{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T04:27:57Z","timestamp":1777436877064,"version":"3.51.4"},"reference-count":57,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2020,4,11]],"date-time":"2020-04-11T00:00:00Z","timestamp":1586563200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,4,11]],"date-time":"2020-04-11T00:00:00Z","timestamp":1586563200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001834","name":"University of Twente","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100001834","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2020,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Despite all the efforts to optimize the meniscus prosthesis system (geometry, material, and fixation type), the success of the prosthesis in clinical practice will depend on surgical factors such as intra-operative positioning of the prosthesis. In this study, the aim was therefore to assess the implications of positional changes of the medial meniscus prosthesis for knee biomechanics. A detailed validated finite element (FE) model of human intact and meniscal implanted knees was developed based on a series of in vitro experiments. Different non-anatomical prosthesis positions were applied in the FE model, and the biomechanical response during the gait stance phase compared with an anatomically positioned prosthesis, as well as meniscectomized and also the intact knee model. The results showed that an anatomical positioning of the medial meniscus prosthesis could better recover the intact knee biomechanics, while a non-anatomical positioning of the prosthesis to a limited extent alters the knee kinematics and articular contact pressure and increases the implantation failure risk. The outcomes indicate that a medial or anterior positioning of the meniscus prosthesis may be more forgiving than a posteriorly or laterally positioned prosthesis. The outcome of this study may provide a better insight into the possible consequences of meniscus prosthesis positioning errors for the patient and the prosthesis functionality.<\/jats:p>","DOI":"10.1007\/s11517-020-02158-0","type":"journal-article","created":{"date-parts":[[2020,4,11]],"date-time":"2020-04-11T19:02:26Z","timestamp":1586631746000},"page":"1341-1355","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["The implications of non-anatomical positioning of a meniscus prosthesis on predicted human knee joint biomechanics"],"prefix":"10.1007","volume":"58","author":[{"given":"Hamid","family":"Naghibi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dennis","family":"Janssen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ton","family":"van den Boogaard","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tony","family":"van Tienen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nico","family":"Verdonschot","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,4,11]]},"reference":[{"issue":"6","key":"2158_CR1","doi-asserted-by":"crossref","first-page":"1763","DOI":"10.1007\/s00167-016-4069-2","volume":"24","author":"R Verdonk","year":"2016","unstructured":"Verdonk R, Madry H, Shabshin N, Dirisamer F, Angele P (2016) The role of meniscal tissue in joint protection in early osteoarthritis. Knee Surg Sport Traumatol Arthrosc 24(6):1763\u20131774","journal-title":"Knee Surg Sport Traumatol Arthrosc"},{"issue":"2","key":"2158_CR2","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1097\/JSA.0b013e318246f005","volume":"20","author":"AS Lee","year":"2012","unstructured":"Lee AS, Kang RW, Kroin E, Verma NN, Cole BJ (2012) Allograft meniscus transplantation. Sports Med Arthrosc 20(2):106\u2013114","journal-title":"Sports Med Arthrosc"},{"issue":"6","key":"2158_CR3","doi-asserted-by":"crossref","first-page":"1384","DOI":"10.1177\/0363546512442341","volume":"40","author":"B Lee","year":"2012","unstructured":"Lee B, Chung J, Kim J, Cho W, Kim K, Bin S (2012) Morphologic changes in fresh-frozen meniscus allografts over 1 year a prospective magnetic resonance imaging study on the width and thickness of transplants. Am J Sports Med 40(6):1384\u20131391","journal-title":"Am J Sports