{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T15:23:24Z","timestamp":1782228204761,"version":"3.54.5"},"reference-count":42,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2023,8,11]],"date-time":"2023-08-11T00:00:00Z","timestamp":1691712000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,8,11]],"date-time":"2023-08-11T00:00:00Z","timestamp":1691712000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2023,11]]},"DOI":"10.1007\/s11517-023-02879-y","type":"journal-article","created":{"date-parts":[[2023,8,10]],"date-time":"2023-08-10T23:02:06Z","timestamp":1691708526000},"page":"3003-3019","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Design and verification of a wearable wireless 64-channel high-resolution EEG acquisition system with wi-fi transmission"],"prefix":"10.1007","volume":"61","author":[{"given":"Chin-Teng","family":"Lin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuhling","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sheng-Fu","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kuan-Chih","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2601-3673","authenticated-orcid":false,"given":"Lun-De","family":"Liao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,8,11]]},"reference":[{"key":"2879_CR1","doi-asserted-by":"publisher","first-page":"1553","DOI":"10.1109\/Jproc.2012.2184829","volume":"100","author":"LD Liao","year":"2012","unstructured":"Liao LD et al (2012) \u201cBiosensor technologies for augmented brain-computer interfaces in the next decades,\u201d (in English). Proceedings of IEEE 100:1553\u20131566. https:\/\/doi.org\/10.1109\/Jproc.2012.2184829","journal-title":"Proceedings of IEEE"},{"issue":"2","key":"2879_CR2","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1109\/TNSRE.2006.875577","volume":"14","author":"TM Vaughan","year":"2006","unstructured":"Vaughan TM et al (2006) The Wadsworth BCI Research and Development Program: at home with BCI. IEEE Trans Neural Syst Rehabil Eng 14(2):229\u2013233. https:\/\/doi.org\/10.1109\/TNSRE.2006.875577","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"2","key":"2879_CR3","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1177\/155005941104200210","volume":"42","author":"A Bayram","year":"2011","unstructured":"Bayram A et al (2011) Simultaneous EEG\/fMRI analysis of the resonance phenomena in steady-state visual evoked responses. Clin EEG Neurosci 42(2):98\u2013106. https:\/\/doi.org\/10.1177\/155005941104200210","journal-title":"Clin EEG Neurosci"},{"issue":"7","key":"2879_CR4","doi-asserted-by":"publisher","first-page":"1167","DOI":"10.1109\/JPROC.2008.922561","volume":"96","author":"C-T Lin","year":"2008","unstructured":"Lin C-T et al (2008) Noninvasive neural prostheses using mobile and wireless EEG. Proc IEEE 96(7):1167\u20131183.\u00a0","journal-title":"Proc IEEE"},{"issue":"4","key":"2879_CR5","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1007\/s10548-009-0083-8","volume":"22","author":"C Miniussi","year":"2010","unstructured":"Miniussi C, Thut G (2010) Combining TMS and EEG offers new prospects in cognitive neuroscience. Brain Topogr 22(4):249\u2013256. https:\/\/doi.org\/10.1007\/s10548-009-0083-8","journal-title":"Brain Topogr"},{"key":"2879_CR6","doi-asserted-by":"publisher","first-page":"53","DOI":"10.3389\/fnins.2011.00053","volume":"5","author":"TO Zander","year":"2011","unstructured":"Zander TO et al (2011) A Dry EEG-System for Scientific Research and Brain-Computer Interfaces. Front Neurosci 5:53. https:\/\/doi.org\/10.3389\/fnins.2011.00053","journal-title":"Front Neurosci"},{"issue":"1","key":"2879_CR7","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1016\/j.ymeth.2006.12.008","volume":"42","author":"N Srinivasan","year":"2007","unstructured":"Srinivasan N (2007) Cognitive neuroscience of creativity: EEG based approaches. Methods 42(1):109\u2013116. https:\/\/doi.org\/10.1016\/j.ymeth.2006.12.008","journal-title":"Methods"},{"issue":"5","key":"2879_CR8","doi-asserted-by":"publisher","first-page":"1582","DOI":"10.1109\/TBME.2008.918566","volume":"55","author":"CT