J (1994) Principles of instrumentation: calibration and technical issues. In: Belcaro GV, Hoffman U, Bollinger A, Nicolaides AN (eds) Laser Doppler. Med-Orion, London, pp 3\u201316"},{"key":"170_CR6","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1088\/0967-3334\/21\/4\/302","volume":"21","author":"M Bracic Lotric","year":"2000","unstructured":"Bracic Lotric M, Stefanovska A, Stajer D, Urbancic-Rovan V (2000) Spectral components of heart rate variability determined by wavelet analysis. Physiol Meas 21:441\u2013457","journal-title":"Physiol Meas"},{"key":"170_CR7","doi-asserted-by":"publisher","first-page":"919","DOI":"10.1006\/bulm.1998.0047","volume":"60","author":"M Bracic","year":"1998","unstructured":"Bracic M, Stefanovska A (1998) Wavelet-based analysis of human blood-flow dynamics. B Math Biol 60:919\u2013935","journal-title":"B Math Biol"},{"key":"170_CR8","first-page":"68","volume":"2","author":"M Bracic","year":"1999","unstructured":"Bracic M, Stefanovska A (1999) Wavelet analysis in studying the dynamics of blood circulation. Nonlinear Phenom Complex Syst 2:68\u201377","journal-title":"Nonlinear Phenom Complex Syst"},{"key":"170_CR9","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1117\/1.429903","volume":"4","author":"JD Briers","year":"1999","unstructured":"Briers JD, Richards G, He XW (1999) Capillary blood flow monitoring by laser speckle contrast analysis (Lasca). J Biomed Opt 4:164\u2013175","journal-title":"J Biomed Opt"},{"key":"170_CR10","doi-asserted-by":"crossref","unstructured":"Cummins HZ, Swinney HL (1970) Light beating spectroscopy. In: Wolf E (ed) Progress in optics. North-Holland, Amsterdam, pp 135\u2013200","DOI":"10.1016\/S0079-6638(08)70188-4"},{"key":"170_CR11","doi-asserted-by":"publisher","first-page":"439","DOI":"10.1109\/TBME.1985.325452","volume":"32","author":"L Duteil","year":"1985","unstructured":"Duteil L, Bernengo J, Schalla W (1985) A double wavelength laser Doppler system to investigate skin microcirculation. IEEE Trans Biomed Eng BME 32:439\u2013447","journal-title":"IEEE Trans Biomed Eng BME"},{"key":"170_CR12","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1016\/0141-5425(91)90125-Q","volume":"13","author":"TJ Essex","year":"1991","unstructured":"Essex TJ, Byrne PO (1991) A laser Doppler scanner for imaging blood flow in skin. J Biomed Eng 13:189\u2013194","journal-title":"J Biomed Eng"},{"key":"170_CR13","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1364\/JOSA.51.000253","volume":"51","author":"AT Forrester","year":"1961","unstructured":"Forrester AT (1961) Photoelectric mixing as a spectroscopic tool. J Opt Soc Am 51:253\u2013259","journal-title":"J Opt Soc Am"},{"key":"170_CR14","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1007\/BF02345307","volume":"40","author":"KR Forrester","year":"2002","unstructured":"Forrester KR, Stewart C, Tulip J, Leonard C, Bray RC (2002) Comparison of laser speckle and laser Doppler perfusion imaging: measurement in human skin and rabbit articular tissue. Med Biol Eng Comput 40:687\u2013697","journal-title":"Med Biol Eng Comput"},{"key":"170_CR15","doi-asserted-by":"publisher","first-page":"2074","DOI":"10.1109\/TBME.2004.834259","volume":"51","author":"KR Forrester","year":"2004","unstructured":"Forrester KR, Tulip J, Leonard C, Stewart C, Bray RC (2004) A laser speckle imaging technique for measuring tissue perfusion. IEEE Trans Biomed Eng 51:2074\u20132084","journal-title":"IEEE Trans Biomed Eng"},{"key":"170_CR16","doi-asserted-by":"crossref","unstructured":"Fredriksson I, Larsson M, Str\u00f6mberg T (2006) Absolute flow velocity components in laser Doppler flowmetry. In: Proceedings of SPIE, San Jos\u00e9, CA, vol 6094, 60940A, 12 p","DOI":"10.1117\/12.659206"},{"key":"170_CR17","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1016\/S0006-8993(98)00973-1","volume":"811","author":"B