{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,13]],"date-time":"2026-03-13T12:31:24Z","timestamp":1773405084505,"version":"3.50.1"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2010,11,4]],"date-time":"2010-11-04T00:00:00Z","timestamp":1288828800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2011,3]]},"DOI":"10.1007\/s11517-010-0699-6","type":"journal-article","created":{"date-parts":[[2010,11,3]],"date-time":"2010-11-03T11:56:30Z","timestamp":1288785390000},"page":"373-383","source":"Crossref","is-referenced-by-count":5,"title":["A generalized calibration procedure for in vivo transit dosimetry using siemens electronic portal imaging devices"],"prefix":"10.1007","volume":"49","author":[{"given":"Andrea","family":"Fidanzio","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Francesca","family":"Greco","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laura","family":"Gargiulo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Savino","family":"Cilla","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Domenico","family":"Sabatino","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Massimo","family":"Cappiello","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cinzia","family":"Di Felice","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elisabetta","family":"Di Castro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luigi","family":"Azario","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mariateresa","family":"Russo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luciano","family":"Pompei","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guido","family":"D\u2019Onofrio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Angelo","family":"Piermattei","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2010,11,4]]},"reference":[{"key":"699_CR1","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/S0360-3016(98)00341-1","volume":"43","author":"M Essers","year":"1999","unstructured":"Essers M, Mijnheer BJ (1999) In vivo dosimetry during external photon beam radiotherapy. Int J Radiat Oncol Biol Phys 43:245\u2013259","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"699_CR2","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1016\/j.nimb.2007.11.038","volume":"266","author":"A Fidanzio","year":"2008","unstructured":"Fidanzio A, Mameli A, Placidi E et al (2008) EPID cine acquisition mode for in vivo dosimetry in dynamic arc radiation therapy. Nucl Instrum Methods Phys Res B 266:658","journal-title":"Nucl Instrum Methods Phys Res B"},{"key":"699_CR3","unstructured":"Huyskens DP, Bogaerts R, Verstrete J, Loof M, Nystrom H, Fiorino C, Broggi S, Jornet N, Ribas M, Thwaites DI (2001) Practical guidelines for the implementation of in vivo dosimetry radiotherapy with photon beams (entrance dose). Physics for clinical radiotherapy. ESTRO Booklet n.5"},{"key":"699_CR4","unstructured":"IAEA (International Atomic Energy Agency) (2004) Absorbed dose in external beam radiotherapy: an international code of practice for dosimetry based on standards of absorbed dose to water IAEA TRS 398"},{"key":"699_CR5","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1016\/S0167-8140(98)00122-4","volume":"49","author":"M Kroonwijk","year":"1998","unstructured":"Kroonwijk M, Pasma KL, Quint S, Koper PC, Visser AG, Heijmen BJ (1998) In vivo dosimetry for prostate cancer patients using an electronic portal imaging device (EPID); demonstration of internal organ motion. Radiother Oncol 49:125\u2013132","journal-title":"Radiother Oncol"},{"key":"699_CR6","volume-title":"Radiation effects in semiconductor devices","author":"F Larin","year":"1968","unstructured":"Larin F (1968) Radiation effects in semiconductor devices. Wiley, New York"},{"key":"699_CR7","doi-asserted-by":"crossref","first-page":"2376","DOI":"10.1118\/1.1589496","volume":"30","author":"RJ Louwe","year":"2003","unstructured":"Louwe RJ, Damen EM, van Herk M, Minken AW, Torzsok O, Mijnheer