{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T13:16:09Z","timestamp":1740143769038,"version":"3.37.3"},"reference-count":53,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2020,8,21]],"date-time":"2020-08-21T00:00:00Z","timestamp":1597968000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,8,21]],"date-time":"2020-08-21T00:00:00Z","timestamp":1597968000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"name":"Grant of the Strategic Research Foundation at Private Universities from the Ministry of Education, Culture, Sports, Science, and Technology, Japan","award":["S1311045"],"award-info":[{"award-number":["S1311045"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2020,10]]},"DOI":"10.1007\/s11517-020-02231-8","type":"journal-article","created":{"date-parts":[[2020,8,21]],"date-time":"2020-08-21T10:20:45Z","timestamp":1598005245000},"page":"2587-2601","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Estimation of the effects of inset heights and slit configurations in an acetabular cup on the pull-out behavior of an artificial hip joint with a structure for preventing dislocation using finite element analysis"],"prefix":"10.1007","volume":"58","author":[{"given":"Yuki","family":"Kawamura","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mitsushi","family":"Ohmasa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takayuki","family":"Kobayashi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshihito","family":"Matsufuji","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Makoto","family":"Saito","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshinori","family":"Uwa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Saiji","family":"Washio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6668-356X","authenticated-orcid":false,"given":"Ei","family":"Yamamoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,8,21]]},"reference":[{"key":"2231_CR1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.15761\/ROM.1000106","volume":"1","author":"K Colic","year":"2016","unstructured":"Colic K, Sedmak A (2016) The current approach to research and design of the artificial hip prosthesis: a review. Rheumatol Orthop Med 1:1\u20137. https:\/\/doi.org\/10.15761\/ROM.1000106","journal-title":"Rheumatol Orthop Med"},{"key":"2231_CR2","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1016\/j.compositesb.2015.07.019","volume":"83","author":"S Affatato","year":"2015","unstructured":"Affatato S, Ruggiero A, Merola M (2015) Advanced biomaterials in hip joint arthroplasty. A review on polymer and ceramics composites as alternative bearings. Compos B Eng 83:276\u2013283. https:\/\/doi.org\/10.1016\/j.compositesb.2015.07.019","journal-title":"Compos B Eng"},{"key":"2231_CR3","doi-asserted-by":"publisher","first-page":"715","DOI":"10.1080\/14686996.2016.1240575","volume":"17","author":"S Ghosh","year":"2016","unstructured":"Ghosh S, Abanteriba S (2016) Status of surface modification technique for artificial hip implants. Sci Technol Adv Mater 17:715\u2013735. https:\/\/doi.org\/10.1080\/14686996.2016.1240575","journal-title":"Sci Technol Adv Mater"},{"key":"2231_CR4","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1080\/17453674.2016.1251255","volume":"88","author":"KG Seagrave","year":"2017","unstructured":"Seagrave KG, Troelsen A, Malchau H, Husted H, Gromov K (2017) Acetabular cup position and risk of dislocation in primary total hip arthroplasty: a systematic review of the literature. Acta Orthop 88:10\u201317. https:\/\/doi.org\/10.1080\/17453674.2016.1251255","journal-title":"Acta