{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T12:56:50Z","timestamp":1769950610500,"version":"3.49.0"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2020,7,23]],"date-time":"2020-07-23T00:00:00Z","timestamp":1595462400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,7,23]],"date-time":"2020-07-23T00:00:00Z","timestamp":1595462400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["51775368"],"award-info":[{"award-number":["51775368"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["51811530310"],"award-info":[{"award-number":["51811530310"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2020,10]]},"DOI":"10.1007\/s11517-020-02212-x","type":"journal-article","created":{"date-parts":[[2020,7,23]],"date-time":"2020-07-23T01:02:45Z","timestamp":1595466165000},"page":"2291-2304","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Deflection simulation for a needle adjusted by the insertion orientation angle and axial rotation during insertion in the muscle-contained double-layered tissue"],"prefix":"10.1007","volume":"58","author":[{"given":"Wanyu","family":"Liu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhiyong","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peina","family":"Fang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5518-5335","authenticated-orcid":false,"given":"Shan","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,7,23]]},"reference":[{"key":"2212_CR1","first-page":"3361","volume-title":"Needle control along desired tracks in robotic prostate brachytherapy","author":"N Abolhassani","year":"2007","unstructured":"Abolhassani N, Patel R, Ayazi F (2007) Needle control along desired tracks in robotic prostate brachytherapy. IEEE International Conference on Systems, Man and Cybernetics, pp 3361\u20133366"},{"key":"2212_CR2","doi-asserted-by":"publisher","DOI":"10.1115\/1.4030374","volume":"138","author":"AC Barnett","year":"2016","unstructured":"Barnett AC, Lee YS, Moore JZ (2016) Fracture mechanics model of needle cutting tissue. J Manuf Sci E-T ASME 138:011005","journal-title":"J Manuf Sci E-T ASME"},{"key":"2212_CR3","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1007\/s10237-004-0049-4","volume":"3","author":"JE Bischoff","year":"2004","unstructured":"Bischoff JE, Arruda EM, Grosh K (2004) A rheological network model for the continuum anisotropic and viscoelastic behavior of soft tissue. Biomech Model Mechan 3:56\u201365","journal-title":"Biomech Model Mechan"},{"issue":"3","key":"2212_CR4","doi-asserted-by":"publisher","first-page":"688","DOI":"10.1002\/jmri.21067","volume":"26","author":"P Blumenfeld","year":"2007","unstructured":"Blumenfeld P, Hata N, DiMaio S, Zou K, Haker S, Fichtinger G, Tempany C (2007) Transperineal prostate biopsy under magnetic resonance image guidance: a needle placement accuracy study. J Magn Reson Imaging 26(3):688\u2013694","journal-title":"J Magn Reson Imaging"},{"key":"2212_CR5","doi-asserted-by":"publisher","first-page":"3225","DOI":"10.1016\/j.actbio.2014.03.003","volume":"10","author":"M B\u00f6l","year":"2014","unstructured":"B\u00f6l M, Ehret AE, Leichsenring K, Weichert C, Kruse R (2014) On the anisotropy of skeletal muscle tissue under compression. Acta Biomater 10:3225\u20133234","journal-title":"Acta Biomater"},{"key":"2212_CR6","doi-asserted-by":"publisher","first-page":"2673","DOI":"10.1016\/j.jbiomech.2012.08.023","volume":"45","author":"M B\u00f6l","year":"2012","unstructured":"B\u00f6l M, Kruse R, Ehret AE, Leichsenring K, Siebert T (2012) Compressive properties of passive skeletal muscle-the impact of precise sample geometry on parameter identification in inverse finite element analysis. J Biomech 45:2673\u20132679","journal-title":"J Biomech"},{"key":"2212_CR7","doi-asserted-by":"publisher","first-page":"2865","DOI":"10.1118\/1.2962345","volume":"35","author":"I