{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,12]],"date-time":"2026-06-12T00:16:20Z","timestamp":1781223380874,"version":"3.54.1"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2021,9,1]],"date-time":"2021-09-01T00:00:00Z","timestamp":1630454400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,9,1]],"date-time":"2021-09-01T00:00:00Z","timestamp":1630454400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100009473","name":"Universidad de M\u00e1laga","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100009473","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2021,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>A human motion capture system using an RGB-D camera could be a good option to understand the trunk limitations in spondyloarthritis. The aim of this study is to validate a human motion capture system using an RGB-D camera to analyse trunk movement limitations in spondyloarthritis patients. Cross-sectional study was performed where spondyloarthritis patients were diagnosed with a rheumatologist. The RGB-D camera analysed the kinematics of each participant during seven functional tasks based on rheumatologic assessment. The OpenNI2 library collected the depth data, the NiTE2 middleware detected a virtual skeleton and the MRPT library recorded the trunk positions. The gold standard was registered using an inertial measurement unit. The outcome variables were angular displacement, angular velocity and lineal acceleration of the trunk. Criterion validity and the reliability were calculated. Seventeen subjects (54.35 (11.75) years) were measured. The Bending task obtained moderate results in validity (r\u2009=\u20090.55\u20130.62) and successful results in reliability (ICC\u2009=\u20090.80\u20130.88) and validity and reliability of angular kinematic results in Chair task were moderate and (r\u2009=\u20090.60\u20130.74, ICC\u2009=\u20090.61\u20130.72). The kinematic results in Timed Up and Go test were less consistent. The RGB-D camera was documented to be a reliable tool to assess the movement limitations in spondyloarthritis depending on the functional tasks: Bending task. Chair task needs further research and the TUG analysis was not validated.<\/jats:p>\n                <jats:p><jats:bold>Graphical abstract<\/jats:bold><\/jats:p>\n                <jats:p>Comparation of both systems, required software for camera analysis, outcomes and final results of validity and reliability of each test.<\/jats:p>","DOI":"10.1007\/s11517-021-02406-x","type":"journal-article","created":{"date-parts":[[2021,9,1]],"date-time":"2021-09-01T03:37:34Z","timestamp":1630467454000},"page":"2127-2137","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Human motion capture for movement limitation analysis using an RGB-D camera in spondyloarthritis: a validation study"],"prefix":"10.1007","volume":"59","author":[{"given":"Manuel","family":"Trinidad-Fern\u00e1ndez","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"Cuesta-Vargas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Vaes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Beckw\u00e9e","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francisco-\u00c1ngel","family":"Moreno","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Javier","family":"Gonz\u00e1lez-Jim\u00e9nez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"Fern\u00e1ndez-Nebro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sara","family":"Manrique-Arija","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Inmaculada","family":"Ure\u00f1a-Garnica","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manuel","family":"Gonz\u00e1lez-S\u00e1nchez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,9,1]]},"reference":[{"key":"2406_CR1","doi-asserted-by":"publisher","first-page":"556","DOI":"10.1016\/j.semarthrit.2014.10.009","volume":"44","author":"A Boonen","year":"2015","unstructured":"Boonen A, Sieper J, van der