{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T16:09:47Z","timestamp":1784822987976,"version":"3.55.0"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2020,2,19]],"date-time":"2020-02-19T00:00:00Z","timestamp":1582070400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,2,19]],"date-time":"2020-02-19T00:00:00Z","timestamp":1582070400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"name":"National Additive Manufacturing Innovation Cluster","award":["2016013"],"award-info":[{"award-number":["2016013"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2020,5]]},"DOI":"10.1007\/s11517-019-02104-9","type":"journal-article","created":{"date-parts":[[2020,2,19]],"date-time":"2020-02-19T13:03:20Z","timestamp":1582117400000},"page":"921-931","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":49,"title":["Finite element analysis of bone and implant stresses for customized 3D-printed orthopaedic implants in fracture fixation"],"prefix":"10.1007","volume":"58","author":[{"given":"Lina","family":"Yan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joel Louis","family":"Lim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun Wei","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Clement Shi Hao","family":"Tia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7516-2907","authenticated-orcid":false,"given":"Gavin Kane","family":"O\u2019Neill","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Desmond Y.R.","family":"Chong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,2,19]]},"reference":[{"key":"2104_CR1","unstructured":"Sniderman B, Mahto M, Cotteleer MJ (2016) Industry 4.0 and manufacturing ecosystems. In: Deloitte University Press. https:\/\/www2.deloitte.com\/content\/dam\/insights\/us\/articles\/manufacturing-ecosystems-exploring-world-connected-enterprises\/DUP_2898_Industry4.0ManufacturingEcosystems.pdf"},{"key":"2104_CR2","unstructured":"Davies R (2015) Industry 4.0 digitalisation for productivity and growth. In: European Parliamentary Research Service Briefing September 2015. http:\/\/www.europarl.europa.eu\/RegData\/etudes\/BRIE\/2015\/568337\/EPRS_BRI(2015)568337_EN.pdf"},{"key":"2104_CR3","unstructured":"Gerbert P, Lorenz M, R\u00fc\u03b2mann M, Waldner M, Justus J, Engel P, Harnisch M (2015) Industry 4.0: the future of productivity and growth in manufacturing industries Boston Consulting Group. https:\/\/www.bcg.com\/publications\/2015\/engineered_products_project_business_industry_4_future_productivity_growth_manufacturing_industries.aspx"},{"key":"2104_CR4","unstructured":"3D Printing of Medical Devices. U.S. Food and Drug Administration. https:\/\/www.fda.gov\/medicaldevices\/productsandmedicalprocedures\/3dprintingofmedicaldevices\/default.htm"},{"issue":"3","key":"2104_CR5","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1016\/j.injury.2006.10.024","volume":"38","author":"E Hasenboehler","year":"2007","unstructured":"Hasenboehler E, Rikli D, Babst R (2007) Locking compression plate with minimally invasive plate osteosynthesis in diaphyseal and distal tibia fracture: a retrospective study of 32 patients. Injury 38(3):365\u2013370","journal-title":"Injury"},{"key":"2104_CR6","doi-asserted-by":"crossref","unstructured":"Wagner M (2003) General principles for the clinical use of the LCP. Injury 34:31\u201342","DOI":"10.1016\/j.injury.2003.09.023"},{"key":"2104_CR7","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1097\/00003086-199201000-00014","volume":"274","author":"R Huiskes","year":"1992","unstructured":"Huiskes R, Weinans H, Van Rietbergen B (1992) The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials. Clin Orthop Relat Res 274:124\u2013134","journal-title":"Clin Orthop Relat Res"},{"issue":"2","key":"2104_CR8","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1055\/s-0035-1570114","volume":"29","author":"FM Pfeiffer","year":"2016","unstructured":"Pfeiffer FM (2016) The use of finite element analysis to enhance research and clinical practice in orthopaedics. J Knee Surg 29(2):149\u2013158","journal-title":"J Knee