{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T22:15:57Z","timestamp":1792102557453,"version":"4.4.0"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2007,7,6]],"date-time":"2007-07-06T00:00:00Z","timestamp":1183680000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Med Bio Eng Comput"],"published-print":{"date-parts":[[2007,9,8]]},"DOI":"10.1007\/s11517-007-0221-y","type":"journal-article","created":{"date-parts":[[2007,7,5]],"date-time":"2007-07-05T09:54:18Z","timestamp":1183629258000},"page":"877-885","source":"Crossref","is-referenced-by-count":72,"title":["A wearable mobihealth care system supporting real-time diagnosis and alarm"],"prefix":"10.1007","volume":"45","author":[{"given":"J. W.","family":"Zheng","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Z. B.","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T. H.","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Y.","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2007,7,6]]},"reference":[{"issue":"4","key":"221_CR1","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1109\/TITB.2004.837888","volume":"8","author":"U Anliker","year":"2004","unstructured":"Anliker U, Ward JA, Lukowicz P, Troster G, Dolveck F, Baer M, Keita F, Schenker EB, Catarsi F, Coluccini L, Belardinelli A, Shklarski D, Menachem A, Hirt E, Schmid R, Vuskovic M (2004) Amon: A wearable multiparameter medical monitoring and alert system. IEEE Trans Inform Technol Biomed 8(4):415\u2013427","journal-title":"IEEE Trans Inform Technol Biomed"},{"key":"221_CR2","doi-asserted-by":"crossref","unstructured":"Ayesta U, Serrano L, Romero I (2001) Complexity measure revisited: a new algorithm for classifying cardiac arrhythmias. In: Proceedings of the 23rd annual international conference IEEE-EMBS 2:1589\u20131591","DOI":"10.1109\/IEMBS.2001.1020515"},{"key":"221_CR3","unstructured":"Body Media. http:\/\/www.bodymedia.com"},{"key":"221_CR4","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1007\/BF02446141","volume":"30","author":"I Christov","year":"1992","unstructured":"Christov I, Dotsinsky I, Daskalov I (1992) High pass filtering of ECG signals using QRS elimination. Med Biol Eng Comput 30:253\u2013256","journal-title":"Med Biol Eng Comput"},{"key":"221_CR5","doi-asserted-by":"crossref","first-page":"1282","DOI":"10.1378\/chest.128.3.1282","volume":"128","author":"CF Clarenbach","year":"2005","unstructured":"Clarenbach CF, Senn O, Brack T, Kohler M, Bloch KE (2005) Monitoring of ventilation during exercise by a portable respiratory inductive plethysmograph. Chest 128:1282\u20131290","journal-title":"Chest"},{"issue":"2","key":"221_CR6","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1088\/0967-3334\/15\/2\/009","volume":"15","author":"KP Cohen","year":"1994","unstructured":"Cohen KP, Panescu D, Booske JH, Webster JG, Tompkins WJ (1994) Design of an inductive plethysmograph for ventilation measurement. Physiol Meas 15(2):217\u2013229","journal-title":"Physiol Meas"},{"issue":"2","key":"221_CR7","first-page":"155","volume":"39","author":"I Dotsinsky","year":"2005","unstructured":"Dotsinsky I, Stoyanov T (2005) Power-line interference cancellation in ECG signals. Biomed Instrum Technol 39(2):155\u2013162","journal-title":"Biomed Instrum Technol"},{"key":"221_CR8","unstructured":"Epi- medics. http:\/\/epi-medics.insa-lyon.fr\/flash\/epimedics.html"},{"key":"221_CR9","unstructured":"EP Limited. Open source arrhythmia detection software, http:\/\/eplimited.com\/software.htm"},{"key":"221_CR10","doi-asserted-by":"crossref","unstructured":"Fensli R, Gunnarson E, Gundersen T (2005) A wearable ECG-recording system for continuous arrhythmia monitoring in a wireless tele-home-care situation. In: Proceedings of the 18th symposium on CBMS, pp. 407\u2013412","DOI":"10.1109\/CBMS.2005.22"},{"issue":"7","key":"221_CR11","doi-asserted-by":"crossref","first-page":"838","DOI":"10.1109\/10.846677","volume":"47","author":"M Lagerholm","year":"2000","unstructured":"Lagerholm M, Peterson C (2000) Clustering ECG complex using hermite function and self-organizing maps. IEEE Trans Biomed Eng 47(7):838\u2013848","journal-title":"IEEE Trans Biomed Eng"},{"key":"221_CR12","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1186\/1475-925X-4-50","volume":"4","author":"C