Orthop"},{"key":"2231_CR5","doi-asserted-by":"publisher","first-page":"797","DOI":"10.1016\/j.jbiomech.2014.12.021","volume":"48","author":"DR Summer","year":"2015","unstructured":"Summer DR (2015) Long-term implant fixation and stress-shielding in total hip replacement. J Biomech 48:797\u2013800. https:\/\/doi.org\/10.1016\/j.jbiomech.2014.12.021","journal-title":"J Biomech"},{"key":"2231_CR6","first-page":"7","volume":"72","author":"J Charnley","year":"1970","unstructured":"Charnley J (1970) Total hip replacement by low-friction arthroplasty. Clin Orthop Relat Res 72:7\u201321","journal-title":"Clin Orthop Relat Res"},{"key":"2231_CR7","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1007\/s00264-005-0032-4","volume":"30","author":"T Masaoka","year":"2006","unstructured":"Masaoka T, Yamamoto K, Shishido T, Katori Y, Mizoue T, Shirasu H, Nunoda D (2006) Study of hip joint dislocation after total hip arthroplasty. Int Orthop 30:26\u201330. https:\/\/doi.org\/10.1007\/s00264-005-0032-4","journal-title":"Int Orthop"},{"key":"2231_CR8","doi-asserted-by":"publisher","first-page":"410","DOI":"10.1007\/s11999-012-2561-7","volume":"471","author":"NG Wetters","year":"2013","unstructured":"Wetters NG, Murray TG, Moric M, Sporer SM, Paprosky WG, Della Valle CJ (2013) Risk factors for dislocation after revision total hip arthroplasty. Clin Orthop Relat Res 471:410\u2013416. https:\/\/doi.org\/10.1007\/s11999-012-2561-7","journal-title":"Clin Orthop Relat Res"},{"key":"2231_CR9","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1053\/jvet.1999.0010","volume":"28","author":"DJ Marcellin-Little","year":"1999","unstructured":"Marcellin-Little DJ, DeYoung BA, Doyens DH, DeYoung DJ (1999) Canine uncemented porous-coated anatomic total hip arthroplasty: results of a long-term prospective evaluation of 50 consecutive cases. Vet Surg 28:10\u201320. https:\/\/doi.org\/10.1053\/jvet.1999.0010","journal-title":"Vet Surg"},{"key":"2231_CR10","doi-asserted-by":"publisher","first-page":"703","DOI":"10.1016\/S0195-5616(92)50063-8","volume":"22","author":"RD Montgomery","year":"1992","unstructured":"Montgomery RD, Milton JL, Pernell R, Aberman HM (1992) Total hip arthroplasty for treatment of canine hip dysplasia. Vet Clin North Am Small Anim Pract 22:703\u2013719. https:\/\/doi.org\/10.1016\/S0195-5616(92)50063-8","journal-title":"Vet Clin North Am Small Anim Pract"},{"key":"2231_CR11","doi-asserted-by":"publisher","first-page":"505","DOI":"10.3415\/VCOT-08-09-0087","volume":"22","author":"WD Liska","year":"2009","unstructured":"Liska WD, Doyle N, Marcellin-Little DJ, Osborne A (2009) Total hip replacement in three cats: surgical technique, short-term outcome and comparison to femoral head osteotomy. Vet Comp Orthop Traumatol 22:505\u2013510. https:\/\/doi.org\/10.3415\/VCOT-08-09-0087","journal-title":"Vet Comp Orthop Traumatol"},{"key":"2231_CR12","doi-asserted-by":"publisher","first-page":"547","DOI":"10.1111\/j.2042-3292.2010.00118.x","volume":"22","author":"N Huggons","year":"2010","unstructured":"Huggons N, Andrea R, Grant C, Duncan C (2010) Total hip arthroplasty in the horse: overview, technical considerations and case report. Equine Vet Educ 22:547\u2013553. https:\/\/doi.org\/10.1111\/j.2042-3292.2010.00118.x","journal-title":"Equine Vet Educ"},{"key":"2231_CR13","doi-asserted-by":"publisher","first-page":"524","DOI":"10.1053\/jvet.2000.17858","volume":"29","author":"J Dyce","year":"2000","unstructured":"Dyce J, Wisner ER, Wang Q, Olmstead ML (2000) Evaluation of risk factors for luxation after total hip replacement in dogs. Vet Surg 