{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T13:16:06Z","timestamp":1740143766429,"version":"3.37.3"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2020,1,23]],"date-time":"2020-01-23T00:00:00Z","timestamp":1579737600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,1,23]],"date-time":"2020-01-23T00:00:00Z","timestamp":1579737600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["1R01NS101043-01"],"award-info":[{"award-number":["1R01NS101043-01"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000005","name":"U.S. Department of Defense","doi-asserted-by":"publisher","award":["W81XWH-17-1-0240"],"award-info":[{"award-number":["W81XWH-17-1-0240"]}],"id":[{"id":"10.13039\/100000005","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2020,4]]},"DOI":"10.1007\/s11517-020-02120-0","type":"journal-article","created":{"date-parts":[[2020,1,23]],"date-time":"2020-01-23T07:03:08Z","timestamp":1579762988000},"page":"739-751","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Estimating total maximum isometric force output of trunk and hip muscles after spinal cord injury"],"prefix":"10.1007","volume":"58","author":[{"given":"Akhil","family":"Bheemreddy","sequence":"first","affiliation":[]},{"given":"Aidan","family":"Friederich","sequence":"additional","affiliation":[]},{"given":"Lisa","family":"Lombardo","sequence":"additional","affiliation":[]},{"given":"Ronald J.","family":"Triolo","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5737-1708","authenticated-orcid":false,"given":"Musa L.","family":"Audu","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2020,1,23]]},"reference":[{"issue":"10","key":"2120_CR1","doi-asserted-by":"publisher","first-page":"1371","DOI":"10.1089\/neu.2004.21.1371","volume":"21","author":"KD Anderson","year":"2004","unstructured":"Anderson KD (2004) Targeting recovery: priorities of the spinal cord-injured population. J Neurotrauma 21(10):1371\u20131383","journal-title":"J Neurotrauma"},{"issue":"3","key":"2120_CR2","doi-asserted-by":"publisher","first-page":"347","DOI":"10.3346\/jkms.2001.16.3.347","volume":"16","author":"ES Park","year":"2001","unstructured":"Park ES, Park CI, Lee HJ, Cho YS (2001) The effect of electrical stimulation on the trunk control in young children with spastic diplegic cerebral palsy. J Korean Med Sci 16(3):347\u2013350","journal-title":"J Korean Med Sci"},{"issue":"2","key":"2120_CR3","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1016\/j.apmr.2008.07.029","volume":"90","author":"RJ Triolo","year":"2009","unstructured":"Triolo RJ, Boggs L, Miller ME, Nemunaitis G, Nagy J, Bailey SN (2009) Implanted electrical stimulation of the trunk for seated postural stability and function after cervical spinal cord injury: a single case study. Arch Phys Med Rehabil 90(2):340\u2013347","journal-title":"Arch Phys Med Rehabil"},{"issue":"12","key":"2120_CR4","doi-asserted-by":"publisher","first-page":"1247","DOI":"10.1016\/j.conengprac.2012.06.007","volume":"20","author":"M Vanoncini","year":"2012","unstructured":"Vanoncini M, Holderbaum W, Andrews BJ (2012) Electrical stimulation for trunk control in paraplegia: a feasibility study. Control Eng Pract 20(12):1247\u20131258","journal-title":"Control Eng Pract"},{"key":"2120_CR5","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1016\/j.piutam.2011.04.021","volume":"2","author":"A Seth","year":"2011","unstructured":"Seth A, Sherman M, Reinbolt JA, Delp SL (2011) OpenSim: a musculoskeletal modeling and simulation framework for in silico investigations and exchange. Procedia IUTAM 2:212\u2013232","journal-title":"Procedia IUTAM"},{"issue":"11","key":"2120_CR6","doi-asserted-by":"publisher","first-page":"2055","DOI":"10.1016\/j.jbiomech.2005.06.005","volume":"39","author":"CY Scovil","year":"2006","unstructured":"Scovil CY, Ronsky JL (2006) Sensitivity of a Hill-based muscle model to perturbations in model parameters. J Biomech 39(11):2055\u20132063","journal-title":"J Biomech"},{"issue":"4","key":"2120_CR7","doi-asserted-by":"publisher","first-page":"398","DOI":"10.1109\/TNSRE.2004.836778","volume":"12","author":"M Gf\u00f6hler","year":"2004","unstructured":"Gf\u00f6hler