Buzurovic","year":"2008","unstructured":"Buzurovic I, Podder T, Yan K, Hu Y, Valicenti R, Dicker A, Yu Y (2008) Parameter optimization for brachytherapy robotic needle insertion and seed deposition. Med Phys 35:2865","journal-title":"Med Phys"},{"key":"2212_CR8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s11517-016-1505-x","volume":"55","author":"IM Buzurovic","year":"2017","unstructured":"Buzurovic IM, Salinic S, Orio PF, Nguyen PL, Cormack RA (2017) A novel approach to an automated needle insertion in brachytherapy procedures. Med Biol Eng Comput 55:1\u201315","journal-title":"Med Biol Eng Comput"},{"key":"2212_CR9","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1007\/978-1-4614-5025-2","volume-title":"Continuum mechanics of anisotropic materials","author":"SC Cowin","year":"2013","unstructured":"Cowin SC (2013) Continuum mechanics of anisotropic materials. Springer, New York, pp 83\u201399"},{"key":"2212_CR10","doi-asserted-by":"crossref","unstructured":"Feng Y, Lee CH, Sun L, Okamoto RJ, Ji S (2015) Automated estimation of elastic material parameters of a transversely isotropic material using asymmetric indentation and inverse finite element analysis. ASME 2015 International Mechanical Engineering Congress and Exposition, pp V003T03A007","DOI":"10.1115\/IMECE2015-51112"},{"key":"2212_CR11","doi-asserted-by":"publisher","first-page":"665","DOI":"10.1016\/j.medengphy.2012.04.007","volume":"34","author":"DJV Gerwen","year":"2012","unstructured":"Gerwen DJV, Dankelman J, Dobbelsteen JJVD (2012) Needle-tissue interaction forces--a survey of experimental data. Med Eng Phys 34:665\u2013680","journal-title":"Med Eng Phys"},{"key":"2212_CR12","doi-asserted-by":"crossref","unstructured":"Hing JT, Brooks AD, Desai JP (2006) Reality-based needle insertion simulation for haptic feedback in prostate brachytherapy. IEEE International Conference on Robotics and Automation, pp 619-624","DOI":"10.1109\/ROBOT.2006.1641779"},{"key":"2212_CR13","doi-asserted-by":"crossref","unstructured":"Jiang S, Wang X (2016) Mechanics-based interactive modeling for medical flexible needle insertion in consideration of nonlinear factors. J Comput Nonlin Dyn 11:011004-1\u2013011004-01100411","DOI":"10.1115\/1.4030747"},{"issue":"6","key":"2212_CR14","doi-asserted-by":"publisher","first-page":"376","DOI":"10.1097\/SIH.0000000000000186","volume":"11","author":"N Keleekai","year":"2016","unstructured":"Keleekai N, Schuster C, Murray C, King M, Stahl B, Labrozzi L, LeClair M, Glover K (2016) Improving nurses\u2019 peripheral intravenous catheter insertion knowledge, confidence, and skills using a simulation-based blended learning program: a randomized trial. Sim Healthc 11(6):376\u2013384","journal-title":"Sim Healthc"},{"key":"2212_CR15","doi-asserted-by":"crossref","unstructured":"Khadem M, Fallahi B, Rossa C, Sloboda RS (2015) A mechanics-based model for simulation and control of flexible needle insertion in soft tissue. IEEE International Conference on Robotics and Automation, pp 2264-2269","DOI":"10.1109\/ICRA.2015.7139499"},{"key":"2212_CR16","doi-asserted-by":"publisher","first-page":"800","DOI":"10.1109\/LRA.2016.2528301","volume":"1","author":"M Khadem","year":"2016","unstructured":"Khadem M, Rossa C, Sloboda R, Usmani N, Tavakoli M (2016) Mechanics of tissue cutting during needle insertion in biological tissue. IEEE Rob Aut Let 1:800\u2013807","journal-title":"IEEE Rob Aut Let"},{"key":"2212_CR17","doi-asserted-by":"publisher","first-page":"1640007","DOI":"10.1142\/S2424905X16400079","volume":"01","author":"M Khadem","year":"2016","unstructured":"Khadem M, Rossa C, Sloboda RS, Usmani N, Tavakoli M (2016) Ultrasound-guided model predictive control of needle steering in biological tissue. J Med Rob Res 01:1640007","journal-title":"J Med Rob Res"},{"key":"2212_CR18","doi-asserted-by":"crossref","unstructured":"Lee