29:524\u2013532. https:\/\/doi.org\/10.1053\/jvet.2000.17858","journal-title":"Vet Surg"},{"key":"2231_CR14","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1111\/jvim.12004","volume":"27","author":"DC Brown","year":"2013","unstructured":"Brown DC, Boston RC, Farrar JT (2013) Comparison of force plate gait analysis and owner assessment of pain using the canine brief pain inventory in dogs with osteoarthritis. J Vet Intern Med 27:22\u201330. https:\/\/doi.org\/10.1111\/jvim.12004","journal-title":"J Vet Intern Med"},{"key":"2231_CR15","first-page":"93","volume":"6","author":"BJ Carr","year":"2016","unstructured":"Carr BJ, Dycus DL (2016) Canine gait analysis. Today Vet Pract 6:93\u2013100","journal-title":"Today Vet Pract"},{"key":"2231_CR16","doi-asserted-by":"publisher","first-page":"1300","DOI":"10.2106\/00004623-200009000-00010","volume":"82","author":"RL Bartz","year":"2000","unstructured":"Bartz RL, Nobel PC, Kadakia NR, Tullos HS (2000) The effect of femoral component head size on posterior dislocation of the artificial hip joint. J Bone Joint Surg Am 82:1300\u20131307. https:\/\/doi.org\/10.2106\/00004623-200009000-00010","journal-title":"J Bone Joint Surg Am"},{"key":"2231_CR17","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1007\/s11517-017-1673-3","volume":"56","author":"WM Chi","year":"2018","unstructured":"Chi WM, Lin CC, Ho YJ, Lin HC, Chen JM (2018) Using nonlinear finite element models to analyse stress distribution and torque required for dislocation of newly developed total hip structure after prosthetic impingement. Med Biol Eng Comput 56:37\u201347. https:\/\/doi.org\/10.1007\/s11517-017-1673-3","journal-title":"Med Biol Eng Comput"},{"key":"2231_CR18","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1054\/arth.2003.50090","volume":"18","author":"GS Shapiro","year":"2003","unstructured":"Shapiro GS, Weiland DE, Markel DC, Padgett DE, Sculco TP, Pellicci PM (2003) The use of a constrained acetabular component for recurrent dislocation. J Arthroplast 18:250\u2013258. https:\/\/doi.org\/10.1054\/arth.2003.50090","journal-title":"J Arthroplast"},{"key":"2231_CR19","doi-asserted-by":"publisher","first-page":"180","DOI":"10.5312\/wjo.v5.i3.180","volume":"5","author":"ID Martino","year":"2014","unstructured":"Martino ID, Triantafyllopoulos GK, Sculco PK, Sculco TP (2014) Dual mobility cups in total hip arthroplasty. World J Orthop 5:180\u2013187. https:\/\/doi.org\/10.5312\/wjo.v5.i3.180","journal-title":"World J Orthop"},{"key":"2231_CR20","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1088\/0965-0393\/17\/4\/043001","volume":"17","author":"T Belytschko","year":"2009","unstructured":"Belytschko T, Gracie R, Ventura G (2009) A review of extended\/generalized finite element methods for material modeling. Model Simul Mater Sci Eng 17:1\u201324. https:\/\/doi.org\/10.1088\/0965-0393\/17\/4\/043001","journal-title":"Model Simul Mater Sci Eng"},{"key":"2231_CR21","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/j.commatsci.2007.02.014","volume":"41","author":"DC Charmpis","year":"2007","unstructured":"Charmpis DC, Schueller GI, Pellissetti MF (2007) The need for linking micromechanics of materials with stochastic finite elements: a challenge for materials science. Comput Mater Sci 41:27\u201337. https:\/\/doi.org\/10.1016\/j.commatsci.2007.02.014","journal-title":"Comput Mater Sci"},{"key":"2231_CR22","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1002\/nme.2914","volume":"84","author":"TP Fries","year":"2010","unstructured":"Fries TP, Belytschko T (2010) The extended\/generalized finite element method: an overview