{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,26]],"date-time":"2025-10-26T22:50:46Z","timestamp":1761519046535},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2012,6,22]],"date-time":"2012-06-22T00:00:00Z","timestamp":1340323200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2012,10]]},"DOI":"10.1007\/s11517-012-0932-6","type":"journal-article","created":{"date-parts":[[2012,8,6]],"date-time":"2012-08-06T17:49:04Z","timestamp":1344275344000},"page":"1047-1057","source":"Crossref","is-referenced-by-count":26,"title":["Non-invasive continuous glucose monitoring: improved accuracy of point and trend estimates of the Multisensor system"],"prefix":"10.1007","volume":"50","author":[{"given":"Mattia","family":"Zanon","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giovanni","family":"Sparacino","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrea","family":"Facchinetti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michela","family":"Riz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark S.","family":"Talary","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roland E.","family":"Suri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andreas","family":"Caduff","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Claudio","family":"Cobelli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2012,6,22]]},"reference":[{"key":"932_CR1","doi-asserted-by":"crossref","first-page":"1191","DOI":"10.1007\/s11517-010-0665-3","volume":"48","author":"A Abu-Rmileh","year":"2010","unstructured":"Abu-Rmileh A, Garcia-Gabin W, Zambrano D (2010) A robust sliding mode controller with internal model for closed-loop artificial pancreas. Med Biol Eng Comput 48:1191\u20131201","journal-title":"Med Biol Eng Comput"},{"key":"932_CR2","doi-asserted-by":"crossref","first-page":"5429","DOI":"10.1021\/ac050429e","volume":"77","author":"MA Arnold","year":"2005","unstructured":"Arnold MA, Small GW (2005) Noninvasive glucose sensing. Anal Chem 77:5429\u20135439","journal-title":"Anal Chem"},{"key":"932_CR3","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1089\/dia.2005.7.28","volume":"7","author":"BW Bequette","year":"2005","unstructured":"Bequette BW (2005) A critical assessment of algorithms and challenges in the development of a closed-loop artificial pancreas. Diabetes Technol Ther 7:28\u201347","journal-title":"Diabetes Technol Ther"},{"key":"932_CR4","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1111\/j.1742-1241.2009.02272.x","volume":"166","author":"BW Bode","year":"2010","unstructured":"Bode BW, Battelino T (2010) Continuous glucose monitoring. Int J Clin Pract Suppl 166:11\u201315","journal-title":"Int J Clin Pract Suppl"},{"key":"932_CR5","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1007\/s11517-011-0760-0","volume":"49","author":"R Burattini","year":"2011","unstructured":"Burattini R, Morettini M, Di Nardo F, Boemi M (2011) Dynamics of insulin action in hypertension: assessment from minimal model interpretation of intravenous glucose tolerance test data. Med Biol Eng Comput 49:831\u2013841","journal-title":"Med Biol Eng Comput"},{"key":"932_CR6","doi-asserted-by":"crossref","first-page":"598","DOI":"10.1016\/j.bios.2006.01.031","volume":"22","author":"A Caduff","year":"2006","unstructured":"Caduff A, Dewarrat F, Talary M, Stalder G, Heinemann L, Feldman Y (2006) Non-invasive glucose monitoring in patients with diabetes: a novel system based on impedance spectroscopy. Biosens Bioelectron 22:598\u2013604","journal-title":"Biosens Bioelectron"},{"key":"932_CR7","doi-asserted-by":"crossref","first-page":"2778","DOI":"10.1016\/j.bios.2009.02.001","volume":"24","author":"A