Med"},{"issue":"3","key":"2158_CR4","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1016\/S0749-8063(98)70140-9","volume":"14","author":"Y Wada","year":"1998","unstructured":"Wada Y, Amiel M, Harwood F, Oriya H, Amiel D (1998) Architectural remodeling in deep frozen meniscal allografts after total meniscectomy. J Arthrosc Relat Surg 14(3):250\u2013257","journal-title":"J Arthrosc Relat Surg"},{"issue":"7","key":"2158_CR5","doi-asserted-by":"crossref","first-page":"728","DOI":"10.1016\/S0749-8063(04)00600-0","volume":"20","author":"PC Rijk","year":"2007","unstructured":"Rijk PC (2007) Meniscal allograft transplantation\u2014part I: background, results, graft selection and preservation, and surgical considerations. J Arthrosc Relat Surg 20(7):728\u2013743","journal-title":"J Arthrosc Relat Surg"},{"issue":"5","key":"2158_CR6","doi-asserted-by":"crossref","first-page":"927","DOI":"10.1016\/j.arthro.2014.11.019","volume":"31","author":"RJ Warth","year":"2015","unstructured":"Warth RJ, Rodkey WG (2015) Resorbable collagen scaffolds for the treatment of meniscus defects: a systematic review. Arthrosc J Arthrosc Relat Surg 31(5):927\u2013941","journal-title":"Arthrosc J Arthrosc Relat Surg"},{"issue":"1","key":"2158_CR7","doi-asserted-by":"crossref","first-page":"3","DOI":"10.5792\/ksrr.16.059","volume":"29","author":"S Dangelmajer","year":"2017","unstructured":"Dangelmajer S, Familiari F, Simonetta R, Kaymakoglu M, Huri G (2017) Meniscal transplants and scaffolds: a systematic review of the literature. Knee Surg Relat Res 29(1):3\u201310","journal-title":"Knee Surg Relat Res"},{"issue":"2","key":"2158_CR8","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1007\/s00264-012-1682-7","volume":"37","author":"ACT Vrancken","year":"2013","unstructured":"Vrancken ACT, Buma P, Van Tienen TG (2013) Synthetic meniscus replacement: a review. Int Orthop 37(2):291\u2013299","journal-title":"Int Orthop"},{"key":"2158_CR9","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1115\/1.1503061","volume":"124","author":"A Huang","year":"2002","unstructured":"Huang A, Hull ML, Howell SM, Donahue TH (2002) Identification of cross-sectional parameters of lateral meniscal allografts that predict tibial contact pressure in human cadaveric knees. J Biomech Eng 124:481\u2013489","journal-title":"J Biomech Eng"},{"issue":"4","key":"2158_CR10","doi-asserted-by":"crossref","first-page":"807","DOI":"10.1016\/j.orthres.2003.12.010","volume":"22","author":"TLH Donahue","year":"2004","unstructured":"Donahue TLH, Hull ML, Rashid MM, Jacobs CR (2004) The sensitivity of tibiofemoral contact pressure to the size and shape of the lateral and medial menisci. J Orthop Res 22(4):807\u2013814","journal-title":"J Orthop Res"},{"key":"2158_CR11","doi-asserted-by":"crossref","unstructured":"Mcdermott ID, Sharifi F, Bull AMJ, Gupte CM, Thomas RW, and Amis AA (2004) An anatomical study of meniscal allograft sizing, pp 130\u2013135","DOI":"10.1007\/s00167-003-0366-7"},{"issue":"1","key":"2158_CR12","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/S0968-0160(02)00106-0","volume":"10","author":"JR Meakin","year":"2003","unstructured":"Meakin JR, Shrive NG, Frank CB, Hart DA (2003) Finite element analysis of the meniscus: the influence of geometry and material properties on its behaviour. Knee 10(1):33\u201341","journal-title":"Knee"},{"key":"2158_CR13","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1016\/0268-0033(92)90022-V","volume":"7","author":"K Sommerlath","year":"1992","unstructured":"Sommerlath K, Gallino M, Gillquist J (1992) Biomechanical characteristics of different artificial substitutes for rabbit medial meniscus and effect of prosthesis size on knee cartilage. Clin Biomech 7:97\u2013103","journal-title":"Clin Biomech"},{"key":"2158_CR14","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1115\/1.4000407","volume":"132","author":"E Linder-ganz","year":"2010","unstructured":"Linder-ganz E, Elsner JJ, Danino A, Guilak F (2010) A novel quantitative approach for evaluating contact mechanics of meniscal replacements. J Biomech Eng 132:1\u20136","journal-title":"J Biomech