{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,19]],"date-time":"2025-12-19T15:22:13Z","timestamp":1766157733812},"reference-count":43,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2014,6,20]],"date-time":"2014-06-20T00:00:00Z","timestamp":1403222400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2014,8]]},"DOI":"10.1007\/s11517-014-1169-3","type":"journal-article","created":{"date-parts":[[2014,6,19]],"date-time":"2014-06-19T15:11:19Z","timestamp":1403190679000},"page":"639-651","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":26,"title":["A wireless power transmission system for implantable devices in freely moving rodents"],"prefix":"10.1007","volume":"52","author":[{"given":"Kyungsik","family":"Eom","sequence":"first","affiliation":[]},{"given":"Joonsoo","family":"Jeong","sequence":"additional","affiliation":[]},{"given":"Tae Hyung","family":"Lee","sequence":"additional","affiliation":[]},{"given":"Jinhyung","family":"Kim","sequence":"additional","affiliation":[]},{"given":"Junghoon","family":"Kim","sequence":"additional","affiliation":[]},{"given":"Sung Eun","family":"Lee","sequence":"additional","affiliation":[]},{"given":"Sung June","family":"Kim","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2014,6,20]]},"reference":[{"key":"1169_CR1","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1109\/4.654942","volume":"33","author":"T Akin","year":"1998","unstructured":"Akin T, Najafi K, Bradley RM (1998) A wireless implantable multichannel digital neural recording system for a micromachined sieve electrode. IEEE J Solid-State Circuits 33:109\u2013118","journal-title":"IEEE J Solid-State Circuits"},{"key":"1169_CR2","doi-asserted-by":"crossref","first-page":"026010","DOI":"10.1088\/1741-2560\/10\/2\/026010","volume":"10","author":"DA Borton","year":"2013","unstructured":"Borton DA, Yin M, Aceros J, Nurmikko A (2013) An implantable wireless neural interface for recording cortical circuit dynamics in moving primates. J Neural Eng 10:026010","journal-title":"J Neural Eng"},{"key":"1169_CR3","doi-asserted-by":"crossref","first-page":"1230","DOI":"10.1109\/TMTT.1984.1132833","volume":"32","author":"WC Brown","year":"1984","unstructured":"Brown WC (1984) The history of power transmission by radio waves. IEEE Trans Microw Theory Tech 32:1230\u20131242","journal-title":"IEEE Trans Microw Theory Tech"},{"key":"1169_CR4","doi-asserted-by":"crossref","first-page":"1819","DOI":"10.1109\/TPEL.2009.2017195","volume":"24","author":"BL Cannon","year":"2009","unstructured":"Cannon BL, Hoburg JF, Stancil DD, Goldstein SC (2009) Magnetic resonant coupling as a potential means for wireless power transfer to multiple small receivers. IEEE Trans Power Electron 24:1819\u20131825","journal-title":"IEEE Trans Power Electron"},{"key":"1169_CR5","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1016\/j.bios.2009.08.049","volume":"25","author":"R Carta","year":"2009","unstructured":"Carta R, Tortora G, Thon\u00e9 J, Lenaerts B, Valdastri P, Menciassi A, Dario P, Puers R (2009) Wireless powering for a self-propelled and steerable endoscopic capsule for stomach inspection. Biosens Bioelectron 25:845\u2013851","journal-title":"Biosens Bioelectron"},{"key":"1169_CR6","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/j.sna.2009.12.025","volume":"162","author":"R Carta","year":"2010","unstructured":"Carta R, Thon\u00e9 J, Puers R (2010) A wireless power supply system for robotic capsular endoscopes. Sensor Actuat A-phys 162:177\u2013183","journal-title":"Sensor Actuators