{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,27]],"date-time":"2026-11-27T01:16:23Z","timestamp":1795742183457,"version":"4.11.3"},"reference-count":42,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2023,4,3]],"date-time":"2023-04-03T00:00:00Z","timestamp":1680480000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,4,3]],"date-time":"2023-04-03T00:00:00Z","timestamp":1680480000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100012818","name":"Comunidad de Madrid","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100012818","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100006302","name":"Universidad de Alcal\u00e1","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100006302","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2023,9]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Noise and artifacts affect strongly the quality of the electrocardiogram (ECG) in long-term ECG monitoring (LTM), making some of its parts impractical for diagnosis. The clinical severity of noise defines a qualitative quality score according to the manner clinicians make the interpretation of the ECG, in contrast to assess noise from a quantitative standpoint. So clinical noise refers to a scale of different levels of qualitative severity of noise which aims at elucidating which ECG fragments are valid to achieve diagnosis from a clinical point of view, unlike the traditional approach, which assesses noise in terms of quantitative severity. This work proposes the use of machine learning (ML) techniques to categorize different qualitative noise severity using a database annotated according to a clinical noise taxonomy as gold standard. A comparative study is carried out using five representative ML methods, namely,\n                    <jats:italic>K<\/jats:italic>\n                    neareast neighbors, decision trees, support vector machine, single-layer perceptron, and random forest. The models are fed by signal quality indexes characterizing the waveform in time and frequency domains, as well as from a statistical viewpoint, to distinguish between clinically valid ECG segments from invalid ones. A solid methodology to prevent overfitting to both the dataset and the patient is developed, taking into account balance of classes, patient separation, and patient rotation in the test set. All the proposed learning systems have demonstrated good classification performance, attaining a recall, precision, and F1 score up to 0.78, 0.80, and 0.77, respectively, in the test set by a single-layer perceptron approach. These systems provide a classification solution for assessing the clinical quality of the ECG taken from LTM recordings.\n                  <\/jats:p>","DOI":"10.1007\/s11517-023-02802-5","type":"journal-article","created":{"date-parts":[[2023,4,3]],"date-time":"2023-04-03T08:28:46Z","timestamp":1680510526000},"page":"2227-2240","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":21,"title":["Characterization of noise in long-term ECG monitoring with machine learning based on clinical criteria"],"prefix":"10.1007","volume":"61","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5913-341X","authenticated-orcid":false,"given":"Roberto","family":"Holgado-Cuadrado","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4714-1789","authenticated-orcid":false,"given":"Carmen","family":"Plaza-Seco","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7404-9371","authenticated-orcid":false,"given":"Lisandro","family":"Lovisolo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6593-1517","authenticated-orcid":false,"given":"Manuel","family":"Blanco-Velasco","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,4,3]]},"reference":[{"key":"2802_CR1","volume-title":"Cardiovascular pathology","author":"LM Buja","year":"2016","unstructured":"Buja LM, Butany J (2016) Cardiovascular pathology, 4th edn. Academic Press, San Diego","edition":"4th edn."