{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T15:51:33Z","timestamp":1786981893097,"version":"build-2736575974"},"reference-count":43,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2023,1,23]],"date-time":"2023-01-23T00:00:00Z","timestamp":1674432000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,1,23]],"date-time":"2023-01-23T00:00:00Z","timestamp":1674432000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2023,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>This simulation study aimed to explore the effects of mass and mass distribution of powered ankle\u2013foot orthoses, on net joint moments and individual muscle forces throughout the lower limb. Using OpenSim inverse kinematics, dynamics, and static optimization tools, the gait cycles of ten subjects were analyzed. The biomechanical models of these subjects were appended with ideal powered ankle\u2013foot orthoses of different masses and actuator positions, as to determine the effect that these design factors had on the subject\u2019s kinetics during normal walking. It was found that when the mass of the device was distributed more distally and posteriorly on the leg, both the net joint moments and overall lower limb muscle forces were more negatively impacted. However, individual muscle forces were found to have varying results which were attributed to the flow-on effect of the orthosis, the antagonistic pairing of muscles, and how the activity of individual muscles affect each other. It was found that mass and mass distribution of powered ankle\u2013foot orthoses could be optimized as to more accurately mimic natural kinetics, reducing net joint moments and overall muscle forces of the lower limb, and must consider individual muscles as to reduce potentially detrimental muscle fatigue or muscular disuse.<\/jats:p>\n                  <jats:p>\n                    <jats:bold>Graphical Abstract<\/jats:bold>\n                  <\/jats:p>\n                  <jats:p>OpenSim modelling method to explore the effect of mass and mass distribution on muscle forces and joint moments, showing potential mass positioning and the effects of these positions, mass, and actuation on the muscle force integral.<\/jats:p>","DOI":"10.1007\/s11517-023-02778-2","type":"journal-article","created":{"date-parts":[[2023,1,23]],"date-time":"2023-01-23T04:08:40Z","timestamp":1674446920000},"page":"1167-1182","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Effects of powered ankle\u2013foot orthoses mass distribution on lower limb muscle forces\u2014a simulation study"],"prefix":"10.1007","volume":"61","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4921-7863","authenticated-orcid":false,"given":"Grace","family":"Marconi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alpha Agape","family":"Gopalai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sunita","family":"Chauhan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,1,23]]},"reference":[{"key":"2778_CR1","doi-asserted-by":"publisher","DOI":"10.1155\/2014\/867869","author":"M Alam","year":"2014","unstructured":"Alam M, Choudhury IA, Mamat AB (2014) Mechanism and design analysis of articulated ankle foot orthoses for drop-foot. Sci World J. https:\/\/doi.org\/10.1155\/2014\/867869","journal-title":"Sci World J"},{"issue":"4","key":"2778_CR2","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1080\/17483107.2019.1578424","volume":"15","author":"MG Alvarez-Perez","year":"2020","unstructured":"Alvarez-Perez MG, Garcia-Murillo MA, Cervantes-S\u00e1nchez JJ (2020) Robot-assisted ankle rehabilitation: a review. Disabil Rehabil Assist Technol 15(4):394\u2013408. https:\/\/doi.org\/10.1080\/17483107.2019.1578424","journal-title":"Disabil