Heijde D, Dougados M, Bukowski JF, Valluri S et al (2015) The burden of non-radiographic axial spondyloarthritis. Semin Arthritis Rheum 44:556\u2013562","journal-title":"Semin Arthritis Rheum"},{"key":"2406_CR2","doi-asserted-by":"publisher","first-page":"1320","DOI":"10.1002\/acr.22831","volume":"68","author":"C Stolwijk","year":"2016","unstructured":"Stolwijk C, van Onna M, Boonen A, van Tubergen A (2016) Global prevalence of spondyloarthritis: a systematic review and meta-regression analysis. Arthritis Care Res 68:1320\u20131331","journal-title":"Arthritis Care Res"},{"key":"2406_CR3","doi-asserted-by":"publisher","first-page":"477","DOI":"10.1016\/j.rdc.2012.08.002","volume":"38","author":"J Braun","year":"2012","unstructured":"Braun J, Sieper J (2012) Classification, diagnosis, and referral of patients with axial spondyloarthritis. Rheum Dis Clin N Am 38:477\u2013485","journal-title":"Rheum Dis Clin N Am"},{"key":"2406_CR4","first-page":"1109","volume":"15","author":"W Mau","year":"1988","unstructured":"Mau W, Zeidler H, Mau R, Majewski A, Freyschmidt J, Stangel W et al (1988) Clinical features and prognosis of patients with possible ankylosing spondylitis. Results of a 10-year followup. J Rheumatol. 15:1109\u201314","journal-title":"J Rheumatol."},{"key":"2406_CR5","doi-asserted-by":"publisher","first-page":"1364","DOI":"10.1093\/rheumatology\/ken224","volume":"47","author":"RN Jois","year":"2008","unstructured":"Jois RN, Macgregor AJ, Gaffney K (2008) Recognition of inflammatory back pain and ankylosing spondylitis in primary care. Rheumatol Oxf Engl 47:1364\u20131366","journal-title":"Rheumatol Oxf Engl"},{"key":"2406_CR6","doi-asserted-by":"publisher","first-page":"1532","DOI":"10.3899\/jrheum.150439","volume":"43","author":"TW Swinnen","year":"2016","unstructured":"Swinnen TW, Milosevic M, Van Huffel S, Dankaerts W, Westhovens R, de Vlam K (2016) Instrumented BASFI (iBASFI) Shows promising reliability and validity in the assessment of activity limitations in axial spondyloarthritis. J Rheumatol 43:1532\u20131540","journal-title":"J Rheumatol"},{"key":"2406_CR7","doi-asserted-by":"publisher","first-page":"R52","DOI":"10.1186\/ar3765","volume":"14","author":"SFE van Weely","year":"2012","unstructured":"van Weely SFE, van Denderen JC, Steultjens MPM, van der Leeden M, Nurmohamed MT, Dekker J et al (2012) Moving instead of asking? Performance-based tests and BASFI-questionnaire measure different aspects of physical function in ankylosing spondylitis. Arthritis Res Ther 14:R52","journal-title":"Arthritis Res Ther"},{"key":"2406_CR8","first-page":"188","volume":"168","author":"Y Xia","year":"2011","unstructured":"Xia Y, Cheung V, Garcia E, Ding H, Karunaithi M (2011) Development of an automated physical activity classification application for mobile phones. Stud Health Technol Inform 168:188\u2013194","journal-title":"Stud Health Technol Inform"},{"key":"2406_CR9","doi-asserted-by":"publisher","first-page":"719","DOI":"10.1016\/j.jmsy.2014.07.011","volume":"33","author":"D Regazzoni","year":"2014","unstructured":"Regazzoni D, de Vecchi G, Rizzi C (2014) RGB cams vs RGB-D sensors: low cost motion capture technologies performances and limitations. J Manuf Syst 33:719\u2013728","journal-title":"J Manuf Syst"},{"key":"2406_CR10","doi-asserted-by":"publisher","first-page":"1062","DOI":"10.1016\/j.gaitpost.2014.01.008","volume":"39","author":"B Galna","year":"2014","unstructured":"Galna B, Barry G, Jackson D, Mhiripiri D, Olivier P, Rochester L (2014) Accuracy of the Microsoft Kinect sensor for measuring movement in people with Parkinson\u2019s disease. Gait Posture 39:1062\u20131068","journal-title":"Gait Posture"},{"key":"2406_CR11","doi-asserted-by":"crossref","unstructured":"Trinidad-Fern\u00e1ndez M, Beckw\u00e9e D, Cuesta-Vargas A, Gonz\u00e1lez-S\u00e1nchez M, Moreno F-A, Gonz\u00e1lez-Jim\u00e9nez J, et al. (2020) Validation, reliability, and responsiveness outcomes