of the method and its applications. Int J Numer Methods Eng 84:253\u2013304. https:\/\/doi.org\/10.1002\/nme.2914","journal-title":"Int J Numer Methods Eng"},{"key":"2231_CR23","volume-title":"The finite element method for engineers","author":"LM Huebner","year":"1995","unstructured":"Huebner LM, Thornton MB, Byrom AK (1995) The finite element method for engineers. Wiley, New York"},{"key":"2231_CR24","doi-asserted-by":"publisher","first-page":"585","DOI":"10.1067\/mpr.2001.115251","volume":"85","author":"JP Geng","year":"2001","unstructured":"Geng JP, Tan KB, Liu GR (2001) Application of finite element analysis in implant dentistry: a review of the literature. J Prosthet Dent 85:585\u2013598. https:\/\/doi.org\/10.1067\/mpr.2001.115251","journal-title":"J Prosthet Dent"},{"key":"2231_CR25","doi-asserted-by":"publisher","first-page":"1731","DOI":"10.1016\/j.arth.2013.04.034","volume":"28","author":"Y Hirata","year":"2013","unstructured":"Hirata Y, Inaba Y, Kobayashi N, Ike H, Fujimaki H, Saito T (2013) Comparison of mechanical stress and change in bone mineral density between two types of femoral implant using finite element analysis. J Arthroplast 28:1731\u20131735. https:\/\/doi.org\/10.1016\/j.arth.2013.04.034","journal-title":"J Arthroplast"},{"key":"2231_CR26","doi-asserted-by":"publisher","first-page":"269","DOI":"10.11395\/aem.1.0_269","volume":"1","author":"D Morioka","year":"2016","unstructured":"Morioka D, Kitayama I, Nakano K, Kitano M, Yamanaka T, Koyama H, Morimoto T, Sonobe H, Miyazaki N (2016) Finite element analysis of trimmed plastic ankle-foot orthoses. Adv Exp Mech 1:269\u2013276. https:\/\/doi.org\/10.11395\/aem.1.0_269","journal-title":"Adv Exp Mech"},{"key":"2231_CR27","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1299\/jbse.4.365","volume":"4","author":"L Qian","year":"2009","unstructured":"Qian L, Todo M, Matsushita Y, Koyano K (2009) Finite element analysis of bone resorption around dental implant. J Biomech Sci Eng 4:365\u2013376. https:\/\/doi.org\/10.1299\/jbse.4.365","journal-title":"J Biomech Sci Eng"},{"key":"2231_CR28","doi-asserted-by":"publisher","first-page":"75","DOI":"10.3109\/13645700009063053","volume":"9","author":"N Rebelo","year":"2000","unstructured":"Rebelo N, Perry M (2000) Finite element analysis for the design of nitinol medical devices. Minim Invasive Ther Allied Technol 9:75\u201380. https:\/\/doi.org\/10.3109\/13645700009063053","journal-title":"Minim Invasive Ther Allied Technol"},{"key":"2231_CR29","doi-asserted-by":"publisher","first-page":"616","DOI":"10.1002\/cnm.2621","volume":"30","author":"C Valero","year":"2014","unstructured":"Valero C, Javierre E, Garcia-Aznar JM, Gomez-Benito MJ (2014) Nonlinear finite element simulations of injuries with free boundaries: application to surgical wounds. Int J Numer Method Biomed Eng 30:616\u2013633. https:\/\/doi.org\/10.1002\/cnm.2621","journal-title":"Int J Numer Method Biomed Eng"},{"key":"2231_CR30","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/j.clinbiomech.2018.09.002","volume":"59","author":"RMA Al-Dirini","year":"2018","unstructured":"Al-Dirini RMA, Martelli S, Huff D, Zhang J, Clement JG, Besier T, Taylor M (2018) Evaluating the primary stability of standard vs lateralised cementless femoral stems-a finite element study using a diverse patient cohort. Clin Biomech 59:101\u2013109. https:\/\/doi.org\/10.1016\/j.clinbiomech.2018.09.002","journal-title":"Clin Biomech"},{"key":"2231_CR31","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1016\/j.jmbbm.2017.01.018","volume":"69","author":"A Ashkanfar","year":"2017","unstructured":"Ashkanfar