Rehabil Assist Technol"},{"issue":"3","key":"2778_CR3","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1080\/10255849908907988","volume":"2","author":"FC Anderson","year":"1999","unstructured":"Anderson FC, Pandy MG (1999) A dynamic optimization solution for vertical jumping in three dimensions. Comput Methods Biomech Biomed Eng 2(3):201\u2013231. https:\/\/doi.org\/10.1080\/10255849908907988","journal-title":"Comput Methods Biomech Biomed Eng"},{"issue":"5","key":"2778_CR4","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1115\/1.1392310","volume":"123","author":"FC Anderson","year":"2001","unstructured":"Anderson FC, Pandy MG (2001) Dynamic optimization of human walking. J Biomech Eng 123(5):381\u2013390. https:\/\/doi.org\/10.1115\/1.1392310","journal-title":"J Biomech Eng"},{"key":"2778_CR5","unstructured":"Anderson FC, Delp S, DeMers M et al (2012) OpenSim user\u2019s guide. Release 2.4. Stanford University"},{"issue":"4\u20135","key":"2778_CR6","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1016\/j.neucli.2015.09.005","volume":"45","author":"C Beyaert","year":"2015","unstructured":"Beyaert C, Vasa R, Frykberg GE (2015) Gait post-stroke: pathophysiology and rehabilitation strategies. Neurophysiol Clin 45(4\u20135):335\u2013355. https:\/\/doi.org\/10.1016\/j.neucli.2015.09.005","journal-title":"Neurophysiol Clin"},{"key":"2778_CR7","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1016\/j.gaitpost.2018.11.011","volume":"68","author":"M B\u0142a\u017ckiewicz","year":"2019","unstructured":"B\u0142a\u017ckiewicz M, Wit A (2019) Compensatory strategy for ankle dorsiflexion muscle weakness during gait in patients with drop-foot. Gait Posture 68:88\u201394. https:\/\/doi.org\/10.1016\/j.gaitpost.2018.11.011","journal-title":"Gait Posture"},{"issue":"9","key":"2778_CR8","doi-asserted-by":"publisher","first-page":"955","DOI":"10.1016\/j.clinbiomech.2011.05.007","volume":"26","author":"DJ Bregman","year":"2011","unstructured":"Bregman DJ, van der Krogt MM, de Groot V, Harlaar J, Wisse M, Collins SH (2011) The effect of ankle foot orthosis stiffness on the energy cost of walking: a simulation study. Clin Biomech 26(9):955\u2013961. https:\/\/doi.org\/10.1016\/j.clinbiomech.2011.05.007","journal-title":"Clin Biomech"},{"issue":"3","key":"2778_CR9","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1249\/mss.0b013e31802b3562","volume":"39","author":"RC Browning","year":"2006","unstructured":"Browning RC, Modica JR, Kram R, Goswami A (2006) The effects of adding mass to the legs on the energetics and biomechanics of walking. Med Sci Sports Exerc 39(3):515\u2013525. https:\/\/doi.org\/10.1249\/mss.0b013e31802b3562","journal-title":"Med Sci Sports Exerc"},{"key":"2778_CR10","doi-asserted-by":"publisher","unstructured":"Camargo J, Ramanathan A, Flanagan W, Young A (2021) A comprehensive, open-source dataset of lower limb biomechanics in multiple conditions of stairs, ramps, and level-ground ambulation and transitions. J Biomech 119. https:\/\/doi.org\/10.1016\/j.jbiomech.2021.110320","DOI":"10.1016\/j.jbiomech.2021.110320"},{"key":"2778_CR11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1080\/09638288.2021.1970248","volume":"5","author":"A Daryabor","year":"2021","unstructured":"Daryabor A, Kobayashi T, Yamamoto S, Lyons SM, Orendurff M, Baghban AA (2021) Effect of ankle-foot orthoses on functional outcome measurements in individuals with stroke: a systematic review and meta-analysis. Disabil Rehabil 5:1\u201316. https:\/\/doi.org\/10.1080\/09638288.2021.1970248","journal-title":"Disabil Rehabil"},{"issue":"8","key":"2778_CR12","doi-asserted-by":"publisher","first-page":"757","DOI":"10.1109\/10.102791","volume":"37","author":"SL Delp","year":"1990","unstructured":"Delp