{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T00:43:35Z","timestamp":1790729015388,"version":"4.1.0"},"reference-count":44,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2018,6,11]],"date-time":"2018-06-11T00:00:00Z","timestamp":1528675200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"name":"Proclinic","award":["A-285"],"award-info":[{"award-number":["A-285"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2018,12]]},"DOI":"10.1007\/s11517-018-1846-8","type":"journal-article","created":{"date-parts":[[2018,6,11]],"date-time":"2018-06-11T01:41:56Z","timestamp":1528681316000},"page":"2233-2244","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Complete mechanical characterization of an external hexagonal implant connection: in vitro study, 3D FEM, and probabilistic fatigue"],"prefix":"10.1007","volume":"56","author":[{"given":"Mar\u00eda","family":"Prados-Privado","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S\u00e9rgio A.","family":"Gehrke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rosa","family":"Rojo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juan Carlos","family":"Prados-Frutos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,6,11]]},"reference":[{"key":"1846_CR1","doi-asserted-by":"publisher","first-page":"346","DOI":"10.1111\/j.1365-2842.2004.01475.x","volume":"32","author":"SK Kim","year":"2005","unstructured":"Kim SK, Lee JB, Koak JY et al (2005) An abutment screw loosening study of a diamond like carbon-coated CP titanium implant. J Oral Rehabil 32:346\u2013350. \n                    https:\/\/doi.org\/10.1111\/j.1365-2842.2004.01475.x","journal-title":"J Oral Rehabil"},{"key":"1846_CR2","doi-asserted-by":"publisher","first-page":"267","DOI":"10.4103\/1305-7456.115407","volume":"7","author":"W Brandt","year":"2013","unstructured":"Brandt W, Claro Neves A, de Lima AP et al (2013) Stability of external and internal implant connections after a fatigue test. Eur J Dent 7:267\u2013271. \n                    https:\/\/doi.org\/10.4103\/1305-7456.115407","journal-title":"Eur J Dent"},{"key":"1846_CR3","doi-asserted-by":"publisher","first-page":"1201","DOI":"10.1016\/j.msec.2016.10.025","volume":"71","author":"JM Cordeiro","year":"2017","unstructured":"Cordeiro JM, Bar\u00e3o VAR (2017) Is there scientific evidence favoring the substitution of commercially pure titanium with titanium alloys for the manufacture of dental implants? Mater Sci Eng C 71:1201\u20131215. \n                    https:\/\/doi.org\/10.1016\/j.msec.2016.10.025","journal-title":"Mater Sci Eng C"},{"issue":"5","key":"1846_CR4","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1007\/s10856-017-5879-6","volume":"28","author":"AM Prado","year":"2017","unstructured":"Prado AM, Pereira J, Silva FS, Henriques B, Nascimento RM, Benfatti CAM, L\u00f3pez-L\u00f3pez J, Souza JCM (2017) Wear of Morse taper and external hexagon implant joints after abutment removal. J Mater Sci Mater Med 28(5):65. \n                    https:\/\/doi.org\/10.1007\/s10856-017-5879-6","journal-title":"J Mater Sci Mater Med"},{"key":"1846_CR5","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1016\/j.jmbbm.2016.05.011","volume":"62","author":"R Coray","year":"2016","unstructured":"Coray R, Zeltner M, \u00d6zcan M (2016) Fracture strength of implant abutments after fatigue testing: a systematic review and a meta-analysis. J Mech Behav Biomed Mater 62:333\u2013346. \n                    https:\/\/doi.org\/10.1016\/j.jmbbm.2016.05.011","journal-title":"J Mech Behav Biomed Mater"},{"key":"1846_CR6","doi-asserted-by":"publisher","first-page":"299","DOI":"10.1016\/j.prosdent.2013.08.023","volume":"112","author":"F