A, Langton DJ, Joyce TJ (2017) A large taper mismatch is one of the key factors behind high wear rates and failure at the taper junction of total hip replacements: a finite element wear analysis. J Mech Behav Biomed Mater 69:257\u2013266. https:\/\/doi.org\/10.1016\/j.jmbbm.2017.01.018","journal-title":"J Mech Behav Biomed Mater"},{"key":"2231_CR32","doi-asserted-by":"publisher","first-page":"512","DOI":"10.1016\/j.jbiomech.2009.09.039","volume":"43","author":"C Dopico-Gonzalez","year":"2010","unstructured":"Dopico-Gonzalez C, New AM, Browne M (2010) Probabilistic finite element analysis of the uncemented hip replacement-effect of femur characteristics and implant design geometry. J Biomech 43:512\u2013520. https:\/\/doi.org\/10.1016\/j.jbiomech.2009.09.039","journal-title":"J Biomech"},{"key":"2231_CR33","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1007\/s40846-016-0210-4","volume":"37","author":"L Ezquerra","year":"2017","unstructured":"Ezquerra L, Quilez MP, Perez MA, Albareda J, Seral B (2017) Range of movement for impingement and dislocation avoidance in total hip replacement predicted by finite element model. J Med Biol Eng 37:26\u201334. https:\/\/doi.org\/10.1007\/s40846-016-0210-4","journal-title":"J Med Biol Eng"},{"key":"2231_CR34","doi-asserted-by":"publisher","first-page":"817","DOI":"10.1007\/s00264-006-0226-4","volume":"83","author":"A Tonino","year":"2001","unstructured":"Tonino A, Oosterbos C, Rahmy A, Therin M, Doyle C (2001) Hydroxyapatite-coated acetabular components-histological and histomorphometric analysis of six cups retrieved at autopsy between three and seven years after successful implantation. J Bone Joint Surg 83:817\u2013825. https:\/\/doi.org\/10.1007\/s00264-006-0226-4","journal-title":"J Bone Joint Surg"},{"key":"2231_CR35","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1097\/01.blo.0000073342.50837.4a","volume":"414","author":"MK Harman","year":"2003","unstructured":"Harman MK, Hodge WA, Banks SA (2003) Closed reduction of constrained total hip arthroplasty. Clin Orthop Relat Res 414:121\u2013128. https:\/\/doi.org\/10.1097\/01.blo.0000073342.50837.4a","journal-title":"Clin Orthop Relat Res"},{"key":"2231_CR36","doi-asserted-by":"publisher","first-page":"1907","DOI":"10.1007\/s11999-011-2212-4","volume":"470","author":"PC Noble","year":"2012","unstructured":"Noble PC, Durrani SK, Usrey MM, Mathis KB, Bardakos NV (2012) Constrained cups appear incapable of meeting the demands of revision THA. Clin Orthop Relat Res 470:1907\u20131916. https:\/\/doi.org\/10.1007\/s11999-011-2212-4","journal-title":"Clin Orthop Relat Res"},{"key":"2231_CR37","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1243\/095441103765212703","volume":"217","author":"F Liu","year":"2003","unstructured":"Liu F, Jin ZM, Grigoris P, Hirt F, Rieker C (2003) Contact mechanics of metal-on-metal hip implants employing a metallic cup with a UHMWPE backing. J Instn Mech Engres 217:207\u2013213. https:\/\/doi.org\/10.1243\/095441103765212703","journal-title":"J Instn Mech Engres"},{"key":"2231_CR38","doi-asserted-by":"publisher","first-page":"e3149","DOI":"10.1002\/cnm.3149","volume":"35","author":"MS Uddin","year":"2018","unstructured":"Uddin MS, Chan GWC (2018) Reducing stress concentration on the cup rim of hip implants under edge loading. Int J Numer Meth Biomed 35:e3149. https:\/\/doi.org\/10.1002\/cnm.3149","journal-title":"Int J Numer Meth Biomed"},{"key":"2231_CR39","doi-asserted-by":"publisher","first-page":"1059","DOI":"10.1007\/s00170-008-1548-8","volume":"41","author":"T