{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,10,15]],"date-time":"2023-10-15T13:50:14Z","timestamp":1697377814499},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2007,8,25]],"date-time":"2007-08-25T00:00:00Z","timestamp":1188000000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2007,8,25]],"date-time":"2007-08-25T00:00:00Z","timestamp":1188000000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Bio Eng Comput"],"published-print":{"date-parts":[[2007,11]]},"DOI":"10.1007\/s11517-007-0215-9","type":"journal-article","created":{"date-parts":[[2007,8,24]],"date-time":"2007-08-24T08:28:09Z","timestamp":1187944089000},"page":"1127-1135","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Durability improvement of polymer chamber of pulsatile extracorporeal life support system in terms of mechanical change"],"prefix":"10.1007","volume":"45","author":[{"given":"Hyuk","family":"Choi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seung Hoon","family":"Paik","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kwang Ho","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Byoung Goo","family":"Min","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yong Soon","family":"Won","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2007,8,25]]},"reference":[{"key":"215_CR1","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1046\/j.1525-1594.1999.06318.x","volume":"23","author":"S Akira","year":"1999","unstructured":"Akira S, Motomi S, Yukihiko O, et al (1999) Major organ function under mechanical support: comparative studies of pulsatile and nonpulsatile circulation. Artif Organs 23:280\u2013285","journal-title":"Artif Organs"},{"key":"215_CR2","volume-title":"Extracorporeal circulation","author":"JG Allen","year":"1960","unstructured":"Allen JG (1960) Extracorporeal circulation. Charles C Thomas, Springfield, IL"},{"key":"215_CR3","unstructured":"Austin JW, Harner DL, et al (1990) The heart-lung machine & related technologies of open heart surgery. Phoenix Medical Communication Medical Publishers, AZ"},{"key":"215_CR4","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1097\/00002480-200205000-00015","volume":"48","author":"KA Bramstedt","year":"2002","unstructured":"Bramstedt KA, et al (2002) Failure mode and effects analysis as an informed consent tool for investigational cardiothoracic devices. ASAIO J 48:293\u2013295","journal-title":"ASAIO J"},{"key":"215_CR5","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1016\/j.ress.2004.07.001","volume":"88","author":"AC Brombacher","year":"2005","unstructured":"Brombacher AC (2005) Reliability in strongly innovative products; a threat or a challenge? Reliability Eng Syst Saf 88:125","journal-title":"Reliability Eng Syst Saf"},{"key":"215_CR6","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1097\/01.mat.0000182472.63808.b9","volume":"51","author":"F Casas","year":"2005","unstructured":"Casas F, Reeves A, Dudzinski D, et al (2005) performance and reliability of the CPB\/ECMO initiative forward lines casualty management system. ASAIO J 51:681\u2013685","journal-title":"ASAIO J"},{"issue":"4","key":"215_CR7","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1115\/1.2891213","volume":"112","author":"GJ Cheon","year":"1990","unstructured":"Cheon GJ, et al (1990) A new type of the motor-driven blood pump for artificial heart. J Biomech Eng 112(4):473\u2013475","journal-title":"J Biomech Eng"},{"key":"215_CR8","doi-asserted-by":"crossref","DOI":"10.1201\/9781420042238","volume-title":"Medical device reliability and associated areas","author":"BS Dhillon","year":"2000","unstructured":"Dhillon BS (2000) Medical device reliability and associated areas. CRC, Boca Raton, FL"},{"issue":"4","key":"215_CR9","doi-asserted-by":"crossref","first-page":"439","DOI":"10.3109\/10731197509118635","volume":"3","author":"FM Donovan Jr","year":"1975","unstructured":"Donovan FM Jr, et al (1975) Design of a hydraulic analog of the circulatory system for evaluating artificial hearts. Biomater Med Devices Artif Organs 3(4):439\u2013449","journal-title":"Biomater Med Devices Artif Organs"},{"key":"215_CR10","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1093\/clinchem\/38.1.132","volume":"38","author":"VF Fairbanks","year":"1992","unstructured":"Fairbanks VF, et al (1992) Methods for measuring plasma hemoglobin in micromolar concentration compared. Clin Chem 38:132\u2013140","journal-title":"Clin Chem"},{"key":"215_CR11","doi-asserted-by":"publisher","first-page":"358","DOI":"10.1046\/j.1525-1594.2001.025005358.x","volume":"25","author":"C Gobel","year":"2001","unstructured":"Gobel C, Arvand A, Eilers R, et al (2001) Development of the MEDOS\/HIA DeltaStreram extracorporeal rotary blood pump. Artif Organs 25:358\u2013365","journal-title":"Artif Organs"},{"key":"215_CR12","doi-asserted-by":"crossref","first-page":"1039","DOI":"10.1161\/01.RES.79.5.1039","volume":"79","author":"M Goto","year":"1996","unstructured":"Goto M, VanBavel E, Giezeman