Alqahtani","year":"2014","unstructured":"Alqahtani F, Flinton R (2014) Postfatigue fracture resistance of modified prefabricated zirconia implant abutments. J Prosthet Dent 112:299\u2013305. \n                    https:\/\/doi.org\/10.1016\/j.prosdent.2013.08.023","journal-title":"J Prosthet Dent"},{"key":"1846_CR7","doi-asserted-by":"publisher","first-page":"2196","DOI":"10.1097\/SCS.0000000000001977","volume":"26","author":"CEE Rezende","year":"2015","unstructured":"Rezende CEE, Chase-Diaz M, Costa MD, Albarracin ML, Paschoeto G, Sousa EAC, Rubo JH, Borges AFS (2015) Stress distribution in single dental implant system. J Craniofac Surg 26:2196\u20132200. \n                    https:\/\/doi.org\/10.1097\/SCS.0000000000001977","journal-title":"J Craniofac Surg"},{"key":"1846_CR8","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1590\/0103-6440201801746","volume":"29","author":"SLD Moraes","year":"2018","unstructured":"Moraes SLD, Verri FR, J\u00fanior SJF et al (2018) Three-dimensional finite element analysis of varying diameter and connection type in implants swith high crown-implant ratio. Braz Dent J 29:36\u201342. \n                    https:\/\/doi.org\/10.1590\/0103-6440201801746","journal-title":"Braz Dent J"},{"key":"1846_CR9","doi-asserted-by":"publisher","first-page":"770","DOI":"10.1080\/10255842.2017.1302432","volume":"20","author":"K Solberg","year":"2017","unstructured":"Solberg K, Heinemann F, Pellikaan P, Keilig L, Stark H, Bourauel C, Hasan I (2017) Finite element analysis of different loading conditions for implant-supported overdentures supported by conventional or mini implants. Comput Methods Biomech Biomed Engin 20:770\u2013782. \n                    https:\/\/doi.org\/10.1080\/10255842.2017.1302432","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"1846_CR10","unstructured":"ISO 14801:2007(E) (2007) Dentistry\u2014implants\u2014dynamic fatigue test for endosseous dental implants, 2nd edn"},{"key":"1846_CR11","first-page":"1","volume":"64","author":"SA Gehrke","year":"2015","unstructured":"Gehrke SA, De Carvalho Serra R (2015) Load fatigue performance of conical implant-abutment connection: effect of torque level and interface junction. Minerva Stomatol 64:1\u20137","journal-title":"Minerva Stomatol"},{"key":"1846_CR12","doi-asserted-by":"publisher","first-page":"264","DOI":"10.11607\/jomi.4797","volume":"32","author":"C Lima de Andrade","year":"2017","unstructured":"Lima de Andrade C, Carvalho M, Bordin D, da Silva W, del Bel Cury A, Sotto-Maior B (2017) Biomechanical behavior of the dental implant macrodesign. Int J Oral Maxillofac Implants 32:264\u2013270. \n                    https:\/\/doi.org\/10.11607\/jomi.4797","journal-title":"Int J Oral Maxillofac Implants"},{"key":"1846_CR13","doi-asserted-by":"publisher","first-page":"259","DOI":"10.11607\/jomi.4773","volume":"32","author":"HN Al-Otaibi","year":"2017","unstructured":"Al-Otaibi HN, Almutairi A, Alfarraj J, Algesadi W (2017) The effect of torque application technique on screw preload of implant-supported prostheses. Int J Oral Maxillofac Implants 32:259\u2013263. \n                    https:\/\/doi.org\/10.11607\/jomi.4773","journal-title":"Int J Oral Maxillofac Implants"},{"key":"1846_CR14","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1097\/ID.0b013e31823fcbce","volume":"21","author":"WG Assun\u00e7\u00e3o","year":"2012","unstructured":"Assun\u00e7\u00e3o WG, Delben JA, Tabata LF, Bar\u00e3o VAR, Gomes \u00c9A, Garcia IR Jr (2012) Preload evaluation of different screws in external hexagon joint. Implant Dent 