Fuxing","year":"2009","unstructured":"Fuxing T, Mingzhe L, Zhongyi C, Xiangji L (2009) Formability analysis on the process of multi-point forming for titanium alloy retiary sheet. Int J Adv Manuf Technol 41:1059\u20131065. https:\/\/doi.org\/10.1007\/s00170-008-1548-8","journal-title":"Int J Adv Manuf Technol"},{"key":"2231_CR40","doi-asserted-by":"publisher","first-page":"911","DOI":"10.1007\/s00402-018-2918-9","volume":"138","author":"YW Jang","year":"2018","unstructured":"Jang YW, Lim D, Seo H, Lee MC, Lee OS, Lee YS (2018) Role of an anatomically contoured plate and metal block for balanced stability between the implant and lateral hinge in open-wedge high-tibial osteotomy. Arch Orthop Trauma Surg 138:911\u2013920. https:\/\/doi.org\/10.1007\/s00402-018-2918-9","journal-title":"Arch Orthop Trauma Surg"},{"key":"2231_CR41","doi-asserted-by":"publisher","first-page":"1365","DOI":"10.1016\/S0142-9612(02)00514-8","volume":"24","author":"JS Bergstrom","year":"2003","unstructured":"Bergstrom JS, Rimnac CM, Kurtz SM (2003) Prediction of multiaxial mechanical behavior for conventional and highly crosslinked UHMWPE using a hybrid constitutive model. Biomaterials 24:1365\u20131380. https:\/\/doi.org\/10.1016\/S0142-9612(02)00514-8","journal-title":"Biomaterials"},{"key":"2231_CR42","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1016\/j.jmbbm.2016.07.002","volume":"63","author":"M Guezmil","year":"2016","unstructured":"Guezmil M, Bensalah W, Mezlini S (2016) Tribological behavior of UHMWPE against TiAl6V4 and CoCr28Mo alloys under dry and lubricated conditions. J Mech Behav Biomed Mater 63:375\u2013385. https:\/\/doi.org\/10.1016\/j.jmbbm.2016.07.002","journal-title":"J Mech Behav Biomed Mater"},{"key":"2231_CR43","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1111\/j.1532-950X.2011.00933.x","volume":"41","author":"DJ Marino","year":"2012","unstructured":"Marino DJ, Ireifej SJ, Loughin CA (2012) Micro total hip replacement in dogs and cats. Vet Surg 41:121\u2013129. https:\/\/doi.org\/10.1111\/j.1532-950X.2011.00933.x","journal-title":"Vet Surg"},{"key":"2231_CR44","doi-asserted-by":"publisher","first-page":"899","DOI":"10.1016\/j.cvsm.2017.03.005","volume":"47","author":"TD Schiller","year":"2017","unstructured":"Schiller TD (2017) BioMedtrix total hip replacement systems: an overview. Vet Clin Small Anim 47:899\u2013916. https:\/\/doi.org\/10.1016\/j.cvsm.2017.03.005","journal-title":"Vet Clin Small Anim"},{"key":"2231_CR45","doi-asserted-by":"publisher","first-page":"356","DOI":"10.1016\/S0921-5093(03)00330-7","volume":"358","author":"A Dasari","year":"2003","unstructured":"Dasari A, Misra RDK (2003) On the strain rate sensitivity of high density polyethylene and polypropylenes. Mater Sci Eng A 358:356\u2013371. https:\/\/doi.org\/10.1016\/S0921-5093(03)00330-7","journal-title":"Mater Sci Eng A"},{"key":"2231_CR46","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1016\/0883-5403(94)90133-3","volume":"9","author":"MJ Anderson","year":"1994","unstructured":"Anderson MJ, Murray WR, Skinner HB (1994) Constrained acetabular components. J Arthroplast 9:17\u201323. https:\/\/doi.org\/10.1016\/0883-5403(94)90133-3","journal-title":"J Arthroplast"},{"key":"2231_CR47","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1016\/S0921-5093(97)00806-X","volume":"243","author":"M Niinomi","year":"1998","unstructured":"Niinomi M (1998) Mechanical properties of biomedical titanium alloys. Mater Sci Eng A Struct Mater 243:231\u2013236. https:\/\/doi.org\/10.1016\/S0921-5093(97)00806-X","journal-title":"Mater Sci Eng A Struct