SL, Loan JP, Hoy MG, Zajac FE, Topp EL, Rosen JM (1990) An interactive graphics-based model of the lower extremity to study orthopaedic surgical procedures. IEEE Trans Biomed Eng 37(8):757\u2013767. https:\/\/doi.org\/10.1109\/10.102791","journal-title":"IEEE Trans Biomed Eng"},{"issue":"11","key":"2778_CR13","doi-asserted-by":"publisher","first-page":"1940","DOI":"10.1109\/TBME.2007.901024","volume":"54","author":"SL Delp","year":"2007","unstructured":"Delp SL, Anderson FC, Arnold AS, Loan P, Habib A, John CT, Guendelman E, Thelen DG (2007) OpenSim: open-source software to create and analyze dynamic simulations of movement. IEEE Trans Biomed Eng 54(11):1940\u20131950. https:\/\/doi.org\/10.1109\/TBME.2007.901024","journal-title":"IEEE Trans Biomed Eng"},{"issue":"11","key":"2778_CR14","doi-asserted-by":"publisher","first-page":"1014","DOI":"10.1016\/j.pmrj.2009.09.012","volume":"1","author":"A Esquenazi","year":"2009","unstructured":"Esquenazi A, Ofluoglu D, Hirai B, Kim S (2009) The effect of an ankle-foot orthosis on temporal spatial parameters and asymmetry of gait in hemiparetic patients. PM R 1(11):1014\u20131018. https:\/\/doi.org\/10.1016\/j.pmrj.2009.09.012","journal-title":"PM R"},{"issue":"4","key":"2778_CR15","doi-asserted-by":"publisher","first-page":"412","DOI":"10.3390\/brainsci11040412","volume":"11","author":"D Gomez-Vargas","year":"2021","unstructured":"Gomez-Vargas D, Ballen-Moreno F, Barria P, Aguilar R, Azorin JM, Munera M, Cifuentes CA (2021) The actuation system of the ankle exoskeleton T-FLEX: first use experimental validation in people with stroke. Brain Sci 11(4):412. https:\/\/doi.org\/10.3390\/brainsci11040412","journal-title":"Brain Sci"},{"issue":"5","key":"2778_CR16","doi-asserted-by":"publisher","first-page":"535","DOI":"10.1002\/mus.20284","volume":"31","author":"JM Gracies","year":"2005","unstructured":"Gracies JM (2005) Pathophysiology of spastic paresis. I: paresis and soft tissue changes. Muscle Nerve 31(5):535\u2013551. https:\/\/doi.org\/10.1002\/mus.20284","journal-title":"Muscle Nerve"},{"issue":"4","key":"2778_CR17","doi-asserted-by":"publisher","first-page":"780","DOI":"10.1016\/j.jbiomech.2012.11.024","volume":"46","author":"SR Hamner","year":"2013","unstructured":"Hamner SR, Delp SL (2013) Muscle contributions to fore-aft and vertical body mass center accelerations over a range of running speeds. J Biomech 46(4):780\u2013787. https:\/\/doi.org\/10.1016\/j.jbiomech.2012.11.024","journal-title":"J Biomech"},{"issue":"14","key":"2778_CR18","doi-asserted-by":"publisher","first-page":"2709","DOI":"10.1016\/j.jbiomech.2010.06.025","volume":"43","author":"SR Hamner","year":"2010","unstructured":"Hamner SR, Seth A, Delp SL (2010) Muscle contributions to propulsion and support during running. J Biomech 43(14):2709\u20132716. https:\/\/doi.org\/10.1016\/j.jbiomech.2010.06.025","journal-title":"J Biomech"},{"issue":"3","key":"2778_CR19","doi-asserted-by":"publisher","first-page":"031009","DOI":"10.1115\/1.4035472","volume":"139","author":"AK Hegarty","year":"2017","unstructured":"Hegarty AK, Petrella AJ, Kurz MJ, Silverman AK (2017) Evaluating the effects of ankle foot orthosis mechanical property assumptions on gait simulation muscle force results. J Biomech Eng 139(3):031009. https:\/\/doi.org\/10.1115\/1.4035472","journal-title":"J Biomech Eng"},{"issue":"2","key":"2778_CR20","doi-asserted-by":"publisher","first-page":"020905","DOI":"10.1115\/1.4029304","volume":"137","author":"JL Hicks","year":"2015","unstructured":"Hicks JL, Uchida TK, Seth A, Rajagopal A, Delp SL (2015) Is my model good enough? Best practices for verification and validation of musculoskeletal models and simulations of movement. J Biomech Eng 137(2):020905. https:\/\/doi.org\/10.1115\/1.4029304","journal-title":"J Biomech Eng"},{"key":"2778_CR21","unstructured":"Kubasad PR, Todeti SR, Kamat YD (2018) A review on designs of various ankle foot orthosis (AFO) used to treat drop foot disease. In: Sen D, Mohan S, Ananthasuresh G, (Eds) Mechanism and machine science. Lecture Notes in Mechanical Engineering. Springer, Singapore."