M, Lugner P (2004) Dynamic simulation of FES cycling: influence of individual parameters. IEEE Trans Neural Syst Rehabil Eng 12(4):398\u2013405","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"2120_CR8","doi-asserted-by":"publisher","first-page":"865","DOI":"10.1152\/jappl.2001.90.3.865","volume":"90","author":"CN Maganaris","year":"2001","unstructured":"Maganaris CN, Baltzopoulos V, Ball D, Sargeant AJ (2001) In vivo specific tension of human skeletal muscle. J Appl Physiol 90:865\u2013872","journal-title":"J Appl Physiol"},{"issue":"1","key":"2120_CR9","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1016\/0021-9290(90)90373-B","volume":"23","author":"JA Friedrich","year":"1990","unstructured":"Friedrich JA, Brand RA (1990) Muscle fiber architecture in the human lower limb. J Biomechanics 23(1):91\u201395","journal-title":"J Biomechanics"},{"key":"2120_CR10","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1016\/S0021-9290(00)00202-5","volume":"34","author":"SL Delp","year":"2001","unstructured":"Delp SL, Suryanarayana S, Murray WM, Uhir J, Triolo RJ (2001) Architecture of the rectus abdominis, quadratus lumborum, and erector spinae. J Biomech 34:371\u2013375","journal-title":"J Biomech"},{"issue":"2","key":"2120_CR11","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1097\/00007632-198902000-00007","volume":"14","author":"MF Tracy","year":"1989","unstructured":"Tracy MF, Gibson MJ, Szypryt EP, Rutherford A, Corlett EN (1989) The geometry of the muscles of the lumbar spine determined by magnetic resonance imaging. Spine 14(2):186\u2013193","journal-title":"Spine"},{"key":"2120_CR12","first-page":"26","volume":"26","author":"M Ikai","year":"1968","unstructured":"Ikai M, Fukunaga T (1968) Calculation of muscle strength per unit cross-sectional area of human muscle by means of ultrasonic measurement. Int Z Angew Physiol Einschl Arbeitsphysiol 26:26\u201332","journal-title":"Int Z Angew Physiol Einschl Arbeitsphysiol"},{"issue":"1","key":"2120_CR13","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1682\/JRRD.2005.11.0172","volume":"44","author":"SA Sisto","year":"2007","unstructured":"Sisto SA, Dyson-Hudson T (2007) Dynamometry testing in spinal cord injury. J Rehabil Res Dev 44(1):123\u2013136","journal-title":"J Rehabil Res Dev"},{"key":"2120_CR14","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1114\/1.1540105","volume":"31","author":"BA Garner","year":"2003","unstructured":"Garner BA, Pandy MG (2003) Estimation of musculotendon properties in the human upper limb. Ann Biomed Eng 31:207\u2013220","journal-title":"Ann Biomed Eng"},{"issue":"14","key":"2120_CR15","doi-asserted-by":"publisher","first-page":"3459","DOI":"10.1016\/j.jbiomech.2014.09.013","volume":"47","author":"MM Morrow","year":"2014","unstructured":"Morrow MM, Rankin JW, Neptune RR, Kaufman KR (2014) A comparison of static and dynamic optimization muscle force predictions during wheelchair propulsion. J Biomech 47(14):3459\u20133465","journal-title":"J Biomech"},{"key":"2120_CR16","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1016\/S0021-9290(00)00155-X","volume":"34","author":"FC Anderson","year":"2001","unstructured":"Anderson FC, Pandy MG (2001) Static and dynamic optimization solutions for gait are practically equivalent. J Biomech 34:153\u2013161","journal-title":"J Biomech"},{"issue":"1","key":"2120_CR17","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1109\/86.296347","volume":"2","author":"R Kobetic","year":"1994","unstructured":"Kobetic R, Marsolais EB, Miller PC (1994) Function and strength of electrically stimulated hip flexor muscles in paraplegia. IEEE Transactions of Rehabilitation Engineering 2(1):11\u201317","journal-title":"IEEE Transactions of Rehabilitation Engineering"},{"issue":"2","key":"2120_CR18","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1682\/JRRD.2005.04.0072","volume":"43","author":"BP Heilman","year":"2006","unstructured":"Heilman BP, Audu ML, Kirsch RF, Triolo RJ (2006) Selection of an optimal muscle set for a 16-channel standing neuroprosthesis using a human musculoskeletal model. J Rehabil Res Dev 