{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T13:16:11Z","timestamp":1740143771128,"version":"3.37.3"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2016,3,25]],"date-time":"2016-03-25T00:00:00Z","timestamp":1458864000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"name":"Axa research foundation"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2016,8]]},"DOI":"10.1007\/s11517-016-1463-3","type":"journal-article","created":{"date-parts":[[2016,3,25]],"date-time":"2016-03-25T08:50:58Z","timestamp":1458895858000},"page":"1257-1267","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A phantom axon setup for validating models of action potential recordings"],"prefix":"10.1007","volume":"54","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9367-8835","authenticated-orcid":false,"given":"Olivier","family":"Rossel","sequence":"first","affiliation":[]},{"given":"Fabien","family":"Soulier","sequence":"additional","affiliation":[]},{"given":"Serge","family":"Bernard","sequence":"additional","affiliation":[]},{"given":"David","family":"Guiraud","sequence":"additional","affiliation":[]},{"given":"Guy","family":"Cath\u00e9bras","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2016,3,25]]},"reference":[{"key":"1463_CR1","doi-asserted-by":"crossref","unstructured":"Andreasen LNS, Struijk JJ, Haugland MK (1997) An artificial nerve fiber for evaluation of nerve cuff electrodes. In: Proceedings of the 19th annual international conference of the IEEE engineering in medicine and biology society, 1997, vol 5, pp 1997\u20131999","DOI":"10.1109\/IEMBS.1997.758734"},{"key":"1463_CR2","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1007\/BF02345015","volume":"38","author":"LNS Andreasen","year":"2000","unstructured":"Andreasen LNS, Struijk JJ, Lawrence SM (2000) Measurement of the performance of nerve cuff electrodes for recording. Med Biol Eng Comput 38:447\u2013453","journal-title":"Med Biol Eng Comput"},{"key":"1463_CR3","doi-asserted-by":"crossref","first-page":"1045","DOI":"10.1109\/TBME.2002.800785","volume":"49","author":"LNS Andreasen","year":"2002","unstructured":"Andreasen LNS, Struijk JJ (2002) Signal strength versus cuff length in nerve cuff electrode recordings. IEEE Trans Biomed Eng 49:1045\u20131050","journal-title":"IEEE Trans Biomed Eng"},{"key":"1463_CR4","doi-asserted-by":"crossref","first-page":"056005","DOI":"10.1088\/1741-2560\/8\/5\/056005","volume":"8","author":"W Brian","year":"2011","unstructured":"Brian W, Durand DM (2011) Selective recovery of fascicular activity in peripheral nerves. J Neural Eng 8:056005","journal-title":"J Neural Eng"},{"key":"1463_CR5","doi-asserted-by":"crossref","first-page":"1063","DOI":"10.1109\/TBME.2003.816075","volume":"50","author":"E Cavallaro","year":"2003","unstructured":"Cavallaro E, Micera S, Dario P, Jensen W, Sinkjaer T (2003) On the intersubject generalization ability in extracting kinematic information from afferent nervous signals. IEEE Trans Biomed Eng 50:1063\u20131073","journal-title":"IEEE Trans Biomed Eng"},{"key":"1463_CR6","first-page":"126","volume-title":"Medical instrumentation, application and design ch. 4. Wileyfourth ed","author":"JW Clark","year":"2009","unstructured":"Clark JW (2009) The origin of biopotentials. In: Webster JG (ed) Medical instrumentation, application and design ch. 4. Wileyfourth ed. Wiley, New York, pp 126\u2013188"},{"key":"1463_CR7","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1016\/S0006-3495(68)86524-5","volume":"8","author":"J Clark","year":"1968","unstructured":"Clark J, Plonsey R (1968) The extracellular potential field of the single active nerve fiber in a volume conductor. Biophys J 8:842\u2013864","journal-title":"Biophys J"},{"key":"1463_CR8","doi-asserted-by":"crossref","first-page":"1034","DOI":"10.1152\/jn.01018.2009","volume":"104","author":"CJ Luca De","year":"2010","unstructured":"De Luca CJ, Hostage EC (2010) Relationship between firing rate and recruitment threshold of motoneurons in voluntary isometric contractions. J Neurophysiol 104:1034\u20131046","journal-title":"J Neurophysiol"},{"key":"1463_CR9","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1109\/TNSRE.2005.856072","volume":"13","author":"GS Dhillon","year":"2005","unstructured":"Dhillon GS, Horch KW (2005) Direct neural sensory feedback