Fromy","year":"1998","unstructured":"Fromy B, Abraham P, Saumet JL (1998) Non-nociceptive capsaicin-sensitive nerve terminal stimulation allows for an original vasodilatory reflex in the human skin. Brain Res 811:166\u2013168","journal-title":"Brain Res"},{"key":"170_CR18","doi-asserted-by":"publisher","first-page":"1161","DOI":"10.1038\/sj.bjp.0703685","volume":"131","author":"B Fromy","year":"2000","unstructured":"Fromy B, Merzeau S, Abraham P, Saumet JL (2000) Mechanisms of the cutaneous vasodilator response to local external pressure application in rats: involvement of CGRP, neurokinins, prostaglandins and NO. Br J Pharmacol 131:1161\u20131171","journal-title":"Br J Pharmacol"},{"key":"170_CR19","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1016\/S1385-299X(00)00013-1","volume":"5","author":"B Fromy","year":"2000","unstructured":"Fromy B, Abraham P and Saumet JL (2000) Progressive calibrated pressure device to measure cutaneous blood flow changes to external pressure strain. Brain Res Protoc 5:198\u2013203","journal-title":"Brain Res Protoc"},{"key":"170_CR20","doi-asserted-by":"publisher","first-page":"1214","DOI":"10.2337\/diabetes.51.4.1214","volume":"51","author":"B Fromy","year":"2002","unstructured":"Fromy B, Abraham P, Bouvet C, Bouhanick B, Fressinaud P, Saumet JL (2002) Early decrease of skin blood flow in response to locally applied pressure in diabetic subjects. Diabetes 51:1214\u20131217","journal-title":"Diabetes"},{"key":"170_CR21","doi-asserted-by":"publisher","first-page":"797","DOI":"10.1682\/JRRD.2003.10.0159","volume":"41","author":"MJ Geyer","year":"2004","unstructured":"Geyer MJ, Jan YK, Brienza DM, Boninger ML (2004) Using wavelet analysis to characterize the thermoregulatory mechanisms of sacral skin blood flow. J Rehabil Res Dev 41:797\u2013806","journal-title":"J Rehabil Res Dev"},{"key":"170_CR22","doi-asserted-by":"publisher","first-page":"1463","DOI":"10.1088\/0031-9155\/29\/12\/001","volume":"29","author":"RJ Gush","year":"1984","unstructured":"Gush RJ, King TA, Jayson MI (1984) Aspects of laser light scattering from skin tissue with application to laser Doppler blood flow measurement. Phys Med Biol 29:1463\u20131476","journal-title":"Phys Med Biol"},{"key":"170_CR23","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1111\/1523-1747.ep12507665","volume":"69","author":"GA Holloway","year":"1977","unstructured":"Holloway GA, Watkins DW (1977) Laser Doppler measurement of cutaneous blood flow. J Invest Dermatol 69:306\u2013309","journal-title":"J Invest Dermatol"},{"key":"170_CR24","doi-asserted-by":"crossref","unstructured":"Humeau A, Koitka A, Saumet J L and L\u2019Huillier JP (2003) Dynamic characteristics of the cutaneous vasodilator response to a local external pressure application detected by the laser Doppler flowmetry technique on anaesthetised rats. In: Boas DA (ed) Photon migration and diffuse-light imaging. Proceedings of SPIE-OSA biomedical optics, SPIE 5138, pp 72\u201379","DOI":"10.1364\/ECBO.2003.5138_72"},{"key":"170_CR25","doi-asserted-by":"publisher","first-page":"843","DOI":"10.1088\/0031-9155\/49\/5\/014","volume":"49","author":"A Humeau","year":"2004","unstructured":"Humeau A, Ko\u00eftka A, Abraham P, Saumet JL, L\u2019Huillier JP (2004) Time-frequency analysis of laser Doppler flowmetry signals recorded in response to a progressive pressure applied locally on anaesthetised healthy rats. Phys Med Biol 49:843\u2013857","journal-title":"Phys Med Biol"},{"key":"170_CR26","doi-asserted-by":"publisher","first-page":"3957","DOI":"10.1088\/0031-9155\/49\/17\/009","volume":"49","author":"A Humeau","year":"2004","unstructured":"Humeau A, Ko\u00eftka A, Abraham P, Saumet JL, L\u2019Huillier JP (2004) Spectral components of laser Doppler flowmetry signals recorded in healthy and type 1 diabetic subjects at rest and during a local and progressive cutaneous pressure application: scalogram