{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,21]],"date-time":"2026-01-21T23:47:59Z","timestamp":1769039279196,"version":"3.49.0"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,11,18]],"date-time":"2019-11-18T00:00:00Z","timestamp":1574035200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,11,18]],"date-time":"2019-11-18T00:00:00Z","timestamp":1574035200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"name":"Saxony Ministry for Science and Arts","award":["4-7531.50-02-876-10\/1"],"award-info":[{"award-number":["4-7531.50-02-876-10\/1"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2020,1]]},"DOI":"10.1007\/s11517-019-02059-x","type":"journal-article","created":{"date-parts":[[2019,11,18]],"date-time":"2019-11-18T13:01:43Z","timestamp":1574082103000},"page":"55-65","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Experimental validation of adaptive pedicle screws\u2014a novel implant concept using shape memory alloys"],"prefix":"10.1007","volume":"58","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7864-9446","authenticated-orcid":false,"given":"Michael","family":"Werner","sequence":"first","affiliation":[]},{"given":"Niels","family":"Hammer","sequence":"additional","affiliation":[]},{"given":"Christian","family":"Rotsch","sequence":"additional","affiliation":[]},{"given":"Isabell","family":"Berthold","sequence":"additional","affiliation":[]},{"given":"Mario","family":"Leimert","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2019,11,18]]},"reference":[{"key":"2059_CR1","unstructured":"(2006) Cold Injury. In: Mostafa G, Cathey L, Greene FL (Hrsg) Review of Surgery. Springer New York, S 89\u201390"},{"issue":"5","key":"2059_CR2","doi-asserted-by":"publisher","first-page":"593","DOI":"10.1093\/ons\/opy186","volume":"16","author":"Ori Barzilai","year":"2018","unstructured":"Barzilai O, McLaughlin L, Lis E, Reiner AS, Bilsky MH, Laufer I (2018) Utility of cement augmentation via percutaneous fenestrated pedicle screws for stabilization of cancer related spinal instability. Oper Neurosurg (Hagerstown). https:\/\/doi.org\/10.1093\/ons\/opy186","journal-title":"Operative Neurosurgery"},{"key":"2059_CR3","unstructured":"B\u00f6hm A, Rotsch C, Werner M, Hemmann F, Scherer S, Senf B, Drossel W-G, Hannemann C, Tscherwinski T Verankerungselement mit funktionalem Schaft und modulares Verankerungssystem. DE201110106653 20110705"},{"key":"2059_CR4","unstructured":"B\u00f6hm A, Hemmann F, Kunze H, Rotsch C, Scherer S, Senf B, Werner M (Hrsg) (2011) Integration of shape memory alloy into a pedicle screw for increasing the pullout strength. BMT 2011, Biomedizinische Technik. Proceedings 45. DGBMT Jahrestagung. De Gruyter, Berlin"},{"issue":"8","key":"2059_CR5","doi-asserted-by":"publisher","first-page":"1063","DOI":"10.1007\/s00402-016-2487-8","volume":"136","author":"J Bredow","year":"2016","unstructured":"Bredow J, Boese CK, Werner CML, Siewe J, Lohrer L, Zarghooni K, Eysel P, Scheyerer MJ (2016) Predictive validity of preoperative CT scans and the risk of pedicle screw loosening in spinal surgery. Arch Orthop Trauma Surg 136(8):1063\u20131067. https:\/\/doi.org\/10.1007\/s00402-016-2487-8","journal-title":"Arch Orthop Trauma Surg"},{"issue":"8","key":"2059_CR6","doi-asserted-by":"publisher","first-page":"613","DOI":"10.1016\/j.clinbiomech.2009.05.002","volume":"24","author":"L-H Chen","year":"2009","unstructured":"Chen L-H, Tai C-L, Lai P-L, Lee D-M, Tsai T-T, Fu T-S, Niu C-C, Chen W-J (2009) Pullout strength for cannulated pedicle screws with bone cement augmentation in severely osteoporotic bone: influences of radial