H, Kim J (2014) Estimation of flexible needle deflection in layered soft tissues with different elastic moduli. Med Biol Eng Comput 52:729\u2013740","DOI":"10.1007\/s11517-014-1173-7"},{"key":"2212_CR19","doi-asserted-by":"crossref","unstructured":"Lehmann T, Rossa C, Usmani N, Sloboda R, Tavakoli M. (2016). A real-time estimator for needle deflection during insertion into soft tissue based on adaptive modeling of needle-tissue interactions. IEEE\/ASME Transactions on Mechatronics, 1-1","DOI":"10.1109\/TMECH.2016.2598701"},{"key":"2212_CR20","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1016\/j.mechatronics.2017.10.008","volume":"48","author":"T Lehmann","year":"2017","unstructured":"Lehmann T, Rossa C, Usmani N, Sloboda R, Tavakoli M (2017) Deflection modeling for a needle actuated by lateral force and axial rotation during insertion in soft phantom tissue. Mechatronics 48:43\u201352","journal-title":"Mechatronics"},{"key":"2212_CR21","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1093\/bja\/85.2.238","volume":"85","author":"MC Lewis","year":"2000","unstructured":"Lewis MC, Lafferty JP, Sacks MS, Pallares VS, Terriet M (2000) How much work is required to puncture dura with tuohy needles? Brit J Anaesth 85:238\u2013241","journal-title":"Brit J Anaesth"},{"issue":"4","key":"2212_CR22","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1097\/SIH.0b013e31821d08a9","volume":"6","author":"C Loukas","year":"2011","unstructured":"Loukas C, Nikiteas N, Kanakis M, Georgiou E (2011) Evaluating the effectiveness of virtual reality simulation training in intravenous cannulation. Sim Healthc 6(4):213\u2013217","journal-title":"Sim Healthc"},{"key":"2212_CR23","doi-asserted-by":"publisher","first-page":"6027","DOI":"10.1088\/0031-9155\/52\/19\/021","volume":"52","author":"MA Meltsner","year":"2007","unstructured":"Meltsner MA, Ferrier NJ, Thomadsen BR (2007) Observations on rotating needle insertions using a brachytherapy robot. Phys Med Biol 52:6027\u20136037","journal-title":"Phys Med Biol"},{"key":"2212_CR24","doi-asserted-by":"publisher","first-page":"1716","DOI":"10.1007\/s10439-014-1203-5","volume":"43","author":"P Moreira","year":"2015","unstructured":"Moreira P, Misra S (2015) Biomechanics-based curvature estimation for ultrasound-guided flexible needle steering in biological tissues. Ann Biomed Eng 43:1716\u20131726","journal-title":"Ann Biomed Eng"},{"key":"2212_CR25","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1016\/j.jmbbm.2009.03.004","volume":"3","author":"DA Morrow","year":"2010","unstructured":"Morrow DA, Donahue TLH, Odegard GM, Kaufman KR (2010) Transversely isotropic tensile material properties of skeletal muscle tissue. J Mech Behav Biomed 3:124\u2013129","journal-title":"J Mech Behav Biomed"},{"key":"2212_CR26","doi-asserted-by":"publisher","first-page":"1707","DOI":"10.1109\/TBME.2004.831542","volume":"51","author":"AM Okamura","year":"2004","unstructured":"Okamura AM, Simone C, Leary M (2004) Force modeling for needle insertion into soft tissue. IEEE Trans Biomed Eng 51:1707\u20131716","journal-title":"IEEE Trans Biomed Eng"},{"key":"2212_CR27","doi-asserted-by":"crossref","unstructured":"Roesthuis RJ, Abayazid M, Misra S (2012) Mechanics-based model for predicting in-plane needle deflection with multiple bends. The 4th IEEE RAS\/EMBS International Conference on Biomedical Robotics and Biomechatronics, 49: 69-74","DOI":"10.1109\/BioRob.2012.6290829"},{"key":"2212_CR28","first-page":"2557","volume":"32","author":"RJ Roesthuis","year":"2011","unstructured":"Roesthuis RJ, Veen YRJV, Jahya A, Misra S (2011) Mechanics of needle-tissue interaction. IEEE\/RSJ International Conference on Intelligent Robots and Systems 32:2557\u20132563","journal-title":"IEEE\/RSJ International Conference on Intelligent Robots and