Eng"},{"issue":"1","key":"2158_CR15","doi-asserted-by":"crossref","first-page":"71","DOI":"10.32098\/mltj.01.2016.09","volume":"6","author":"J Vaquero","year":"2016","unstructured":"Vaquero J, Forriol F (2016) Meniscus tear surgery and meniscus replacement. Muscles Ligaments Tendons J 6(1):71\u201389","journal-title":"Muscles Ligaments Tendons J"},{"issue":"3","key":"2158_CR16","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1177\/03635465990270030901","volume":"27","author":"M Alhalki","year":"1999","unstructured":"Alhalki M, Howell SM, Hull ML (1999) How three methods for fixing a medial meniscal autograft affect Tibial contact mechanics. Am J Sports Med 27(3):320\u2013328","journal-title":"Am J Sports Med"},{"issue":"4","key":"2158_CR17","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1111\/joa.12223","volume":"225","author":"ACT Vrancken","year":"2014","unstructured":"Vrancken ACT et al (2014) 3D geometry analysis of the medial meniscus \u2013 a statistical shape modeling approach. J Anat 225(4):395\u2013402","journal-title":"J Anat"},{"issue":"8","key":"2158_CR18","doi-asserted-by":"crossref","first-page":"1427","DOI":"10.1016\/j.jbiomech.2015.02.034","volume":"48","author":"M Khoshgoftar","year":"2015","unstructured":"Khoshgoftar M, Vrancken ACT, van Tienen TG, Buma P, Janssen D, Verdonschot N (2015) The sensitivity of cartilage contact pressures in the knee joint to the size and shape of an anatomically shaped meniscal implant. J Biomech 48(8):1427\u20131435","journal-title":"J Biomech"},{"issue":"12","key":"2158_CR19","doi-asserted-by":"crossref","first-page":"2824","DOI":"10.1177\/0363546517713687","volume":"45","author":"CTA Vrancken","year":"2017","unstructured":"Vrancken CTA, Hannink G, Madej W, Verdonschot N, van Tienen TG, Buma P (2017) In vivo performance of a novel, anatomically shaped, Total meniscal prosthesis made of polycarbonate urethane: a 12-month evaluation in goats. Am J Sports Med 45(12):2824\u20132834","journal-title":"Am J Sports Med"},{"issue":"7","key":"2158_CR20","first-page":"1","volume":"10","author":"ACT Vrancken","year":"2015","unstructured":"Vrancken ACT, Madej W, Hannink G, Verdonschot N, Van Tienen TG, Puma P (2015) Short term evaluation of an anatomically shaped polycarbonate urethane Total meniscus replacement in a goat model. PLoS One 10(7):1\u201316","journal-title":"PLoS One"},{"issue":"6","key":"2158_CR21","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.1016\/j.knee.2014.08.006","volume":"21","author":"ACT Vrancken","year":"2014","unstructured":"Vrancken ACT, van Tienen TG, Hannink G, Janssen D, Verdonschot N, Buma P (2014) Releasing the circumferential fixation of the medial meniscus does not affect its kinematics. Knee 21(6):1033\u20131038","journal-title":"Knee"},{"key":"2158_CR22","unstructured":"van Tienen TG (2018) Joint prosthesis assembly. 10076417"},{"key":"2158_CR23","doi-asserted-by":"crossref","unstructured":"Shriram D, Praveen Kumar G, Cui F, Lee YHD, Subburaj K (2017) Evaluating the effects of material properties of artificial meniscal implant in the human knee joint using finite element analysis. Sci Rep 7(1)","DOI":"10.1038\/s41598-017-06271-3"},{"key":"2158_CR24","first-page":"383","volume":"52","author":"BJ Cole","year":"2003","unstructured":"Cole BJ, Carter TR, Rodeo SA (2003) Allograft meniscal transplantation: background, techniques, and results. Instr Course Lect 52:383\u2013396","journal-title":"Instr Course Lect"},{"issue":"3","key":"2158_CR25","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1016\/j.otsr.2012.11.019","volume":"99","author":"A Wajsfisz","year":"2013","unstructured":"Wajsfisz A, Meyer A, Makridis KG, Hardy P (2013) A new arthroscopic technique for lateral meniscal allograft transplantation: cadaver feasibility study. Orthop Traumatol Surg Res 99(3):299\u2013304","journal-title":"Orthop Traumatol Surg Res"},{"issue":"1","key":"2158_CR26","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1177\/03635465020300012601","volume":"30","author":"SV Sekaran","year":"2002","unstructured":"Sekaran SV, Hull ML, Howell SM (2002) Nonanatomic location of the posterior horn of a medial