21:46\u201350. \n                    https:\/\/doi.org\/10.1097\/ID.0b013e31823fcbce","journal-title":"Implant Dent"},{"key":"1846_CR15","doi-asserted-by":"publisher","first-page":"599","DOI":"10.1067\/mpr.2001.115250","volume":"85","author":"SA Hoyer","year":"2001","unstructured":"Hoyer SA, Stanford CM, Buranadham S, Fridrich T, Wagner J, Gratton D (2001) Dynamic fatigue properties of the dental implant\u2013abutment interface: joint opening in wide-diameter versus standard-diameter hex-type implants. J Prosthet Dent 85:599\u2013607. \n                    https:\/\/doi.org\/10.1067\/mpr.2001.115250","journal-title":"J Prosthet Dent"},{"key":"1846_CR16","first-page":"435","volume":"6","author":"LC Breeding","year":"1993","unstructured":"Breeding LC, Dixon DL, Nelson EW, Tietge JD (1993) Torque required to loosen single-tooth implant abutment screws before and after simulated function. Int J Prosthodont 6:435\u2013439","journal-title":"Int J Prosthodont"},{"key":"1846_CR17","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1016\/j.prosdent.2016.02.015","volume":"116","author":"SA Gehrke","year":"2016","unstructured":"Gehrke SA, Poncio da Silva PM, Calvo Guirado JL, Delgado-Ruiz RA, Dedavid BA, Aline Nagasawa M, Shibli JA (2016) Mechanical behavior of zirconia and titanium abutments before and after cyclic load application. J Prosthet Dent 116:529\u2013535. \n                    https:\/\/doi.org\/10.1016\/j.prosdent.2016.02.015","journal-title":"J Prosthet Dent"},{"key":"1846_CR18","doi-asserted-by":"publisher","first-page":"e218","DOI":"10.1016\/j.dental.2012.05.004","volume":"28","author":"AC Freitas-J\u00fanior","year":"2012","unstructured":"Freitas-J\u00fanior AC, Rocha EP, Bonfante EA, Almeida EO, Anchieta RB, Martini AP, Assun\u00e7\u00e3o WG, Silva NRFA, Coelho PG (2012) Biomechanical evaluation of internal and external hexagon platform switched implant-abutment connections: an in vitro laboratory and three-dimensional finite element analysis. Dent Mater 28:e218\u2013e228. \n                    https:\/\/doi.org\/10.1016\/j.dental.2012.05.004","journal-title":"Dent Mater"},{"key":"1846_CR19","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1080\/10255842.2010.527834","volume":"15","author":"MA P\u00e9rez","year":"2012","unstructured":"P\u00e9rez MA, Prados-Frutos JC, Bea JA, Doblar\u00e9 M (2012) Stress transfer properties of different commercial dental implants: a finite element study. Comput Methods Biomech Biomed Engin 15:263\u2013273. \n                    https:\/\/doi.org\/10.1080\/10255842.2010.527834","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"1846_CR20","doi-asserted-by":"publisher","first-page":"239","DOI":"10.2334\/josnusd.55.239","volume":"55","author":"A Bacchi","year":"2013","unstructured":"Bacchi A, Consani RLX, Mesquita MF, dos Santos MBF (2013) Stress distribution in fixed-partial prosthesis and peri-implant bone tissue with different framework materials and vertical misfit levels: a three-dimensional finite element analysis. J Oral Sci 55:239\u2013244","journal-title":"J Oral Sci"},{"key":"1846_CR21","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1016\/j.msec.2016.04.004","volume":"65","author":"HE Peixoto","year":"2016","unstructured":"Peixoto HE, Bordin D, Del Bel Cury AA et al (2016) The role of prosthetic abutment material on the stress distribution in a maxillary single implant-supported fixed prosthesis. Mater Sci Eng C 65:90\u201396. \n                    https:\/\/doi.org\/10.1016\/j.msec.2016.04.004","journal-title":"Mater Sci Eng C"},{"key":"1846_CR22","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1016\/S0927-0256(02)00246-X","volume":"25","author":"JA