MJMM, et al (1996) Vasodilatory effect of pulsatile pressure on coronary resistance vessels. Circ Res 79:1039\u20131045","journal-title":"Circ Res"},{"issue":"1","key":"215_CR13","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1007\/BF02345135","volume":"43","author":"P He","year":"2005","unstructured":"He P, Bai J, Xia DD (2005) Optimum control of the Hemopump as a left-ventricular assist device. Med Biol Eng Comput 43(1):136\u2013141","journal-title":"Med Biol Eng Comput"},{"key":"215_CR14","unstructured":"Hallquist JO (2006) LS-DYNA Theory Manual. Livermore Software Technology Corporation, Stuttgart, Germany"},{"key":"215_CR15","first-page":"470","volume":"34","author":"JS Jassawalla","year":"1988","unstructured":"Jassawalla JS, Daniel MA, Chen H, et al (1988) In vitro and in vivo testing of a totally implantable left ventricular assist system. ASAIO 34:470\u2013475","journal-title":"ASAIO"},{"key":"215_CR16","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1111\/j.1525-1594.1997.tb00369.x","volume":"21","author":"K Kawahito","year":"1997","unstructured":"Kawahito K, Nose Y, et al (1997) Hemolysis in different centrifugal pumps. Artif Organs 21:323\u2013326","journal-title":"Artif Organs"},{"key":"215_CR17","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/S0022-5223(19)43109-7","volume":"54","author":"T Keller","year":"1967","unstructured":"Keller T, Hawrylenko A (1967) Contribution to the in vitro testing of pumps for extracorporeal circulation. J Thorac Cardiovasc Surg 54:22\u201329","journal-title":"J Thorac Cardiovasc Surg"},{"key":"215_CR18","first-page":"173","volume":"9","author":"RA Khana","year":"2006","unstructured":"Khana RA, Siddiquia NA, Naqvia SQA, Ahmadb S (2006) Reliability analysis of TLP tethers under impulsive loading. Reliability Eng Syst Saf 9:173\u2013183","journal-title":"Reliability Eng Syst Saf"},{"key":"215_CR19","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1016\/j.ress.2004.07.010","volume":"88","author":"J-A Lia","year":"2005","unstructured":"Lia J-A, Wuc Y, Laia KK, Liub K (2005) Reliability estimation and prediction of multi-state components and coherent systems. Reliability Eng Syst Saf 88:93\u201398","journal-title":"Reliability Eng Syst Saf"},{"key":"215_CR20","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1097\/00002480-200109000-00027","volume":"47","author":"J Linneweber","year":"2001","unstructured":"Linneweber J, Chow TW, Takano T, et al (2001) Direct detection of red blood cell fragments: a new flow cytometric method to evaluate hemolysis in blood pumps. ASAIO J 47:533\u2013536","journal-title":"ASAIO J"},{"key":"215_CR21","doi-asserted-by":"publisher","first-page":"426","DOI":"10.1097\/00002480-200007000-00011","volume":"46","author":"T Maeda","year":"2000","unstructured":"Maeda T, Iwasaki A, Kawahito S, et al (2000) Preclinical evaluation of a hollow fiber silicon membrane oxygenator for extracorporeal membrane oxygenator application. ASAIO J 46:426\u2013430","journal-title":"ASAIO J"},{"issue":"5","key":"215_CR22","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1007\/BF02351032","volume":"43","author":"BJ Misgeld","year":"2005","unstructured":"Misgeld BJ, Werner J, Hexamer M (2005) Robust and self-tuning blood flow control during extracorporeal circulation in the presence of system parameter uncertainties. Med Biol Eng Comput 43(5):589\u2013598","journal-title":"Med Biol Eng Comput"},{"key":"215_CR23","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1111\/j.1525-1594.1993.tb00419.x","volume":"17","author":"MR Mueller","year":"1993","unstructured":"Mueller MR, et al (1993) In vitro hematological testing of rotary blood pumps: remarks on standardization and data interpretation. Artif Organs 17:103\u2013110","journal-title":"Artif Organs"},{"key":"215_CR24","doi-asserted-by":"publisher","first-page":"651","DOI":"10.1097\/00002480-200111000-00016","volume":"47","author":"XM Mueller","year":"2001","unstructured":"Mueller XM, Tevaearai HT, Horisberger J, et al (2001) Vacuum assisted venous drainage does not increase trauma to blood cells. ASAIO J 47:651\u2013654","journal-title":"ASAIO J"},{"key":"215_CR25","volume-title":"Practical reliability engineering","author":"PDT O\u2019Connor","year":"2002","unstructured":"O\u2019Connor PDT (2002) Practical reliability engineering, 4th edn. Wiley, West Sussex, UK","edition":"4th edn"},{"key":"215_CR26","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1046\/j.1525-1594.2000.06593.x","volume":"24","author":"Y Orime","year":"2000","unstructured":"Orime Y, Shiono M, Yagi S, et al (2000) Jostra rota flow RF-30 pump systems: new centrifugal blood pump for cardiopulmonary bypass. Artf Organs 24:437\u2013441","journal-title":"Artf Organs"},{"key":"215_CR27","doi-asserted-by":"publisher","first-page":"1852","DOI":"10.1016\/S0003-4975(98)01164-3","volume":"66","author":"GM Pantalos","year":"1998","unstructured":"Pantalos GM, Altieri F, Berson A, Borrovetz H, et al (1998) Long-term