},{"issue":"2","key":"2778_CR22","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1177\/0954411911429401","volume":"226","author":"YC Lin","year":"2012","unstructured":"Lin YC, Dorn TW, Schache AG, Pandy MG (2012) Comparison of different methods for estimating muscle forces in human movement. Proc Inst Mech Eng H J Eng Med. 226(2):103\u2013112. https:\/\/doi.org\/10.1177\/0954411911429401","journal-title":"Proc Inst Mech Eng H J Eng Med."},{"key":"2778_CR23","doi-asserted-by":"publisher","unstructured":"Matinmanesh A, Mallakzadeh M (2011) Inverse kinetic and kinematic analysis of drop-foot patient\u2019s walking. In: Proceedings of the 3rd International Conference on E-Health and Bioengineering (EHB); 2011 Nov 24\u201326; Ia\u015fi, Romania. https:\/\/doi.org\/10.1155\/2017\/3595461","DOI":"10.1155\/2017\/3595461"},{"key":"2778_CR24","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1016\/j.gaitpost.2018.06.162","volume":"65","author":"BF Mentiplay","year":"2018","unstructured":"Mentiplay BF, Banky M, Clark RA, Kahn MB, Williams G (2018) Lower limb angular velocity during walking at various speeds. Gait Posture 65:190\u2013196. https:\/\/doi.org\/10.1016\/j.gaitpost.2018.06.162","journal-title":"Gait Posture"},{"issue":"1","key":"2778_CR25","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1186\/s12984-018-0424-5","volume":"15","author":"M Moltedo","year":"2018","unstructured":"Moltedo M, Ba\u0107ek T, Verstraten T, Rodriguez-Guerrero C, Vanderborght B, Lefeber D (2018) Powered ankle-foot orthoses: the effects of the assistance on healthy and impaired users while walking. J Neuroeng Rehabil 15(1):86. https:\/\/doi.org\/10.1186\/s12984-018-0424-5","journal-title":"J Neuroeng Rehabil"},{"issue":"3\u20134","key":"2778_CR26","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1007\/s00508-016-1096-4","volume":"129","author":"W Pirker","year":"2017","unstructured":"Pirker W, Katzenschlager P (2017) Gait disorders in adults and the elderly: a clinical guide. Wien Klin Wochenschr 129(3\u20134):81\u201395. https:\/\/doi.org\/10.1007\/s00508-016-1096-4","journal-title":"Wien Klin Wochenschr"},{"issue":"11","key":"2778_CR27","doi-asserted-by":"publisher","first-page":"3236","DOI":"10.1589\/jpts.28.3236","volume":"28","author":"A Pourghasem","year":"2016","unstructured":"Pourghasem A, Takamjani IE, Karimi MT, Kamali M, Jannesari M, Salafian I (2016) The effect of a powered ankle foot orthosis on walking in a stroke subject: a case study. J Phys Ther Sci 28(11):3236\u20133240. https:\/\/doi.org\/10.1589\/jpts.28.3236","journal-title":"J Phys Ther Sci"},{"key":"2778_CR28","doi-asserted-by":"publisher","first-page":"2","DOI":"10.3389\/fnbot.2018.00002","volume":"12","author":"T Ramakrishnan","year":"2018","unstructured":"Ramakrishnan T, Lahiff CA, Reed KB (2018) Comparing gait with multiple physical asymmetries using consolidated metrics. Front Neurorobot 12:2. https:\/\/doi.org\/10.3389\/fnbot.2018.00002","journal-title":"Front Neurorobot"},{"issue":"1","key":"2778_CR29","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1186\/s12984-021-00815-5","volume":"18","author":"A Rodr\u00edguez-Fern\u00e1ndez","year":"2021","unstructured":"Rodr\u00edguez-Fern\u00e1ndez A, Lobo-Prat J, Font-Llagunes JM (2021) Systematic review on wearable lower-limb exoskeletons for gait training in