{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,9,29]],"date-time":"2023-09-29T23:26:26Z","timestamp":1696029986829},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2012,3,6]],"date-time":"2012-03-06T00:00:00Z","timestamp":1330992000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2012,4]]},"DOI":"10.1007\/s11517-012-0889-5","type":"journal-article","created":{"date-parts":[[2012,3,6]],"date-time":"2012-03-06T01:02:05Z","timestamp":1330995725000},"page":"403-410","source":"Crossref","is-referenced-by-count":4,"title":["Safety of multi-channel stimulation implants: a single blocking capacitor per channel is not sufficient after single-fault failure"],"prefix":"10.1007","volume":"50","author":[{"given":"Antoine","family":"Nonclercq","sequence":"first","affiliation":[]},{"given":"Laurent","family":"Lonys","sequence":"additional","affiliation":[]},{"given":"Anne","family":"Vanhoestenberghe","sequence":"additional","affiliation":[]},{"given":"Andreas","family":"Demosthenous","sequence":"additional","affiliation":[]},{"given":"Nick","family":"Donaldson","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2012,3,6]]},"reference":[{"issue":"1","key":"889_CR1","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/0306-4522(93)90180-N","volume":"52","author":"WF Agnew","year":"1993","unstructured":"Agnew WF, McCreery DB, Yuen TG, Bullara LA (1993) MK-801 protects against neuronal injury induced by electrical stimulation. Neuroscience 52(1):45\u201353","journal-title":"Neuroscience"},{"issue":"6","key":"889_CR2","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1038\/sc.1982.65","volume":"20","author":"GS Brindley","year":"1982","unstructured":"Brindley GS, Polkey CE, Rushton DN (1982) Sacral anterior root stimulators for bladder control in paraplegia. Paraplegia 20(6):365\u2013381","journal-title":"Paraplegia"},{"issue":"1","key":"889_CR3","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/0302-4598(75)80002-X","volume":"2","author":"S Brummer","year":"1975","unstructured":"Brummer S, Turner M (1975) Electrical stimulation of the nervous system: the principle of safe charge injection with noble metal electrodes. Bioeletrochem Bioenerg 2(1):13\u201325","journal-title":"Bioeletrochem Bioenerg"},{"issue":"12","key":"889_CR4","doi-asserted-by":"crossref","first-page":"2261","DOI":"10.1109\/TBME.2007.908310","volume":"54","author":"A Butterwick","year":"2007","unstructured":"Butterwick A, Vankov A, Huie P, Freyvert Y, Palanker D (2007) Tissue damage by pulsed electrical stimulation. IEEE Trans Biomed Eng 54(12):2261\u20132267","journal-title":"IEEE Trans Biomed Eng"},{"issue":"1","key":"889_CR5","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1007\/BF02441605","volume":"24","author":"N Donaldson","year":"1986","unstructured":"Donaldson N, Donaldson PEK (1986) When are actively balanced biphasic (\u2018Lilly\u2019) stimulating pulses necessary in a neurological prosthesis? II pH changes; noxious products; electrode corrosion; discussion. Med Biol Eng Comput 24(1):50\u201356","journal-title":"Med Biol Eng Comput"},{"key":"889_CR6","unstructured":"European Standard (1998) EN45502-1 for safety, marking and information to be provided by the manufacturer in Active Implantable Medical Devices. CENELEC, Brussels, p 8"},{"issue":"7","key":"889_CR7","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1007\/s11517-007-0209-7","volume":"45","author":"O Gilad","year":"2007","unstructured":"Gilad O, Horesh L, Holder DS (2007) Design of electrodes and current limits for low frequency electrical impedance tomography of the brain. Med Biol Eng Comput 45(7):621\u2013633","journal-title":"Med Biol Eng Comput"},{"issue":"4","key":"889_CR8","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1007\/s11517-011-0756-9","volume":"49","author":"GR Hern\u00e1ndez-Labrado","year":"2011","unstructured":"Hern\u00e1ndez-Labrado GR, Polo JL, L\u00f3pez-Dolado E, Collazos-Castro JE (2011) Spinal cord direct current stimulation: finite element analysis of the electric field and current density. Med Biol Eng Comput 49(4):417\u2013429","journal-title":"Med Biol Eng Comput"},{"issue":"4","key":"889_CR9","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1109\/10.752943","volume":"46","author":"CQ Huang","year":"1999","unstructured":"Huang CQ, Shepherd RK, Carter PM, Seligman PM, Tabor B (1999) Electrical stimulation of the auditory nerve: direct current measurement in vivo. IEEE Trans Biomed Eng 46(4):461\u2013470","journal-title":"IEEE Trans Biomed