{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T17:01:53Z","timestamp":1777568513613,"version":"3.51.4"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2017,2,4]],"date-time":"2017-02-04T00:00:00Z","timestamp":1486166400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2017,9]]},"DOI":"10.1007\/s11517-017-1625-y","type":"journal-article","created":{"date-parts":[[2017,2,4]],"date-time":"2017-02-04T00:54:51Z","timestamp":1486169691000},"page":"1579-1588","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":19,"title":["Pseudo-real-time low-pass filter in ECG, self-adjustable to the frequency spectra of the waves"],"prefix":"10.1007","volume":"55","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9496-872X","authenticated-orcid":false,"given":"Ivaylo","family":"Christov","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tatyana","family":"Neycheva","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ramun","family":"Schmid","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Todor","family":"Stoyanov","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roger","family":"Ab\u00e4cherli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2017,2,4]]},"reference":[{"key":"1625_CR1","first-page":"1089","volume":"41","author":"G Bortolan","year":"2014","unstructured":"Bortolan G, Christov I (2014) Dynamic filtration of high-frequency noise in ECG signal. Comput Cardiol 41:1089\u20131092","journal-title":"Comput Cardiol"},{"key":"1625_CR2","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1016\/j.bspc.2015.02.003","volume":"18","author":"G Bortolan","year":"2015","unstructured":"Bortolan G, Christov I, Simova I, Dotsinsky I (2015) Noise processing in exercise ECG stress test for the analysis and the clinical characterization of QRS and T wave alternans. Biomed Sign Process Control 18:378\u2013385. doi:\n                        10.1016\/j.bspc.2015.02.003","journal-title":"Biomed Sign Process Control"},{"issue":"10","key":"1625_CR3","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1016\/S1350-4533(99)00098-3","volume":"21","author":"II Christov","year":"1999","unstructured":"Christov II, Daskalov IK (1999) Filtering of electromyogram artifacts from the electrocardiogram. Med Eng Phys 21(10):731\u2013736","journal-title":"Med Eng Phys"},{"key":"1625_CR4","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1097\/00004669-199603000-00014","volume":"21","author":"I Dotsinsky","year":"1996","unstructured":"Dotsinsky I, Christov I, Daskalov I (1996) Assessment of metrological characteristics of digital electrocardiographs. J Clin Eng 21:156\u2013160","journal-title":"J Clin Eng"},{"key":"1625_CR5","doi-asserted-by":"crossref","unstructured":"Dotsinsky I, Mihov J (2008) Tremor suppression in ECG. Biomed Eng Online 7:29. \n                        https:\/\/biomedical-engineering-online.biomedcentral.com\/articles\/10.1186\/1475-925X-7-29","DOI":"10.1186\/1475-925X-7-29"},{"key":"1625_CR6","unstructured":"European Conformance Testing Services for Computerizes Electrocardiography (2005) CTS ECG test atlas. Institute for Biosignal Processing and System Analysis, Garching"},{"issue":"4","key":"1625_CR7","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1016\/j.jelectrocard.2009.03.002","volume":"42","author":"J Garc\u00eda-Niebla","year":"2009","unstructured":"Garc\u00eda-Niebla J, Serra-Autonell G (2009) Effects of inadequate low-pass filter application. J Electrocardiol 42(4):303\u2013304","journal-title":"J Electrocardiol"},{"key":"1625_CR8","unstructured":"Gotchev A, Christov I, Egiazarian K (2002) Denoising the electrocardiogram from electromyogram artifacts by combined transform-domain and dynamic approximation method. In: International conference on acoustics, speech and signal processing (ICASSP2002), Orlando, FL, USA, 13\u201317 May, pp 3872\u20133875"},{"issue":"8","key":"1625_CR9","first-page":"55","volume":"2","author":"J Joy","year":"2013","unstructured":"Joy J, Manimegalai P (2013) Wavelet based EMG artifact removal from ECG signal. J Eng Comp Appl Sci 2(8):55\u201358","journal-title":"J Eng Comp Appl Sci"},{"key":"1625_CR10","doi-asserted-by":"crossref","first-page":"1109","DOI":"10.1016\/j.jacc.2007.01.024","volume":"49","author":"P Kligfield","year":"2007","unstructured":"Kligfield P, Gettes LS, Bailey JJ et al (2007) Recommendations for the standardization and interpretation of the electrocardiogram: part I: the electrocardiogram and its technology. A scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society endorsed by the International Society for Computerized Electrocardiology. J Am Coll Cardiol 49:1109\u20131127","journal-title":"J Am Coll Cardiol"},{"key":"1625_CR11","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1016\/j.amjcard.2006.09.123","volume":"99","author":"P Kligfield","year":"2007","unstructured":"Kligfield P, Okin PM (2007) Prevalence and clinical implications of improper filter settings in routine electrocardiography. Am J Cardiol 99:711\u2013713","journal-title":"Am J Cardiol"},{"issue":"1","key":"1625_CR12","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.jelectrocard.2013.10.001","volume":"47","author":"M Nakagawa","year":"2014","unstructured":"Nakagawa M, Tsunemitsu C, Katoh S et al (2014) Effect of ECG filter settings on J-waves. J Electrocardiol 47(1):7\u201311","journal-title":"J Electrocardiol"},{"key":"1625_CR13","doi-asserted-by":"crossref","first-page":"1627","DOI":"10.1021\/ac60214a047","volume":"36","author":"A Savitzky","year":"1964","unstructured":"Savitzky A, Golay M (1964) Smoothing and differentiation of data by simplified least squares procedures. Anal Chem 36:1627\u20131639","journal-title":"Anal Chem"},{"issue":"1","key":"1625_CR14","first-page":"22","volume":"6","author":"RA Sayyad","year":"2016","unstructured":"Sayyad RA, Mundada K (2016) Enhancement and denoising of ECG signal using extended Kalman filter and extended Kalman smoother. J Innov Electron Commun Eng 6(1):22\u201326","journal-title":"J Innov Electron Commun Eng"},{"key":"1625_CR15","first-page":"409","volume":"41","author":"I Simova","year":"2014","unstructured":"Simova I, Christov I, Kambova L, Bortolan G, Katova T (2014) QRS and T loops area changes during haemodialysis. Comput Cardiol 41:409\u2013412","journal-title":"Comput Cardiol"},{"key":"1625_CR16","first-page":"60","volume":"14","author":"Subcommittee on Instrumentation Committee on Electrocardiography\u2014American Heart Association","year":"1967","unstructured":"Subcommittee on Instrumentation Committee on Electrocardiography\u2014American Heart Association (1967) Recommendation for instruments in electrocardiography and vectorcardiography. IEEE Trans Biomed Eng 14:60\u201368","journal-title":"IEEE Trans Biomed Eng"},{"issue":"1","key":"1625_CR17","first-page":"5","volume":"21","author":"N Tulyakova","year":"2017","unstructured":"Tulyakova N (2017) Locally-adaptive Myriad filters for processing ECG signals in real time. Int J Bioautom 21(1):5\u201314","journal-title":"Int J Bioautom"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11517-017-1625-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-017-1625-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-017-1625-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,8,23]],"date-time":"2017-08-23T00:03:53Z","timestamp":1503446633000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11517-017-1625-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,2,4]]},"references-count":17,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2017,9]]}},"alternative-id":["1625"],"URL":"https:\/\/doi.org\/10.1007\/s11517-017-1625-y","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,2,4]]}}}