BJ (2003) Three-dimensional dose reconstruction of breast cancer treatment using portal imaging. Med Phys 30:2376\u20132389","journal-title":"Med Phys"},{"key":"699_CR8","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1118\/1.1637969","volume":"31","author":"R Louwe","year":"2004","unstructured":"Louwe R, McDermott L, Sonke J, Tielenburg R, Wendling M, van Herk M, Mijnheer B (2004) The long-term stability of amorphous silicon flat panel imaging devices for dosimetry purposes. Med Phys 31:285\u2013295","journal-title":"Med Phys"},{"key":"699_CR9","doi-asserted-by":"crossref","first-page":"3921","DOI":"10.1118\/1.2230810","volume":"33","author":"LN McDermott","year":"2006","unstructured":"McDermott LN, Wendling M, van Asselen B et al (2006) Clinical experience with EPID dosimetry for prostate IMRT pretreatment dose verification. Med Phys 33:3921\u20133930","journal-title":"Med Phys"},{"key":"699_CR10","doi-asserted-by":"crossref","first-page":"2448","DOI":"10.1118\/1.2207318","volume":"33","author":"LN McDermott","year":"2006","unstructured":"McDermott LN, Nijsten SM, Sonke JJ, Partridge M, van Herk M, Mijnheer BJ (2006) Comparison of ghosting effects for three commercial a-Si EPIDs. Med Phys 33:2448\u20132451","journal-title":"Med Phys"},{"key":"699_CR11","doi-asserted-by":"crossref","first-page":"1568","DOI":"10.1016\/j.ijrobp.2006.11.047","volume":"67","author":"LN McDermott","year":"2007","unstructured":"McDermott LN, Wendling M, Sonke JJ, van Herk M, Mijnheer BJ (2007) Replacing pretreatment verification with in vivo EPIDdosimetry for prostate IMRT. Int J Radiat Oncol Biol Phys 67:1568\u20131577","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"699_CR12","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1016\/j.radonc.2007.11.010","volume":"86","author":"LN McDermott","year":"2008","unstructured":"McDermott LN, Wendling M, Nijkamp J et al (2008) 3D in vivo dose verification of entire hypo-fractionated IMRT treatments using an EPID and cone-beam CT. Radiother Oncol 86:35\u201342","journal-title":"Radiother Oncol"},{"key":"699_CR13","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1093\/rpd\/ncn231","volume":"131","author":"B Mijnheer","year":"2008","unstructured":"Mijnheer B (2008) State of the art of in vivo dosimetry. Radiat Prot Dosimetry 131:117\u2013122","journal-title":"Radiat Prot Dosimetry"},{"key":"699_CR14","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/j.radonc.2007.03.003","volume":"83","author":"S Nijsten","year":"2007","unstructured":"Nijsten S, Mijnheer B, Dekker A, Lambin P, Minken A (2007) Routine individualised patient dosimetry using electronic portal imaging devices. Radiother Oncol 83:65\u201375","journal-title":"Radiother Oncol"},{"key":"699_CR15","doi-asserted-by":"crossref","first-page":"3872","DOI":"10.1118\/1.2776244","volume":"34","author":"SM Nijsten","year":"2007","unstructured":"Nijsten SM, van Elmpt WJ, Jacobs M et al (2007) A global calibration model for a-Si EPIDs used for transit dosimetry. Med Phys 34:3872\u20133884","journal-title":"Med Phys"},{"key":"699_CR16","doi-asserted-by":"crossref","first-page":"1847","DOI":"10.1118\/1.1494988","volume":"29","author":"M Partridge","year":"2002","unstructured":"Partridge M, Ebert M, Hesse BM (2002) IMRT verification by threedimensional dose reconstruction from portal beam measurements. Med Phys 29:1847\u20131858","journal-title":"Med Phys"},{"key":"699_CR17","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1016\/S0168-9002(01)02023-X","volume":"484","author":"M Partridge","year":"2002","unstructured":"Partridge M, Hesse B, Muller L (2002) A performance comparison of direct and indirect detection flat-panel imagers. Nucl Instrum Methods Phys Res A 484:351\u2013363","journal-title":"Nucl Instrum Methods Phys Res A"},{"key":"699_CR18","doi-asserted-by":"crossref","first-page":"830","DOI":"10.1118\/1.598293","volume":"25","author":"KL Pasma","year":"1998","unstructured":"Pasma KL, Heijmen