analyses. Phys Med Biol 49:3957\u20133970","journal-title":"Phys Med Biol"},{"key":"170_CR27","doi-asserted-by":"crossref","unstructured":"Humeau A, Ko\u00eftka A, Abraham P, Saumet JL, L\u2019Huillier JP (2004) Dynamic characteristics of laser Doppler flowmetry signals obtained in response to a local and progressive pressure applied on diabetic and healthy subjects. In: Wyrowski F (ed) Photon management. Proceedings of SPIE, vol 5456, SPIE, Bellingham, WA, pp 307\u2013314","DOI":"10.1117\/12.544076"},{"key":"170_CR28","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1109\/TBME.2003.820371","volume":"51","author":"A Humeau","year":"2004","unstructured":"Humeau A, Fizanne L, Garry A, Saumet JL, L\u2019Huillier JP (2004) Signal processing methodology to study the cutaneous vasodilator response to a local external pressure application detected by laser Doppler flowmetry. IEEE Trans Biomed Eng 51:190\u2013192","journal-title":"IEEE Trans Biomed Eng"},{"key":"170_CR29","first-page":"219","volume":"10","author":"K Johansson","year":"1991","unstructured":"Johansson K, Jakobsson A, Lindahl K, Lindhagen J, Lundgren O, Nilsson GE (1991) Influence of fibre diameter and probe geometry on the measuring depth of laser Doppler flowmetry in the gastrointestinal application. Int J Microcirc Clin Exp 10:219\u2013229","journal-title":"Int J Microcirc Clin Exp"},{"key":"170_CR30","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1111\/j.1365-4362.1993.tb04270.x","volume":"32","author":"RS Kirsner","year":"1993","unstructured":"Kirsner RS, Haiken M, Garland LD (1993) Margin assessment of selected basal cell carcinomas utilizing laser Doppler velocimetry. Int J Dermatol 32:290\u2013292","journal-title":"Int J Dermatol"},{"key":"170_CR31","doi-asserted-by":"publisher","first-page":"721","DOI":"10.2337\/diabetes.53.3.721","volume":"53","author":"A Ko\u00eftka","year":"2004","unstructured":"Ko\u00eftka A, Abraham P, Bouhanick B, Sigaudo-Roussel D, Demiot C, Saumet JL (2004) Impaired pressure-induced vasodilation at the foot in young adults with type 1 diabetes. Diabetes 53:721\u2013725","journal-title":"Diabetes"},{"key":"170_CR32","doi-asserted-by":"crossref","unstructured":"Kvandal P, Landsverk SA, Bernjak A, Stefanovska A, Kvernmo HD, Kirkeboen KA (2006) Low-frequency oscillations of the laser Doppler perfusion signal in human skin. Microvasc Res PMID: 16854436","DOI":"10.1016\/j.mvr.2006.05.006"},{"key":"170_CR33","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1006\/mvre.1998.2108","volume":"56","author":"HD Kvernmo","year":"1998","unstructured":"Kvernmo HD, Stefanovska A, Bracic M, Kirkeb\u00f8en KA, Kvernebo K (1998) Spectral analysis of the laser Doppler perfusion signal in human skin before and after exercise. Microvasc Res 56:173\u2013182","journal-title":"Microvasc Res"},{"key":"170_CR34","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1006\/mvre.1998.2108","volume":"56","author":"HD Kvernmo","year":"1998","unstructured":"Kvernmo HD, Stefanovska A, Bracic M, Kirkeboen KA, Kvernebo K (1998) Spectral analysis of the laser Doppler perfusion signal in human skin before and after exercise. Microvasc Res 56:173\u2013182","journal-title":"Microvasc Res"},{"key":"170_CR35","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1006\/mvre.1998.2139","volume":"57","author":"HD Kvernmo","year":"1999","unstructured":"Kvernmo HD, Stefanovska A, Kirkeboen KA, Kvernebo K (1999) Oscillations in the human cutaneous blood perfusion signal modified by endothelium-dependent and endothelium-independent vasodilators. Microvasc Res 57:298\u2013309","journal-title":"Microvasc Res"},{"key":"170_CR36","doi-asserted-by":"publisher","first-page":"478","DOI":"10.1097\/00000542-200609000-00010","volume":"105","author":"A Landsverk","year":"2006","unstructured":"Landsverk A, Kvandal P, Kjelstrup T, Benko U, Bernjak A, Stefanovska A, Kvernmo