Caduff","year":"2009","unstructured":"Caduff A, Talary MS, Mueller M, Dewarrat F, Klisic J, Donath M, Heinemann L, Stahel WA (2009) Non-invasive glucose monitoring in patients with type 1 diabetes: a multisensor system combining sensors for dielectric and optical characterisation of skin. Biosens Bioelectron 24:2778\u20132784","journal-title":"Biosens Bioelectron"},{"key":"932_CR8","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1089\/dia.2009.0095","volume":"12","author":"A Caduff","year":"2010","unstructured":"Caduff A, Talary MS, Zakharov P (2010) Cutaneous blood perfusion as a perturbing factor for noninvasive glucose monitoring. Diabetes Technol Ther 12:1\u20139","journal-title":"Diabetes Technol Ther"},{"key":"932_CR9","doi-asserted-by":"crossref","first-page":"3794","DOI":"10.1016\/j.bios.2011.02.034","volume":"26","author":"A Caduff","year":"2011","unstructured":"Caduff A, Mueller M, Megej A, Dewarrat F, Suri RE, Klisic J, Donath M, Zakharov P, Schaub D, Stahel WA, Talary MS (2011) Characteristics of a multisensor system for non invasive glucose monitoring with external validation and prospective evaluation. Biosens Bioelectron 26:3794\u20133800","journal-title":"Biosens Bioelectron"},{"key":"932_CR10","doi-asserted-by":"crossref","first-page":"622","DOI":"10.2337\/diacare.10.5.622","volume":"10","author":"WL Clarke","year":"1987","unstructured":"Clarke WL, Cox D, Gonder-Frederick LA, Carter W, Pohl SL (1987) Evaluating clinical accuracy of systems for self-blood glucose monitoring systems. Diabetes Care 10:622\u2013628","journal-title":"Diabetes Care"},{"key":"932_CR11","doi-asserted-by":"crossref","first-page":"E1","DOI":"10.1152\/ajpendo.00421.2006","volume":"293","author":"C Cobelli","year":"2007","unstructured":"Cobelli C, Toffolo GM, Dalla Man C, Campioni M, Denti P, Caumo A, Butler P, Rizza R (2007) Assessment of beta-cell function in humans, simultaneously with insulin sensitivity and hepatic extraction, from intravenous and oral glucose tests. Am J Physiol Endocrinol Metab 293:E1\u2013E15","journal-title":"Am J Physiol Endocrinol Metab"},{"key":"932_CR12","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1109\/RBME.2009.2036073","volume":"2","author":"C Cobelli","year":"2009","unstructured":"Cobelli C, Dalla Man C, Sparacino G, Magni L, De Nicolao G, Kovatchev BP (2009) Diabetes: models, signals, and control. IEEE Rev Biomed Eng 2:54\u201396","journal-title":"IEEE Rev Biomed Eng"},{"key":"932_CR13","doi-asserted-by":"crossref","first-page":"2672","DOI":"10.2337\/db11-0654","volume":"60","author":"C Cobelli","year":"2011","unstructured":"Cobelli C, Renard E, Kovatchev B (2011) Artificial pancreas: past, present, future. Diabetes 60:2672\u20132682","journal-title":"Diabetes"},{"key":"932_CR14","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/0169-7439(93)85002-X","volume":"18","author":"S Jong De","year":"1993","unstructured":"De Jong S (1993) SIMPLS: an alternative approach to partial least squares regression. Chemom Intell Lab Syst 18:251\u2013263","journal-title":"Chemom Intell Lab Syst"},{"key":"932_CR15","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1214\/009053604000000067","volume":"32","author":"B Efron","year":"2004","unstructured":"Efron B, Hastie T, Johnstone I, Tibshirani R (2004) Least angle regression. Ann Stat 32:407\u2013451","journal-title":"Ann Stat"},{"key":"932_CR16","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1007\/s11517-005-0012-2","volume":"44","author":"PG Fabietti","year":"2006","unstructured":"Fabietti PG, Canonico V, Federici MO, Benedetti MM, Sarti E (2006) Control oriented model of insulin and glucose dynamics in