{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,16]],"date-time":"2026-04-16T18:31:23Z","timestamp":1776364283237,"version":"3.51.2"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2019,12,23]],"date-time":"2019-12-23T00:00:00Z","timestamp":1577059200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,12,23]],"date-time":"2019-12-23T00:00:00Z","timestamp":1577059200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/100015564","name":"Universit\u00e9 Franco Italienne","doi-asserted-by":"crossref","award":["C2-881 - Vinci 2018"],"award-info":[{"award-number":["C2-881 - Vinci 2018"]}],"id":[{"id":"10.13039\/100015564","id-type":"DOI","asserted-by":"crossref"}]},{"name":"F\u00e9d\u00e9ration des amput\u00e9s de guerre de France"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2020,3]]},"DOI":"10.1007\/s11517-019-02098-4","type":"journal-article","created":{"date-parts":[[2019,12,23]],"date-time":"2019-12-23T19:02:49Z","timestamp":1577127769000},"page":"461-470","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Gait event detection using inertial measurement units in people with transfemoral amputation: a comparative study"],"prefix":"10.1007","volume":"58","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7093-5096","authenticated-orcid":false,"given":"Emeline","family":"Simonetti","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Coralie","family":"Villa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joseph","family":"Bascou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giuseppe","family":"Vannozzi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elena","family":"Bergamini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H\u00e9l\u00e8ne","family":"Pillet","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,12,23]]},"reference":[{"key":"2098_CR1","doi-asserted-by":"publisher","unstructured":"Perry J (1992) Gait analysis normal and pathological function. Thorofare, NJ, Slack Incorporated. https:\/\/doi.org\/10.1097\/01241398-199211000-00023","DOI":"10.1097\/01241398-199211000-00023"},{"key":"2098_CR2","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1016\/S0966-6362(02)00066-8","volume":"17","author":"L Nolan","year":"2003","unstructured":"Nolan L, Wit A, Dudzi\u00f1ski K, Lees A, Lake M, Wychowa\u00f1ski M (2003) Adjustments in gait symmetry with walking speed in trans-femoral and trans-tibial amputees. Gait Posture 17:142\u2013151. https:\/\/doi.org\/10.1016\/S0966-6362(02)00066-8","journal-title":"Gait Posture"},{"key":"2098_CR3","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1016\/j.gaitpost.2018.05.025","volume":"64","author":"G Bastas","year":"2018","unstructured":"Bastas G, Fleck JJ, Peters RA, Zelik KE (2018) IMU-based gait analysis in lower limb prosthesis users: comparison of step demarcation algorithms. Gait Posture 64:30\u201337. https:\/\/doi.org\/10.1016\/j.gaitpost.2018.05.025","journal-title":"Gait Posture"},{"key":"2098_CR4","doi-asserted-by":"publisher","first-page":"2704","DOI":"10.1109\/TBME.2018.2813999","volume":"65","author":"E Ledoux","year":"2018","unstructured":"Ledoux E (2018) Inertial sensing for gait event detection and transfemoral prosthesis control strategy. IEEE Trans Biomed Eng 65:2704\u20132712. https:\/\/doi.org\/10.1109\/TBME.2018.2813999","journal-title":"IEEE Trans Biomed Eng"},{"key":"2098_CR5","first-page":"45","volume":"37","author":"AC AG","year":"2015","unstructured":"AG AC, Raggi M, Andreoni G, Sacchetti R (2015) Clinical gait analysis for amputees: innovation wishlist and the perspectives offered by the outwalk protocol. G Ital Med Lav Ergon 37:45\u201348","journal-title":"G Ital Med Lav Ergon"},{"key":"2098_CR6","doi-asserted-by":"publisher","first-page":"689","DOI":"10.1016\/S0021-9290(02)00008-8","volume":"35","author":"K Aminian","year":"2002","unstructured":"Aminian K, Najafi B, B\u00fcla C, Leyvraz P-F, Robert P (2002) Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes. J Biomech 35:689\u2013699. https:\/\/doi.org\/10.1016\/S0021-9290(02)00008-8","journal-title":"J Biomech"},{"key":"2098_CR7","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1016\/S0268-0033(01)00026-2","volume":"16","author":"S Barnett","year":"2001","unstructured":"Barnett S, Cunningham JLJ, West S (2001) A comparison of vertical force and temporal parameters produced by an in-shoe pressure measuring system and a force platform. Clin Biomech 