H, Kirkeboen KA (2006) Human skin microcirculation after brachial plexus block evaluated by wavelet transform of the laser Doppler flowmetry signal. Aesthesiology 105:478\u2013484","journal-title":"Aesthesiology"},{"key":"170_CR37","doi-asserted-by":"publisher","first-page":"14024","DOI":"10.1117\/1.2166378","volume":"11","author":"M Larsson","year":"2006","unstructured":"Larsson M, Str\u00f6mberg T (2006) Toward a velocity-resolved microvascular blood flow measure by decomposition of the laser Doppler spectrum. J Biomed Opt 11:14024\u20131-9","journal-title":"J Biomed Opt"},{"key":"170_CR38","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1117\/1.1463049","volume":"7","author":"M Larsson","year":"2002","unstructured":"Larsson M, Steenbergen W, Str\u00f6mberg T (2002) Influence of optical properties and fibre separation on laser Doppler flowmetry. J Biomed Opt 7:236\u2013243","journal-title":"J Biomed Opt"},{"key":"170_CR39","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1007\/BF02345265","volume":"39","author":"IV Meglinsky","year":"2001","unstructured":"Meglinsky IV, Matcher SJ (2001) Modelling the sampling volume for skin blood oxygenation measurements. Med Biol Eng Comput 39:44\u201350","journal-title":"Med Biol Eng Comput"},{"key":"170_CR40","unstructured":"Moor Instruments Ltd (2001) Reference list, http:\/\/www.moor.co.uk Moor Instruments Ltd"},{"key":"170_CR41","doi-asserted-by":"publisher","first-page":"2970","DOI":"10.1364\/AO.23.002970","volume":"23","author":"FFM de Mul","year":"1984","unstructured":"de Mul FFM, van Spijker J, van der Plas D, Greve J, Aarnoudse JG, Smits TM (1984) Mini laser-Doppler (blood) flow monitor with diode laser source and detection integrated in the probe. Appl Opt 23:2970\u20132973","journal-title":"Appl Opt"},{"key":"170_CR42","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1007\/BF02442104","volume":"22","author":"GE Nilsson","year":"1984","unstructured":"Nilsson GE (1984) Signal processor for Laser Doppler Tissue Flowmeters. Med Biol Eng Comput 22:343\u2013348","journal-title":"Med Biol Eng Comput"},{"key":"170_CR43","unstructured":"Nilsson H (2002) Photon migration in tissue. Laser induced fluorescence for cancer diagnostics and influence of optical properties on microvascular Doppler spectroscopy. PhD Thesis, Faculty of health sciences, Link\u00f6pings Universitet"},{"key":"170_CR44","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1109\/TBME.1980.326686","volume":"27","author":"GE Nilsson","year":"1980","unstructured":"Nilsson GE, Tenland T, \u00d6berg P\u00c5 (1980) A new instrument for continuous measurement of tissue blood flow by light beating spectroscopy. IEEE Trans Biomed Eng BME 27:12\u201319","journal-title":"IEEE Trans Biomed Eng BME"},{"key":"170_CR45","doi-asserted-by":"publisher","first-page":"597","DOI":"10.1109\/TBME.1980.326582","volume":"27","author":"GE Nilsson","year":"1980","unstructured":"Nilsson GE, Tenland T, \u00d6berg P\u00c5 (1980) Evaluation of a laser Doppler flowmeter for measurement of tissue blood flow. IEEE Trans Biomed Eng BME 27:597\u2013604","journal-title":"IEEE Trans Biomed Eng BME"},{"key":"170_CR46","unstructured":"Nilsson GE, Jakobsson A, W\u00c5rdell K (1989) Imaging of tissue blood flow by coherent light scattering, in IEEE 11th Ann EMBS Conf., Seattle, WA"},{"key":"170_CR47","doi-asserted-by":"crossref","unstructured":"Nilsson G, Jakobsson A, W\u00c5rdell K (1991) Tissue perfusion monitoring and imaging by coherent light scattering. In: Soares ODD, Scheggi AM (eds) Bioptics: optics in biomedicine and environmental sciences, vol 1524, pp 90\u2013109","DOI":"10.1117\/12.57709"},{"key":"170_CR48","volume-title":"Biomedical photonics handbook","author":"GE Nilsson","year":"2003","unstructured":"Nilsson GE, Salerud EG, Str\u00f6mberg T, W\u00c5rdell K (2003) Laser Doppler perfusion monitoring and imaging. In: Vo-Dinh