Mater"},{"key":"2231_CR48","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1007\/s11340-007-9045-9","volume":"47","author":"EN Brown","year":"2007","unstructured":"Brown EN, Willms RB, Gray GT, Rae PJ, Cady CM, Vecchio KS, Flowers J, Martinez MY (2007) Influence of molecular conformation on the constitutive response of polyethylene: a comparison of HDPE, UHMWPE, and PEX. Exp Mech 47:381\u2013393. https:\/\/doi.org\/10.1007\/s11340-007-9045-9","journal-title":"Exp Mech"},{"key":"2231_CR49","doi-asserted-by":"publisher","first-page":"1463","DOI":"10.1016\/S0142-9612(99)00039-3","volume":"20","author":"OK Muratoglu","year":"1999","unstructured":"Muratoglu OK, Bragdon CR, O'Connor DO, Jasty M, Harris WH, Gul R, McGarry F (1999) Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE). Biomaterials 20:1463\u20131470. https:\/\/doi.org\/10.1016\/S0142-9612(99)00039-3","journal-title":"Biomaterials"},{"key":"2231_CR50","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1007\/s00281-011-0242-3","volume":"33","author":"I Catelas","year":"2011","unstructured":"Catelas I, Wimmer MA, Utzschneider S (2011) Polyethylene and metal wear particles: characteristics and biological effects. Semin Immunopathol 33:257\u2013271. https:\/\/doi.org\/10.1007\/s00281-011-0242-3","journal-title":"Semin Immunopathol"},{"key":"2231_CR51","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1007\/s004020050274","volume":"117","author":"S Kobayashi","year":"1998","unstructured":"Kobayashi S, Takaoka K, Tsukada A, Ueno M (1998) Polyethylene wear from femoral bipolar neck-cup impingement as a cause of femoral prosthetic loosening. Arch Orthop Trauma Surg 117:390\u2013391. https:\/\/doi.org\/10.1007\/s004020050274","journal-title":"Arch Orthop Trauma Surg"},{"key":"2231_CR52","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jmbbm.2018.07.017","volume":"87","author":"N Shahemi","year":"2018","unstructured":"Shahemi N, Liza S, Abbas AA, Merican AM (2018) Long-term wear failure analysis of UHMWPE acetabular cup in total hip replacement. J Mech Behav Biomed Mater 87:1\u20139. https:\/\/doi.org\/10.1016\/j.jmbbm.2018.07.017","journal-title":"J Mech Behav Biomed Mater"},{"key":"2231_CR53","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1097\/01.blo.0000218748.30236.40","volume":"447","author":"DE Padgett","year":"2006","unstructured":"Padgett DE, Lipman J, Robie B, Nestor BJ (2006) Influence of total hip design on dislocation: a computer model and clinical analysis. Clin Orthop Relat Res 447:48\u201352. https:\/\/doi.org\/10.1097\/01.blo.0000218748.30236.40","journal-title":"Clin Orthop Relat Res"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-020-02231-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11517-020-02231-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-020-02231-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,21]],"date-time":"2021-08-21T00:26:04Z","timestamp":1629505564000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11517-020-02231-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,21]]},"references-count":53,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2020,10]]}},"alternative-id":["2231"],"URL":"https:\/\/doi.org\/10.1007\/s11517-020-02231-8","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"type":"print","value":"0140-0118"},{"type":"electronic","value":"1741-0444"}],"subject":[],"published":{"date-parts":[[2020,8,21]]},"assertion":[{"value":"23 October 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 July 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 August 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}