hole and pilot hole tapping. Clin Biomech (Bristol, Avon) 24(8):613\u2013618. https:\/\/doi.org\/10.1016\/j.clinbiomech.2009.05.002","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"11","key":"2059_CR7","doi-asserted-by":"publisher","first-page":"1416","DOI":"10.1016\/j.medengphy.2014.05.003","volume":"36","author":"Y-L Chen","year":"2014","unstructured":"Chen Y-L, Chen W-C, Chou C-W, Chen J-W, Chang C-M, Lai Y-S, Cheng C-K, Wang S-T (2014) Biomechanical study of expandable pedicle screw fixation in severe osteoporotic bone comparing with conventional and cement-augmented pedicle screws. Med Eng Phys 36(11):1416\u20131420. https:\/\/doi.org\/10.1016\/j.medengphy.2014.05.003","journal-title":"Med Eng Phys"},{"issue":"1","key":"2059_CR8","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1016\/j.jspd.2018.06.007","volume":"7","author":"J Clin","year":"2019","unstructured":"Clin J, Le Nav\u00e9aux F, Driscoll M, Mac-Thiong J-M, Labelle H, Parent S, Shah SA, Lonner BS, Newton PO, Serhan H (2019) Biomechanical comparison of the load-sharing capacity of high and low implant density constructs with three types of pedicle screws for the instrumentation of adolescent idiopathic scoliosis. Spine Deform 7(1):2\u201310. https:\/\/doi.org\/10.1016\/j.jspd.2018.06.007","journal-title":"Spine Deform"},{"issue":"2","key":"2059_CR9","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1016\/S1529-9430(01)00020-1","volume":"1","author":"SD Cook","year":"2001","unstructured":"Cook SD, Barbera J, Rubi M, Salkeld SL, Whitecloud TS (2001) Lumbosacral fixation using expandable pedicle screws. An alternative in reoperation and osteoporosis. Spine J 1(2):109\u2013114","journal-title":"Spine J"},{"issue":"5","key":"2059_CR10","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1007\/s00068-013-0310-6","volume":"39","author":"A El Saman","year":"2013","unstructured":"El Saman A, Meier S, Sander A, Kelm A, Marzi I, Laurer H (2013) Reduced loosening rate and loss of correction following posterior stabilization with or without PMMA augmentation of pedicle screws in vertebral fractures in the elderly. Eur J Trauma Emerg Surg 39(5):455\u2013460. https:\/\/doi.org\/10.1007\/s00068-013-0310-6","journal-title":"Eur J Trauma Emerg Surg"},{"issue":"1","key":"2059_CR11","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1055\/s-2007-960588","volume":"20","author":"H Fischer","year":"2007","unstructured":"Fischer H, Welle A, Vogel B (2007) Anwendungen von Formged\u00e4chtnislegierungen bei medizinischen Instrumenten. Endosk heute 20(1):80\u201382. https:\/\/doi.org\/10.1055\/s-2007-960588","journal-title":"Endosk heute"},{"issue":"3","key":"2059_CR12","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1016\/j.clinbiomech.2010.10.008","volume":"26","author":"M Gao","year":"2011","unstructured":"Gao M, Lei W, Wu Z, Liu D, Shi L (2011) Biomechanical evaluation of fixation strength of conventional and expansive pedicle screws with or without calcium based cement augmentation. Clin Biomech (Bristol, Avon) 26(3):238\u2013244. https:\/\/doi.org\/10.1016\/j.clinbiomech.2010.10.008","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"2059_CR13","first-page":"320","volume":"22","author":"R Gazzeri","year":"2012","unstructured":"Gazzeri R, Roperto R, Fiore C (2012) Litanium expandable pedicle screw for the treatment of degenerative and traumatic spinal diseases in osteoporotic patients: preliminary experience. Surg Technol Int 22:320\u2013325","journal-title":"Surg Technol Int"},{"issue":"21","key":"2059_CR14","doi-asserted-by":"publisher","first-page":"2415","DOI":"10.1097\/00007632-199411000-00008","volume":"19","author":"TL