Eng"},{"issue":"6","key":"889_CR10","doi-asserted-by":"crossref","first-page":"905","DOI":"10.3171\/jns.1993.79.6.0905","volume":"79","author":"RJ Hurlbert","year":"1993","unstructured":"Hurlbert RJ, Tator CH, Theriault E (1993) Dose-response study of the pathological effects of chronically applied direct current stimulation on the normal rat spinal cord. J Neurosurg 79(6):905\u2013916","journal-title":"J Neurosurg"},{"issue":"1","key":"889_CR11","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.medengphy.2010.08.010","volume":"33","author":"MJ Kane","year":"2011","unstructured":"Kane MJ, Breen PP, Quondamatteo F, \u00d3Laighin G (2011) BION microstimulators: a case study in the engineering of an electronic implantable medical device. Med Eng Phys 33(1):7\u201316","journal-title":"Med Eng Phys"},{"issue":"1","key":"889_CR12","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1109\/TBCAS.2009.2034138","volume":"4","author":"PJ Langlois","year":"2010","unstructured":"Langlois PJ, Demosthenous A, Pachnis I, Donaldson N (2010) High-power integrated stimulator output stages with floating discharge over a wide voltage range for nerve stimulation. IEEE Trans Biomed Circuits Syst 4(1):39\u201348","journal-title":"IEEE Trans Biomed Circuits Syst"},{"issue":"3","key":"889_CR13","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1109\/TBCAS.2008.2003199","volume":"2","author":"X Liu","year":"2008","unstructured":"Liu X, Demosthenous A, Donaldson N (2008) An integrated implantable stimulator that is fail-safe without off-chip blocking-capacitors. IEEE Trans Biomed Circuits Syst 2(3):231\u2013244","journal-title":"IEEE Trans Biomed Circuits Syst"},{"issue":"1","key":"889_CR14","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/S1350-4533(01)00011-X","volume":"23","author":"GE Loeb","year":"2001","unstructured":"Loeb GE, Peck RA, Moore WH, Hood K (2001) BION system for distributed neural prosthetic interfaces. Med Eng Phys 23(1):9\u201318","journal-title":"Med Eng Phys"},{"issue":"2","key":"889_CR15","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1016\/j.jneumeth.2004.10.020","volume":"141","author":"DR Merrill","year":"2005","unstructured":"Merrill DR, Bikson M, Jefferys JGR (2005) Electrical stimulation of excitable tissue: design of efficacious and safe protocols. J Neurosci Methods 141(2):171\u2013198","journal-title":"J Neurosci Methods"},{"issue":"12","key":"889_CR16","doi-asserted-by":"crossref","first-page":"2946","DOI":"10.1109\/JSSC.2007.908693","volume":"42","author":"M Ortmanns","year":"2007","unstructured":"Ortmanns M, Rocke A, Gehrke M, Tiedtke H-J (2007) A 232-channel epiretinal stimulator ASIC. IEEE J Solid-State Circuits 42(12):2946\u20132959","journal-title":"IEEE J Solid-State Circuits"},{"issue":"2","key":"889_CR17","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1016\/j.jneumeth.2008.03.016","volume":"171","author":"M Schuettler","year":"2008","unstructured":"Schuettler M, Franke M, Krueger TB, Stieglitz T (2008) A voltage-controlled current source with regulated electrode bias-voltage for safe neural stimulation. J Neurosci Methods 171(2):248\u2013252","journal-title":"J Neurosci Methods"},{"issue":"6","key":"889_CR18","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1080\/00016489950180621","volume":"119","author":"RK Shepherd","year":"1999","unstructured":"Shepherd RK, Linahan N, Xu J, Clark GM, Araki S (1999) Chronic electrical stimulation of the auditory nerve using non-charge-balanced stimuli. Acta Otolaryngol 119(6):674\u2013684","journal-title":"Acta Otolaryngol"},{"key":"889_CR19","unstructured":"Tripolar book electrodes, Finetech Medical Ltd, 13 Tewin Court, Welwyn Garden City, Hertfordshire, AL7 1AU, United Kingdom"},{"key":"889_CR20","unstructured":"Vanhoestenberghe A (2007) Implanted devices: improved methods for nerve root stimulation. PhD Thesis, University College London, London, United Kingdom"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-012-0889-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11517-012-0889-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-012-0889-5","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,1]],"date-time":"2019-06-01T16:10:03Z","timestamp":1559405403000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11517-012-0889-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,3,6]]},"references-count":20,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2012,4]]}},"alternative-id":["889"],"URL":"https:\/\/doi.org\/10.1007\/s11517-012-0889-5","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,3,6]]}}}