neuromuscular impairments. J Neuroeng Rehabil 18(1):22. https:\/\/doi.org\/10.1186\/s12984-021-00815-5","journal-title":"J Neuroeng Rehabil"},{"key":"2778_CR30","doi-asserted-by":"publisher","unstructured":"Rosenberg M, Steele KM (2017) Simulated impacts of ankle foot orthoses on muscle demand and recruitment in typically-developing children and children with cerebral palsy and crouch gait. PLoS One 12(7). https:\/\/doi.org\/10.1371\/journal.pone.0180219","DOI":"10.1371\/journal.pone.0180219"},{"issue":"1","key":"2778_CR31","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1186\/s12984-018-0455-y","volume":"15","author":"E Russell Esposito","year":"2018","unstructured":"Russell Esposito E, Schmidtbauer KA, Wilken JM (2018) Experimental comparisons of passive and powered ankle-foot orthoses in individuals with limb reconstruction. J Neuroeng Rehabil 15(1):111. https:\/\/doi.org\/10.1186\/s12984-018-0455-y","journal-title":"J Neuroeng Rehabil"},{"issue":"11","key":"2778_CR32","doi-asserted-by":"publisher","first-page":"2975","DOI":"10.3390\/ma14112975","volume":"14","author":"P Serrao","year":"2021","unstructured":"Serrao P, Dhimole VK, Cho C (2021) Effect of ankle torque on the ankle\u2013foot orthosis joint design sustainability. Materials 14(11):2975. https:\/\/doi.org\/10.3390\/ma14112975","journal-title":"Materials"},{"key":"2778_CR33","doi-asserted-by":"publisher","unstructured":"Seth A, Hicks JL, Uchida TK et al (2018) OpenSim: simulating musculoskeletal dynamics and neuromuscular control to study human and animal movement. PLoS Comput Biol 14(7). https:\/\/doi.org\/10.1371\/journal.pcbi.1006223","DOI":"10.1371\/journal.pcbi.1006223"},{"issue":"4","key":"2778_CR34","doi-asserted-by":"publisher","first-page":"480","DOI":"10.1016\/j.gaitpost.2012.09.006","volume":"37","author":"S Schmid","year":"2018","unstructured":"Schmid S, Schweizer K, Romkes J, Lorenzetti S, Brunner R (2018) Secondary gait deviations in patients with and without neurological involvement: a systematic review. Gait Posture 37(4):480\u2013493. https:\/\/doi.org\/10.1016\/j.gaitpost.2012.09.006","journal-title":"Gait Posture"},{"key":"2778_CR35","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1016\/j.jmbbm.2019.07.020","volume":"99","author":"FS Shahar","year":"2019","unstructured":"Shahar FS, Hameed Sultan MT, Lee SH, Jawaid M, Shah AU, Safri SNA, Sivasankaran PN (2019) A review on the orthotics and prosthetics and the potential of kenaf composites as alternative materials for ankle-foot orthosis. J Mech Behav Biomed Mater 99:169\u2013185. https:\/\/doi.org\/10.1016\/j.jmbbm.2019.07.020","journal-title":"J Mech Behav Biomed Mater"},{"key":"2778_CR36","doi-asserted-by":"publisher","unstructured":"Stief F (2018) Variations of marker sets and models for standard gait analysis. In: Handbook of human motion. Springer, Cham. https:\/\/doi.org\/10.1007\/978-3-319-14418-4_26","DOI":"10.1007\/978-3-319-14418-4_26"},{"issue":"29","key":"2778_CR37","doi-asserted-by":"publisher","first-page":"30.1","DOI":"10.5013\/ijssst.a.17.29.30","volume":"17","author":"Z Tang","year":"2016","unstructured":"Tang Z, Liu L, Wang S, Liu Z, Qiu Y, Hao X, Wang Q (2016) Impact of fixed and non-fixed foot orthoses on fatigue of lower limb muscles. Int J Simul Syst Sci Technol 17(29):30.1-30.8. https:\/\/doi.org\/10.5013\/ijssst.a.17.29.30","journal-title":"Int J Simul Syst Sci Technol"},{"key":"2778_CR38","doi-asserted-by":"publisher","unstructured":"Uchida TK, Seth A, Pouya S, Dembia CL, Hick JL, Delp SL (2016) Simulating ideal assistive devices to reduce the metabolic cost of running. PLoS One 11(9). https:\/\/doi.org\/10.1371\/journal.pone.0163417","DOI":"10.1371\/journal.pone.0163417"},{"key":"2778_CR39","doi-asserted-by":"publisher","DOI":"10.1002\/9780470549148","volume-title":"Biomechanics