43(2):273\u2013286","journal-title":"J Rehabil Res Dev"},{"issue":"7","key":"2120_CR19","doi-asserted-by":"publisher","first-page":"1007","DOI":"10.1682\/JRRD.2007.10.0164","volume":"45","author":"SJ Gartman","year":"2008","unstructured":"Gartman SJ, Audu ML, Kirsh RF, Triolo RJ (2008) Selection of optimal muscle set for 16-channel standing neuroprosthesis. J Rehabil Res Dev 45(7):1007\u20131017","journal-title":"J Rehabil Res Dev"},{"key":"2120_CR20","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1682\/JRRD.2007.08.0115","volume":"46","author":"JM Lambrecht","year":"2009","unstructured":"Lambrecht JM, Audu ML, Triolo RJ, Kirsch RF (2009) Musculoskeletal model of trunk and hips for development of seated posture-control neuroprosthesis. J Rehabil Res Dev 46:515\u2013528","journal-title":"J Rehabil Res Dev"},{"key":"2120_CR21","first-page":"109","volume-title":"A modular external control unit for functional electrical stimulation. In: Proceedings of the 6th Annual Conference of the International Functional Electrical Stimulation Society","author":"SC Trier","year":"2001","unstructured":"Trier SC, Buckett JR, Campean A, Miller ME, Montague FW, Vrabec TL, Weisgarber JA (2001) A modular external control unit for functional electrical stimulation. In: Proceedings of the 6th Annual Conference of the International Functional Electrical Stimulation Society. International Functional Electrical Stimulation Society, Cleveland, p 109"},{"key":"2120_CR22","unstructured":"(2007) xPC target selecting hardware guide. The MathWorks Inc. Available via Mathworks. https:\/\/www.mathworks.com\/tagteam\/37937_xpc_target_selecting_hardware_guide.pdf"},{"issue":"5","key":"2120_CR23","doi-asserted-by":"publisher","first-page":"747","DOI":"10.1682\/JRRD.2013.09.0200","volume":"51","author":"JO Murphy","year":"2014","unstructured":"Murphy JO, Audu ML, Lombardo LM, Foglyano KM, Triolo RJ (2014) Feasibility of closed-loop controller for righting seated posture after spinal cord injury. J Rehabil Res Dev 51(5):747\u2013760","journal-title":"J Rehabil Res Dev"},{"key":"2120_CR24","unstructured":"(1988) Military male aviators. In: Anthropometry and mass distribution for human analogues. Naval Biodynamics Laboratory. Available via Humanics. https:\/\/www.humanics-es.com\/ADA304353.pdf"},{"issue":"9","key":"2120_CR25","doi-asserted-by":"publisher","first-page":"1223","DOI":"10.1016\/0021-9290(95)00178-6","volume":"29","author":"P De Leva","year":"1996","unstructured":"De Leva P (1996) Adjustments to Zatsiorsky-Seluyanov\u2019s segment inertia parameters. J Biomech 29(9):1223\u20131230","journal-title":"J Biomech"},{"issue":"5","key":"2120_CR26","first-page":"533","volume":"38","author":"RJ Triolo","year":"2001","unstructured":"Triolo RJ, Liu MQ, Kobetic R, Uhlir J (2001) Selectivity of intramuscular electrodes in the lower limbs. J Rehabil Res Dev 38(5):533\u2013544","journal-title":"J Rehabil Res Dev"},{"key":"2120_CR27","volume-title":"The head, neck, and trunk: muscles and motor points","author":"DP Quiring","year":"1967","unstructured":"Quiring DP, Warfel JH (1967) The head, neck, and trunk: muscles and motor points, 3rd edn. Lea & Febiger, Philadelphia","edition":"3"},{"key":"2120_CR28","doi-asserted-by":"publisher","first-page":"5","DOI":"10.7243\/2055-2386-3-5","volume":"3","author":"M Vazirian","year":"2016","unstructured":"Vazirian M, Van Dillen L, Bazrgari B (2016) Lumbopelvic rhythm during trunk motion in the sagittal plane: a review of the kinematic measurement methods and characterization approaches. Phys Ther Rehabil 3:5","journal-title":"Phys Ther Rehabil"},{"key":"2120_CR29","first-page":"423","volume-title":"Hard facts about soft machines: the ergonomics of seating","author":"H Serber","year":"1994","unstructured":"Serber H (1994) The study of lumbar motion in seating. In: Lueder R, Noro K (eds) Hard facts about soft machines: the ergonomics of seating. Taylor & Francis, Pennsylvania, pp 423\u2013431"},{"key":"2120_CR30","doi-asserted-by":"crossref","unstructured":"Eddy J, Lewis K (2001) Effective generation of Pareto sets using genetic programming. In: Proceedings of ASME Design Engineering