16:353\u2013357. https:\/\/doi.org\/10.1016\/S0268-0033(01)00026-2","journal-title":"Clin Biomech"},{"issue":"5","key":"2098_CR8","doi-asserted-by":"publisher","first-page":"492","DOI":"10.1177\/0309364619865814","volume":"43","author":"I Loiret","year":"2019","unstructured":"Loiret I, Villa C, Dauriac B, Bonnet X, Martinet N, Paysant J, Pillet H (2019) Are wearable insoles a validated tool for quantifying transfemoral amputee gait asymmetry? Prosthetics Orthot Int 43(5):492\u2013499. https:\/\/doi.org\/10.1177\/0309364619865814","journal-title":"Prosthetics Orthot Int"},{"key":"2098_CR9","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1016\/j.gaitpost.2018.08.025","volume":"66","author":"G Pacini Panebianco","year":"2018","unstructured":"Pacini Panebianco G, Bisi MC, Stagni R, Fantozzi S (2018) Analysis of the performance of 17 algorithms from a systematic review: influence of sensor position, analysed variable and computational approach in gait timing estimation from IMU measurements. Gait Posture 66:76\u201382. https:\/\/doi.org\/10.1016\/j.gaitpost.2018.08.025","journal-title":"Gait Posture"},{"key":"2098_CR10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/S0966-6362(02)00190-X","volume":"18","author":"W Zijlstra","year":"2003","unstructured":"Zijlstra W, Hof AL (2003) Assessment of spatio-temporal gait parameters from trunk accelerations during human walking. Gait Posture 18:1\u201310. https:\/\/doi.org\/10.1016\/S0966-6362(02)00190-X","journal-title":"Gait Posture"},{"key":"2098_CR11","doi-asserted-by":"publisher","first-page":"482","DOI":"10.1016\/j.gaitpost.2005.12.006","volume":"24","author":"M Brandes","year":"2006","unstructured":"Brandes M, Zijlstra W, Heikens S, Van Lummel R, Rosenbaum D (2006) Accelerometry based assessment of gait parameters in children. Gait Posture 24:482\u2013486. https:\/\/doi.org\/10.1016\/j.gaitpost.2005.12.006","journal-title":"Gait Posture"},{"key":"2098_CR12","doi-asserted-by":"publisher","first-page":"1335","DOI":"10.1682\/JRRD.2007.12.0209","volume":"45","author":"H Houdijk","year":"2008","unstructured":"Houdijk H, Appelman FM, Van Velzen JM, Van der Woude LHV, Van Bennekom CAM (2008) Validity of DynaPort GaitMonitor for assessment of spatiotemporal parameters in amputee gait. J Rehabil Res Dev 45:1335\u20131342. https:\/\/doi.org\/10.1682\/JRRD.2007.12.0209","journal-title":"J Rehabil Res Dev"},{"key":"2098_CR13","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1016\/j.gaitpost.2009.11.014","volume":"3","author":"RC Gonz\u00e1lez","year":"2010","unstructured":"Gonz\u00e1lez RC, L\u00f3pez AM, Rodriguez-Ur\u00eda J, \u00c1lvarez D, Alvarez JC (2010) Real-time gait event detection for normal subjects from lower trunk accelerations. Gait Posture 3:322\u2013325. https:\/\/doi.org\/10.1016\/j.gaitpost.2009.11.014","journal-title":"Gait Posture"},{"key":"2098_CR14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1743-0003-9-9","volume":"9","author":"A K\u00f6se","year":"2012","unstructured":"K\u00f6se A, Cereatti A, Della Croce U (2012) Bilateral step length estimation using a single inertial measurement unit attached to the pelvis. J Neuroeng Rehabil 9:1\u201310. https:\/\/doi.org\/10.1186\/1743-0003-9-9","journal-title":"J Neuroeng Rehabil"},{"key":"2098_CR15","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1016\/j.gaitpost.2012.02.019","volume":"36","author":"J McCamley","year":"2012","unstructured":"McCamley J, Donati M, Grimpampi E, Mazz\u00e0 C (2012) An enhanced estimate of initial contact and final contact instants of time using lower trunk inertial sensor data. Gait Posture 36:316\u2013318. https:\/\/doi.org\/10.1016\/j.gaitpost.2012.02.019","journal-title":"Gait Posture"},{"key":"2098_CR16","doi-asserted-by":"publisher","unstructured":"Trojaniello D, Ravaschio A, Hausdorff JM, Cereatti A (2015) Comparative assessment of different methods for the estimation of gait temporal parameters using a single inertial sensor: application to elderly, post-stroke, Parkinson\u2019s disease and Huntington\u2019s disease subjects Gait Posture 42:310\u2013316. doi:https:\/\/doi.org\/10.1016\/j.gaitpost.2015.06.008","DOI":"10.1016\/j.gaitpost.2015.06.008"},{"key":"2098_CR17","doi-asserted-by":"publisher","first-page":"1434","DOI":"10.1109\/tbme.2004.827933","volume":"51","author":"A Salarian","year":"2004","unstructured":"Salarian A, Russmann H, Vingerhoets FJG, Dehollain C, Blanc Y, Burkhard PR, Aminian K (2004) Gait assessment in Parkinson\u2019s