BJ, Kroonwijk M, Visser AG (1998) Portal dose image (PDI) prediction for dosimetric treatment verification in radiotherapy. I. An algorithm for open beams. Med Phys 25:830\u2013840","journal-title":"Med Phys"},{"key":"699_CR19","doi-asserted-by":"crossref","first-page":"1297","DOI":"10.1016\/S0360-3016(99)00328-4","volume":"45","author":"KL Pasma","year":"1999","unstructured":"Pasma KL, Kroonwijk M, Quint S, Visser AG, Heijmen BJM (1999) Transit dosimetry with an electronic portal imaging device (EPID) for 115 prostate cancer patients. Int J Radiat Oncol Biol Phys 45:1297\u20131303","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"699_CR20","doi-asserted-by":"crossref","first-page":"925","DOI":"10.1118\/1.1463064","volume":"29","author":"KL Pasma","year":"2002","unstructured":"Pasma KL, Vieira SC, Heijmen BJ (2002) Portal dose image prediction for dosimetric treatment verification in radiotherapy. II. An algorithm for wedged beams. Med Phys 29:925\u2013931","journal-title":"Med Phys"},{"key":"699_CR21","doi-asserted-by":"crossref","first-page":"4414","DOI":"10.1118\/1.2360014","volume":"33","author":"A Piermattei","year":"2006","unstructured":"Piermattei A, Fidanzio A, Stimato G, Azario L, Grimaldi L, D\u2019Onofrio G, Cilla S (2006) In vivo dosimetry by an aSi-based EPID. Med Phys 33:4414\u20134422","journal-title":"Med Phys"},{"key":"699_CR22","doi-asserted-by":"crossref","first-page":"5101","DOI":"10.1088\/0031-9155\/52\/16\/026","volume":"52","author":"A Piermattei","year":"2007","unstructured":"Piermattei A, Fidanzio A, Azario L et al (2007) Application of a practical method for the isocenter point in vivo dosimetry by a transit signal. Phys Med Biol 52:5101\u20135117","journal-title":"Phys Med Biol"},{"key":"699_CR23","doi-asserted-by":"crossref","first-page":"1414","DOI":"10.1080\/02841860802304572","volume":"47","author":"A Piermattei","year":"2008","unstructured":"Piermattei A, Cilla S, Grimaldi L, Viola P, Frattarolo L, D\u2019Onofrio G et al (2008) Real time dosimetry reconstruction for the breath hold radiotherapy technique: an initial experience. Acta Oncol 47:1414\u20131421","journal-title":"Acta Oncol"},{"issue":"4","key":"699_CR24","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1007\/s11517-009-0456-x","volume":"47","author":"A Piermattei","year":"2009","unstructured":"Piermattei A, Fidanzio A, Azario L, Greco F, Mameli A, Cilla S, Grimaldi L, D\u2019Onofrio G, Augelli BG, Stimato G, Gaudino D, Ramella S, D\u2019Angelillo R, Cellini F, Trodella L (2009) In patient dose reconstruction using a cine acquisition for dynamic arc radiation therapy. Med Biol Eng Comput 47(4):425\u2013433","journal-title":"Med Biol Eng Comput"},{"issue":"6","key":"699_CR25","doi-asserted-by":"crossref","first-page":"2206","DOI":"10.1118\/1.3129158","volume":"36","author":"A Piermattei","year":"2009","unstructured":"Piermattei A, Cilla S, Grimaldi L, Sabatino D et al (2009) Integration between in vivo dosimetry and image guided radiotherapy for lung tumors. Med Phys 36(6):2206\u20132214","journal-title":"Med Phys"},{"issue":"1","key":"699_CR26","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1007\/s11517-009-0558-5","volume":"48","author":"A Piermattei","year":"2010","unstructured":"Piermattei A, Fidanzio A, Cilla S, Greco F, Azario L, Sabatino D, Grusio M, Cozzolino M, Fusco V (2010) Dose-guided radiotherapy for lung tumors. Med Biol Eng Comput 48(1):79\u201386","journal-title":"Med Biol Eng Comput"},{"key":"699_CR27","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1088\/0031-9155\/41\/1\/009","volume":"41","author":"U Schneider","year":"1996","unstructured":"Schneider U, Pedroni E, Lomax A (1996) The calibration of CT Hounsfield units for radiotherapy treatment planning Phys. Med Biol 41:111\u2013124","journal-title":"Med Biol"},{"key":"699_CR28","doi-asserted-by":"crossref","first-page":"1624","DOI":"10.1118\/1.598657","volume":"26","author":"J