Surg"},{"issue":"5","key":"2104_CR9","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1016\/1350-4533(95)97314-F","volume":"17","author":"JY Rho","year":"1995","unstructured":"Rho JY, Hobatho M, Ashman RB (1995) Relations of mechanical properties to density and CT numbers in human bone. Med Eng Phys 17(5):347\u2013355","journal-title":"Med Eng Phys"},{"issue":"4","key":"2104_CR10","first-page":"667","volume":"55","author":"M Losertov\u00e1","year":"2016","unstructured":"Losertov\u00e1 M, \u0160tamborsk\u00e1 M, Lapin J, Mare\u0161 V (2016) Comparison of deformation behavior of 316L stainless steel and Ti6Al4V alloy applied in traumatology. Metalurgija 55(4):667\u2013670","journal-title":"Metalurgija"},{"key":"2104_CR11","first-page":"30","volume":"5-6","author":"B Gervais","year":"2016","unstructured":"Gervais B, Vadean A, Raison M, Brochu M (2016) Failure analysis of a 316L stainless steel femoral orthopaedic implant. Eng Fail Anal 5-6:30\u201338","journal-title":"Eng Fail Anal"},{"key":"2104_CR12","doi-asserted-by":"crossref","unstructured":"Mohammad KA, Ali A, Sahari BB, Abdullah S (2012) Fatigue behavior of austenitic type 316L stainless steel. In: IOP conference series: materials science and engineering. IOP Publishing","DOI":"10.1088\/1757-899X\/36\/1\/012012"},{"issue":"2","key":"2104_CR13","doi-asserted-by":"publisher","first-page":"409","DOI":"10.2320\/matertrans.47.409","volume":"47","author":"JY Huang","year":"2006","unstructured":"Huang JY, Yeh JJ, Jeng SL, Chen CY, Kuo RC (2006) High-cycle fatigue behavior of type 316L stainless steel. Mater Trans 47(2):409\u2013417","journal-title":"Mater Trans"},{"issue":"3","key":"2104_CR14","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1016\/S0020-1383(80)80044-1","volume":"11","author":"H Brunner","year":"1980","unstructured":"Brunner H, Simpson JP (1980) Fatigue fracture of bone plates. Injury 11(3):203\u2013207","journal-title":"Injury"},{"issue":"5","key":"2104_CR15","first-page":"448","volume":"91","author":"TP R\u00fcedi","year":"2007","unstructured":"R\u00fcedi TP, Buckley R, Moran CG (2007) AO principles of fracture management. Ann R Coll Surg Engl 91(5):448\u2013449","journal-title":"Ann R Coll Surg Engl"},{"issue":"1","key":"2104_CR16","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1186\/s12938-016-0236-4","volume":"15","author":"P Tack","year":"2016","unstructured":"Tack P, Victor J, Gemmel P, Annemans L (2016) 3D-printing techniques in a medical setting: a systematic literature review. Biomed Eng Online 15(1):115","journal-title":"Biomed Eng Online"},{"issue":"6","key":"2104_CR17","doi-asserted-by":"publisher","first-page":"1217","DOI":"10.1016\/j.injury.2017.03.005","volume":"48","author":"R Wenger","year":"2017","unstructured":"Wenger R, Oehme F, Winkler J, Perren SM, Babst R, Beeres FJP (2017) Absolute or relative stability in minimal invasive plate osteosynthesis of simple distal meta or diaphyseal tibia fractures? Injury 48(6):1217\u20131223. https:\/\/doi.org\/10.1016\/j.injury.2017.03.005","journal-title":"Injury"},{"key":"2104_CR18","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-642-67138-8","volume-title":"Biomechanics of the locomotor apparatus","author":"F Pauwels","year":"1980","unstructured":"Pauwels F (1980) Biomechanics of the locomotor apparatus, 1st edn. Springer-Verlag, Berlin Heidelberg New York","edition":"1"},{"issue":"Suppl 2","key":"2104_CR19","doi-asserted-by":"publisher","first-page":"S-B37","DOI":"10.1016\/S0020-1383(00)80042-X","volume":"31","author":"K Stoffel","year":"2000","unstructured":"Stoffel K, Klaue K, Perren SM (2000) Functional load of plates in fracture fixation in vivo and its correlate in bone healing. Injury 31(Suppl 2):S-B37\u2013S-B50","journal-title":"Injury"},{"key":"2104_CR20","doi-asserted-by":"publisher","first-page":"1246","DOI":"10.1016\/j.engfailanal.2010.02.003","volume":"17","author":"SSM Tavares","year":"2010","unstructured":"Tavares SSM, Mainier FB, Zimmerman F, Freitas R, Ajus CMI (2010) Characterization of prematurely failed stainless steel orthopaedic implants. Eng Fail Anal 17:1246\u20131253","journal-title":"Eng Fail