A-Phys"},{"key":"1169_CR7","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1016\/j.sna.2004.02.016","volume":"115","author":"M Catrysse","year":"2004","unstructured":"Catrysse M, Hermans B, Puers R (2004) An inductive power system with integrated bi-directional data-transmission. Sensor Actuat A-phys 115:221\u2013229","journal-title":"Sensor Actuators A-Phys"},{"key":"1169_CR8","doi-asserted-by":"crossref","first-page":"1238","DOI":"10.1109\/41.969404","volume":"48","author":"K Chang-Gyun","year":"2001","unstructured":"Chang-Gyun K, Dong-Hyun S, Jung-Sik Y, Jong-Hu P, Cho BH (2001) Design of a contactless battery charger for cellular phone. IEEE Trans Ind Electron 48:1238\u20131247","journal-title":"IEEE Trans Ind Electron"},{"key":"1169_CR9","doi-asserted-by":"crossref","first-page":"3631","DOI":"10.1109\/JSSC.2009.2035551","volume":"44","author":"P Cong","year":"2009","unstructured":"Cong P, Chaimanonart N, Ko WH, Young DJ (2009) A wireless and batteryless 10-bit implantable blood pressure sensing microsystem with adaptive RF powering for real-time laboratory mice monitoring. IEEE J Solid-State Circuits 44:3631\u20133644","journal-title":"IEEE J Solid-State Circuits"},{"key":"1169_CR10","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1109\/JSEN.2009.2030982","volume":"10","author":"P Cong","year":"2010","unstructured":"Cong P, Ko WH, Young DJ (2010) Wireless batteryless implantable blood pressure monitoring microsystem for small laboratory animals. IEEE Sens J 10:243\u2013254","journal-title":"IEEE Sensors J"},{"key":"1169_CR11","doi-asserted-by":"crossref","first-page":"2109","DOI":"10.1109\/TCSI.2005.852923","volume":"52","author":"W Guoxing","year":"2005","unstructured":"Guoxing W, Wentai L, Sivaprakasam M, Kendir GA (2005) Design and analysis of an adaptive transcutaneous power telemetry for biomedical implants. IEEE Trans Circuits Syst I Regul Pap 52:2109\u20132117","journal-title":"IEEE Trans Circuits Syst I Regul Papers"},{"key":"1169_CR12","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1109\/10.1388","volume":"35","author":"WJ Heetderks","year":"1988","unstructured":"Heetderks WJ (1988) Rf powering of millimeter- and submillimeter-sized neural prosthetic implants. IEEE Trans Biomed Eng 35:323\u2013327","journal-title":"IEEE Trans Biomed Eng"},{"key":"1169_CR13","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1109\/TBME.1984.325404","volume":"31","author":"ES Hochmair","year":"1984","unstructured":"Hochmair ES (1984) System optimization for improved accuracy in transcutaneous signal and power transmission. IEEE Trans Biomed Eng 31:177\u2013186","journal-title":"IEEE Trans Biomed Eng"},{"key":"1169_CR14","doi-asserted-by":"crossref","first-page":"4746","DOI":"10.1109\/TIE.2011.2112317","volume":"58","author":"T Imura","year":"2011","unstructured":"Imura T, Hori Y (2011) Maximizing air gap and efficiency of magnetic resonant coupling for wireless power transfer using equivalent circuit and Neumann formula. IEEE Trans Ind Electron 58:4746\u20134752","journal-title":"IEEE Trans Ind Electron"},{"key":"1169_CR15","doi-asserted-by":"crossref","unstructured":"Jeong J, Lee SW, Min KS, Kim SJ (2012) A novel multilayered planar coil based on biocompatible liquid crystal polymer for chronic implantation. Sensor Actuat A-phys 197:38\u201346","DOI":"10.1016\/j.sna.2013.04.001"},{"key":"1169_CR16","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1109\/TBCAS.2012.2211872","volume":"6","author":"U-M Jow","year":"2012","unstructured":"Jow U-M, Kiani M, Huo X, Ghovanloo M (2012) Towards a smart experimental arena for long-term electrophysiology experiments. IEEE Trans