and control of a prosthetic arm. IEEE Trans Neural Syst Rehabil Eng 13:468\u2013472","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"1463_CR10","first-page":"445","volume":"17","author":"M Djilas","year":"2009","unstructured":"Djilas M, Azevedo Coste C, Guiraud D, Yoshida K (2009) Interpretation of muscle spindle afferent nerve response to passive muscle stretch recorded with thin-film longitudinal intrafascicular electrodes. IEEE TNSRE 17:445\u2013453","journal-title":"IEEE TNSRE"},{"key":"1463_CR11","first-page":"9:1","volume":"2010","author":"M Djilas","year":"2010","unstructured":"Djilas M, Azevedo-Coste C, Guiraud D, Yoshida K (2010) Spike sorting of muscle spindle afferent nerve activity recorded with thin-film intrafascicular electrodes. Intell Neurosci 2010:9:1\u20139:10","journal-title":"Intell Neurosci"},{"key":"1463_CR12","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1016\/S0006-3495(87)83269-1","volume":"52","author":"N Ganapathy","year":"1987","unstructured":"Ganapathy N, Clark JW (1987) Extracellular currents and potentials of the active myelinated nerve fiber. Biophys J 52:749\u2013761","journal-title":"Biophys J"},{"key":"1463_CR13","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1007\/BF02344216","volume":"40","author":"E Huigen","year":"2002","unstructured":"Huigen E, Peper A, Grimbergen CA (2002) Investigation into the origin of the noise of surface electrodes. Med Biol Eng Comput 40:332\u2013338","journal-title":"Med Biol Eng Comput"},{"key":"1463_CR14","doi-asserted-by":"crossref","first-page":"997","DOI":"10.1007\/s11517-008-0386-z","volume":"46","author":"X Liu","year":"2008","unstructured":"Liu X, Demosthenous A, Donaldson N (2008) Platinum electrode noise in the ENG spectrum. Med Biol Eng Comput 46:997\u20131003","journal-title":"Med Biol Eng Comput"},{"key":"1463_CR15","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1007\/BF02442964","volume":"15","author":"GE Loeb","year":"1977","unstructured":"Loeb GE, Marks WB, Beatty PG (1977) Electrode arrays intended for chronic, multiple single-unit recording from captured nerve fibres. Med Biol Eng Comput 15:195\u2013201","journal-title":"Med Biol Eng Comput"},{"key":"1463_CR16","doi-asserted-by":"crossref","first-page":"995","DOI":"10.1152\/jn.00353.2001","volume":"87","author":"CC McIntyre","year":"2002","unstructured":"McIntyre CC, Richardson AG, Grill WM (2002) Modeling the excitability of mammalian nerve fibers: influence of afterpotentials on the recovery cycle. J Neurophysiol 87:995\u20131006","journal-title":"J Neurophysiol"},{"key":"1463_CR17","doi-asserted-by":"crossref","first-page":"1146","DOI":"10.1109\/10.709558","volume":"45","author":"JH Meier","year":"1998","unstructured":"Meier JH, Rutten WLC, Boom HBK (1998) Extracellular potentials from active myelinated fibers inside insulated and noninsulated peripheral nerve. IEEE Trans Biomed Eng 45:1146\u20131153","journal-title":"IEEE Trans Biomed Eng"},{"key":"1463_CR18","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1111\/j.1085-9489.2005.10303.x","volume":"10","author":"X Navarro","year":"2005","unstructured":"Navarro X, Krueger TB, Lago N, Micera S, Stieglitz Thomas, Dario Paolo (2005) A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems. J Peripher Nerv Syst 10:229\u2013258","journal-title":"J Peripher Nerv Syst"},{"key":"1463_CR19","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1109\/TNSRE.2013.2278479","volume":"22","author":"TN Nielsen","year":"2014","unstructured":"Nielsen TN, Sevcencu C, Struijk JJ (2014) Comparison of mono-, bi-, and tripolar configurations for stimulation and recording with an interfascicular interface. IEEE Trans Neural Syst Rehabil Eng 22:88\u201395","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"1463_CR20","doi-asserted-by":"crossref","first-page":"1024","DOI":"10.1109\/10.247801","volume":"40","author":"DB Popovic","year":"1993","unstructured":"Popovic DB, Stein RB, Jovanovic KL, Dai R, Kostov A, Armstrong WW (1993) Sensory nerve recording for closed-loop control to restore motor functions. IEEE Trans Biomed Eng 40:1024\u20131031","journal-title":"IEEE Trans Biomed Eng"},{"key":"1463_CR21","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1007\/s11517-012-0930-8","volume":"50","author":"S Qiao","year":"2012","unstructured":"Qiao