{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T13:16:29Z","timestamp":1740143789890,"version":"3.37.3"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2022,11,24]],"date-time":"2022-11-24T00:00:00Z","timestamp":1669248000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,11,24]],"date-time":"2022-11-24T00:00:00Z","timestamp":1669248000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Hochschule f\u00fcr angewandte Wissenschaften M\u00fcnchen"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2023,2]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>We propose a concise mathematical framework in order to compare detector configurations efficiently for x-ray beam monitoring in radiotherapy of cancer. This framework consists of the singular value decomposition (SVD) of the system matrix and the definition of an effective information threshold based on the relative error inequality utilizing the condition number of a matrix. The goal of this paper is to present the mathematical argument as well as to demonstrate its use for modeling the best detector configuration for monitoring x-ray beams in external beam therapy. This analysis depends neither on specific measurements of a given set of x-ray beams, nor does it depend in specific reconstruction algorithms of the beam shape, and therefore represents a configuration meta-analysis. In the results section, we compare three possible detector designs, each leading to a highly underdetermined system, and are able to determine their effective information content relative to each other. Furthermore, by changing design parameters, such as the geometric detector configuration, number of detectors, detector pixel size, and the x-ray beam blur, deeper insight in this challenging inverse problem is achieved and the most sensitive monitoring scheme is determined.<\/jats:p>","DOI":"10.1007\/s11517-022-02719-5","type":"journal-article","created":{"date-parts":[[2022,11,24]],"date-time":"2022-11-24T18:20:11Z","timestamp":1669314011000},"page":"341-356","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Selection of the most sensitive configuration of strip array detectors for x-ray beam monitoring in radiotherapy of cancer utilizing singular value decomposition"],"prefix":"10.1007","volume":"61","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5303-9334","authenticated-orcid":false,"given":"Wolfgang","family":"H\u00f6gele","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Piotr","family":"Zygmanski","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,11,24]]},"reference":[{"issue":"8","key":"2719_CR1","doi-asserted-by":"publisher","first-page":"08NT02","DOI":"10.1088\/1361-6560\/ab8109","volume":"65","author":"S Albert","year":"2020","unstructured":"Albert S, Brivio D, Aldelaijan S, Sajo E, Hesser J, Zygmanski P (2020) Towards customizable thin-panel low-Z detector arrays: electrode design for increased spatial resolution ion chamber arrays. Phys Med Biol 65(8):08NT02. https:\/\/doi.org\/10.1088\/1361-6560\/ab8109. PMID: 32187595","journal-title":"Phys Med Biol"},{"key":"2719_CR2","volume-title":"Aschenbrenner Master\u2019s Thesis: 2D MLC leaf position measurement from projection data","author":"P Katharina","year":"2014","unstructured":"Katharina P (2014) Aschenbrenner Master\u2019s Thesis: 2D MLC leaf position measurement from projection data. Medical Faculty Mannheim of Heidelberg University, Germany"},{"key":"2719_CR3","doi-asserted-by":"publisher","unstructured":"Brivio D, Albert S, Gagne MP, Freund E, Sajo E, Zygmanski P (2020) Nanoporous aerogel-based periodic high-energy electron current x-ray sensors. United Kingdom N. Web. https:\/\/doi.org\/10.1088\/1361-6463\/ab83c0https:\/\/doi.org\/10.1088\/1361-6463\/ab83c0","DOI":"10.1088\/1361-6463\/ab83c0 10.1088\/1361-6463\/ab83c0"},{"key":"2719_CR4","first-page":"701","volume":"26","author":"JP Culver","year":"2001","unstructured":"Culver JP, Ntziachristos V, Holboke MJ, Yodh AG (2001) Optimization of optode arrangements for diffuse optical tomography: a singular-value analysis, Opt. Lett. 26:701\u2013703","journal-title":"Lett."