},{"key":"2802_CR2","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1016\/j.cmpb.2015.12.008","volume":"127","author":"EJdS Luz","year":"2016","unstructured":"Luz EJdS, Schwartz WR, C\u00e1mara-Ch\u00e1vez G, Menotti D (2016) ECG\u2013based heartbeat classification for arrhythmia detection: a survey. Comput Methods Programs Biomed 127:144\u2013164","journal-title":"Comput Methods Programs Biomed"},{"issue":"3486","key":"2802_CR3","doi-asserted-by":"publisher","first-page":"1214","DOI":"10.1126\/science.134.3486.1214","volume":"134","author":"NJ Holter","year":"1961","unstructured":"Holter NJ (1961) New method for heart studies. Science 134(3486):1214\u20131220","journal-title":"Science"},{"key":"2802_CR4","doi-asserted-by":"crossref","unstructured":"Jiali W, Yue Z (2014) Research and implementation of Holter data format unification. In: International conference on medical biometrics, pp 141\u2013146","DOI":"10.1109\/ICMB.2014.32"},{"issue":"7","key":"2802_CR5","doi-asserted-by":"publisher","first-page":"1647","DOI":"10.1161\/01.STR.0000131269.69502.d9","volume":"35","author":"D Jabaudon","year":"2004","unstructured":"Jabaudon D, Sztajzel J, Sievert K, Landis T, Sztajzel R (2004) Usefulness of ambulatory 7\u2013day ECG monitoring for the detection of atrial fibrillation and flutter after acute stroke and transient ischemic attack. Stroke 35(7):1647\u20131651","journal-title":"Stroke"},{"issue":"3","key":"2802_CR6","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1016\/j.ijcard.2008.10.004","volume":"139","author":"N Dagres","year":"2010","unstructured":"Dagres N, Kottkamp H, Piorkowski C, Weis S, Arya A, Sommer P, Bode K, Gerds-Li JH, Kremastinos DT, Hindricks G (2010) Influence of the duration of Holter monitoring on the detection of arrhythmia recurrences after catheter ablation of atrial fibrillation: Implications for patient follow\u2013up. Int J Cardiol 139(3):305\u2013306","journal-title":"Int J Cardiol"},{"issue":"5","key":"2802_CR7","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1016\/j.amjcard.2010.04.027","volume":"106","author":"FJ Pastor-P\u00e9rez","year":"2010","unstructured":"Pastor-P\u00e9rez FJ, Manzano-Fern\u00e1ndez S, Goya-Esteban R, Pascual-Figal DA, Barquero-P\u00e9rez O et al (2010) Comparison of detection of arrhythmias in patients with chronic heart failure secondary to non-ischemic versus ischemic cardiomyopathy by 1 versus 7-day Holter monitoring. Am J Cardiol 106(5):677\u2013681","journal-title":"Am J Cardiol"},{"key":"2802_CR8","unstructured":"Clifford GD, Azuaje F, McSharry P et al (2006) Advanced methods and tools for ECG data analysis. Artech Hsouse Boston"},{"key":"2802_CR9","doi-asserted-by":"crossref","unstructured":"Everss-Villalba E, Melgarejo-Meseguer F, Gimeno-Blanes FJ, Sala-Pla S, Blanco-Velasco M, Rojo-\u00c1lvarez JL, Garc\u00eda-Alberola A (2016) Clinical severity of noise in ECG. In: 2016 computing in cardiology conference (CinC), pp 641\u2013644","DOI":"10.22489\/CinC.2016.187-125"},{"issue":"11","key":"2802_CR10","doi-asserted-by":"publisher","first-page":"2448","DOI":"10.3390\/s17112448","volume":"17","author":"E Everss-Villalba","year":"2017","unstructured":"Everss-Villalba E, Melgarejo-Meseguer FM, Blanco-Velasco M, Gimeno-Blanes FJ, Sala-Pla S, Rojo-\u00c1lvarez JL, Garc\u00eda-Alberola A (2017) Noise maps for quantitative and clinical severity towards long-term ECG monitoring. Sensors 17(11):2448","journal-title":"Sensors"},{"issue":"1","key":"2802_CR11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.compbiomed.2007.06.003","volume":"38","author":"M Blanco-Velasco","year":"2008","unstructured":"Blanco-Velasco M, Weng B, Barner KE (2008) ECG signal denoising and baseline wander correction based on the empirical mode decomposition. Comput Biol Med 38(1):1\u201313","journal-title":"Comput Biol Med"},{"key":"2802_CR12","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1109\/RBME.2018.2810957","volume":"11","author":"U Satija","year":"2018","unstructured":"Satija U, Ramkumar B, Manikandan MS (2018) A review of signal