of kinematic assessment with an RGB-D camera to analyze movement in subacute and chronic low back pain. Sensors 20","DOI":"10.3390\/s20030689"},{"key":"2406_CR12","doi-asserted-by":"crossref","unstructured":"Moreno F-\u00c1, Merch\u00e1n-Baeza JA, Gonz\u00e1lez-S\u00e1nchez M, Gonz\u00e1lez-Jim\u00e9nez J, Cuesta-Vargas AI (2017) Experimental validation of depth cameras for the parameterization of functional balance of patients in clinical tests. Sensors 17","DOI":"10.3390\/s17020424"},{"key":"2406_CR13","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1016\/j.gaitpost.2018.11.029","volume":"68","author":"RA Clark","year":"2019","unstructured":"Clark RA, Mentiplay BF, Hough E, Pua YH (2019) Three-dimensional cameras and skeleton pose tracking for physical function assessment: a review of uses, validity, current developments and Kinect alternatives. Gait Posture 68:193\u2013200","journal-title":"Gait Posture"},{"key":"2406_CR14","first-page":"100","volume":"52","author":"I Aranda Valera","year":"2018","unstructured":"Aranda Valera I, Mata Perdig\u00f3n F, Mart\u00ednez S\u00e1nchez I, Gonz\u00e1lez Navas C, Collantes Est\u00e9vez E, Garrido CJ (2018) Utilizaci\u00f3n de sensores inerciales para la evaluaci\u00f3n de la movilidad espinal en pacientes con espondiloartritis axial. Rehabil Madr 52:100\u2013106","journal-title":"Rehabil Madr"},{"key":"2406_CR15","doi-asserted-by":"publisher","first-page":"422","DOI":"10.1016\/j.math.2012.03.011","volume":"17","author":"JL Garrido-Castro","year":"2012","unstructured":"Garrido-Castro JL, Medina-Carnicer R, Schiottis R, Galisteo AM, Collantes-Estevez E, Gonzalez-Navas C (2012) Assessment of spinal mobility in ankylosing spondylitis using a video-based motion capture system. Man Ther 17:422\u2013426","journal-title":"Man Ther"},{"key":"2406_CR16","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1016\/j.math.2009.05.009","volume":"15","author":"K Saber-Sheikh","year":"2010","unstructured":"Saber-Sheikh K, Bryant EC, Glazzard C, Hamel A, Lee RYW (2010) Feasibility of using inertial sensors to assess human movement. Man Ther 15:122\u2013125","journal-title":"Man Ther"},{"key":"2406_CR17","doi-asserted-by":"publisher","first-page":"e79945","DOI":"10.1371\/journal.pone.0079945","volume":"8","author":"K Lebel","year":"2013","unstructured":"Lebel K, Boissy P, Hamel M, Duval C (2013) Inertial measures of motion for clinical biomechanics: comparative assessment of accuracy under controlled conditions - effect of velocity. PloS One. 8:e79945","journal-title":"PloS One."},{"key":"2406_CR18","doi-asserted-by":"publisher","first-page":"777","DOI":"10.1136\/ard.2009.108233","volume":"68","author":"M Rudwaleit","year":"2009","unstructured":"Rudwaleit M, van der Heijde D, Landew\u00e9 R, Listing J, Akkoc N, Brandt J et al (2009) The development of Assessment of SpondyloArthritis international Society classification criteria for axial spondyloarthritis (part II): validation and final selection. Ann Rheum Dis 68:777\u2013783","journal-title":"Ann Rheum Dis"},{"key":"2406_CR19","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1186\/1475-925X-13-156","volume":"13","author":"A Gal\u00e1n-Mercant","year":"2014","unstructured":"Gal\u00e1n-Mercant A, Bar\u00f3n-L\u00f3pez FJ, Labajos-Manzanares MT, Cuesta-Vargas AI (2014) Reliability and criterion-related validity with a smartphone used in timed-up-and-go test. Biomed Eng Online 13:156","journal-title":"Biomed Eng Online"},{"key":"2406_CR20","doi-asserted-by":"crossref","unstructured":"Kask T, Kuusik A (2018) Performance comparison of smartphones and a wearable motion sensor for patient m-assessment. 