},{"key":"2719_CR5","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1007\/BF02442409","volume":"20","author":"AA Damen","year":"1982","unstructured":"Damen AA, van der Kam J (1982) The use of the singular value decomposition in electrocardiography. Med Biol Eng Comput 20:473\u2013482. https:\/\/doi.org\/10.1007\/BF02442409","journal-title":"Med Biol Eng Comput"},{"key":"2719_CR6","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1364\/JOSAA.21.000231","volume":"21","author":"EE Graves","year":"2004","unstructured":"Graves EE, Culver JP, Ripoll J, Weissleder R, Ntziachristos V (2004) Singular-value analysis and optimization of experimental parameters in fluorescence molecular tomography. J Opt Soc Am A 21:231\u2013241","journal-title":"J Opt Soc Am A"},{"key":"2719_CR7","doi-asserted-by":"crossref","unstructured":"Fujimoto K, Scherpen JMA (2008) Singular value analysis and balanced realizations for nonlinear systems. In: Rommes J, Schilders WHA, Vorst HAVD (eds) Model order reduction: theory, research aspects and applications. (13 ed., pp 251-272) (Mathematics in Industry; No. 13), pp 251\u2013271","DOI":"10.1007\/978-3-540-78841-6_12"},{"key":"2719_CR8","doi-asserted-by":"publisher","first-page":"015004","DOI":"10.1088\/2057-1976\/ab57ce","volume":"6","author":"Z Han","year":"2019","unstructured":"Han Z, Hacker F, Killoran J, Kukluk J, Aizer A, Zygmanski P (2019) Optimization of MLC parameters for TPS calculation and dosimetric verification: application to single isocenter radiosurgery of multiple brain lesions using VMAT. Biomed Phys Eng Express 6:015004. https:\/\/doi.org\/10.1088\/2057-1976\/ab57ce. PMID 33438592","journal-title":"Biomed Phys Eng Express"},{"issue":"1","key":"2719_CR9","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1186\/s13014-018-0972-7","volume":"13","author":"H Hirashima","year":"2018","unstructured":"Hirashima H, Nakamura M, Miyabe Y, Uto M, Nakamura K, Mizowaki T (2018) Monitoring of mechanical errors and their dosimetric impact throughout the course of non-coplanar continuous volumetric-modulated arc therapy. Radiat Oncol 13(1):27. https:\/\/doi.org\/10.1186\/s13014-018-0972-7. PMID: 29444693; PMCID: PMC5813375","journal-title":"Radiat Oncol"},{"key":"2719_CR10","doi-asserted-by":"crossref","unstructured":"Hoegele W, Loeschel R, Dobler B, Koelbl O, Zygmanski P (2013) Bayesian estimation applied to stochastic localization with constraints due to interfaces and boundaries. Mathematical Problems in Engineering","DOI":"10.1155\/2013\/960421"},{"key":"2719_CR11","doi-asserted-by":"publisher","first-page":"055011","DOI":"10.1088\/2057-1976\/ac7fbc","volume":"8","author":"W Hoegele","year":"2022","unstructured":"Hoegele W, Zygmanski P (2022) Strip detector array (SDA) for beam monitoring in radiotherapy: reconstruction of MLC parameters from multiple projections of flux. Biomed Phys Eng Express 8:055011","journal-title":"Biomed Phys Eng Express"},{"key":"2719_CR12","doi-asserted-by":"publisher","first-page":"4744","DOI":"10.1118\/1.2975222","volume":"35","author":"IS Kyprianou","year":"2008","unstructured":"Kyprianou IS, Badano A, Gallas BD, Myers KJ (2008) Singular value description of a digital radiographic detector: theory and measurements. Med Phys 35:4744\u20134756. https:\/\/doi.org\/10.1118\/1.2975222","journal-title":"Med