meniscal autograft implanted in a cadaveric knee adversely affects the pressure distribution on the tibial plateau. Am J Sports Med 30(1):74\u201382","journal-title":"Am J Sports Med"},{"key":"2158_CR27","doi-asserted-by":"crossref","unstructured":"Naghibi Beidokhti H, Janssen D, Van De Groes S, Verdonschot N (2017) The peripheral soft tissues should not be ignored in the finite element models of the human knee joint. Med Biol Eng Comput","DOI":"10.1007\/s11517-017-1757-0"},{"issue":"1","key":"2158_CR28","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1177\/0363546506291404","volume":"35","author":"M Dienst","year":"2007","unstructured":"Dienst M, Greis PE, Ellis BJ, Bachus KN, Burks RT (2007) Effect of lateral meniscal allograft sizing on contact mechanics of the lateral tibial plateau: an experimental study in human cadaveric knee joints. Am J Sports Med 35(1):34\u201342","journal-title":"Am J Sports Med"},{"issue":"6","key":"2158_CR29","doi-asserted-by":"crossref","first-page":"684","DOI":"10.1016\/0749-8063(95)90110-8","volume":"11","author":"ME Pollard","year":"1995","unstructured":"Pollard ME, Kang Q, Berg EE (1995) Radiographic sizing for meniscal transplantation. Arthrosc J Arthrosc Relat Surg 11(6):684\u2013687","journal-title":"Arthrosc J Arthrosc Relat Surg"},{"key":"2158_CR30","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jbiomech.2017.08.030","volume":"65","author":"H Naghibi Beidokhti","year":"2017","unstructured":"Naghibi Beidokhti H, Janssen D, Van De Groes S, Hazrati J, Van Den Boogaard T, Verdonschot N (2017) The influence of ligament modelling strategies on the predictive capability of finite element models of the human knee joint. J Biomech 65:1\u201311","journal-title":"J Biomech"},{"issue":"1","key":"2158_CR31","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1093\/rheumatology\/38.2.124","volume":"38","author":"DE Shepherd","year":"1999","unstructured":"Shepherd DE, Seedhom BB (1999) The \u2018instantaneous\u2019 compressive modulus of human articular cartilage in joints of the lower limb. Rheumatology (Oxford) 38(1):124\u2013132","journal-title":"Rheumatology (Oxford)"},{"issue":"1\u20133","key":"2158_CR32","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1023\/A:1010835316564","volume":"61","author":"GA Holzapfel","year":"2000","unstructured":"Holzapfel GA, Gasser TC, Ogden RW (2000) A new constitutive framework for arterial wall mechanics and a comparative study of material models. J Elast 61(1\u20133):1\u201348","journal-title":"J Elast"},{"key":"2158_CR33","unstructured":"Abaqus A and Simulia (2011) ABAQUS 6.11 Documentation, Dassault Syst. Simulia, pp 1100"},{"issue":"2016","key":"2158_CR34","doi-asserted-by":"crossref","first-page":"1123","DOI":"10.1016\/j.medengphy.2016.06.001","volume":"38","author":"H Naghibi Beidokhti","year":"2016","unstructured":"Naghibi Beidokhti H et al (2016) A comparison between dynamic implicit and explicit finite element simulations of the native knee joint. Med Eng Phys 38(2016):1123\u20131130","journal-title":"Med Eng Phys"},{"key":"2158_CR35","doi-asserted-by":"crossref","unstructured":"Rohlmann A et al (2014) Standardized loads acting in knee implants. PloS One 9(1)","DOI":"10.1371\/journal.pone.0086035"},{"key":"2158_CR36","volume-title":"F3141\u201315, standard guide for total knee replacement loading profiles","author":"ASTM","year":"2016","unstructured":"ASTM (2016) F3141\u201315, standard guide for total knee replacement loading profiles. ASTM International, West Conshohocken, PA"},{"issue":"2","key":"2158_CR37","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1115\/1.3138397","volume":"105","author":"WJ Grood","year":"1983","unstructured":"Grood WJ, Suntay ES (1983) A joint coordinate system for the clinical description of three-dimensional motions applications to the knee. J Biomech Eng 105(2):136\u2013144","journal-title":"J Biomech Eng"},{"key":"2158_CR38","unstructured":"Wang H, Fleischli JE, Zheng NN, Carolina N, Carolina N (2013) Transtibial versus anteromedial portal technique in single-bundle anterior cruciate ligament reconstruction outcomes of knee joint kinematics