S, Odoemene O, Yoshida K (2012) Determination of electrode to nerve fiber distance and nerve conduction velocity through spectral analysis of the extracellular action potentials recorded from earthworm giant fibers. Med Biol Eng Comput 50:867\u2013875","journal-title":"Med Biol Eng Comput"},{"key":"1463_CR22","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1016\/j.medengphy.2012.04.008","volume":"35","author":"S Qiao","year":"2013","unstructured":"Qiao S, Yoshida K (2013) Influence of unit distance and conduction velocity on the spectra of extracellular action potentials recorded with intrafascicular electrodes. Med Eng Phys 35:116\u2013124","journal-title":"Med Eng Phys"},{"issue":"12","key":"1463_CR23","first-page":"1","volume":"2","author":"JD Rolston","year":"2009","unstructured":"Rolston JD, Gross RE, Potter SM (2009) A low-cost multielectrode system for data acquisition enabling real-time closed-loop processing with rapid recovery from stimulation artifacts. Front Neuroeng 2(12):1\u201317","journal-title":"Front Neuroeng"},{"key":"1463_CR24","doi-asserted-by":"crossref","unstructured":"Rossel O, Soulier F, Bernard S, Cathebras G (2011) Sensitivity of a frequency-selective electrode based on spatial spectral properties of the extracellular AP of myelinated nerve fibers. In: Annual international conference of the IEEE engineering in medicine and biology society (EMBC 2011) pp 5843\u20135846","DOI":"10.1109\/IEMBS.2011.6091445"},{"key":"1463_CR25","doi-asserted-by":"crossref","unstructured":"Rossel O, Soulier F, Cathebras G (2009) New electrode layout for internal selectivity of nerves. In: Annual international conference of the IEEE engineering in medicine and biology society, 2009 (EMBC 2009), pp 3798\u20133801","DOI":"10.1109\/IEMBS.2009.5334437"},{"key":"1463_CR26","doi-asserted-by":"crossref","unstructured":"Rossel O, Soulier F, Coulombe J, Bernard S, Cathebras G (2011) Fascicle-selective multi-contact cuff electrode. In: Annual international conference of the IEEE engineering in medicine and biology society (EMBC 2011) pp 2989\u20132992","DOI":"10.1109\/IEMBS.2011.6090820"},{"key":"1463_CR27","doi-asserted-by":"crossref","first-page":"777","DOI":"10.1016\/j.clinph.2010.01.001","volume":"121","author":"PM Rossini","year":"2010","unstructured":"Rossini PM, Micera S, Benvenuto A et al (2010) Double nerve intraneural interface implant on a human amputee for robotic hand control. Clin Neurophysiol 121:777\u2013783","journal-title":"Clin Neurophysiol"},{"key":"1463_CR28","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/0956-5663(95)96802-6","volume":"10","author":"WLC Rutten","year":"1995","unstructured":"Rutten WLC, Frieswijk TA, Smit JPA, Rozijn TH, Meier JH (1995) 3D neuro-electronic interface devices for neuromuscular control: design studies and realisation steps. Biosens Bioelectron 10:141\u2013153","journal-title":"Biosens Bioelectron"},{"key":"1463_CR29","doi-asserted-by":"crossref","first-page":"036016","DOI":"10.1088\/1741-2560\/10\/3\/036016","volume":"10","author":"M Schuettler","year":"2013","unstructured":"Schuettler M, Donaldson N, Seetohul V, Taylor J (2013) Fibre-selective recording from the peripheral nerves of frogs using a multi-electrode cuff. J Neural Eng 10:036016","journal-title":"J Neural Eng"},{"key":"1463_CR30","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1109\/86.788466","volume":"7","author":"KD Strange","year":"1999","unstructured":"Strange KD, Hoffer JA (1999) Restoration of use of paralyzed limb muscles using sensory nerve signals for state control of FES-assisted walking. IEEE Trans Rehabil Eng 7:289\u2013300","journal-title":"IEEE Trans Rehabil Eng"},{"key":"1463_CR31","unstructured":"Struijk JJ, Haugland MK, Thomsen M (1996) Fascicle selective recording with a nerve cuff electrode. In: Proceedings of the 18th annual international conference of the IEEE engineering in medicine and biology society, 1996. Bridging disciplines for biomedicine, vol 1, pp 361\u2013362"},{"key":"1463_CR32","doi-asserted-by":"crossref","unstructured":"Struijk JJ (1997) On the spectrum of nerve cuff electrode recordings. In: Proceedings of the 19th annual international conference of the IEEE engineering in medicine and biology society, 1997, vol 5, pp 