disease: toward an ambulatory system for long-term monitoring. IEEE Trans Biomed Eng 51:1434\u20131443. https:\/\/doi.org\/10.1109\/tbme.2004.827933","journal-title":"IEEE Trans Biomed Eng"},{"key":"2098_CR18","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1109\/TNSRE.2004.843176","volume":"13","author":"RW Selles","year":"2005","unstructured":"Selles RW, Formanoy MAG, Bussmann JBJ, Janssens PJ, Stam HJ (2005) Automated estimation of initial and terminal contact timing using accelerometers; development and validation in transtibial amputees and controls. IEEE Trans Neural Syst Rehabil Eng 13:81\u201388. https:\/\/doi.org\/10.1109\/TNSRE.2004.843176","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"2098_CR19","doi-asserted-by":"publisher","first-page":"5683","DOI":"10.3390\/s100605683","volume":"10","author":"P Catalfamo","year":"2010","unstructured":"Catalfamo P, Ghoussayni S, Ewins D (2010) Gait event detection on level ground and incline walking using a rate gyroscope. Sensors 10:5683\u20135702. https:\/\/doi.org\/10.3390\/s100605683","journal-title":"Sensors"},{"key":"2098_CR20","doi-asserted-by":"publisher","first-page":"1251","DOI":"10.1007\/s11517-010-0692-0","volume":"48","author":"BR Greene","year":"2010","unstructured":"Greene BR, McGrath D, O\u2019Neill R, O\u2019Donovan KJ, Burns A, Caulfield B (2010) An adaptive gyroscope-based algorithm for temporal gait analysis. Med Biol Eng Comput 48:1251\u20131260. https:\/\/doi.org\/10.1007\/s11517-010-0692-0","journal-title":"Med Biol Eng Comput"},{"key":"2098_CR21","doi-asserted-by":"publisher","first-page":"152","DOI":"10.1186\/1743-0003-11-152","volume":"11","author":"D Trojaniello","year":"2014","unstructured":"Trojaniello D, Cereatti A, Pelosin E, Avanzino L, Mirelman A, Hausdorff JM, Della Croce U (2014) Estimation of step-by-step spatio-temporal parameters of normal and impaired gait using shank-mounted magneto-inertial sensors: application to elderly, hemiparetic, parkinsonian and choreic gait. J Neuroeng Rehabil 11:152. https:\/\/doi.org\/10.1186\/1743-0003-11-152","journal-title":"J Neuroeng Rehabil"},{"key":"2098_CR22","doi-asserted-by":"publisher","first-page":"1500","DOI":"10.1109\/TNSRE.2016.2636367","volume":"25","author":"HF Maqbool","year":"2017","unstructured":"Maqbool HF, Husman MAB, Awad MI, Abouhossein A, Iqbal N, Dehghani-Sanij AA (2017) A real-time gait event detection for lower limb prosthesis control and evaluation. IEEE Trans neural Syst Rehabil Eng 25:1500\u20131509. https:\/\/doi.org\/10.1109\/TNSRE.2016.2636367","journal-title":"IEEE Trans neural Syst Rehabil Eng"},{"key":"2098_CR23","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1186\/s12938-018-0488-2","volume":"17","author":"M Bertoli","year":"2018","unstructured":"Bertoli M, Cereatti A, Trojaniello D, Avanzino L, Pelosin E, Del Din S et al (2018) Estimation of spatio-temporal parameters of gait from magneto-inertial measurement units: multicenter validation among Parkinson, mildly cognitively impaired and healthy older adults. Biomed Eng Online 17:58. https:\/\/doi.org\/10.1186\/s12938-018-0488-2","journal-title":"Biomed Eng Online"},{"key":"2098_CR24","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1016\/j.gaitpost.2005.12.017","volume":"24","author":"JM Jasiewicz","year":"2006","unstructured":"Jasiewicz JM, Allum JHJ, Middleton JW, Barriskill A, Condie P, Purcell B, Li RC (2006) Gait event detection using linear accelerometers or angular velocity transducers in able-bodied and spinal-cord injured individuals. Gait Posture 24:502\u2013509. https:\/\/doi.org\/10.1016\/j.gaitpost.2005.12.017","journal-title":"Gait Posture"},{"key":"2098_CR25","doi-asserted-by":"publisher","first-page":"486","DOI":"10.1109\/TBME.2004.840727","volume":"52","author":"AM Sabatini","year":"2005","unstructured":"Sabatini AM, Martelloni C, Scapellato S, Cavallo F (2005) Assessment of walking features from foot inertial sensing. IEEE Trans Biomed Eng 52:486\u2013494. https:\/\/doi.org\/10.1109\/TBME.2004.840727","journal-title":"IEEE Trans Biomed Eng"},{"key":"2098_CR26","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1016\/j.gaitpost.2012.07.012","volume":"37","author":"B Mariani","year":"2013","unstructured":"Mariani B, Rouhani H, Crevoisier X, Aminian K (2013) Quantitative estimation of foot-flat and stance phase of gait using foot-worn inertial sensors. Gait Posture 37:229\u2013234. https:\/\/doi.org\/10.1016\/j.gaitpost.2012.07.012","journal-title":"Gait