Technical Conference. American Society of Mechanical Engineers, New York","DOI":"10.1115\/DETC2001\/DAC-21094"},{"key":"2120_CR31","unstructured":"Adams, B.M., Bauman, L.E., Bohnhoff, W.J., Dalbey, K.R., Ebeida, M.S., Eddy, J.P., Eldred, M.S., Hough, P.D., Hu, K.T., Jakeman, J.D., Stephens, J.A., Swiler, L.P., Vigil, D.M., and Wildey, T.M., DAKOTA, A. Multilevel parallel object-oriented framework for design optimization, parameter estimation, uncertainty quantification, and sensitivity analysis: version 6.8 user\u2019s manual, May 2018"},{"issue":"2","key":"2120_CR32","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1682\/JRRD.2005.06.0101","volume":"43","author":"AJ Wilkenfeld","year":"2006","unstructured":"Wilkenfeld AJ, Audu ML, Triolo RJ (2006) Feasibility of functional electrical stimulation for control of seated posture after spinal cord injury: a simulation study. J Rehabil Res Dev 43(2):139\u2013152","journal-title":"J Rehabil Res Dev"},{"issue":"8","key":"2120_CR33","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1016\/0021-9290(86)90164-8","volume":"19","author":"RA Brand","year":"1986","unstructured":"Brand RA, Pedersen DR, Friederich JA (1986) The sensitivity of muscle force predictions to changes in physiologic cross-sectional area. J Biomech 19(8):589\u2013596","journal-title":"J Biomech"},{"issue":"1","key":"2120_CR34","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1002\/jor.23630","volume":"36","author":"KA Burkhart","year":"2018","unstructured":"Burkhart KA, Bruno AG, Bouxsein ML, Bean JF, Anderson DE (2018) Estimating apparent maximum muscle stress of trunk extensor muscles in older adults using subject-specific musculoskeletal models. J Orthop Res 36(1):498\u2013505","journal-title":"J Orthop Res"},{"issue":"11","key":"2120_CR35","doi-asserted-by":"publisher","first-page":"e112625","DOI":"10.1371\/journal.pone.0112625","volume":"9","author":"G Valente","year":"2014","unstructured":"Valente G, Pitto L, Testi D, Seth A, Delp SL, Stagni R, Viceconti M, Taddei F (2014) Are subject-specific musculoskeletal models robust to the uncertainties in parameter identification? PLoS One 9(11):e112625","journal-title":"PLoS One"},{"key":"2120_CR36","series-title":"Advances in intelligent systems and computing","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1007\/978-3-319-08156-4_41","volume-title":"Proceedings of the Fifth International Conference on Innovations in Bio-Inspired Computing and Applications IBICA 2014","author":"J Nowakov\u00e1","year":"2014","unstructured":"Nowakov\u00e1 J, Pokorn\u00fd M (2014) System identification using genetic algorithms. In: K\u00f6mer P, Abraham A, Sn\u00e1\u0161el V (eds) Proceedings of the Fifth International Conference on Innovations in Bio-Inspired Computing and Applications IBICA 2014, Advances in intelligent systems and computing, vol 303. Springer, Cham, pp 413\u2013418"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-020-02120-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11517-020-02120-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-020-02120-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,25]],"date-time":"2023-09-25T14:32:23Z","timestamp":1695652343000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11517-020-02120-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1,23]]},"references-count":36,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2020,4]]}},"alternative-id":["2120"],"URL":"https:\/\/doi.org\/10.1007\/s11517-020-02120-0","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"type":"print","value":"0140-0118"},{"type":"electronic","value":"1741-0444"}],"subject":[],"published":{"date-parts":[[2020,1,23]]},"assertion":[{"value":"16 July 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 January 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 January 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee (Louis Stokes Cleveland Veterans Affairs Medical Center IRB #07101-H36) and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"All authors declare no competing interests in this work.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}