{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,4]],"date-time":"2026-10-04T07:56:09Z","timestamp":1791100569460,"version":"4.1.0"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2007,6,1]],"date-time":"2007-06-01T00:00:00Z","timestamp":1180656000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Med Bio Eng Comput"],"published-print":{"date-parts":[[2007,8,9]]},"DOI":"10.1007\/s11517-007-0190-1","type":"journal-article","created":{"date-parts":[[2007,5,31]],"date-time":"2007-05-31T05:52:12Z","timestamp":1180590732000},"page":"695-699","source":"Crossref","is-referenced-by-count":9,"title":["Implantable stimulator featuring multiple programs, adjustable stimulation amplitude and bi-directional communication for implantation in mice"],"prefix":"10.1007","volume":"45","author":[{"given":"Michael","family":"Russold","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan C.","family":"Jarvis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2007,6,1]]},"reference":[{"key":"190_CR1","unstructured":"Analog Devices (2004) Datasheet AD53x1. Analog devices"},{"key":"190_CR2","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1016\/0141-5425(81)90071-6","volume":"3","author":"J Brown","year":"1981","unstructured":"Brown J, Salmons S (1981) Percutaneous control of an implantable muscle stimulator via an optical link. J Biomed Eng 3:206\u2013208","journal-title":"J Biomed Eng"},{"key":"190_CR3","unstructured":"Cadsoft Computer GmbH (1988\u20132006) EAGLE. CadSoft Computer GmbH"},{"issue":"1","key":"190_CR4","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1007\/BF02442177","volume":"27","author":"PE Donaldson","year":"1989","unstructured":"Donaldson PE (1989) Encapsulating microelectronic implants in one-part silicone rubbers. Med Biol Eng Comput 27(1):93\u201394","journal-title":"Med Biol Eng Comput"},{"issue":"1","key":"190_CR5","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1007\/BF02446293","volume":"29","author":"PE Donaldson","year":"1991","unstructured":"Donaldson PE (1991) Aspects of silicone rubber as an encapsulant for neurological prostheses. Part 1. Osmosis. Med Biol Eng Comput 29(1):34\u201339","journal-title":"Med Biol Eng Comput"},{"issue":"5","key":"190_CR6","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1007\/BF02510794","volume":"33","author":"PE Donaldson","year":"1995","unstructured":"Donaldson PE (1995) Aspects of silicone rubber as encapsulant for neurological prostheses. Part 3: adhesion to mixed oxides. Med Biol Eng Comput 33(5):725\u2013727","journal-title":"Med Biol Eng Comput"},{"issue":"3","key":"190_CR7","first-page":"289","volume":"33","author":"PE Donaldson","year":"1995","unstructured":"Donaldson PE, Aylett BJ (1995) Aspects of silicone rubber as encapsulant for neurological prostheses. Part 2: adhesion to binary oxides. Med Biol Eng Comput 33(3):289\u2013292","journal-title":"Med Biol Eng Comput"},{"issue":"3","key":"190_CR8","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1007\/BF02530051","volume":"35","author":"P E Donaldson","year":"1997","unstructured":"Donaldson P E (1997) Aspects of silicone rubber as encapsulant for neurological prostheses. Part 4: two-part rubbers. Med Biol Eng Comput 35(3):283\u2013286","journal-title":"Med Biol Eng Comput"},{"issue":"2","key":"190_CR9","doi-asserted-by":"crossref","first-page":"53","DOI":"10.3109\/03091909109009968","volume":"15","author":"J C Jarvis","year":"1991","unstructured":"Jarvis J C, Salmons S (1991) A family of neuromuscular stimulators with optical transcutaneous control. J Med Eng Technol 15(2):53\u201357","journal-title":"J Med Eng Technol"},{"issue":"1","key":"190_CR10","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/S1350-4533(01)00005-4","volume":"23","author":"J C Jarvis","year":"2001","unstructured":"Jarvis J C, Salmons S (2001) The application and technology of implantable neuromuscular stimulators: an introduction and overview. Med Eng Phys 23(1):3\u20137","journal-title":"Med Eng Phys"},{"issue":"3","key":"190_CR11","first-page":"210","volume":"21","author":"H Lanmuller","year":"1997","unstructured":"Lanmuller H, Bijak M, Mayr W et al (1997) Useful applications and limits of battery powered implants in functional electrical stimulations. Artif Organs 21(3):210\u2013212","journal-title":"Artif Organs"},{"issue":"2","key":"190_CR12","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1109\/TNSRE.2002.1031976","volume":"10","author":"P Mela","year":"2002","unstructured":"Mela P, Veltink PH, Huijing PA et al (2002) The optimal stimulation pattern for skeletal muscle is dependent on muscle length. IEEE Trans Neural Syst Rehabil Eng 10(2):85\u201393","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"190_CR13","unstructured":"Microchip Technology Inc (2002\u20132005) MPLAB-IDE. Microchip Technology Inc"},{"key":"190_CR14","unstructured":"Microchip Technology Inc. (2004) Datasheet PIC 12F635"},{"key":"190_CR15","unstructured":"Philips Semiconductors (2000) The I2C-bus specification, v2.1. Philips"},{"issue":"3","key":"190_CR16","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1002\/mus.10064","volume":"25","author":"A Ratkevicius","year":"2002","unstructured":"Ratkevicius A, Quistorff B (2002) Metabolic costs of force generation for constant-frequency and catchlike-inducing electrical stimulation in human tibialis anterior muscle. Muscle Nerve 25(3):419\u201326","journal-title":"Muscle Nerve"},{"key":"190_CR17","unstructured":"Renata (2001) CR1220 Datasheet, Renata"},{"issue":"2","key":"190_CR18","first-page":"13P","volume":"188","author":"S Salmons","year":"1967","unstructured":"Salmons S (1967) An implantable muscle stimulator. J Physiol 188(2):13P\u201314P","journal-title":"J Physiol"},{"issue":"1","key":"190_CR19","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/S1350-4533(01)00002-9","volume":"23","author":"S Salmons","year":"2001","unstructured":"Salmons S, Gunning GT, Taylor I et al (2001) ASIC or PIC? Implantable stimulators based on semi-custom CMOS technology or low-power microcontroller architecture. Med Eng Phys 23(1):37\u201343","journal-title":"Med Eng Phys"},{"issue":"12","key":"190_CR20","doi-asserted-by":"crossref","first-page":"1632","DOI":"10.1002\/(SICI)1097-4598(199812)21:12<1632::AID-MUS3>3.0.CO;2-W","volume":"21","author":"H Sutherland","year":"1998","unstructured":"Sutherland H, Jarvis JC, Kwende MM et al (1998) The dose-related response of rabbit fast muscle to long-term low-frequency stimulation. Muscle Nerve 21(12):1632\u20131646","journal-title":"Muscle Nerve"},{"issue":"4","key":"190_CR21","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1007\/BF02344736","volume":"43","author":"MA Thil","year":"2005","unstructured":"Thil MA, Gerard B, Jarvis JC et al (2005) Two-way communication for programming and measurement in a miniature implantable stimulator. Med Biol Eng Comput 43(4):528\u2013534","journal-title":"Med Biol Eng Comput"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-007-0190-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11517-007-0190-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-007-0190-1","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,1]],"date-time":"2019-06-01T12:06:53Z","timestamp":1559390813000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11517-007-0190-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,6,1]]},"references-count":21,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2007,8,9]]}},"alternative-id":["190"],"URL":"https:\/\/doi.org\/10.1007\/s11517-007-0190-1","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,6,1]]}}}