2018 16th Bienn Balt Electron Conf BEC. p. 1\u20134.","DOI":"10.1109\/BEC.2018.8600973"},{"key":"2406_CR21","doi-asserted-by":"publisher","first-page":"1254","DOI":"10.1093\/rheumatology\/kep190","volume":"48","author":"SFE van Weely","year":"2009","unstructured":"van Weely SFE, van Denderen CJ, van der Horst-Bruinsma IE, Nurmohamed MT, Dijkmans BAC, Dekker J et al (2009) Reproducibility of performance measures of physical function based on the BASFI, in ankylosing spondylitis. Rheumatol Oxf Engl 48:1254\u20131260","journal-title":"Rheumatol Oxf Engl"},{"key":"2406_CR22","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1111\/j.1532-5415.1991.tb01616.x","volume":"39","author":"D Podsiadlo","year":"1991","unstructured":"Podsiadlo D, Richardson S (1991) The timed \u201cUp & Go\u201d: a test of basic functional mobility for frail elderly persons. J Am Geriatr Soc 39:142\u2013148","journal-title":"J Am Geriatr Soc"},{"key":"2406_CR23","first-page":"451","volume":"21","author":"MH Cardiel","year":"2003","unstructured":"Cardiel MH, Londo\u00f1o JD, Guti\u00e9rrez E, Pacheco-Tena C, V\u00e1zquez-Mellado J, Burgos-Vargas R (2003) Translation, cross-cultural adaptation, and validation of the Bath Ankylosing Spondylitis Functional Index (BASFI), the Bath Ankylosing Spondylitis Disease Activity Index (BASDAI) and the Dougados Functional Index (DFI) in a Spanish speaking population with spondyloarthropathies. Clin Exp Rheumatol 21:451\u2013458","journal-title":"Clin Exp Rheumatol"},{"key":"2406_CR24","first-page":"372","volume":"31","author":"R Ariza-Ariza","year":"2004","unstructured":"Ariza-Ariza R, Hern\u00e1ndez-Cruz B, Navarro-Sarabia F (2004) La versi\u00f3n espa\u00f1ola del BASDAI es fiable y se correlaciona con la actividad de la enfermedad. Rev Esp Reumatol 31:372\u2013378","journal-title":"Rev Esp Reumatol"},{"key":"2406_CR25","unstructured":"Bautista-Molano W, Landew\u00e9 R, Kiltz U, Valle-O\u00f1ate R, van der Heijde D. ASAS Health Index for patients with spondyloarthritis: translation into Spanish, validation, reliability and construct validity [abstract]. Arthritis Rheumatol [Internet]. 2016 [cited 2018 Jan 16];68 (suppl 10). Available from: http:\/\/acrabstracts.org\/abstract\/asas-health-index-for-patients-with-spondyloarthritis-translation-into-spanish-validation-reliability-and-construct-validity\/"},{"key":"2406_CR26","unstructured":"Blanco J-L. Development of scientific applications with the mobile robot programming toolkit\u2014 the MRPT reference book [Internet]. 2010 [cited 2017 Nov 11]. Available from: http:\/\/www.mrpt.org\/tutorials\/the-mrpt-book"},{"key":"2406_CR27","unstructured":"MRPT\u2014Empowering C++ development in robotics [Internet]. [cited 2017 Nov 11]. Available from: http:\/\/www.mrpt.org\/"},{"key":"2406_CR28","doi-asserted-by":"publisher","first-page":"1627","DOI":"10.1021\/ac60214a047","volume":"36","author":"Savitzky Abraham","year":"1964","unstructured":"Abraham Savitzky, Golay MJE (1964) Smoothing and differentiation of data by simplified least squares procedures. Anal Chem 36:1627\u201339","journal-title":"Anal Chem"},{"key":"2406_CR29","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1037\/0033-2909.86.2.420","volume":"86","author":"PE Shrout","year":"1979","unstructured":"Shrout PE, Fleiss JL (1979) Intraclass correlations: uses in assessing rater reliability. Psychol Bull 86:420\u2013428","journal-title":"Psychol Bull"},{"key":"2406_CR30","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"Koo TK, Li MY (2016) A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med 15:155\u2013163","journal-title":"J Chiropr Med"},{"key":"2406_CR31","doi-asserted-by":"crossref","unstructured":"Mentiplay BF, Hasanki K, Perraton LG, Pua Y-H, Charlton PC, Clark RA (2018) Three-dimensional assessment of squats and drop jumps using the Microsoft Xbox One Kinect: reliability and validity. J Sports Sci 1\u20138","DOI":"10.1080\/02640414.2018.1445439"},{"key":"2406_CR32","doi-asserted-by":"publisher","first-page":"330","DOI":"10.1016\/j.gaitpost.2019.03.020","volume":"70","author":"M Wochatz","year":"2019","unstructured":"Wochatz M, Tilgner N, Mueller S, Rabe S, Eichler S, John M et al (2019) Reliability and validity of the Kinect