Systems"},{"key":"2212_CR29","doi-asserted-by":"publisher","first-page":"916","DOI":"10.1109\/LRA.2016.2527065","volume":"1","author":"C Rossa","year":"2016","unstructured":"Rossa C, Khadem M, Sloboda R, Usmani N, Tavakoli M (2016) Adaptive quasi-static modelling of needle deflection during steering in soft tissue. IEEE Rob Aut Let 1:916\u2013923","journal-title":"IEEE Rob Aut Let"},{"key":"2212_CR30","doi-asserted-by":"publisher","first-page":"1401","DOI":"10.1007\/s11517-016-1599-1","volume":"55","author":"C Rossa","year":"2017","unstructured":"Rossa C, Lehmann T, Sloboda R, Usmani N, Tavakoli MC (2017) A data-driven soft sensor for needle deflection in heterogeneous tissue using just-in-time modelling. Med Biol Eng Comput 55:1401\u20131414","journal-title":"Med Biol Eng Comput"},{"key":"2212_CR31","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1016\/j.conengprac.2017.03.004","volume":"62","author":"C Rossa","year":"2017","unstructured":"Rossa C, Tavakoli M (2017) Issues in closed-loop needle steering. Control Eng Pract 62:55\u201369","journal-title":"Control Eng Pract"},{"key":"2212_CR32","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1159\/000108147","volume":"20","author":"EC Ruvolo Jr","year":"2007","unstructured":"Ruvolo EC Jr, Stamatas GN, Kollias N (2007) Skin viscoelasticity displays site- and age-dependent angular anisotropy. Skin Pharmacol Physiol 20:313\u2013321","journal-title":"Skin Pharmacol Physiol"},{"issue":"1","key":"2212_CR33","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1016\/S0167-8140(00)00162-6","volume":"55","author":"R Taschereau","year":"2000","unstructured":"Taschereau R, Pouliot J, Roy J, Tremblay D (2000) Seed misplacement and stabilizing needles in transperineal permanent prostate implants. Radiother Oncol 55(1):59\u201363","journal-title":"Radiother Oncol"},{"issue":"10","key":"2212_CR34","doi-asserted-by":"publisher","first-page":"1361","DOI":"10.1177\/0278364914526627","volume":"33","author":"G Vrooijink","year":"2014","unstructured":"Vrooijink G, Abayazid M, Patil S, Alterovitz R, Misra S (2014) Needle path planning and steering in a three-dimensional non-static environment using two-dimensional ultrasound images. Int J Robot Res 33(10):1361\u20131374","journal-title":"Int J Robot Res"},{"key":"2212_CR35","first-page":"413","volume":"16","author":"X Wang","year":"2016","unstructured":"Wang X, Jiang S (2016) Study of the targeting error for percutaneous needle insertion into soft phantom material. J Mech Med Biol 16:413\u2013431","journal-title":"J Mech Med Biol"},{"key":"2212_CR36","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1080\/1023697X.2008.10668128","volume":"15","author":"K Yan","year":"2008","unstructured":"Yan K, Yu Y, Xiao D, Podder T, Buzurovic I, Hu Y et al (2008) Flexible needle-tissue interaction modelling using depth-varying mean parameter. HKIE Transactions 15:17\u201328. https:\/\/doi.org\/10.1080\/1023697X.2008.10668128","journal-title":"HKIE Transactions"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-020-02212-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11517-020-02212-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-020-02212-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,7,22]],"date-time":"2021-07-22T23:42:12Z","timestamp":1626997332000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11517-020-02212-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7,23]]},"references-count":36,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2020,10]]}},"alternative-id":["2212"],"URL":"https:\/\/doi.org\/10.1007\/s11517-020-02212-x","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,7,23]]},"assertion":[{"value":"19 March 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 June 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 July 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}