{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T01:31:16Z","timestamp":1780536676002,"version":"3.54.1"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2007,10,10]],"date-time":"2007-10-10T00:00:00Z","timestamp":1191974400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Med Bio Eng Comput"],"published-print":{"date-parts":[[2007,11,29]]},"DOI":"10.1007\/s11517-007-0266-y","type":"journal-article","created":{"date-parts":[[2007,10,9]],"date-time":"2007-10-09T12:24:10Z","timestamp":1191932650000},"page":"1251-1257","source":"Crossref","is-referenced-by-count":96,"title":["Electrical characteristics of conductive yarns and textile electrodes for medical applications"],"prefix":"10.1007","volume":"45","author":[{"given":"Linda","family":"Rattf\u00e4lt","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria","family":"Lind\u00e9n","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Hult","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lena","family":"Berglin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Per","family":"Ask","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2007,10,10]]},"reference":[{"key":"266_CR1","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1111\/j.1399-6576.1979.tb01440.x","volume":"23","author":"P Ask","year":"1979","unstructured":"Ask P, \u00d6berg P\u00c5, \u00d6dman S, Tenland T, Skogh M (1979) ECG electrodes, a study of electrical and mechanical long-term properties. Acta Anaesth Scand 23:189\u2013206","journal-title":"Acta Anaesth Scand"},{"key":"266_CR2","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1109\/TITB.2005.854505","volume":"9","author":"F Axisa","year":"2005","unstructured":"Axisa F, Schmitt PM, Gehin C, Delhomme G, McAdams E, Dittmar A (2005) Flexible technologies and smart clothing for citizen medicine, home healthcare, and disease prevention. IEEE Trans Inf Technol Biomed 9:325\u2013336","journal-title":"IEEE Trans Inf Technol Biomed"},{"key":"266_CR3","unstructured":"Berglin L (2006) Interactive textile structures in Department of Computer Science and Engineering, vol. Licenciate. Gothemburg: Chalmers University of Technology"},{"key":"266_CR4","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1109\/TITB.2005.854515","volume":"9","author":"A Bonfiglio","year":"2005","unstructured":"Bonfiglio A, De Rossi D, Kirstein T, Locher IR, Mameli F, Paradiso R, Vozzi G (2005) Organic field effect transistors for textile applications. IEEE Trans Inf Technol Biomed 9:319\u2013324","journal-title":"IEEE Trans Inf Technol Biomed"},{"key":"266_CR5","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1016\/j.sna.2003.10.071","volume":"114","author":"M Catrysse","year":"2004","unstructured":"Catrysse M, Puers R, Hertleer C, Van Langenhove L, van Egmond H, Matthys D (2004) Towards the integration of textile sensors in a wireless monitoring suit. Sens Actuators A Phys 114:302\u2013311","journal-title":"Sens Actuators A Phys"},{"key":"266_CR6","volume-title":"Transducers for biomedical measurements: principles and applications","author":"RSC Cobbold","year":"1974","unstructured":"Cobbold RSC (1974) Transducers for biomedical measurements: principles and applications. Wiley, New York"},{"key":"266_CR7","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1109\/TADVP.2003.817329","volume":"26","author":"D Cottet","year":"2003","unstructured":"Cottet D, Grzyb J, Kirstein T, Troster G (2003) Electrical characterization of textile transmission lines. IEEE Trans Adv Packag 26:182\u2013190","journal-title":"IEEE Trans Adv Packag"},{"key":"266_CR8","volume-title":"Electrodes and the measurement of bioelectric events","author":"LA Geddes","year":"1972","unstructured":"Geddes LA (1972) Electrodes and the measurement of bioelectric events. Wiley, New York"},{"key":"266_CR9","doi-asserted-by":"crossref","first-page":"93","DOI":"10.2340\/00015555649398","volume":"64","author":"S Grimnes","year":"1984","unstructured":"Grimnes S (1984) Pathways of ionic flow through human skin in vivo. Acta Derm Venereol 64:93\u201398","journal-title":"Acta Derm Venereol"},{"key":"266_CR10","doi-asserted-by":"crossref","first-page":"1306","DOI":"10.1161\/CIRCULATIONAHA.106.180200","volume":"115","author":"P