during walking. pp 1847\u20131856"},{"issue":"12","key":"2158_CR39","doi-asserted-by":"crossref","first-page":"1877","DOI":"10.1016\/j.jbiomech.2009.05.003","volume":"42","author":"M Kozanek","year":"2009","unstructured":"Kozanek M, Hosseini A, Liu F, van de Velde S, Gill TJ, Rubash HE, Li G (2009) Tibiofemoral kinematics and condylar motion during the stance phase of gait. J Biomech 42(12):1877\u20131884","journal-title":"J Biomech"},{"issue":"2","key":"2158_CR40","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1016\/j.jbiomech.2013.11.042","volume":"47","author":"H Wang","year":"2014","unstructured":"Wang H, Chen T, Torzilli P, Warren R, Maher S (2014) Dynamic contact stress patterns on the tibial plateaus during simulated gait: a novel application of normalized cross correlation. J Biomech 47(2):568\u2013574","journal-title":"J Biomech"},{"key":"2158_CR41","doi-asserted-by":"crossref","unstructured":"Shelburne KB, Torry MR, Pandy MG (2005) Muscle, ligament, and joint-contact forces at the knee during walking. Med Sci Sport Exerc (3)","DOI":"10.1249\/01.mss.0000180404.86078.ff"},{"issue":"15","key":"2158_CR42","doi-asserted-by":"crossref","first-page":"2948","DOI":"10.1016\/j.jbiomech.2010.07.013","volume":"43","author":"NA Netravali","year":"2010","unstructured":"Netravali NA, Giori NJ, Andriacchi TP (2010) Partial medial meniscectomy and rotational differences at the knee during walking. J Biomech 43(15):2948\u20132953","journal-title":"J Biomech"},{"issue":"10","key":"2158_CR43","doi-asserted-by":"crossref","first-page":"1582","DOI":"10.1097\/00005768-200210000-00009","volume":"34","author":"J Heino Brechter","year":"2002","unstructured":"Heino Brechter J, Powers CM (2002) Patellofemoral stress during walking in persons with and without patellofemoral pain. Med Sci Sports Exerc 34(10):1582\u20131593","journal-title":"Med Sci Sports Exerc"},{"issue":"2","key":"2158_CR44","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1016\/j.jbiomech.2004.02.024","volume":"38","author":"FW Werner","year":"2005","unstructured":"Werner FW, Ayers DC, Maletsky LP, Rullkoetter PJ (2005) The effect of valgus\/varus malalignment on load distribution in total knee replacements. J Biomech 38(2):349\u2013355","journal-title":"J Biomech"},{"key":"2158_CR45","doi-asserted-by":"crossref","unstructured":"Engin AE and Korde MS (1974) Biomechanics of normal and abnormal knee joint. J Biomech 7(4)","DOI":"10.1016\/0021-9290(74)90027-X"},{"issue":"5","key":"2158_CR46","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1016\/S0268-0033(01)00020-1","volume":"16","author":"JH Heegaard","year":"2001","unstructured":"Heegaard JH, Leyvraz PF, Hovey CB (2001) A computer model to simulate patellar biomechanics following total knee replacement: the effects of femoral component alignment. Clin Biomech 16(5):415\u2013423","journal-title":"Clin Biomech"},{"issue":"3","key":"2158_CR47","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1016\/j.jbiomech.2008.10.031","volume":"42","author":"CS Shin","year":"2009","unstructured":"Shin CS, Chaudhari AM, Andriacchi TP (2009) The effect of isolated valgus moments on ACL strain during single-leg landing: a simulation study. J Biomech 42(3):280\u2013285","journal-title":"J Biomech"},{"issue":"10","key":"2158_CR48","doi-asserted-by":"crossref","first-page":"1899","DOI":"10.1016\/j.jbiomech.2015.04.017","volume":"48","author":"H Marouane","year":"2015","unstructured":"Marouane H, Shirazi-Adl A, Hashemi J (2015) Quantification of the role of tibial posterior slope in knee joint mechanics and ACL force in simulated gait. J Biomech 48(10):1899\u20131905","journal-title":"J Biomech"},{"issue":"7","key":"2158_CR49","doi-asserted-by":"crossref","first-page":"1245","DOI":"10.1016\/j.ijfatigue.2006.10.013","volume":"29","author":"NP Zant","year":"2007","unstructured":"Zant NP, Wong CKY, Tong J (2007) Fatigue failure in the cement mantle of a simplified acetabular replacement model. Int J Fatigue 29(7):1245\u20131252","journal-title":"Int J Fatigue"},{"issue":"9","key":"2158_CR50","doi-asserted-by":"crossref","first-page":"8046","DOI":"10.1016\/j.actbio.2013.05.005","volume":"9","author":"P