Anal"},{"key":"2104_CR21","doi-asserted-by":"publisher","first-page":"621","DOI":"10.1016\/S1350-6307(02)00026-2","volume":"9","author":"CRF Azevedo","year":"2002","unstructured":"Azevedo CRF, Hippert E Jr (2002) Failure analysis of surgical implants in Brazil. Eng Fail Anal 9:621\u2013633","journal-title":"Eng Fail Anal"},{"key":"2104_CR22","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1016\/j.jmbbm.2014.06.011","volume":"38","author":"JB Marcomini","year":"2014","unstructured":"Marcomini JB, Baptista CARP, Pascon JP, Teixeira RL, Reis FP (2014) Investigation of a fatigue failure in a stainless steel femoral plate. J Mech Behav Biomed Mater 38:52\u201358","journal-title":"J Mech Behav Biomed Mater"},{"issue":"2","key":"2104_CR23","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/0021-9290(93)90042-D","volume":"26","author":"JY Rho","year":"1993","unstructured":"Rho JY, Ashman RB, Turner CH (1993) Young\u2019s modulus of trabecular and cortical bone material: ultrasonic and microtensile measurements. J Biomech 26(2):111\u2013119","journal-title":"J Biomech"},{"key":"2104_CR24","doi-asserted-by":"crossref","unstructured":"Mav\u010di\u010d B, Antoli\u010d V (2012) Optimal mechanical environment of the healing bone fracture\/osteotomy. Int Orthop 36:689\u2013695","DOI":"10.1007\/s00264-012-1487-8"},{"issue":"27","key":"2104_CR25","doi-asserted-by":"publisher","first-page":"1137","DOI":"10.1098\/rsif.2008.0151","volume":"5","author":"M Navarro","year":"2008","unstructured":"Navarro M, Michiardi A, Casta\u00f1o O, Planell J (2008) Biomaterials in orthopaedics. J R. Soc Interface 5(27):1137\u20131158. https:\/\/doi.org\/10.1098\/rsif.2008.0151","journal-title":"J R. Soc Interface"},{"key":"2104_CR26","doi-asserted-by":"crossref","unstructured":"Santorinaios M, Brooks W, Sutcliffe CJ, Mines RAW (2006) Crush behaviour of open cellular lattice structures manufactured using selective laser melting. WIT TRANS BUILT ENV 85:481\u2013490","DOI":"10.2495\/HPSM06047"},{"key":"2104_CR27","doi-asserted-by":"publisher","first-page":"1536","DOI":"10.1016\/j.actbio.2008.03.013","volume":"4","author":"P Heinl","year":"2008","unstructured":"Heinl P, M\u00fcller L, K\u00f6rner C, Singer RF, M\u00fcller FA (2008) Cellular Ti-6Al-4V structures with interconnected macro porosity for bone implants fabricated by selective electron beam melting. Acta Biomater 4:1536\u20131544","journal-title":"Acta Biomater"},{"key":"2104_CR28","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1016\/j.phpro.2012.10.063","volume":"39","author":"G Reinhart","year":"2012","unstructured":"Reinhart G, Teufelhart S, Riss F (2012) Investigation of the geometry-dependent anisotropic material behaviour of filigree struts in ALM-produced lattice structure. Phys Procedia 39:471\u2013479","journal-title":"Phys Procedia"},{"key":"2104_CR29","doi-asserted-by":"publisher","first-page":"648","DOI":"10.1179\/1743284715Y.0000000084","volume":"32","author":"Y Tang","year":"2016","unstructured":"Tang Y, Zhou Y, Hoff T, Garon M, Zhao YF (2016) Elastic modulus of 316 stainless steel lattice structure fabricated via binder jetting process. Mater Sci Technol 32:648\u2013656","journal-title":"Mater Sci Technol"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-019-02104-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11517-019-02104-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-019-02104-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,16]],"date-time":"2022-10-16T00:25:30Z","timestamp":1665879930000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11517-019-02104-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2,19]]},"references-count":29,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2020,5]]}},"alternative-id":["2104"],"URL":"https:\/\/doi.org\/10.1007\/s11517-019-02104-9","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,2,19]]},"assertion":[{"value":"23 July 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 December 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 February 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that there is no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}