type 1 diabetics. Med Biol Eng Comput 44:69\u201378","journal-title":"Med Biol Eng Comput"},{"key":"932_CR17","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1007\/s11517-010-0717-8","volume":"49","author":"F Galvanin","year":"2011","unstructured":"Galvanin F, Barolo M, Macchietto S, Bezzo F (2011) Optimal design of clinical tests for the identification of physiological models of type 1 diabetes in the presence of model mismatch. Med Biol Eng Comput 49:263\u2013277","journal-title":"Med Biol Eng Comput"},{"key":"932_CR18","doi-asserted-by":"crossref","unstructured":"Guerra S, Facchinetti A, Sparacino G, De Nicolao G, Cobelli C (2012) Enhancing the accuracy of subcutaneous glucose sensors: a real-time deconvolution-based approach. IEEE Trans Biomed Eng (Epub ahead of print)","DOI":"10.1109\/TBME.2012.2191782"},{"key":"932_CR19","unstructured":"Guerra S, Facchinetti A, Sparacino G, De Nicolao G, Cobelli C Method to recalibrate continuous glucose monitoring data on-line. International patent application, International Bureau of the World Intellectual Property Organization, Geneva. Official Filing number: PCT\/IB2010\/054947"},{"key":"932_CR20","doi-asserted-by":"crossref","first-page":"843","DOI":"10.1089\/dia.2011.0006","volume":"13","author":"S Guerra","year":"2011","unstructured":"Guerra S, Sparacino G, Facchinetti A, Schiavon M, Dalla Man C, Cobelli C (2011) A dynamic risk measure from continuous glucose monitoring data. Diabetes Technol Ther 13:843\u2013852","journal-title":"Diabetes Technol Ther"},{"key":"932_CR21","unstructured":"Hastie TJ, Tibshirani R, Friedman JH (2009) The elements of statistical learning: data mining, inference, and prediction, 2nd edn. Springer, New York, pp 43\u201394, 219\u2013257"},{"key":"932_CR22","doi-asserted-by":"crossref","first-page":"269","DOI":"10.2174\/157339908785294479","volume":"4","author":"R Hovorka","year":"2008","unstructured":"Hovorka R (2008) The future of continuous glucose monitoring: closed loop. Curr Diabetes Rev 4:269\u2013279","journal-title":"Curr Diabetes Rev"},{"key":"932_CR23","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.2337\/diacare.20.11.1655","volume":"20","author":"BP Kovatchev","year":"1997","unstructured":"Kovatchev BP, Cox DJ, Gonder-Frederick LA, Clarke W (1997) Symmetrization of the blood glucose measurement scale and its applications. Diabetes Care 20:1655\u20131658","journal-title":"Diabetes Care"},{"key":"932_CR24","doi-asserted-by":"crossref","first-page":"1922","DOI":"10.2337\/diacare.27.8.1922","volume":"27","author":"BP Kovatchev","year":"2004","unstructured":"Kovatchev BP, Gonder-Frederick LA, Cox DJ, Clarke WL (2004) Evaluating the accuracy of continuous glucose-monitoring sensors. Diabetes Care 27:1922\u20131928","journal-title":"Diabetes Care"},{"key":"932_CR25","doi-asserted-by":"crossref","first-page":"1160","DOI":"10.2337\/dc07-2401","volume":"31","author":"B Kovatchev","year":"2008","unstructured":"Kovatchev B, Anderson S, Heinemann L, Clarke W (2008) Comparison of the numerical and clinical accuracy of four continuous glucose monitors. Diabetes Care 31:1160\u20131164","journal-title":"Diabetes Care"},{"key":"932_CR26","doi-asserted-by":"crossref","first-page":"2263","DOI":"10.2337\/diacare.25.12.2263","volume":"25","author":"KV Larin","year":"2002","unstructured":"Larin KV, Eledrisi MS, Motamedi M, Esenaliev RO (2002) Noninvasive blood glucose monitoring with optical coherence tomography: a pilot study in human subjects. Diabetes Care 25:2263\u20132267","journal-title":"Diabetes Care"},{"key":"932_CR27","doi-asserted-by":"crossref","first-page":"338","DOI":"10.1016\/j.bspc.2009.04.003","volume":"4","author":"L