processing techniques for electrocardiogram signal quality assessment. IEEE Rev Biomed Eng 11:36\u201352","journal-title":"IEEE Rev Biomed Eng"},{"key":"2802_CR13","doi-asserted-by":"publisher","first-page":"60806","DOI":"10.1109\/ACCESS.2019.2912036","volume":"7","author":"HT Chiang","year":"2019","unstructured":"Chiang HT, Hsieh YY, Fu SW, Hung KH, Tsao Y, Chien SY (2019) Noise reduction in ECG signals using fully convolutional denoising autoencoders. IEEE Access 7:60806\u201360813","journal-title":"IEEE Access"},{"issue":"1","key":"2802_CR14","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1007\/BF02522855","volume":"36","author":"A Porta","year":"1998","unstructured":"Porta A, Baselli G, Lambardi F, Cerutti S, Antolini R, Del Greco M, Ravelli F, Nollo G (1998) Performance assessment of standard algorithms for dynamic RT interval measurement: comparison between R-Tapex and R-Tend approach. Med Biol Eng Comput 36(1):35\u201342","journal-title":"Med Biol Eng Comput"},{"issue":"8","key":"2802_CR15","doi-asserted-by":"publisher","first-page":"1613","DOI":"10.1109\/TBME.2014.2355135","volume":"63","author":"DP Tob\u00f3n","year":"2014","unstructured":"Tob\u00f3n DP, Falk TH, Maier M (2014) MS-QI: a modulation spectrum-based ECG quality index for telehealth applications. IEEE Trans Biomed Eng 63(8):1613\u20131622","journal-title":"IEEE Trans Biomed Eng"},{"key":"2802_CR16","doi-asserted-by":"publisher","first-page":"103316","DOI":"10.1016\/j.bspc.2021.103316","volume":"72","author":"B Tomas","year":"2022","unstructured":"Tomas B, Grabovac M, Tomas K (2022) Application of the R\u2013peak detection algorithm for locating noise in ECG signals. Biomed Sig Process Control 72:103316","journal-title":"Biomed Sig Process Control"},{"key":"2802_CR17","doi-asserted-by":"crossref","unstructured":"Redmond SJ, Lovell NH, Basilakis J, Celler BG (2008) ECG quality measures in telecare monitoring. In: 2008 30th annual international conference of the IEEE engineering in medicine and biology society, pp 2869\u20132872","DOI":"10.1109\/IEMBS.2008.4649801"},{"issue":"3","key":"2802_CR18","first-page":"832","volume":"19","author":"C Orphanidou","year":"2015","unstructured":"Orphanidou C, Bonnici T, Charlton P, Clifton D, Vallance D, Tarassenko L (2015) Signal\u2013quality indices for the electrocardiogram and photoplethysmogram: Derivation and applications to wireless monitoring. IEEE J Biomed Health Inform 19(3):832\u2013838","journal-title":"IEEE J Biomed Health Inform"},{"key":"2802_CR19","doi-asserted-by":"publisher","first-page":"727","DOI":"10.3389\/fphys.2018.00727","volume":"9","author":"Z Zhao","year":"2018","unstructured":"Zhao Z, Zhang Y (2018) SQI quality evaluation mechanism of single-lead ECG signal based on simple heuristic fusion and fuzzy comprehensive evaluation. Front Physiol 9:727","journal-title":"Front Physiol"},{"key":"2802_CR20","doi-asserted-by":"crossref","unstructured":"Varon C, Testelmans D, Buyse B, Suykens JA, Van Huffel S (2012) Robust artefact detection in long-term ECG recordings based on autocorrelation function similarity and percentile analysis. In: IEEE engineering in medicine and biology conference, pp 3151\u20133154","DOI":"10.1109\/EMBC.2012.6346633"},{"key":"2802_CR21","doi-asserted-by":"publisher","first-page":"105050","DOI":"10.1016\/j.cmpb.2019.105050","volume":"182","author":"J Moeyersons","year":"2019","unstructured":"Moeyersons J, Smets E, Morales J, Villa A, De Raedt W, Testelmans D, Buyse B, Van Hoof C, Willems R, Van Huffel S et al (2019) Artefact detection and quality assessment of ambulatory ECG signals. Comput Methods Programs Biomed 182:105050","journal-title":"Comput Methods Programs Biomed"},{"issue":"1","key":"2802_CR22","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12938-015-0053-1","volume":"14","author":"E Morgado","year":"2015","unstructured":"Morgado E, Alonso-Atienza F, Santiago-Mozos R, Barquero-P\u00e9rez \u00d3, Silva I, Ramos J, Mark R (2015) Quality estimation of the electrocardiogram