Biomed Circuits Syst 6:414\u2013423","journal-title":"IEEE Trans Biomed Circuits Syst"},{"key":"1169_CR17","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/j.aop.2007.04.017","volume":"323","author":"A Karalis","year":"2008","unstructured":"Karalis A, Joannopoulos JD, Soljacic M (2008) Efficient wireless non-radiative mid-range energy transfer. Ann Phys 323:34\u201348","journal-title":"Ann Phys"},{"key":"1169_CR18","first-page":"179","volume-title":"Rf power amplifier","author":"K Marian","year":"2008","unstructured":"Kazimierczuk MK (2008) Rf power amplifier, 1st edn. Wiley, London, pp 179\u2013238","edition":"1"},{"key":"1169_CR19","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1109\/TCSI.2005.846208","volume":"52","author":"GA Kendir","year":"2005","unstructured":"Kendir GA, Wentai L, Guoxing W, Sivaprakasam M, Bashirullah R, Humayun MS, Weiland JD (2005) An optimal design methodology for inductive power link with class-e amplifier. IEEE Trans Biomed Circuits Syst 52:857\u2013866","journal-title":"IEEE Trans Biomed Circuits Syst"},{"key":"1169_CR20","doi-asserted-by":"crossref","first-page":"997","DOI":"10.1002\/jnr.23222","volume":"91","author":"J Kim","year":"2013","unstructured":"Kim J, Eun Lee S, Sik Min K, Jung HH, Lee JE, Kim SJ, Chang JW (2013) Ventral posterolateral deep brain stimulation treatment for neuropathic pain shortens pain response after cold stimuli. J Neurosci Res 91:997\u20131004","journal-title":"J Neurosci Res"},{"key":"1169_CR21","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1001\/archotol.130.5.499","volume":"130","author":"EA Kretzmer","year":"2004","unstructured":"Kretzmer EA, Meltzer NE, Haenggeli C, Ryugo DK (2004) An animal model for cochlear implants. Arch Otolaryngol\u00a0Head Neck Surg 130:499\u2013508","journal-title":"Arch Otolaryngol-Head Neck Surg"},{"key":"1169_CR22","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1126\/science.1143254","volume":"317","author":"A Kurs","year":"2007","unstructured":"Kurs A, Karalis A, Moffatt R, Joannopoulos JD, Fisher P, Soljacic M (2007) Wireless power transfer via strongly coupled magnetic resonances. Science 317:83\u201386","journal-title":"Science"},{"key":"1169_CR23","doi-asserted-by":"crossref","first-page":"2085","DOI":"10.1109\/TBME.2012.2196274","volume":"59","author":"SE Lee","year":"2012","unstructured":"Lee SE, Jun SB, Lee HJ, Kim J, Lee SW, Im C, Shin HC, Chang JW, Kim SJ (2012) A flexible depth probe using liquid crystal polymer. IEEE Trans Biomed Eng 59:2085\u20132094","journal-title":"IEEE Trans Biomed Eng"},{"key":"1169_CR24","doi-asserted-by":"crossref","first-page":"2255","DOI":"10.1109\/TBME.2011.2136341","volume":"58","author":"SW Lee","year":"2011","unstructured":"Lee SW, Min KS, Jeong J, Kim J, Kim SJ (2011) Monolithic encapsulation of implantable neuroprosthetic devices using liquid crystal polymers. IEEE Trans Biomed Eng 58:2255\u20132263","journal-title":"IEEE Trans Biomed Eng"},{"key":"1169_CR25","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1111\/j.1525-1403.2010.00296.x","volume":"13","author":"TH Lee","year":"2010","unstructured":"Lee TH, Pan H, Kim IS, Kim JK, Cho TH, Oh JH, Yoon YB, Lee JH, Hwang SJ, Kim SJ (2010) Functional regeneration of a severed peripheral nerve with a 7-mm gap in rats through the use of an implantable electrical stimulator and a conduit electrode with collagen coating. Neuromodulation 13:299\u2013304","journal-title":"Neuromodulation"},{"key":"1169_CR26","doi-asserted-by":"crossref","first-page":"522","DOI":"10.1016\/j.sna.2005.01.033","volume":"123\u2013124","author":"B