Siewerdsen","year":"1999","unstructured":"Siewerdsen J, Jaffray D (1999) A ghost story: spatio-temporal response characteristics of an indirect-detection flat-panel imager. Med Phys 26:1624\u20131641","journal-title":"Med Phys"},{"key":"699_CR29","unstructured":"SSI (2000) The Swedish Radiation Protection Institute\u2019s regulations on radiation therapy. SSTFS Swedish Radiation Protection Authority 4"},{"key":"699_CR30","volume-title":"Ver. 4. Systat","author":"TableCurve 3D","year":"2004","unstructured":"TableCurve 3D (2004) Ver. 4. Systat. Software, Inc, CA, USA"},{"key":"699_CR31","doi-asserted-by":"crossref","first-page":"4367","DOI":"10.1118\/1.2357834","volume":"33","author":"C Talamonti","year":"2006","unstructured":"Talamonti C, Casati M, Bucciolini M (2006) Pretreatment verification of IMRT absolute dose distributions using a commercial a-Si EPID. Med Phys 33:4367\u20134378","journal-title":"Med Phys"},{"key":"699_CR32","doi-asserted-by":"crossref","first-page":"2805","DOI":"10.1118\/1.1987988","volume":"32","author":"WJ Elmpt van","year":"2005","unstructured":"van Elmpt WJ, Nijsten SM, Mijnheer BJ, Minken AW (2005) Experimental verification of a portal dose prediction model. Med Phys 32:2805\u20132818","journal-title":"Med Phys"},{"key":"699_CR33","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1016\/j.radonc.2008.07.008","volume":"88","author":"W Elmpt van","year":"2008","unstructured":"van Elmpt W, McDermott L, Nijsten S, Wendling M, Lambin P, Mijnheer B (2008) A literature review of electronic portal imaging for radiotherapy dosimetry. Radiother Oncol 88:289\u2013309","journal-title":"Radiother Oncol"},{"key":"699_CR34","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1016\/S0167-8140(01)00305-X","volume":"60","author":"A Esch Van","year":"2001","unstructured":"Van Esch A, Vanstraelen B, Verstraete J, Kutcher G, Huyskens D (2001) Pretreatment dosimetric verification by means of a liquid-filled electronic portal imaging device during dynamic delivery of intensity modulated treatment fields. Radiother Oncol 60:181\u2013190","journal-title":"Radiother Oncol"},{"key":"699_CR35","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1016\/j.radonc.2004.02.018","volume":"71","author":"A Esch Van","year":"2004","unstructured":"Van Esch A, Depuydt T, Huyskens DP (2004) The use of an aSi-based EPID for routine absolute dosimetric pre-treatment verification of dynamic IMRT fields. Radiother Oncol 71:223\u2013234","journal-title":"Radiother Oncol"},{"key":"699_CR36","doi-asserted-by":"crossref","first-page":"2369","DOI":"10.1088\/0031-9155\/42\/12\/005","volume":"42","author":"JLM Venselaar","year":"1997","unstructured":"Venselaar JLM, Heukelom S, Jager HN, Mijnheer BJ, van Gasteren JJ, van Kleffens HJ, van der Laarse R, Westermann CF (1997) Is there a need for a revised table of equivalent square fields for the determination of phantom scatter correction factors? Phys Med Biol 42:2369\u20132381","journal-title":"Phys Med Biol"},{"key":"699_CR37","doi-asserted-by":"crossref","first-page":"3095","DOI":"10.1118\/1.2040711","volume":"32","author":"P Winkler","year":"2005","unstructured":"Winkler P, Hefner A, Georg D (2005) Dose\u2013response characteristics of an amorphous silicon EPID. Med Phys 32:3095\u20133105","journal-title":"Med Phys"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-010-0699-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11517-010-0699-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-010-0699-6","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,1]],"date-time":"2019-06-01T16:09:50Z","timestamp":1559405390000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11517-010-0699-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,11,4]]},"references-count":37,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2011,3]]}},"alternative-id":["699"],"URL":"https:\/\/doi.org\/10.1007\/s11517-010-0699-6","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,11,4]]}}}