using cross-correlation among leads. Biomed Eng Online 14(1):1\u201319","journal-title":"Biomed Eng Online"},{"issue":"10","key":"2802_CR23","doi-asserted-by":"publisher","first-page":"2073","DOI":"10.1007\/s11517-021-02425-8","volume":"59","author":"J Xie","year":"2021","unstructured":"Xie J, Peng L, Wei L, Gong Y, Zuo F, Wang J, Yin C, Li Y (2021) A signal quality assessment\u2013based ECG waveform delineation method used for wearable monitoring systems. Med Biol Eng Comput 59(10):2073\u20132084","journal-title":"Med Biol Eng Comput"},{"issue":"9","key":"2802_CR24","doi-asserted-by":"publisher","first-page":"1419","DOI":"10.1088\/0967-3334\/33\/9\/1419","volume":"33","author":"G Clifford","year":"2012","unstructured":"Clifford G, Behar J, Li Q, Rezek I (2012) Signal quality indices and data fusion for determining clinical acceptability of electrocardiograms. Physiol Meas 33(9):1419\u20131433","journal-title":"Physiol Meas"},{"key":"2802_CR25","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1016\/j.compbiomed.2017.06.009","volume":"87","author":"J Rodrigues","year":"2017","unstructured":"Rodrigues J, Belo D, Gamboa H (2017) Noise detection on ECG based on agglomerative clustering of morphological features. Comput Biol Med 87:322\u2013334","journal-title":"Comput Biol Med"},{"issue":"3","key":"2802_CR26","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1016\/j.cmpb.2014.09.002","volume":"117","author":"Q Li","year":"2014","unstructured":"Li Q, Rajagopalan C, Clifford GD (2014) A machine learning approach to multi-level ECG signal quality classification. Comput Methods Programs Biomed 117(3):435\u2013447","journal-title":"Comput Methods Programs Biomed"},{"issue":"3","key":"2802_CR27","doi-asserted-by":"publisher","first-page":"722","DOI":"10.1109\/JBHI.2017.2686436","volume":"22","author":"U Satija","year":"2018","unstructured":"Satija U, Ramkumar B, Manikandan MS (2018) Automated ECG noise detection and classification system for unsupervised healthcare monitoring. IEEE J Biomed Health Inform 22(3):722\u2013732","journal-title":"IEEE J Biomed Health Inform"},{"key":"2802_CR28","unstructured":"Moody GB, Muldrow WK, Mark RG (1984) A noise stress test for arrhythmia detectors. In: Computers in cardiology, vol 11, pp 381\u2013384"},{"issue":"23","key":"2802_CR29","doi-asserted-by":"publisher","first-page":"E215","DOI":"10.1161\/01.CIR.101.23.e215","volume":"101","author":"A Goldberger","year":"2000","unstructured":"Goldberger A, Amaral L, Glass L, Hausdorff J, Ivanov P, Mark R, Mietus J, Moody GB, Peng C, Stanley H (2000) Physiobank, Physiotoolkit, and Physionet: components of a new research resource for complex physiologic signals. Circulation 101(23):E215\u201320","journal-title":"Circulation"},{"key":"2802_CR30","first-page":"2951","volume":"25","author":"J Snoek","year":"2012","unstructured":"Snoek J, Larochelle H, Adams RP (2012) Practical Bayesian optimization of machine learning algorithms. Adv Neural Inf Process Syst 25:2951\u20132959","journal-title":"Adv Neural Inf Process Syst"},{"key":"2802_CR31","first-page":"2951","volume":"26","author":"K Swersky","year":"2013","unstructured":"Swersky K, Snoek J, Adams RP (2013) Multi-task Bayesian optimization. Adv Neural Inf Process Syst 26:2951\u20132959","journal-title":"Adv Neural Inf Process Syst"},{"key":"2802_CR32","volume-title":"Pattern recognition and machine learning (Information Science and Statistics)","author":"CM Bishop","year":"2006","unstructured":"Bishop CM (2006) Pattern recognition and machine learning (Information Science and Statistics). Springer-Verlag, New York"},{"key":"2802_CR33","doi-asserted-by":"publisher","DOI":"10.1007\/978-0-387-84858-7","volume-title":"The elements of statistical learning: data mining, inference and prediction","author":"T Hastie","year":"2009","unstructured":"Hastie T, Tibshirani R, Friedman J (2009) The elements of statistical learning: data mining, inference and prediction, 2nd edn. Springer, New York","edition":"2nd edn."