mechanical circulatory support system reliability recommendation: American Society for Artificial Internal Organs and The Society of Thoracic Surgeons: long-term mechanical circulatory support system reliability recommendation. Ann Thorac Surg 66:1852\u20131859","journal-title":"Ann Thorac Surg"},{"key":"215_CR28","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1111\/j.1525-1594.2004.29006.x","volume":"29","author":"SM Patel","year":"2005","unstructured":"Patel SM, Allaire PE, Wood HG, et al (2005) Methods of failure and reliability assessment for mechanical heart pumps. Artif Organs 29:15\u201325","journal-title":"Artif Organs"},{"issue":"5","key":"215_CR29","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1177\/039139880302600509","volume":"26","author":"YR Rho","year":"2003","unstructured":"Rho YR, Choi H, Lee JC, et al (2003) Applications of the pulsatile flow versatile ECLS: in vivo studies. Int J Artif Organs 26(5):428\u2013435","journal-title":"Int J Artif Organs"},{"key":"215_CR30","doi-asserted-by":"publisher","first-page":"450","DOI":"10.1046\/j.1525-1594.2000.06587.x","volume":"24","author":"H Shin","year":"2000","unstructured":"Shin H, Yozu R, Maehara T, et al (2000) Vacuum assisted cardiopulmonary bypass in minimally invasive cardiac surgery: its feasibility and effects on hemolysis. Artif Organs 24:450\u2013453","journal-title":"Artif Organs"},{"key":"215_CR31","doi-asserted-by":"publisher","first-page":"675","DOI":"10.1111\/j.1525-1594.1997.tb03721.x","volume":"21","author":"E Tayama","year":"1997","unstructured":"Tayama E, Nakazawa T, Takami Y, et al (1997) The hemolysis test of Gyro (C1-E3) pump in pulsatile mode. Artif Organs 21:675\u2013679","journal-title":"Artif Organs"},{"key":"215_CR32","doi-asserted-by":"publisher","first-page":"1284","DOI":"10.1111\/j.1525-1594.1997.tb00489.x","volume":"21","author":"E Tayama","year":"1997","unstructured":"Tayama E, Niimi Y, Takami Y, et al (1997) Hemolysis test of a centrifugal pump in a pulsatile mode: the effect of pulsatile rate and rpm variance. Artif Organs 21:1284\u20131287","journal-title":"Artif Organs"},{"key":"215_CR33","doi-asserted-by":"crossref","first-page":"H1098","DOI":"10.1152\/ajpheart.2000.278.4.H1098","volume":"278","author":"N Toshihide","year":"2000","unstructured":"Toshihide N, Ryuji T, Ichiro N, et al (2000) Pulsatile flow enhances endothelium-derived nitric ixcide release in the peripheral vasculature. Am J Physiol Heart Circ Physiol 278:H1098\u2013H1104","journal-title":"Am J Physiol Heart Circ Physiol"},{"key":"215_CR34","doi-asserted-by":"publisher","first-page":"546","DOI":"10.1097\/00002480-200209000-00018","volume":"48","author":"DR Wheeldon","year":"2002","unstructured":"Wheeldon DR, Laforge DH, Lee J, Jansen P (2002) Novacor left ventricular assist system long term performance: comparison of clinical experiment with demonstrated in vitro reliability. ASAIO J 48:546\u2013551","journal-title":"ASAIO J"},{"key":"215_CR35","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1097\/01.MAT.0000159385.32989.7C","volume":"51","author":"CM Zapanta","year":"2005","unstructured":"Zapanta CM, Snyder AJ, Weiss WJ, et al (2005) Durability testing of a completely implantable electric total artificial heart. ASAIO 51:214\u2013223","journal-title":"ASAIO"},{"key":"215_CR36","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1016\/j.ress.2004.08.027","volume":"89","author":"G Zuoa","year":"2005","unstructured":"Zuoa G, Kumamotoa H, Nishiharaa O, Hayamab R, Nakanob S (2005) Quantitative reliability analysis of different design alternatives for steer-by-wire system. Reliability Eng Syst Saf 89:241\u2013247","journal-title":"Reliability Eng Syst Saf"},{"key":"215_CR37","volume-title":"ECMO: extracorporeal cardiopulmonary support in critical care","author":"JB Zwischenberger","year":"1995","unstructured":"Zwischenberger JB, Bartlett RH, et al (1995) ECMO: extracorporeal cardiopulmonary support in critical care. Extracorporeal Life Support Organization, Ann Arbor, MI"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-007-0215-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11517-007-0215-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-007-0215-9","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-007-0215-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,5,15]],"date-time":"2022-05-15T22:03:40Z","timestamp":1652652220000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11517-007-0215-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,8,25]]},"references-count":37,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2007,11]]}},"alternative-id":["215"],"URL":"https:\/\/doi.org\/10.1007\/s11517-007-0215-9","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,8,25]]},"assertion":[{"value":"22 December 2006","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 June 2007","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 August 2007","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}