Kligfield","year":"2007","unstructured":"Kligfield P, Gettes LS, Bailey JJ, Childers R, Deal BJ, Hancock EW, van Herpen G, Kors JA, Macfarlane P, Mirvis DM, Pahlm O, Rautaharju P, Wagner GS (2007) Recommendations for the standardization and interpretation of the electrocardiogram: part I: the electrocardiogram and its technology: a scientific statement from the american heart association electrocardiography and arrhythmias committee, council on clinical cardiology; the american college of cardiology foundation; and the heart rhythm society endorsed by the international society for computerized electrocardiology. Circulation 115:1306\u20131324","journal-title":"Circulation"},{"key":"266_CR11","unstructured":"Noury N, Dittmar A, Corroy C, Baghai R, Weber JL, Blanc D, Klefstat F, Blinovska A, Vaysse S, Comet B (2004) A smart cloth for ambulatory telemonitoring of physiological parameters and activity: the VTAMN project"},{"key":"266_CR12","unstructured":"Ottenbacher J, R\u00f6mer S, Kunze C, Grossman U, Stork W (2004) Integration of a bluetooth based ECG system into clothing. Presented at international symposiom on wearable computers"},{"key":"266_CR13","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1109\/TITB.2005.854512","volume":"9","author":"R Paradiso","year":"2005","unstructured":"Paradiso R, Loriga G, Taccini N (2005) A wearable health care system based on knitted integrated sensors. IEEE Trans Inf Technol Biomed 9:337\u2013344","journal-title":"IEEE Trans Inf Technol Biomed"},{"key":"266_CR14","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1109\/MEMB.2003.1213625","volume":"22","author":"S Park","year":"2003","unstructured":"Park S, Jayaraman S (2003) Enhancing the quality of life through wearable technology. IEEE Eng Med Biol Mag 22:41\u20138","journal-title":"IEEE Eng Med Biol Mag"},{"key":"266_CR15","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1108\/09556220510590939","volume":"17","author":"G Priniotakis","year":"2005","unstructured":"Priniotakis G, Westbroek P, Van Langenhove L, Kiekens P (2005) An experimental simulation of human body behavior during sweat production measured at textile electrodes. Int J Cloth Sci Technol 17:232\u2013241","journal-title":"Int J Cloth Sci Technol"},{"key":"266_CR16","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1109\/TITB.2005.854506","volume":"9","author":"EP Scilingo","year":"2005","unstructured":"Scilingo EP, Gemignani A, Paradiso R, Taccini N, Ghelarducci B, De Rossi D (2005) Performance evaluation of sensing fabrics for monitoring physiological and biomechanical variables. IEEE Trans Inf Technol Biomed 9:345\u2013352","journal-title":"IEEE Trans Inf Technol Biomed"},{"issue":"2","key":"266_CR17","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1166\/sl.2004.039","volume":"2","author":"M Sergio","year":"2002","unstructured":"Sergio M, Manaresi N, Tartagni M, Guerrieri R, Canegallo R (2002) A textile based capacitive pressure sensor. Sens Lett 2(2):153\u2013160","journal-title":"Sens Lett"},{"key":"266_CR18","volume-title":"Physical functions of the skin","author":"RT Treager","year":"1966","unstructured":"Treager RT (1966) Physical functions of the skin. Academic, London"},{"key":"266_CR19","doi-asserted-by":"crossref","unstructured":"Wijesiriwardana R, Mitcham K, Dias T (2004) Fiber-meshed transducers based real time wearable physiological information monitoring system. Presented at eighth international symposium on wearable computers","DOI":"10.1109\/ISWC.2004.20"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-007-0266-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11517-007-0266-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-007-0266-y","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,18]],"date-time":"2024-02-18T11:35:59Z","timestamp":1708256159000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11517-007-0266-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,10,10]]},"references-count":19,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2007,11,29]]}},"alternative-id":["266"],"URL":"https:\/\/doi.org\/10.1007\/s11517-007-0266-y","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,10,10]]}}}