and motor control of human movement","author":"DA Winter","year":"2009","unstructured":"Winter DA (2009) Biomechanics and motor control of human movement, 4th edn. Wiley, New York (NY), USA","edition":"4"},{"key":"2778_CR40","doi-asserted-by":"publisher","DOI":"10.1155\/2017\/3595461","author":"I Wiszomirska","year":"2017","unstructured":"Wiszomirska I, B\u0142a\u017ckiewicz M, Kaczmarczyk K, Brzuszkiewicz-Ku\u017amicka G, Wit A (2017) Effect of drop foot on spatiotemporal, kinematic, and kinetic parameters during gait. Appl Bionics Biomec. https:\/\/doi.org\/10.1155\/2017\/3595461","journal-title":"Appl Bionics Biomec"},{"key":"2778_CR41","doi-asserted-by":"publisher","unstructured":"Xia H, Kwon J, Pathak P, Ahn J, Shull PB, Park YL (2020) Design of a multi-functional soft ankle exoskeleton for foot-drop prevention, propulsion assistance, and inversion\/eversion stabilization. 8th IEEE International Conference on Biomedical Robotics and Biomechatronic (BioRob); 2020 Nov 29 \u2013 Dec 1; New York, NY, USA. https:\/\/doi.org\/10.1109\/BioRob49111.2020.9224420","DOI":"10.1109\/BioRob49111.2020.9224420"},{"issue":"1","key":"2778_CR42","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/0021-9290(89)90179-6","volume":"22","author":"GT Yamaguchi","year":"1989","unstructured":"Yamaguchi GT, Zajac FE (1989) A planar model of the knee joint to characterize the knee extensor mechanism. J Biomech 22(1):1\u201310. https:\/\/doi.org\/10.1016\/0021-9290(89)90179-6","journal-title":"J Biomech"},{"key":"2778_CR43","doi-asserted-by":"publisher","unstructured":"Yamamoto M, Shimatani K, Hasegawa M, Kurita Y (2019) Effect of an ankle-foot orthosis on gait kinematics and kinetics: case study of post-stroke gait using a musculoskeletal model and an orthosis model. Robomech J 6(9). https:\/\/doi.org\/10.1186\/s40648-019-0137-y","DOI":"10.1186\/s40648-019-0137-y"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-023-02778-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11517-023-02778-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-023-02778-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,9]],"date-time":"2023-04-09T21:13:00Z","timestamp":1681074780000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11517-023-02778-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,23]]},"references-count":43,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2023,5]]}},"alternative-id":["2778"],"URL":"https:\/\/doi.org\/10.1007\/s11517-023-02778-2","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1,23]]},"assertion":[{"value":"5 August 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 January 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 January 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 February 2023","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Update","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Springer Nature\u2019s version of this paper was updated to present the Open Access funding note.","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The deidentified human data used in this study is from the published open-source dataset from Camargo J, Ramanathan A, Flanagan W and Young A, \u201cA Comprehensive, Open-Source Dataset of Lower Limb Biomechanics in Multiple Conditions of Stairs, Ramps, and Level-Ground Ambulation and Transitions.\u201d This original study was approved by the Georgia Institute of Technology Review Board and was carried out in accordance with the US Health Insurance Portability and Accountability Act (HIPAA) regulations and the 1964 Declaration of Helsinki ethical standards.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}