Phys"},{"issue":"4","key":"2719_CR13","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1016\/j.media.2007.04.003","volume":"11","author":"T Lasser","year":"2007","unstructured":"Lasser T, Ntziachristos V (2007) Optimization of 360 degrees projection fluorescence molecular tomography. Med Image Anal 11(4):389\u201399. https:\/\/doi.org\/10.1016\/j.media.2007.04.003. Epub 2007 Apr 19. PMID: 17524701","journal-title":"Med Image Anal"},{"key":"2719_CR14","doi-asserted-by":"publisher","first-page":"1514","DOI":"10.1364\/BOE.1.001514","volume":"1","author":"F Leblond","year":"2010","unstructured":"Leblond F, Kenneth M, Tichauer, Pogue BW (2010) Singular value decomposition metrics show limitations of detector design in diffuse fluorescence tomography. Biomed Opt Express 1:1514\u20131531","journal-title":"Biomed Opt Express"},{"key":"2719_CR15","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1002\/acm2.13202","volume":"22","author":"SB Lim","year":"2021","unstructured":"Lim SB, Zwan BJ, Lee D, Greer PB, Lovelock DM (2021) A novel quality assurance procedure for trajectory log validation using phantom-less real-time latency corrected EPID images. J Appl Clin Med Phys 22:176\u2013185. https:\/\/doi.org\/10.1002\/acm2.13202","journal-title":"J Appl Clin Med Phys"},{"issue":"19","key":"2719_CR16","doi-asserted-by":"publisher","first-page":"5985","DOI":"10.1088\/0031-9155\/52\/19\/018","volume":"52","author":"F Lorenz","year":"2007","unstructured":"Lorenz F, Nalichowski A, Rosca F, Kung J, Wenz F, Zygmanski P (2007) Spatial dependence of MLC transmission in IMRT delivery. Phys Med Biol 52(19):5985\u201399. https:\/\/doi.org\/10.1088\/0031-9155\/52\/19\/018https:\/\/doi.org\/10.1088\/0031-9155\/52\/19\/018. Epub 2007 Sep 17. PMID: 17881814","journal-title":"Phys Med Biol"},{"issue":"5","key":"2719_CR17","doi-asserted-by":"publisher","first-page":"1605","DOI":"10.1118\/1.2717385","volume":"34","author":"F Lorenz","year":"2007","unstructured":"Lorenz F, Killoran JH, Wenz F, Zygmanski P (2007) An independent dose calculation algorithm for MLC-based stereotactic radiotherapy. Med Phys 34(5):1605\u201314. https:\/\/doi.org\/10.1118\/1.2717385https:\/\/doi.org\/10.1118\/1.2717385. PMID: 17555242","journal-title":"Med Phys"},{"issue":"3","key":"2719_CR18","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1088\/0031-9155\/53\/3\/004","volume":"53","author":"F Lorenz","year":"2008","unstructured":"Lorenz F, Nalichowski A, Rosca F, Killoran J, Wenz F, Zygmanski P (2008) An independent dose calculation algorithm for MLC-based radiotherapy including the spatial dependence of MLC transmission. Phys Med Biol 53(3):557\u201373. https:\/\/doi.org\/10.1088\/0031-9155\/53\/3\/004https:\/\/doi.org\/10.1088\/0031-9155\/53\/3\/004. Epub 2008 Jan 7. PMID: 18199902","journal-title":"Phys Med Biol"},{"key":"2719_CR19","doi-asserted-by":"crossref","unstructured":"Mayles P, Nahum A, Rosenwald J-C (eds) (2007) Handbook of radiotherapy physics: theory and practice. Taylor & Francis Group, Milton Park","DOI":"10.1201\/9781420012026"},{"issue":"5","key":"2719_CR20","doi-asserted-by":"publisher","first-page":"1237","DOI":"10.1088\/0031-9155\/51\/5\/013","volume":"51","author":"B Poppe","year":"2006","unstructured":"Poppe B, Thieke C, Beyer D, Kollhoff R, Djouguela A, R\u00fchmann A, Willborn KC, Harder D (2006) DAVID\u2013a translucent multi-wire transmission ionization chamber for in vivo verification of IMRT and conformal irradiation techniques. Phys Med Biol 51(5):1237\u201348. https:\/\/doi.org\/10.1088\/0031-9155\/51\/5\/013. Epub 2006 Feb 15. PMID: 16481690","journal-title":"Phys Med Biol"},{"key":"2719_CR21","doi-asserted-by":"publisher","first-page":"1231","DOI":"10.1002\/mp.15434","volume":"49","author":"J