Bea","year":"2002","unstructured":"Bea JA, Doblar\u00e9 M (2002) Enhanced B-PFEM model for fatigue life prediction of metals during crack propagation. Comput Mater Sci 25:14\u201333. \n                    https:\/\/doi.org\/10.1016\/S0927-0256(02)00246-X","journal-title":"Comput Mater Sci"},{"key":"1846_CR23","volume-title":"Fracture mechanics: fundamentals and applications","author":"TL Anderson","year":"1995","unstructured":"Anderson TL (1995) Fracture mechanics: fundamentals and applications. CRC Press, Boca Rat\u00f3n, Florida"},{"key":"1846_CR24","volume-title":"Methods of structural safety","author":"HO Madsen","year":"1986","unstructured":"Madsen HO, Krenk S, Lind NC (1986) Methods of structural safety. Prentice-Hall, Englewood Cliffs, New Jersey"},{"key":"1846_CR25","doi-asserted-by":"publisher","first-page":"1583","DOI":"10.1080\/10255842.2016.1170124","volume":"19","author":"M Prados-Privado","year":"2016","unstructured":"Prados-Privado M, Prados-Frutos J, Calvo-Guirado J, Bea J (2016) A random fatigue of mechanize titanium abutment studied with Markoff chain and stochastic finite element formulation. Comput Methods Biomech Biomed Engin 19:1583\u20131591. \n                    https:\/\/doi.org\/10.1080\/10255842.2016.1170124","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"1846_CR26","doi-asserted-by":"publisher","first-page":"e562","DOI":"10.1111\/cid.12285","volume":"17","author":"S Sridhar","year":"2015","unstructured":"Sridhar S, Wilson TG Jr, Palmer KL, Valderrama P, Mathew MT, Prasad S, Jacobs M, Gindri IM, Rodrigues DC (2015) In vitro investigation of the effect of oral bacteria in the surface oxidation of dental implants. Clin Implant Dent Relat Res 17:e562\u2013e575. \n                    https:\/\/doi.org\/10.1111\/cid.12285","journal-title":"Clin Implant Dent Relat Res"},{"key":"1846_CR27","first-page":"826","volume":"19","author":"JS Guindy","year":"2004","unstructured":"Guindy JS, Schiel H, Schmidli F, Wirz J (2004) Corrosion at the marginal gap of implant-supported suprastructures and implant failure. Int J Oral Maxillofac Implants 19:826\u2013831","journal-title":"Int J Oral Maxillofac Implants"},{"key":"1846_CR28","doi-asserted-by":"publisher","first-page":"3","DOI":"10.4103\/0975-5950.168233","volume":"6","author":"S Gupta","year":"2015","unstructured":"Gupta S, Gupta H, Tandan A (2015) Technical complications of implant-causes and management: a comprehensive review. Natl J Maxillofac Surg 6:3\u20138. \n                    https:\/\/doi.org\/10.4103\/0975-5950.168233","journal-title":"Natl J Maxillofac Surg"},{"key":"1846_CR29","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1902\/jop.1998.69.2.185","volume":"69","author":"A Piattelli","year":"1998","unstructured":"Piattelli A, Scarano A, Piattelli M, Vaia E, Matarasso S (1998) Hollow implants retrieved for fracture: a light and scanning electron microscope analysis of 4 cases. J Periodontol 69:185\u2013189. \n                    https:\/\/doi.org\/10.1902\/jop.1998.69.2.185","journal-title":"J Periodontol"},{"key":"1846_CR30","doi-asserted-by":"publisher","first-page":"477","DOI":"10.1097\/00008505-199309000-00018","volume":"7","author":"DE Tolman","year":"1992","unstructured":"Tolman DE, Laney WR (1992) Tissue-integrated prosthesis complications. Int J Oral Maxillofac Implants 7:477\u2013484. \n                    https:\/\/doi.org\/10.1097\/00008505-199309000-00018","journal-title":"Int J Oral Maxillofac Implants"},{"key":"1846_CR31","doi-asserted-by":"publisher","first-page":"613","DOI":"10.1097\/ID.0000000000000453","volume":"25","author":"E