Posture"},{"key":"2098_CR27","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1016\/j.gaitpost.2014.07.007","volume":"40","author":"D Trojaniello","year":"2014","unstructured":"Trojaniello D, Cereatti A, Della Croce U (2014) Accuracy, sensitivity and robustness of five different methods for the estimation of gait temporal parameters using a single inertial sensor mounted on the lower trunk. Gait Posture 40:487\u2013492. https:\/\/doi.org\/10.1016\/j.gaitpost.2014.07.007","journal-title":"Gait Posture"},{"key":"2098_CR28","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1016\/j.gaitpost.2016.08.012","volume":"50","author":"FA Storm","year":"2016","unstructured":"Storm FA, Buckley CJ, Mazz\u00e0 C (2016) Gait event detection in laboratory and real life settings: accuracy of ankle and waist sensor based methods. Gait Posture 50:42\u201346. https:\/\/doi.org\/10.1016\/j.gaitpost.2016.08.012","journal-title":"Gait Posture"},{"key":"2098_CR29","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1016\/j.apmr.2007.08.136","volume":"89","author":"H Goujon-Pillet","year":"2008","unstructured":"Goujon-Pillet H, Sapin E, Fod\u00e9 P, Lavaste F (2008) Three-dimensional motions of trunk and pelvis during transfemoral amputee gait. Arch Phys Med Rehabil 89:87\u201394. https:\/\/doi.org\/10.1016\/j.apmr.2007.08.136","journal-title":"Arch Phys Med Rehabil"},{"key":"2098_CR30","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1080\/03093640600805134","volume":"30","author":"H Goujon","year":"2006","unstructured":"Goujon H, Bonnet X, Sautreuil P, Maurisset M, Darmon L, Fode P, Lavaste F (2006) A functional evaluation of prosthetic foot kinematics during lower-limb amputee gait. Prosthetics Orthot Int 30:213\u2013223. https:\/\/doi.org\/10.1080\/03093640600805134","journal-title":"Prosthetics Orthot Int"},{"key":"2098_CR31","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1016\/j.gaitpost.2015.09.024","volume":"43","author":"JH Hollman","year":"2016","unstructured":"Hollman JH, Watkins MK, Imhoff AC, Braun CE, Akervik KA, Ness DK (2016) A comparison of variability in spatiotemporal gait parameters between treadmill and overground walking conditions. Gait Posture 43:204\u20132019. https:\/\/doi.org\/10.1016\/j.gaitpost.2015.09.024","journal-title":"Gait Posture"},{"key":"2098_CR32","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1177\/0309364618791618","volume":"43","author":"C Timmermans","year":"2019","unstructured":"Timmermans C, Cutti AG, van Donkersgoed H, Roerdink M (2019) Gaitography on lower-limb amputees: repeatability and between-methods agreement. Prosthetics Orthot Int 43:71\u201379. https:\/\/doi.org\/10.1177\/0309364618791618","journal-title":"Prosthetics Orthot Int"},{"key":"2098_CR33","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1016\/j.gaitpost.2010.01.003","volume":"31","author":"C Kendell","year":"2010","unstructured":"Kendell C, Lemaire ED, Dudek NL, Kofman J (2010) Indicators of dynamic stability in transtibial prosthesis users. Gait Posture 31:375\u2013379. https:\/\/doi.org\/10.1016\/j.gaitpost.2010.01.003","journal-title":"Gait Posture"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-019-02098-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11517-019-02098-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-019-02098-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,12,22]],"date-time":"2020-12-22T00:11:42Z","timestamp":1608595902000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11517-019-02098-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12,23]]},"references-count":33,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2020,3]]}},"alternative-id":["2098"],"URL":"https:\/\/doi.org\/10.1007\/s11517-019-02098-4","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,12,23]]},"assertion":[{"value":"20 September 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 December 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 December 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the national research committee (CPP IDF VI, No. 2014-A01938-39) and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Study sponsors did not have a role in the study design, collection, analysis and interpretation of data, writing of the manuscript or the decision to submit the manuscript for publication.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Disclaimer"}}]}}