2006\u20132007","DOI":"10.1109\/IEMBS.1996.656993"},{"key":"1463_CR33","doi-asserted-by":"crossref","first-page":"2457","DOI":"10.1016\/S0006-3495(97)78890-8","volume":"72","author":"JJ Struijk","year":"1997","unstructured":"Struijk JJ (1997) The extracellular potential of a myelinated nerve fiber in an unbounded medium and in nerve cuff models. Biophys J 72:2457\u20132469","journal-title":"Biophys J"},{"key":"1463_CR34","doi-asserted-by":"crossref","first-page":"634","DOI":"10.1007\/BF02347545","volume":"42","author":"J Taylor","year":"2004","unstructured":"Taylor J, Donaldson N, Winter J (2004) Multiple-electrode nerve cuffs for low-velocity and velocity-selective neural recording. Med Biol Eng Comput 42:634\u2013643","journal-title":"Med Biol Eng Comput"},{"key":"1463_CR35","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1007\/s11517-012-0874-z","volume":"50","author":"J Taylor","year":"2012","unstructured":"Taylor J, Schuettler M, Clarke C, Donaldson N (2012) The theory of velocity selective neural recording: a study based on simulation. Med Biol Eng Comput 50:309\u2013318","journal-title":"Med Biol Eng Comput"},{"key":"1463_CR36","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1109\/TNSRE.2009.2034072","volume":"17","author":"B Wodlinger","year":"2009","unstructured":"Wodlinger B, Durand DM (2009) Localization and recovery of peripheral neural sources with beamforming algorithms. IEEE Trans Neural Syst Rehabil Eng 17:461\u2013468","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"1463_CR37","first-page":"2160","volume-title":"Advances in neural information processing systems","author":"Z Yang","year":"2009","unstructured":"Yang Z, Zhao Q, Keefer E, Liu W (2009) Noise characterization, modeling, and reduction for in vivo neural recording. In: Bengio Y, Schuurmans D, Lafferty J, Williams CKI, Culotta A (eds) Advances in neural information processing systems, vol 22. MIT Press, Cambridge, pp 2160\u20132168"},{"key":"1463_CR38","doi-asserted-by":"crossref","first-page":"1461","DOI":"10.1109\/TBME.2005.851482","volume":"52","author":"PB Yoo","year":"2005","unstructured":"Yoo PB, Durand DM (2005) Selective recording of the canine hypoglossal nerve using a multicontact flat interface nerve electrode. IEEE Trans Biomed Eng 52:1461\u20131469","journal-title":"IEEE Trans Biomed Eng"},{"key":"1463_CR39","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1109\/10.481986","volume":"43","author":"K Yoshida","year":"1996","unstructured":"Yoshida K, Horch KW (1996) Closed-loop control of ankle position using muscle afferent feedback with functional neuromuscular stimulation. IEEE Trans Biomed Eng 43:167\u2013176","journal-title":"IEEE Trans Biomed Eng"},{"key":"1463_CR40","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1109\/TNSRE.2009.2023301","volume":"17","author":"J Zariffa","year":"2009","unstructured":"Zariffa J, Nagai MK, Daskalakis ZJ, Popovic MR (2009) Influence of the number and location of recording contacts on the selectivity of a nerve cuff electrode. IEEE Trans Neural Syst Rehabil Eng 17:420\u2013427","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"1463_CR41","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1109\/TNSRE.2010.2091429","volume":"19","author":"J Zariffa","year":"2011","unstructured":"Zariffa J, Nagai MK, Schuettler M, Stieglitz T, Daskalakis ZJ, Popovic MR (2011) Use of an experimentally derived leadfield in the peripheral nerve pathway discrimination problem. IEEE Trans Neural Syst Rehabil Eng 19:147\u2013156","journal-title":"IEEE Trans Neural Syst Rehabil Eng"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-016-1463-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11517-016-1463-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-016-1463-3","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,1]],"date-time":"2019-06-01T12:10:46Z","timestamp":1559391046000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11517-016-1463-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,3,25]]},"references-count":41,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2016,8]]}},"alternative-id":["1463"],"URL":"https:\/\/doi.org\/10.1007\/s11517-016-1463-3","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"type":"print","value":"0140-0118"},{"type":"electronic","value":"1741-0444"}],"subject":[],"published":{"date-parts":[[2016,3,25]]}}}