Marchetti","year":"2016","unstructured":"Marchetti E, Ratta S, Mummolo S, Tecco S, Pecci R, Bedini R, Marzo G (2016) Mechanical reliability evaluation of an oral implant-abutment system according to UNI EN ISO 14801 fatigue test protocol. Implant Dent 25:613\u2013618. \n                    https:\/\/doi.org\/10.1097\/ID.0000000000000453","journal-title":"Implant Dent"},{"key":"1846_CR32","doi-asserted-by":"publisher","first-page":"388","DOI":"10.4047\/jap.2016.8.5.388","volume":"8","author":"S-J Park","year":"2016","unstructured":"Park S-J, Lee S-W, Leesungbok R, Ahn S-J (2016) Influence of the connection design and titanium grades of the implant complex on resistance under static loading. J Adv Prosthodont 8:388\u2013395. \n                    https:\/\/doi.org\/10.4047\/jap.2016.8.5.388","journal-title":"J Adv Prosthodont"},{"key":"1846_CR33","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1016\/j.jmbbm.2016.11.018","volume":"66","author":"A Alsahhaf","year":"2017","unstructured":"Alsahhaf A, Spies BC, Vach K, Kohal R-J (2017) Fracture resistance of zirconia-based implant abutments after artificial long-term aging. J Mech Behav Biomed Mater 66:224\u2013232. \n                    https:\/\/doi.org\/10.1016\/j.jmbbm.2016.11.018","journal-title":"J Mech Behav Biomed Mater"},{"key":"1846_CR34","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1563\/aaid-joi-D-16-00010","volume":"42","author":"A Patankar","year":"2016","unstructured":"Patankar A, Kheur M, Kheur S, Lakha T, Burhanpurwala M (2016) Fracture resistance of implant abutments following abutment alterations by milling the margins: an in vitro study. J Oral Implantol 42:464\u2013468. \n                    https:\/\/doi.org\/10.1563\/aaid-joi-D-16-00010","journal-title":"J Oral Implantol"},{"key":"1846_CR35","doi-asserted-by":"publisher","first-page":"396","DOI":"10.1111\/clr.13135","volume":"29","author":"H Takata","year":"2018","unstructured":"Takata H, Komine F, Honda J, Blatz M, Matsumura H (2018) An in vitro evaluation of fracture load of implant-supported zirconia-based prostheses fabricated with different veneer materials. Clin Oral Implants Res 29:396\u2013403. \n                    https:\/\/doi.org\/10.1111\/clr.13135","journal-title":"Clin Oral Implants Res"},{"key":"1846_CR36","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1111\/cid.12572","volume":"20","author":"BR Chrcanovic","year":"2018","unstructured":"Chrcanovic BR, Kisch J, Albrektsson T, Wennerberg A (2018) Factors influencing the fracture of dental implants. Clin Implant Dent Relat Res 20:58\u201367. \n                    https:\/\/doi.org\/10.1111\/cid.12572","journal-title":"Clin Implant Dent Relat Res"},{"key":"1846_CR37","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1097\/00008505-200204000-00014","volume":"11","author":"N Tagger Green","year":"2002","unstructured":"Tagger Green N, Machtei EE, Horwitz J, Peled M (2002) Fracture of dental implants: literature review and report of a case. Implant Dent 11:137\u2013143","journal-title":"Implant Dent"},{"key":"1846_CR38","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1515\/bmt-2012-0108","volume":"58","author":"R Amid","year":"2013","unstructured":"Amid R, Raoofi S, Kadkhodazadeh M, Movahhedi MR, Khademi M (2013) Effect of microthread design of dental implants on stress and strain patterns: a three-dimensional finite element analysis. Biomed Tech (Berl) 58:457\u2013467. \n                    https:\/\/doi.org\/10.1515\/bmt-2012-0108","journal-title":"Biomed Tech (Berl)"},{"key":"1846_CR39","doi-asserted-by":"publisher","first-page":"562","DOI":"10.1111\/cid.12143","volume":"17","author":"R