V2 for the assessment of lower extremity rehabilitation exercises. Gait Posture 70:330\u2013335","journal-title":"Gait Posture"},{"key":"2406_CR33","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1177\/1545968314529475","volume":"29","author":"S Vernon","year":"2015","unstructured":"Vernon S, Paterson K, Bower K, McGinley J, Miller K, Pua Y-H et al (2015) Quantifying individual components of the timed up and go using the kinect in people living with stroke. Neurorehabil Neural Repair 29:48\u201353","journal-title":"Neurorehabil Neural Repair"},{"key":"2406_CR34","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1016\/j.medengphy.2018.12.020","volume":"66","author":"R Tanaka","year":"2019","unstructured":"Tanaka R, Ishii Y, Yamasaki T, Kawanishi H (2019) Measurement of the total body center of gravity during sit-to-stand motion using a markerless motion capture system. Med Eng Phys 66:91\u201395","journal-title":"Med Eng Phys"},{"key":"2406_CR35","doi-asserted-by":"publisher","first-page":"542","DOI":"10.1007\/s11633-017-1088-5","volume":"14","author":"J Carpentier","year":"2017","unstructured":"Carpentier J, Benallegue M, Laumond J-P (2017) On the centre of mass motion in human walking. Int J Autom Comput 14:542\u2013551","journal-title":"Int J Autom Comput"},{"key":"2406_CR36","doi-asserted-by":"publisher","first-page":"1437","DOI":"10.3390\/s120201437","volume":"12","author":"K Khoshelham","year":"2012","unstructured":"Khoshelham K, Elberink SO (2012) Accuracy and resolution of Kinect depth data for indoor mapping applications. Sensors 12:1437\u20131454","journal-title":"Sensors"},{"key":"2406_CR37","doi-asserted-by":"publisher","first-page":"369","DOI":"10.1007\/s11517-018-1868-2","volume":"57","author":"D Tan","year":"2019","unstructured":"Tan D, Pua Y-H, Balakrishnan S, Scully A, Bower KJ, Prakash KM et al (2019) Automated analysis of gait and modified timed up and go using the Microsoft Kinect in people with Parkinson\u2019s disease: associations with physical outcome measures. Med Biol Eng Comput 57:369\u2013377","journal-title":"Med Biol Eng Comput"},{"key":"2406_CR38","doi-asserted-by":"publisher","first-page":"1002","DOI":"10.4085\/1062-6050-52.10.12","volume":"52","author":"TC Mauntel","year":"2017","unstructured":"Mauntel TC, Padua DA, Stanley LE, Frank BS, DiStefano LJ, Peck KY et al (2017) Automated quantification of the landing error scoring system with a markerless motion-capture System. J Athl Train 52:1002\u20131009","journal-title":"J Athl Train"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-021-02406-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11517-021-02406-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-021-02406-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,2,16]],"date-time":"2022-02-16T23:02:39Z","timestamp":1645052559000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11517-021-02406-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9,1]]},"references-count":38,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2021,10]]}},"alternative-id":["2406"],"URL":"https:\/\/doi.org\/10.1007\/s11517-021-02406-x","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,9,1]]},"assertion":[{"value":"23 November 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 July 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 September 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 February 2022","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Update","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Springer Nature\u2019s version of this paper was updated to present the funding note.","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study has the Ethical Approvement of the Coordinating Committee for the Ethics of Biomedical Research of the Region of Andalusia (N28092017). An informed consent will be signed before the measurements start.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}