},{"issue":"1","key":"2802_CR34","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1023\/A:1010933404324","volume":"45","author":"L Breiman","year":"2001","unstructured":"Breiman L (2001) Random forests. Mach Learn 45(1):5\u201332","journal-title":"Mach Learn"},{"issue":"1","key":"2802_CR35","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s10115-007-0114-2","volume":"14","author":"X Wu","year":"2008","unstructured":"Wu X, Kumar V, Ross Quinlan J, Ghosh J, Yang Q, Motoda H, McLachlan GJ, Ng A, Liu B, Yu PS et al (2008) Top 10 algorithms in data mining. Knowl Inf Syst 14(1):1\u201337","journal-title":"Knowl Inf Syst"},{"key":"2802_CR36","volume-title":"Deep learning","author":"I Goodfellow","year":"2016","unstructured":"Goodfellow I, Bengio Y, Courville A (2016) Deep learning. MIT Press, Cambridge"},{"issue":"10","key":"2802_CR37","doi-asserted-by":"publisher","first-page":"2402","DOI":"10.1109\/TBME.2010.2048109","volume":"57","author":"M Blanco-Velasco","year":"2010","unstructured":"Blanco-Velasco M, Cruz-Rold\u00e1n F, Godino-Llorente JI, Barner KE (2010) Nonlinear trend estimation of the ventricular repolarization segment for T-wave alternans detection. IEEE Trans Biomed Eng 57 (10):2402\u20132412","journal-title":"IEEE Trans Biomed Eng"},{"key":"2802_CR38","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-319-46162-5","volume-title":"Shalabh: introduction to statistics and data analysis","author":"C Heumann","year":"2016","unstructured":"Heumann C, Shomaker M (2016) Shalabh: introduction to statistics and data analysis. Springer, Switzerland"},{"issue":"1","key":"2802_CR39","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12864-019-6413-7","volume":"21","author":"D Chicco","year":"2020","unstructured":"Chicco D, Jurman G (2020) The advantages of the Matthews correlation coefficient (MCC) over F1 score and accuracy in binary classification evaluation. BMC Genomics 21(1):1\u201313","journal-title":"BMC Genomics"},{"key":"2802_CR40","doi-asserted-by":"crossref","unstructured":"Nu\u00f1ez Y, Lovisolo L, da Silva Mello L, Orihuela C (2022) On the interpretability of machine learning regression for path-loss prediction of millimeter-wave links. Expert Systems with Applications p 119324","DOI":"10.2139\/ssrn.4102843"},{"key":"2802_CR41","doi-asserted-by":"publisher","first-page":"107385","DOI":"10.1016\/j.knosys.2021.107385","volume":"231","author":"J Qin","year":"2021","unstructured":"Qin J, Wang C, Zou Q, Sun Y, Chen B (2021) Active learning with extreme learning machine for online imbalanced multiclass classification. Knowl-Based Syst 231:107385","journal-title":"Knowl-Based Syst"},{"issue":"10","key":"2802_CR42","doi-asserted-by":"publisher","first-page":"2797","DOI":"10.1007\/s11517-022-02633-w","volume":"60","author":"MA Ahsan","year":"2022","unstructured":"Ahsan MA, Qayyum A, Razi A, Qadir J (2022) An active learning method for diabetic retinopathy classification with uncertainty quantification. Med Biol Eng Comput 60(10):2797\u20132811","journal-title":"Med Biol Eng Comput"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-023-02802-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11517-023-02802-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-023-02802-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,9]],"date-time":"2023-08-09T22:18:22Z","timestamp":1691619502000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11517-023-02802-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4,3]]},"references-count":42,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2023,9]]}},"alternative-id":["2802"],"URL":"https:\/\/doi.org\/10.1007\/s11517-023-02802-5","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,4,3]]},"assertion":[{"value":"11 October 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 January 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 April 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"<!--Emphasis Type='Bold' removed-->Conflict of interest"}}]}}