Chowdhary","year":"2015","unstructured":"Chowdhary R, Halldin A, Jimbo R, Wennerberg A (2015) Influence of micro threads alteration on osseointegration and primary stability of implants: an FEA and in vivo analysis in rabbits. Clin Implant Dent Relat Res 17:562\u2013569. \n                    https:\/\/doi.org\/10.1111\/cid.12143","journal-title":"Clin Implant Dent Relat Res"},{"key":"1846_CR40","doi-asserted-by":"publisher","first-page":"1117","DOI":"10.1177\/0954411914557713","volume":"228","author":"O Pekta","year":"2014","unstructured":"Pekta O, Tonuk E (2014) Mechanical design, analysis, and laboratory testing of a dental implant with axial flexibility similar to natural tooth with periodontal ligament. Proc Inst Mech Eng Part H J Eng Med 228:1117\u20131125. \n                    https:\/\/doi.org\/10.1177\/0954411914557713","journal-title":"Proc Inst Mech Eng Part H J Eng Med"},{"key":"1846_CR41","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1016\/j.msec.2016.02.015","volume":"63","author":"K Wang","year":"2016","unstructured":"Wang K, Geng J, Jones D, Xu W (2016) Comparison of the fracture resistance of dental implants with different abutment taper angles. Mater Sci Eng C 63:164\u2013171. \n                    https:\/\/doi.org\/10.1016\/j.msec.2016.02.015","journal-title":"Mater Sci Eng C"},{"key":"1846_CR42","doi-asserted-by":"publisher","first-page":"16","DOI":"10.3390\/dj4020016","volume":"4","author":"K Shemtov-Yona","year":"2016","unstructured":"Shemtov-Yona K, Rittel D (2016) Fatigue of dental implants: facts and fallacies. Dent J 4:16. \n                    https:\/\/doi.org\/10.3390\/dj4020016","journal-title":"Dent J"},{"key":"1846_CR43","doi-asserted-by":"publisher","first-page":"971","DOI":"10.1016\/j.simpat.2008.05.009","volume":"16","author":"L Baggi","year":"2008","unstructured":"Baggi L, Cappelloni I, Maceri F, Vairo G (2008) Stress-based performance evaluation of osseointegrated dental implants by finite-element simulation. Simul Model Pract Theory 16:971\u2013987. \n                    https:\/\/doi.org\/10.1016\/j.simpat.2008.05.009","journal-title":"Simul Model Pract Theory"},{"key":"1846_CR44","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1016\/j.jpor.2017.03.006","volume":"62","author":"S Yamaguchi","year":"2018","unstructured":"Yamaguchi S, Yamanishi Y, Machado LS, Matsumoto S, Tovar N, Coelho PG, Thompson VP, Imazato S (2018) In vitro fatigue tests and in silico finite element analysis of dental implants with different fixture\/abutment joint types using computer-aided design models. J Prosthodont Res 62:24\u201330. \n                    https:\/\/doi.org\/10.1016\/j.jpor.2017.03.006","journal-title":"J Prosthodont Res"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11517-018-1846-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-018-1846-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-018-1846-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,10]],"date-time":"2019-06-10T23:15:13Z","timestamp":1560208513000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11517-018-1846-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,6,11]]},"references-count":44,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2018,12]]}},"alternative-id":["1846"],"URL":"https:\/\/doi.org\/10.1007\/s11517-018-1846-8","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,6,11]]},"assertion":[{"value":"7 September 2017","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 May 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 June 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}