Halvorson","year":"1994","unstructured":"Halvorson TL, Kelley LA, Thomas KA, Whitecloud TS, Cook SD (1994) Effects of bone mineral density on pedicle screw fixation. Spine (Phila Pa 1976) 19(21):2415\u20132420","journal-title":"Spine (Phila Pa 1976)"},{"key":"2059_CR15","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1016\/j.medengphy.2018.07.003","volume":"60","author":"P Heny\u0161","year":"2018","unstructured":"Heny\u0161 P, Leuridan S, Goossens Q, Mulier M, Pastrav L, Desmet W, Sloten JV, Denis K, \u010capek L (2018) Modal frequency and shape curvature as a measure of implant fixation: a computer study on the acetabular cup. Med Eng Phys 60:30\u201338. https:\/\/doi.org\/10.1016\/j.medengphy.2018.07.003","journal-title":"Med Eng Phys"},{"issue":"6","key":"2059_CR16","doi-asserted-by":"publisher","first-page":"1243","DOI":"10.1016\/j.orthres.2004.03.007","volume":"22","author":"S Inceoglu","year":"2004","unstructured":"Inceoglu S, McLain RF, Cayli S, Kilincer C, Ferrara L (2004) Stress relaxation of bone significantly affects the pull-out behavior of pedicle screws. J Orthop Res 22(6):1243\u20131247. https:\/\/doi.org\/10.1016\/j.orthres.2004.03.007","journal-title":"J Orthop Res"},{"issue":"12","key":"2059_CR17","doi-asserted-by":"publisher","first-page":"1321","DOI":"10.1097\/01.brs.0000218478.70656.63","volume":"31","author":"S Inceoglu","year":"2006","unstructured":"Inceoglu S, Akbay A, McLain RF (2006) Stress relaxation at the bone-pedicle screw interface in human bone. Spine (Phila Pa 1976) 31(12):1321\u20131326. https:\/\/doi.org\/10.1097\/01.brs.0000218478.70656.63","journal-title":"Spine (Phila Pa 1976)"},{"issue":"2","key":"2059_CR18","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s00897970111a","volume":"2","author":"GB KAUFFMAN","year":"1997","unstructured":"KAUFFMAN GB, MAYO I (1997) The story of nitinol: the serendipitous discovery of the memory metal and its applications. Chem Educ 2(2):1\u201321. https:\/\/doi.org\/10.1007\/s00897970111a","journal-title":"Chem Educ"},{"key":"2059_CR19","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1016\/j.jmbbm.2019.06.013","volume":"98","author":"B Nowak","year":"2019","unstructured":"Nowak B (2019) Experimental study on the loosening of pedicle screws implanted to synthetic bone vertebra models and under non-pull-out mechanical loads. J Mech Behav Biomed Mater 98:200\u2013204. https:\/\/doi.org\/10.1016\/j.jmbbm.2019.06.013","journal-title":"J Mech Behav Biomed Mater"},{"issue":"24","key":"2059_CR20","doi-asserted-by":"publisher","first-page":"2774","DOI":"10.1097\/00007632-199412150-00007","volume":"19","author":"A Ohlin","year":"1994","unstructured":"Ohlin A, Karlsson M, Duppe H, Hasserius R, Redlund-Johnell I (1994) Complications after transpedicular stabilization of the spine. A survivorship analysis of 163 cases. Spine (Phila Pa 1976) 19(24):2774\u20132779","journal-title":"Spine (Phila Pa 1976)"},{"issue":"2","key":"2059_CR21","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1302\/0301-620X.79B2.0790183","volume":"79","author":"H Pihlajamaki","year":"1997","unstructured":"Pihlajamaki H, Myllynen P, Bostman O (1997) Complications of transpedicular lumbosacral fixation for non-traumatic disorders. J Bone Joint Surg (Br) 79(2):183\u2013189","journal-title":"J Bone Joint Surg (Br)"},{"issue":"3","key":"2059_CR22","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1007\/s11837-017-2725-8","volume":"70","author":"T T\u00f6ppel","year":"2018","unstructured":"T\u00f6ppel T, Lausch H, Brand M, Hensel E, Arnold M, Rotsch C (2018) Structural integration of sensors\/actuators by laser beam melting for tailored smart components. JOM 70(3):321\u2013327. https:\/\/doi.org\/10.1007\/s11837-017-2725-8","journal-title":"JOM"},{"issue":"12","key":"2059_CR23","doi-asserted-by":"publisher","first-page":"2122","DOI":"10.1007\/s00586-010-1489-4","volume":"19","author":"S Wan","year":"2010","unstructured":"Wan S, Lei W, Wu Z, Liu D, Gao M, Fu S (2010) Biomechanical and histological evaluation of an expandable pedicle screw in osteoporotic spine in sheep. Eur Spine J 19(12):2122\u20132129. https:\/\/doi.org\/10.1007\/s00586-010-1489-4","journal-title":"Eur Spine J"},{"issue":"11","key":"2059_CR24","doi-asserted-by":"publisher","first-page":"2891","DOI":"10.1007\/s00586-017-5091-x","volume":"26","author":"L Weiser","year":"2017","unstructured":"Weiser L, Huber G, Sellenschloh K, Viezens L, P\u00fcschel K, Morlock MM, Lehmann W (2017) Insufficient stability of pedicle screws in osteoporotic vertebrae: biomechanical correlation of bone mineral density and pedicle screw fixation strength. Eur Spine J 26(11):2891\u20132897. https:\/\/doi.org\/10.1007\/s00586-017-5091-x","journal-title":"Eur Spine J"},{"issue":"4","key":"2059_CR25","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1007\/s00402-011-1439-6","volume":"132","author":"Z-x Wu","year":"2012","unstructured":"Wu Z-x, Gong F-t, Liu L, Ma Z-s, Zhang Y, Zhao X, Yang M, Lei W, Sang H-x (2012) A comparative study on screw loosening in osteoporotic lumbar spine fusion between expandable and conventional pedicle screws. Arch Orthop Trauma Surg 132(4):471\u2013476. https:\/\/doi.org\/10.1007\/s00402-011-1439-6","journal-title":"Arch Orthop Trauma Surg"},{"issue":"8","key":"2059_CR26","doi-asserted-by":"publisher","first-page":"1235","DOI":"10.1016\/j.dental.2018.05.016","volume":"34","author":"EM Zanetti","year":"2018","unstructured":"Zanetti EM, Ciaramella S, Cal\u00ec M, Pascoletti G, Martorelli M, Asero R, Watts DC (2018) Modal analysis for implant stability assessment: sensitivity of this methodology for different implant designs. Dent Mater 34(8):1235\u20131245. https:\/\/doi.org\/10.1016\/j.dental.2018.05.016","journal-title":"Dent Mater"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-019-02059-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11517-019-02059-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-019-02059-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,11,17]],"date-time":"2020-11-17T00:37:28Z","timestamp":1605573448000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11517-019-02059-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11,18]]},"references-count":26,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,1]]}},"alternative-id":["2059"],"URL":"https:\/\/doi.org\/10.1007\/s11517-019-02059-x","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,11,18]]},"assertion":[{"value":"24 April 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 November 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 November 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interests"}},{"value":"As part of the donation regulated by the Saxonian Death and Funeral Act of 1994, institutional approval for the use of the post-mortem tissues of human body donors was obtained from the Institute of Anatomy, University of Leipzig, Germany.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"While alive, all body donors gave their informed and written consent to the donation of their bodies for teaching and research purposes.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statement of informed consent"}}]}}