Lenaerts","year":"2005","unstructured":"Lenaerts B, Puers R (2005) Inductive powering of a freely moving system. Sensor Actuat\u00a0A-phys 123\u2013124:522\u2013530","journal-title":"Sensor Actuators A-Phys"},{"key":"1169_CR27","doi-asserted-by":"crossref","first-page":"1390","DOI":"10.1016\/j.bios.2006.06.015","volume":"22","author":"B Lenaerts","year":"2007","unstructured":"Lenaerts B, Puers R (2007) An inductive power link for a wireless endoscope. Biosens Bioelectron 22:1390\u20131395","journal-title":"Biosens Bioelectron"},{"key":"1169_CR28","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1007\/s004110000049","volume":"39","author":"C Marino","year":"2000","unstructured":"Marino C, Cristalli G, Galloni P, Pasqualetti P, Piscitelli M, Lovisolo GA (2000) Effects of microwaves (900 mhz) on the cochlear receptor: exposure systems and preliminary results. Radiat Environ Biophys 39:131\u2013136","journal-title":"Radiat Environ Biophys"},{"key":"1169_CR29","doi-asserted-by":"crossref","first-page":"1710","DOI":"10.1109\/LAWP.2013.2239600","volume":"11","author":"K Mori","year":"2012","unstructured":"Mori K, Lim H, Iguchi S, Ishida K, Takamiya M, Sakurai T (2012) Positioning-free resonant wireless power transmission sheet with staggered repeater coil array (srca). IEEE Antennas Wirel Propag Lett 11:1710\u20131713","journal-title":"IEEE Antennas Wirel Propag Lett"},{"key":"1169_CR30","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1007\/978-3-211-35205-2_13","volume":"99","author":"SI Park","year":"2006","unstructured":"Park SI, Oh JH, Hwang YS, Kim SJ, Chang JW (2006) Electrical stimulation of the anterior cingulate cortex in a rat neuropathic pain model. Acta Neurochir Suppl 99:65\u201371","journal-title":"Acta Neurochir Suppl"},{"key":"1169_CR31","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1146\/annurev.neuro.29.051605.112824","volume":"29","author":"JS Perlmutter","year":"2006","unstructured":"Perlmutter JS, Mink JW (2006) Deep brain stimulation. Annu Rev Neurosci 29:229\u2013257","journal-title":"Annu Rev Neurosci"},{"key":"1169_CR32","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1109\/TBCAS.2010.2072782","volume":"5","author":"AK RamRakhyani","year":"2011","unstructured":"RamRakhyani AK, Mirabbasi S, Mu C (2011) Design and optimization of resonance-based efficient wireless power delivery systems for biomedical implants. IEEE Trans Biomed Circuits Syst 5:48\u201363","journal-title":"IEEE Trans Biomed Circuits Syst"},{"key":"1169_CR33","unstructured":"RamRakhyani AK, Lazzi G (2012) On the design of efficient multi-coil telemetry system for biomedical implants. IEEE Trans Biomed Circuits Syst 7:11\u201323"},{"key":"1169_CR34","doi-asserted-by":"crossref","first-page":"2608","DOI":"10.1109\/TIM.2008.925019","volume":"57","author":"AP Sample","year":"2008","unstructured":"Sample AP, Yeager DJ, Powledge PS, Mamishev AV, Smith JR (2008) Design of an RFID-based battery-free programmable sensing platform. IEEE Trans Instrum Meas 57:2608\u20132615","journal-title":"IEEE Trans Instrum Meas"},{"key":"1169_CR35","doi-asserted-by":"crossref","first-page":"544","DOI":"10.1109\/TIE.2010.2046002","volume":"58","author":"AP Sample","year":"2011","unstructured":"Sample AP, Meyer DA, Smith JR (2011) Analysis, experimental results, and range adaptation of magnetically coupled resonators for wireless power transfer. IEEE Trans Ind Electron 58:544\u2013554","journal-title":"IEEE Trans Ind Electron"},{"key":"1169_CR36","doi-asserted-by":"crossref","first-page":"8620","DOI":"10.1523\/JNEUROSCI.20-22-08620.2000","volume":"20","author":"TE