{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,26]],"date-time":"2026-11-26T17:49:15Z","timestamp":1795715355458,"version":"4.11.3"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2020,8,28]],"date-time":"2020-08-28T00:00:00Z","timestamp":1598572800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,8,28]],"date-time":"2020-08-28T00:00:00Z","timestamp":1598572800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2020,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Advances in EEG filtering algorithms enable analysis of EEG recorded during motor tasks. Although methods such as artifact subspace reconstruction (ASR) can remove transient artifacts automatically, there is virtually no knowledge about how the vigor of bodily movements affects ASRs performance and optimal cut-off parameter selection process. We compared the ratios of removed and reconstructed EEG recorded during a cognitive task, single-leg stance, and fast walking using ASR with 10 cut-off parameters versus visual inspection. Furthermore, we used the repeatability and dipolarity of independent components to assess their quality and an automatic classification tool to assess the number of brain-related independent components. The cut-off parameter equivalent to the ratio of EEG removed in manual cleaning was strictest for the walking task. The quality index of independent components, calculated using RELICA, reached a maximum plateau for cut-off parameters of 10 and higher across all tasks while dipolarity was largely unaffected. The number of independent components within each task remained constant, regardless of the cut-off parameter used. Surprisingly, ASR performed better in motor tasks compared with non-movement tasks. The quality index seemed to be more sensitive to changes induced by ASR compared to dipolarity. There was no benefit of using cut-off parameters less than 10.<\/jats:p>","DOI":"10.1007\/s11517-020-02252-3","type":"journal-article","created":{"date-parts":[[2020,8,28]],"date-time":"2020-08-28T16:03:46Z","timestamp":1598630626000},"page":"2673-2683","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":37,"title":["The influence of motor tasks and cut-off parameter selection on artifact subspace reconstruction in EEG recordings"],"prefix":"10.1007","volume":"58","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0149-0967","authenticated-orcid":false,"given":"Phillipp","family":"Anders","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Helen","family":"M\u00fcller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nina","family":"Skj\u00e6ret-Maroni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Beatrix","family":"Vereijken","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jochen","family":"Baumeister","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,8,28]]},"reference":[{"key":"2252_CR1","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1016\/j.knosys.2013.02.014","volume":"45","author":"UR Acharya","year":"2013","unstructured":"Acharya UR, Sree SV, Swapna G, Martis RJ, Suri JS (2013) Automated EEG analysis of epilepsy: a review. Knowl-Based Syst 45:147\u2013165","journal-title":"Knowl-Based Syst"},{"key":"2252_CR2","doi-asserted-by":"crossref","unstructured":"Anders P, Lehmann T, M\u00fcller H, Gr\u00f8nvik KB, Skj\u00e6ret-Maroni N, Baumeister J, Vereijken B (2018) Exergames inherently contain cognitive elements as indicated by cortical processing. Front Behav Neurosci 12","DOI":"10.3389\/fnbeh.2018.00102"},{"key":"2252_CR3","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1016\/j.jneumeth.2014.05.012","volume":"235","author":"S Laszlo","year":"2014","unstructured":"Laszlo S, Ruiz-Blondet M, Khalifian N, Chu F, Jin Z (2014) A direct comparison of active and passive amplification electrodes in the same amplifier system. J Neurosci Methods 235:298\u2013307","journal-title":"J Neurosci Methods"},{"key":"2252_CR4","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2011\/130714","volume":"2011","author":"A Delorme","year":"2011","unstructured":"Delorme A, Mullen T, Kothe C, Akalin Acar Z, Bigdely-Shamlo N, Vankov A, Makeig S (2011) EEGLAB, SIFT, NFT, BCILAB, and ERICA: new tools for advanced EEG processing. Comput Intell Neurosci 2011:1\u201312","journal-title":"Comput Intell Neurosci"},{"issue":"2","key":"2252_CR5","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1016\/j.ijpsycho.2008.11.008","volume":"73","author":"S Makeig","year":"2009","unstructured":"Makeig S, Gramann K, Jung TP, Sejnowski TJ, Poizner H (2009) Linking brain, mind and behavior. Int J Psychophysiol 73(2):95\u2013100 Neural Process Clin Psychophysiol","journal-title":"Int J Psychophysiol"},{"key":"2252_CR6","first-page":"145","volume-title":"Advances in neural information processing systems","author":"S Makeig","year":"1996","unstructured":"Makeig