T (eds) Biomedical photonics handbook. CRC Press, Boca Raton"},{"key":"170_CR49","first-page":"125","volume":"18","author":"P\u00c5 \u00d6berg","year":"1990","unstructured":"\u00d6berg P\u00c5 (1990) Laser-Doppler flowmetry. Crit Rev Biomed Eng 18:125\u2013163","journal-title":"Crit Rev Biomed Eng"},{"key":"170_CR50","unstructured":"Perimed A (2001) Reference list, http:\/\/www.perimed.se Perimed AB"},{"key":"170_CR51","doi-asserted-by":"publisher","first-page":"750","DOI":"10.1007\/BF02513378","volume":"37","author":"A Rakotomamonjy","year":"1999","unstructured":"Rakotomamonjy A, Coast D, March\u00e9 P (1999) Wavelet-based enhancement of signal-averaged electrocardiograms for late potential detection. Med Biol Eng Comput 37:750\u2013759","journal-title":"Med Biol Eng Comput"},{"key":"170_CR52","first-page":"936","volume":"11","author":"C Riva","year":"1972","unstructured":"Riva C, Ross B, Benedek GB (1972) Laser Doppler measurements of blood flow in capillary tubes and retinal arteries. Invest Ophthalmol 11:936\u2013944","journal-title":"Invest Ophthalmol"},{"key":"170_CR53","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1007\/BF02442697","volume":"24","author":"EG Salerud","year":"1986","unstructured":"Salerud EG, Nilsson GE (1986) Integrating probe for tissue laser Doppler flowmeters. Med Biol Eng Comput 24:415\u2013419","journal-title":"Med Biol Eng Comput"},{"key":"170_CR54","doi-asserted-by":"crossref","first-page":"622","DOI":"10.1364\/JOSAA.18.000622","volume":"18","author":"A Serov","year":"2001","unstructured":"Serov A, Steenbergen W, De Mul F (2001) Prediction of the photodetector signal generated by Doppler-induced speckle fluctuations: theory and some validations. J Opt Soc Am 18:622\u2013630","journal-title":"J Opt Soc Am"},{"key":"170_CR55","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1364\/OL.27.000300","volume":"27","author":"A Serov","year":"2002","unstructured":"Serov A, Steenbergen W, de Mul F (2002) Laser Doppler perfusion imaging with a complimentary metal oxide semiconductor image sensor. Opt Lett 27:300\u2013302","journal-title":"Opt Lett"},{"key":"170_CR56","doi-asserted-by":"publisher","first-page":"3681","DOI":"10.1364\/OPEX.13.003681","volume":"13","author":"A Serov","year":"2005","unstructured":"Serov A, Steinacher B, Lasser T (2005) Full-field laser Doppler perfusion imaging and monitoring with an intelligent CMOS camera. Opt Express 13:3681\u20133689","journal-title":"Opt Express"},{"key":"170_CR57","doi-asserted-by":"crossref","DOI":"10.1007\/978-1-4757-2083-9","volume-title":"Laser-Doppler blood flowmetry","author":"AP Shepherd","year":"1990","unstructured":"Shepherd AP (1990) History of laser-Doppler blood flowmetry. In: Shepherd AP, \u00d6berg P\u00c5 (eds) Laser-Doppler blood flowmetry. Kluwer, Boston"},{"key":"170_CR58","doi-asserted-by":"crossref","unstructured":"Shepherd AP, \u00d6berg P\u00c5 (eds) (1990) Laser-Doppler blood flowmetry, Kluwer, Boston","DOI":"10.1007\/978-1-4757-2083-9"},{"key":"170_CR59","doi-asserted-by":"crossref","first-page":"H1638","DOI":"10.1152\/ajpheart.00826.2000","volume":"284","author":"T S\u00f6derstr\u00f6m","year":"2003","unstructured":"S\u00f6derstr\u00f6m T, Stefanovska A, Veber M, Svensson H (2003) Involvement of sympathetic nerve activity in skin blood flow oscillations in humans. Am J Physiol Heart Circ Physiol 284:H1638\u20131646","journal-title":"Am J Physiol Heart Circ Physiol"},{"key":"170_CR60","doi-asserted-by":"publisher","first-page":"1230","DOI":"10.1109\/10.790500","volume":"46","author":"A Stefanovska","year":"1999","unstructured":"Stefanovska A, Bracic M and Kvernmo HD (1999) Wavelet analysis of oscillations in the peripheral blood circulation measured by laser Doppler technique. IEEE Trans Biomed Eng 46:1230\u20131239","journal-title":"IEEE Trans Biomed Eng"},{"key":"170_CR61","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1038\/254056a0","volume":"254","author":"MD