Scammell","year":"2000","unstructured":"Scammell TE, Estabrooke IV, McCarthy MT, Chemelli RM, Yanagisawa M, Miller MS, Saper CB (2000) Hypothalamic arousal regions are activated during modafinil-induced wakefulness. J Neurosci 20:8620\u20138628","journal-title":"J Neurosci"},{"key":"1169_CR37","first-page":"41","volume-title":"Inductive powering. Basic theory and application to biomedical systems","author":"KV Schuylenbergh","year":"2009","unstructured":"Schuylenbergh KV, Puers R (2009) Inductive powering. Basic theory and application to biomedical systems, 1st edn. Springer, Heidelberg, pp 41\u201376","edition":"1"},{"key":"1169_CR38","doi-asserted-by":"crossref","first-page":"3110","DOI":"10.1109\/TAP.2009.2028498","volume":"57","author":"V Singh","year":"2009","unstructured":"Singh V, Qusba A, Roy A, Castro RA, McClure K, Dai R, Greenberg RJ, Weiland JD, Humayun MS, Lazzi G (2009) Specific absorption rate and current densities in the human eye and head induced by the telemetry link of an epiretinal prosthesis. IEEE Trans Antennas Propag 57:3110\u20133118","journal-title":"IEEE Trans Antennas Propag"},{"key":"1169_CR39","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1109\/TBCAS.2012.2222881","volume":"6","author":"SJ Thomas","year":"2012","unstructured":"Thomas SJ, Harrison RR, Leonardo A, Reynolds MS (2012) A battery-free multichannel digital neural\/emg telemetry system for flying insects. IEEE Trans Biomed Circuits Syst 6:424\u2013436","journal-title":"IEEE Trans Biomed Circuits Syst"},{"key":"1169_CR40","doi-asserted-by":"crossref","first-page":"925","DOI":"10.1163\/156939309788355180","volume":"23","author":"XC Wei","year":"2009","unstructured":"Wei XC, Li EP, Guan YL, Chong YH (2009) Simulation and experimental comparison of different coupling mechanisms for the wireless electricity transfer. J Electromagn Waves Appl 23:925\u2013934","journal-title":"J Electromagn Waves Appl"},{"key":"1169_CR41","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1038\/352236a0","volume":"352","author":"BS Wilson","year":"1991","unstructured":"Wilson BS, Finley CC, Lawson DT, Wolford RD, Eddington DK, Rabinowitz WM (1991) Better speech recognition with cochlear implants. Nature 352:236\u2013238","journal-title":"Nature"},{"key":"1169_CR42","doi-asserted-by":"crossref","first-page":"716","DOI":"10.1109\/10.55682","volume":"37","author":"CM Zierhofer","year":"1990","unstructured":"Zierhofer CM, Hochmair ES (1990) High-efficiency coupling-insensitive transcutaneous power and data transmission via an inductive link. IEEE Trans Biomed Eng 37:716\u2013722","journal-title":"IEEE Trans Biomed Eng"},{"key":"1169_CR43","doi-asserted-by":"crossref","first-page":"1022","DOI":"10.1126\/science.1067996","volume":"295","author":"E Zrenner","year":"2002","unstructured":"Zrenner E (2002) Will retinal implants restore vision? Science 295:1022\u20131025","journal-title":"Science"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-014-1169-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11517-014-1169-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-014-1169-3","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,8,11]],"date-time":"2019-08-11T18:44:33Z","timestamp":1565549073000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11517-014-1169-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,6,20]]},"references-count":43,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2014,8]]}},"alternative-id":["1169"],"URL":"https:\/\/doi.org\/10.1007\/s11517-014-1169-3","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,6,20]]}}}