S, Bell AJ, Jung TP, Sejnowski TJ (1996) Independent component analysis of electroencephalographic data. In: Advances in neural information processing systems, pp 145\u2013151"},{"key":"2252_CR7","doi-asserted-by":"publisher","first-page":"16","DOI":"10.3389\/fninf.2015.00016","volume":"9","author":"N Bigdely-Shamlo","year":"2015","unstructured":"Bigdely-Shamlo N, Mullen T, Kothe C, Su KM, Robbins KA (2015) The PREP pipeline: standardized preprocessing for large-scale EEG analysis. Front Neuroinform 9:16","journal-title":"Front Neuroinform"},{"issue":"2","key":"2252_CR8","doi-asserted-by":"publisher","first-page":"e30135","DOI":"10.1371\/journal.pone.0030135","volume":"7","author":"A Delorme","year":"2012","unstructured":"Delorme A, Palmer J, Onton J, Oostenveld R, Makeig S (2012) Independent EEG sources are dipolar. PLoS One 7(2):e30135","journal-title":"PLoS One"},{"issue":"10","key":"2252_CR9","doi-asserted-by":"publisher","first-page":"1745","DOI":"10.1016\/S1388-2457(00)00386-2","volume":"111","author":"TP Jung","year":"2000","unstructured":"Jung TP, Makeig S, Westerfield M, Townsend J, Courchesne E, Sejnowski TJ (2000) Removal of eye activity artifacts from visual event-related potentials in normal and clinical subjects. Clin Neurophysiol 111(10):1745\u20131758","journal-title":"Clin Neurophysiol"},{"key":"2252_CR10","unstructured":"Kothe CAE, Jung TP (2016) Artifact removal techniques with signal reconstruction. Google Patents. US Patent App. 14\/895,440"},{"key":"2252_CR11","doi-asserted-by":"crossref","unstructured":"Chang CY, Hsu SH, Pion-Tonachini L, Jung TP. Evaluation of artifact subspace reconstruction for automatic EEG artifact removal. In: 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). IEEE; 2018. p. 1242\u20131245","DOI":"10.1109\/EMBC.2018.8512547"},{"issue":"11","key":"2252_CR12","doi-asserted-by":"publisher","first-page":"2553","DOI":"10.1109\/TBME.2015.2481482","volume":"62","author":"TR Mullen","year":"2015","unstructured":"Mullen TR, Kothe CA, Chi YM, Ojeda A, Kerth T, Makeig S et al (2015) Real-time neuroimaging and cognitive monitoring using wearable dry EEG. IEEE Trans Biomed Eng 62(11):2553\u20132567","journal-title":"IEEE Trans Biomed Eng"},{"key":"2252_CR13","doi-asserted-by":"crossref","unstructured":"Pion-Tonachini L, Hsu S, Chang C, Jung T, Makeig S. Online automatic artifact rejection using the Real-time EEG Source-mapping Toolbox (REST). In: 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC); 2018. p. 106\u2013109","DOI":"10.1109\/EMBC.2018.8512191"},{"key":"2252_CR14","doi-asserted-by":"crossref","unstructured":"Chang C, Hsu S, Pion-Tonachini L, Jung T. Evaluation of Artifact Subspace Reconstruction for Automatic Artifact Components Removal in Multi-channel EEG Recordings. IEEE Transactions on Biomedical Engineering. 2019;p. 1\u20131","DOI":"10.1109\/EMBC.2018.8512547"},{"issue":"3","key":"2252_CR15","first-page":"3","volume":"52","author":"GH Klem","year":"1999","unstructured":"Klem GH, L\u00fcders HO, Jasper H, Elger C et al (1999) The ten-twenty electrode system of the international federation. Electroencephalogr Clin Neurophysiol 52(3):3\u20136","journal-title":"Electroencephalogr Clin Neurophysiol"},{"issue":"1","key":"2252_CR16","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.jneumeth.2003.10.009","volume":"134","author":"A Delorme","year":"2004","unstructured":"Delorme A, Makeig S (2004) EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis. J Neurosci Methods 134(1):9\u201321","journal-title":"J Neurosci Methods"},{"key":"2252_CR17","doi-asserted-by":"crossref","unstructured":"Winkler I, Debener S, M\u00fcller K, Tangermann M. On the influence of high-pass filtering on ICA-based artifact reduction in EEG-ERP. In: 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC); 2015. p. 4101\u20134105","DOI":"10.1109\/EMBC.2015.7319296"},{"key":"2252_CR18","doi-asserted-by":"publisher","first-page":"854","DOI":"10.1007\/11679363_106","volume-title":"Independent Component Analysis and Blind Signal Separation","author":"JA Palmer","year":"2006","unstructured":"Palmer JA, Kreutz-Delgado K, Makeig S (2006) Super-Gaussian Mixture Source Model for ICA. In: Rosca J, Erdogmus D, Pr\u00edncipe JC, Haykin S (eds) Independent Component Analysis and Blind Signal Separation. Springer, Berlin, pp 854\u2013861"},{"key":"2252_CR19","doi-asserted-by":"publisher","first-page":"1805","DOI":"10.1109\/ICASSP.2008.4517982","volume-title":"2008 IEEE International Conference on Acoustics, Speech and Signal Processing","author":"JA Palmer","year":"2008","unstructured":"Palmer JA, Makeig S, Kreutz-Delgado K, Rao BD (2008) Newton method for the ICA mixture model. In: 2008 IEEE International Conference on Acoustics, Speech and Signal Processing, pp 1805\u20131808"},{"issue":"3","key":"2252_CR20","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1002\/hbm.10061","volume":"17","author":"R