Magni","year":"2009","unstructured":"Magni L, Raimondo DM, Dalla Man C, De Nicolao G, Kovatchev B, Cobelli C (2009) Model predictive control of glucose concentration in type I diabetic patients: an in silico trial. Biomed Signal Process 4:338\u2013346","journal-title":"Biomed Signal Process"},{"key":"932_CR28","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1089\/dia.2008.0047","volume":"11","author":"G McGarraugh","year":"2009","unstructured":"McGarraugh G (2009) The chemistry of commercial continuous glucose monitors. Diabetes Technol Ther 11:17\u201324","journal-title":"Diabetes Technol Ther"},{"key":"932_CR29","doi-asserted-by":"crossref","first-page":"694","DOI":"10.1177\/193229681100500324","volume":"5","author":"M Mueller","year":"2011","unstructured":"Mueller M, De Feo O, Talary MS, Stahel WA, Falco L, Caduff A (2011) Data processing for non-invasive continuous glucose monitoring with a multi-Sensor device. J Diabetes Sci Technol 5:694\u2013702","journal-title":"J Diabetes Sci Technol"},{"key":"932_CR30","doi-asserted-by":"crossref","first-page":"931","DOI":"10.1109\/TBME.2006.889774","volume":"54","author":"G Sparacino","year":"2007","unstructured":"Sparacino G, Zanderigo F, Corazza S, Maran A, Facchinetti A, Cobelli C (2007) Glucose concentration can be predicted ahead in time from continuous glucose monitoring sensor time-series. IEEE Trans Biomed Eng 54:931\u2013937","journal-title":"IEEE Trans Biomed Eng"},{"key":"932_CR31","doi-asserted-by":"crossref","first-page":"6751","DOI":"10.3390\/s100706751","volume":"10","author":"G Sparacino","year":"2010","unstructured":"Sparacino G, Facchinetti A, Cobelli C (2010) \u201cSmart\u201d continuous glucose monitoring sensors: on-line signal processing issues. Sensors 10:6751\u20136772","journal-title":"Sensors"},{"key":"932_CR32","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1111\/j.2517-6161.1996.tb02080.x","volume":"58","author":"R Tibshirani","year":"1994","unstructured":"Tibshirani R (1994) Regression shrinkage and selection via the lasso. J R Stat Soc Ser B 58:267\u2013288","journal-title":"J R Stat Soc Ser B"},{"key":"932_CR33","volume-title":"Solutions of ill-posed problems","author":"AN Tikhonov","year":"1977","unstructured":"Tikhonov AN, Arsenin VY (1977) Solutions of ill-posed problems. Winston\/Wiley, Washington, DC"},{"key":"932_CR34","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1016\/j.diabres.2006.10.027","volume":"77","author":"A Tura","year":"2007","unstructured":"Tura A, Maran A, Pacini G (2007) Non-invasive glucose monitoring: assessment of technologies and devices according to quantitative criteria. Diabetes Res Clin Pract 77:16\u201340","journal-title":"Diabetes Res Clin Pract"},{"key":"932_CR35","doi-asserted-by":"crossref","first-page":"986","DOI":"10.1038\/214986a0","volume":"214","author":"SJ Updike","year":"1967","unstructured":"Updike SJ, Hicks GP (1967) The enzyme electrode. Nature 214:986\u2013988","journal-title":"Nature"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-012-0932-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11517-012-0932-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-012-0932-6","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,4,28]],"date-time":"2024-04-28T06:22:02Z","timestamp":1714285322000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11517-012-0932-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,6,22]]},"references-count":35,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2012,10]]}},"alternative-id":["932"],"URL":"https:\/\/doi.org\/10.1007\/s11517-012-0932-6","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,6,22]]}}}