Renaud","year":"2022","unstructured":"Renaud J, Muir B (2022) Assessing the accuracy of electronic portal imaging device (EPID)-based dosimetry: i. Quantities influencing long-term stability. Med Phys 49:1231\u20131237. https:\/\/doi.org\/10.1002\/mp.15434","journal-title":"Med Phys"},{"issue":"6","key":"2719_CR22","doi-asserted-by":"publisher","first-page":"2224","DOI":"10.1118\/1.2911870","volume":"35","author":"F Rosca","year":"2008","unstructured":"Rosca F, Zygmanski P (2008) An EPID response calculation algorithm using spatial beam characteristics of primary, head scattered and MLC transmitted radiation. Med Phys 35(6):2224\u201334. https:\/\/doi.org\/10.1118\/1.2911870. PMID: 18649452","journal-title":"Med Phys"},{"key":"2719_CR23","volume-title":"Introduction to linear algebra","author":"G Strang","year":"2016","unstructured":"Strang G (2016) Introduction to linear algebra, 5th edn. Wellesley Cambridge Press, Wellesley","edition":"5th edn."},{"issue":"3","key":"2719_CR24","doi-asserted-by":"publisher","first-page":"337","DOI":"10.2478\/raon-2018-0013","volume":"52","author":"V Somai","year":"2018","unstructured":"Somai V, Legrady D, Tolnai G (2018) Singular value decomposition analysis of back projection operator of maximum likelihood expectation maximization PET image reconstruction. Radiol Oncol 52(3):337\u2013345. https:\/\/doi.org\/10.2478\/raon-2018-0013","journal-title":"Radiol Oncol"},{"issue":"6","key":"2719_CR25","doi-asserted-by":"publisher","first-page":"1346","DOI":"10.1109\/TITB.2010.2077306","volume":"14","author":"D Wang","year":"2010","unstructured":"Wang D, Liu X, Liu F, Bai J (2010) Full-angle fluorescence diffuse optical tomography with spatially coded parallel excitation. IEEE Trans Inf Technol Biomed 14(6):1346\u201354. https:\/\/doi.org\/10.1109\/TITB.2010.2077306https:\/\/doi.org\/10.1109\/TITB.2010.2077306. Epub 2010 Sep 20. PMID: 20858585","journal-title":"IEEE Trans Inf Technol Biomed"},{"key":"2719_CR26","doi-asserted-by":"crossref","unstructured":"Heng X, Dehghani H, Pogue BW, Springett R, Paulsen KD, Dunn JF (2003) Near-infrared imaging in the small animal brain: optimization of fiber positions, J Biomed Opt 8(1)","DOI":"10.1117\/1.1528597"},{"issue":"9","key":"2719_CR27","doi-asserted-by":"publisher","first-page":"4715","DOI":"10.1002\/mp.15048","volume":"48","author":"P Zygmanski","year":"2021","unstructured":"Zygmanski P, Halvorsen P (2021) Routine pretreatment patient-specific IMRT QA (PS-IMRT-QA) should be discontinued and replaced with a real-time on-board beam monitoring system (BMS). Med Phys 48(9):4715\u20134718. https:\/\/doi.org\/10.1002\/mp.15048https:\/\/doi.org\/10.1002\/mp.15048. Epub 2021 Jul 11. PMID: 34118073","journal-title":"Med Phys"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-022-02719-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11517-022-02719-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-022-02719-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,20]],"date-time":"2023-01-20T05:45:39Z","timestamp":1674193539000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11517-022-02719-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,24]]},"references-count":27,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2023,2]]}},"alternative-id":["2719"],"URL":"https:\/\/doi.org\/10.1007\/s11517-022-02719-5","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"type":"print","value":"0140-0118"},{"type":"electronic","value":"1741-0444"}],"subject":[],"published":{"date-parts":[[2022,11,24]]},"assertion":[{"value":"6 March 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 November 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 November 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}