Oostenveld","year":"2002","unstructured":"Oostenveld R, Oostendorp TF (2002) Validating the boundary element method for forward and inverse EEG computations in the presence of a hole in the skull. Hum Brain Mapp 17(3):179\u2013192","journal-title":"Hum Brain Mapp"},{"issue":"21","key":"2252_CR21","doi-asserted-by":"publisher","first-page":"5011","DOI":"10.1088\/0031-9155\/49\/21\/012","volume":"49","author":"Z Akalin-Acar","year":"2004","unstructured":"Akalin-Acar Z, Gen\u00e7er NG (2004) An advanced boundary element method (BEM) implementation for the forward problem of electromagnetic source imaging. Phys Med Biol 49(21):5011\u20135028","journal-title":"Phys Med Biol"},{"issue":"13","key":"2252_CR22","doi-asserted-by":"publisher","first-page":"3007","DOI":"10.1088\/0031-9155\/50\/13\/003","volume":"50","author":"NG Gen\u00e7er","year":"2005","unstructured":"Gen\u00e7er NG, Akalin-Acar Z (2005) Use of the isolated problem approach for multicompartment BEM models of electro-magnetic source imaging. Phys Med Biol 50(13):3007\u20133022","journal-title":"Phys Med Biol"},{"key":"2252_CR23","doi-asserted-by":"crossref","unstructured":"Piazza C, Miyakoshi M, Akalin-Acar Z, Cantiani C, Reni G, Bianchi AM, et al. An automated function for identifying eeg independent components representing bilateral source activity. In: XIV Mediterranean Conference onMedical and Biological Engineering and Computing 2016. Springer; 2016. p. 105\u2013109","DOI":"10.1007\/978-3-319-32703-7_22"},{"issue":"3","key":"2252_CR24","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1007\/s10115-017-1053-1","volume":"53","author":"L Pion-Tonachini","year":"2017","unstructured":"Pion-Tonachini L, Makeig S, Kreutz-Delgado K (2017) Crowd labeling latent Dirichlet allocation. Knowl Inf Syst 53(3):749\u2013765","journal-title":"Knowl Inf Syst"},{"key":"2252_CR25","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1016\/j.neuroimage.2014.09.010","volume":"103","author":"F Artoni","year":"2014","unstructured":"Artoni F, Menicucci D, Delorme A, Makeig S, Micera S (2014) RELICA: a method for estimating the reliability of independent components. NeuroImage. 103:391\u2013400","journal-title":"NeuroImage."},{"issue":"5","key":"2252_CR26","doi-asserted-by":"publisher","first-page":"056014","DOI":"10.1088\/1741-2560\/10\/5\/056014","volume":"10","author":"CA Kothe","year":"2013","unstructured":"Kothe CA, Makeig S (2013) BCILAB: a platform for brain\u2013computer interface development. J Neural Eng 10(5):056014","journal-title":"J Neural Eng"},{"issue":"4","key":"2252_CR27","doi-asserted-by":"publisher","first-page":"1199","DOI":"10.1016\/j.neuroimage.2008.12.038","volume":"45","author":"DM Groppe","year":"2009","unstructured":"Groppe DM, Makeig S, Kutas M (2009) Identifying reliable independent components via split-half comparisons. Neuroimage. 45(4):1199\u20131211","journal-title":"Neuroimage."},{"key":"2252_CR28","unstructured":"R Core Team (2019) R: a language and environment for statistical computing. R Foundation for statistical computing, Vienna, Austria. URL https:\/\/www.R-project.org\/"},{"issue":"1","key":"2252_CR29","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1111\/j.2517-6161.1995.tb02031.x","volume":"57","author":"Y Benjamini","year":"1995","unstructured":"Benjamini Y, Hochberg Y (1995) Controlling the false discovery rate: a practical and powerful approach to multiple testing. J R Stat Soc Ser B Methodol 57(1):289\u2013300","journal-title":"J R Stat Soc Ser B Methodol"},{"key":"2252_CR30","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1016\/j.neuroimage.2019.05.026","volume":"198","author":"L Pion-Tonachini","year":"2019","unstructured":"Pion-Tonachini L, Kreutz-Delgado K, Makeig S (2019) ICLabel: an automated electroencephalographic independent component classifier, dataset, and website. NeuroImage. 198:181\u2013197","journal-title":"NeuroImage."}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-020-02252-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11517-020-02252-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-020-02252-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,12]],"date-time":"2024-08-12T19:52:22Z","timestamp":1723492342000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11517-020-02252-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,28]]},"references-count":30,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2020,11]]}},"alternative-id":["2252"],"URL":"https:\/\/doi.org\/10.1007\/s11517-020-02252-3","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,8,28]]},"assertion":[{"value":"19 December 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 August 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 August 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}