Mechanisms","year":"2013","unstructured":"R. Of, Mechanisms P (2013) NIH public access. Acta Biomater 9(9):8046\u20138058","journal-title":"Acta Biomater"},{"key":"2158_CR51","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/ar2170","volume":"9","author":"Y Abu-amer","year":"2007","unstructured":"Abu-amer Y, Darwech I, Clohisy JC (2007) Aseptic loosening of total joint replacements: mechanisms underlying osteolysis and potential therapies. Arthritis Res Ther 9:1\u20137","journal-title":"Arthritis Res Ther"},{"issue":"3","key":"2158_CR52","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1002\/jor.1100090315","volume":"9","author":"SM Snyder","year":"1991","unstructured":"Snyder SM, Schneider E (1991) Estimation of mechanical properties of cortical bone by computed tomography. J Orthop Res 9(3):422\u2013431","journal-title":"J Orthop Res"},{"key":"2158_CR53","first-page":"4664","volume":"27","author":"P Wang","year":"2013","unstructured":"Wang P, Guan P, Guo C, Zhu F, Konstantopoulos K, Wang Z (2013) Fluid shear stress-induced osteoarthritis : roles of cyclooxygenase-2 and its metabolic products in inducing the expression of proinflammatory cytokines and matrix metalloproteinases. J Fed Am Soc Exp Biol 27:4664\u20134677","journal-title":"J Fed Am Soc Exp Biol"},{"issue":"3","key":"2158_CR54","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1016\/S0021-9290(03)00267-7","volume":"37","author":"W Wilson","year":"2004","unstructured":"Wilson W, Van Donkelaar CC, Van Rietbergen B, Ito K, Huiskes R (2004) Stresses in the local collagen network of articular cartilage: a poroviscoelastic fibril-reinforced finite element study. J Biomech 37(3):357\u2013366","journal-title":"J Biomech"},{"issue":"9","key":"2158_CR55","doi-asserted-by":"crossref","first-page":"1922","DOI":"10.2106\/JBJS.G.00748","volume":"90","author":"R Allaire","year":"2008","unstructured":"Allaire R, Muriuki M, Gilbertson L, Harner CD (2008) Biomechanical consequences of a tear of the posterior root of the medial meniscus: similar to total meniscectomy. J Bone Jt Surg Ser A 90(9):1922\u20131931","journal-title":"J Bone Jt Surg Ser A"},{"issue":"1","key":"2158_CR56","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1055\/s-0030-1247787","volume":"21","author":"NN Verma","year":"2008","unstructured":"Verma NN, Kolb E, Cole BJ, Berkson MB, Garretson R, Farr J, Fregly B (2008) The effects of medial meniscal transplantation techniques on intra-articular contact pressures. J Knee Surg 21(1):20\u201326","journal-title":"J Knee Surg"},{"issue":"6","key":"2158_CR57","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1016\/j.clinbiomech.2012.01.005","volume":"27","author":"A Hemmerich","year":"2012","unstructured":"Hemmerich A, Van Der Merwe W, Batterham M, Vaughan CL (2012) Knee rotational laxity: an investigation of bilateral asymmetry for comparison with the contralateral uninjured knee. Clin Biomech 27(6):607\u2013612","journal-title":"Clin Biomech"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-020-02158-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11517-020-02158-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-020-02158-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,10]],"date-time":"2021-04-10T23:22:45Z","timestamp":1618096965000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11517-020-02158-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4,11]]},"references-count":57,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2020,6]]}},"alternative-id":["2158"],"URL":"https:\/\/doi.org\/10.1007\/s11517-020-02158-0","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4,11]]},"assertion":[{"value":"13 May 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 March 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 April 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Dr. Van Tienen is the head of stock options of ATRO Medical Company. The meniscus prosthesis studied in this study was provided by this company. The other authors declare no other potential conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}