Levkov","year":"2005","unstructured":"Levkov C, Mihov G, Ivanov R, Daskalov I, Christov I, Dotsinsky I (2005) Removal of power-line interference from the ECG: a review of the subtraction procedure. Biomed Eng Online 4:50 DOI 10.1186\/1475-925X-4-50","journal-title":"Biomed Eng Online"},{"key":"221_CR13","unstructured":"Lifeguard. http:\/\/www.lifeguard.stanford.edu"},{"key":"221_CR14","doi-asserted-by":"crossref","unstructured":"Mathie MJ, Basilakis J, Celler BG (2001) A system for monitoring posture and physical activity using accelerometers. In: Proceedings of the 23rd annual international conference IEEE-EMBS 4:3654\u20133657","DOI":"10.1109\/IEMBS.2001.1019627"},{"key":"221_CR15","doi-asserted-by":"crossref","unstructured":"Mathie MJ, Lovell NH, Coster ACF, Celler BG (2002) Determining activity using a triaxial accelerometer. In: Proceedings of the second joint conference EMBS\/BMES 3:2481\u20132482","DOI":"10.1109\/IEMBS.2002.1053385"},{"key":"221_CR16","doi-asserted-by":"crossref","unstructured":"Martin T, Jovanov E, Raskovic D (2000) Issues in wearable computing for medical monitoring applications: A case study of a wearable ecg monitoring device. In: Proceedings of the 4th IEEE international symposium on wearable computers (ISWC\u201900), pp 43\u201349","DOI":"10.1109\/ISWC.2000.888463"},{"key":"221_CR17","doi-asserted-by":"crossref","unstructured":"Paradiso R (2003) Wearable health care system for vital signs monitoring. In: Proceedings of the fourth international conference IEEE-EMBS on information technology applications in biomedicine, pp 283\u2013286","DOI":"10.1109\/ITAB.2003.1222533"},{"key":"221_CR18","doi-asserted-by":"crossref","unstructured":"Park S, Jayaraman S (2003) Enhancing the quality of life through wearable technology. IEEE Eng Med Biol Mag 22(3):41\u201348","DOI":"10.1109\/MEMB.2003.1213625"},{"key":"221_CR19","unstructured":"Polar watches. http:\/\/www.polarusa.com"},{"issue":"1","key":"221_CR20","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1109\/TITB.2004.838369","volume":"9","author":"J Rodriguez","year":"2005","unstructured":"Rodriguez J, Goni A, Illarramendi A (2005) Real-time classification of ECGs on a PDA. IEEE Trans Inform Technol Biomed 9(1):23\u201334","journal-title":"IEEE Trans Inform Technol Biomed"},{"key":"221_CR21","unstructured":"So HH, Chan KL (1997) Development of QRS detection method for real-time ambulatory cardiac monitor. In: Proceedings of the 19th annual international conference IEEE-EMBS 1:289\u2013292"},{"key":"221_CR22","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1109\/TBME.2003.808826","volume":"50","author":"EM Spinelli","year":"2003","unstructured":"Spinelli EM, Pallas-Areny R, Mayosky MA (2003) AC-coupled front-end for biopotential measurements. IEEE Trans Biomed Eng 50:391\u2013395","journal-title":"IEEE Trans Biomed Eng"},{"key":"221_CR23","unstructured":"Vitaphone. http:\/\/www.vitaphone.de"},{"key":"221_CR24","first-page":"250","volume":"59","author":"FH Wilhelm","year":"2002","unstructured":"Wilhelm FH, Handke E, Roth WT (2002) Measurement of respiratory and cardiac function by the LifeShirtTM: initial assessment of usability and reliability during ambulatory sleep monitoring. Biol Psychol 59:250\u2013251","journal-title":"Biol Psychol"},{"issue":"5","key":"221_CR25","first-page":"377","volume":"19","author":"ZB Zhang","year":"2006","unstructured":"Zhang ZB, Yu MS, Li RX, Wu TH, Wu JL (2006) Design of a wearable respiratory inductive plethysmograph and its applications (in chinese). Space Med Med Eng 19(5):377\u2013381","journal-title":"Space Med Med Eng"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-007-0221-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11517-007-0221-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-007-0221-y","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,1]],"date-time":"2019-06-01T12:06:54Z","timestamp":1559390814000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11517-007-0221-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,7,6]]},"references-count":25,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2007,9,8]]}},"alternative-id":["221"],"URL":"https:\/\/doi.org\/10.1007\/s11517-007-0221-y","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,7,6]]}}}