Stern","year":"1975","unstructured":"Stern MD (1975) In vivo evaluation of microcirculation by coherent light scattering. Nature 254:56\u201358","journal-title":"Nature"},{"key":"170_CR62","first-page":"H441","volume":"232","author":"MD Stern","year":"1977","unstructured":"Stern MD, Lappe DL, Bowen PD, Chimosky JE, Holloway GA, Keiser HR, Bowman RL (1977) Continuous measurement of tissue blood flow by laser-Doppler spectroscopy. Am J Physiol 232:H441\u2013H448","journal-title":"Am J Physiol"},{"key":"170_CR63","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1046\/j.1365-2230.1999.00428.x","volume":"24","author":"M St\u00fccker","year":"1999","unstructured":"St\u00fccker M, Horstmann I, N\u00fcchel C, R\u00f6chling A, Hoffmann K, Altmeyer P (1999) Blood flow compared in benign melanocytic naevi, malignant melanomas and basal cell carcinomas. Clin Exp Dermatol 24:107\u2013111","journal-title":"Clin Exp Dermatol"},{"key":"170_CR64","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1159\/000247490","volume":"184","author":"E Tur","year":"1992","unstructured":"Tur E, Brenner S (1992) Cutaneous blood flow measurements for the detection of malignancy in pigmented skin lesions. Dermatology 184:8\u201311","journal-title":"Dermatology"},{"key":"170_CR65","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1016\/j.diabres.2006.01.002","volume":"73","author":"V Urbancic-Rovan","year":"2006","unstructured":"Urbancic-Rovan V, Bernjak A, Stefanovska A, Azman-Juvan K, Kocijancic A (2006) Macro- and microcirculation in the lower extrmities\u2014possible relationship. Diabetes Res Clin Pract 73:166\u2013173","journal-title":"Diabetes Res Clin Pract"},{"key":"170_CR66","doi-asserted-by":"publisher","first-page":"N111","DOI":"10.1088\/0031-9155\/49\/8\/N03","volume":"49","author":"M Veber","year":"2004","unstructured":"Veber M, Bandrivskyy A, Clarkson PBM, McClintock PVE, Stefanovska A (2004) Wavelet analysis of blood flow dynamics: effect on the individual oscillatory components of iontophoresis wit pharmacologically neutral electrolytes. Phys Med Biol 49:N111-N117","journal-title":"Phys Med Biol"},{"key":"170_CR67","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1109\/10.222322","volume":"40","author":"K W\u00c5rdell","year":"1993","unstructured":"W\u00c5rdell K, Jakobsson A, Nilsson GE (1993) Laser Doppler perfusion imaging by dynamic light scattering. IEEE Trans Biomed Eng 40:309\u2013316","journal-title":"IEEE Trans Biomed Eng"},{"key":"170_CR68","doi-asserted-by":"publisher","first-page":"1823","DOI":"10.1364\/AO.44.001823","volume":"44","author":"S Yuan","year":"2005","unstructured":"Yuan S, Devor A, Boas DA, Dunn AK (2005) Determination of optimal exposure time for imaging of blood flow changes with laser speckle contrast imaging. Appl Opt 44:1823\u20131830","journal-title":"Appl Opt"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-007-0170-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11517-007-0170-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-007-0170-5","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-007-0170-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,5,18]],"date-time":"2022-05-18T02:33:08Z","timestamp":1652841188000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11517-007-0170-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,3,6]]},"references-count":68,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2007,5]]}},"alternative-id":["170"],"URL":"https:\/\/doi.org\/10.1007\/s11517-007-0170-5","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,3,6]]},"assertion":[{"value":"6 November 2006","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 December 2006","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 March 2007","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}],"article-number":"421"}}