Lin","year":"2008","unstructured":"Lin CT et al (2008) Development of wireless brain computer interface with embedded multitask scheduling and its application on real-time driver\u2019s drowsiness detection and warning. IEEE Trans Biomed Eng 55(5):1582\u20131591. https:\/\/doi.org\/10.1109\/TBME.2008.918566","journal-title":"IEEE Trans Biomed Eng"},{"issue":"9","key":"2879_CR9","doi-asserted-by":"publisher","first-page":"1118","DOI":"10.1111\/j.1600-0501.2011.02263.x","volume":"23","author":"K Marcelis","year":"2012","unstructured":"Marcelis K, Vercruyssen M, Nicu E, Naert I, Quirynen M (2012) Sleeping vs. loaded implants, long-term observations via a retrospective analysis. Clin Oral Implants Res 23(9):1118\u20131122. https:\/\/doi.org\/10.1111\/j.1600-0501.2011.02263.x","journal-title":"Clin Oral Implants Res"},{"issue":"3","key":"2879_CR10","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1007\/s00421-008-0912-6","volume":"105","author":"YS Kim","year":"2009","unstructured":"Kim YS, Baek HJ, Kim JS, Lee HB, Choi JM, Park KS (2009) Helmet-based physiological signal monitoring system. Eur J Appl Physiol 105(3):365\u2013372. https:\/\/doi.org\/10.1007\/s00421-008-0912-6","journal-title":"Eur J Appl Physiol"},{"issue":"1","key":"2879_CR11","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1109\/TBME.2006.884649","volume":"54","author":"C Fonseca","year":"2007","unstructured":"Fonseca C et al (2007) A novel dry active electrode for EEG recording. IEEE Trans Biomed Eng 54(1):162\u2013165. https:\/\/doi.org\/10.1109\/TBME.2006.884649","journal-title":"IEEE Trans Biomed Eng"},{"issue":"6","key":"2879_CR12","doi-asserted-by":"publisher","first-page":"597","DOI":"10.1109\/TBME.2002.1001974","volume":"49","author":"P Griss","year":"2002","unstructured":"Griss P, Tolvanen-Laakso HK, Merilainen P, Stemme G (2002) Characterization of micromachined spiked biopotential electrodes. IEEE Trans Biomed Eng 49(6):597\u2013604. https:\/\/doi.org\/10.1109\/TBME.2002.1001974","journal-title":"IEEE Trans Biomed Eng"},{"issue":"8","key":"2879_CR13","doi-asserted-by":"publisher","first-page":"1909","DOI":"10.1016\/j.clinph.2008.03.034","volume":"119","author":"F Nijboer","year":"2008","unstructured":"Nijboer F et al (2008) \u201cA P300-based brain-computer interface for people with amyotrophic lateral sclerosis,\u201d ). Clin Neurophysiol 119(8):1909\u20131916","journal-title":"Clin Neurophysiol"},{"issue":"1","key":"2879_CR14","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1016\/j.jneumeth.2007.03.005","volume":"167","author":"U Hoffmann","year":"2008","unstructured":"Hoffmann U, Vesin J-M, Ebrahimi T, Diserens K (2008) An efficient P300-based brain-computer interface for disabled subjects. J Neurosci Methods 167(1):115\u2013125. https:\/\/doi.org\/10.1016\/j.jneumeth.2007.03.005","journal-title":"J Neurosci Methods"},{"key":"2879_CR15","doi-asserted-by":"publisher","unstructured":"Chan MKL, Yeung WKY., Yu JKP., Ng SSW., and Tong RKY (2022) Exploratory Study on the Clinical use of EEG for the People with Chronic Stroke and Their Correlation with the Neuropsychological Outcome. Clin EEG Neurosci, p. 15500594221074858. https:\/\/doi.org\/10.1177\/15500594221074858","DOI":"10.1177\/15500594221074858"},{"issue":"1","key":"2879_CR16","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1186\/s12873-022-00585-w","volume":"22","author":"L Sutcliffe","year":"2022","unstructured":"Sutcliffe L, Lumley H, Shaw L, Francis R, Price CI (2022) Surface electroencephalography (EEG) during the acute phase of stroke to assist with diagnosis and prediction of prognosis: a scoping review. BMC Emerg Med 22(1):29. https:\/\/doi.org\/10.1186\/s12873-022-00585-w","journal-title":"BMC Emerg Med"},{"issue":"1","key":"2879_CR17","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1186\/s12984-019-0524-x","volume":"16","author":"JVV Parr","year":"2019","unstructured":"Parr JVV, Vine SJ, Wilson MR, Harrison NR, Wood G (2019) Visual attention, EEG alpha power and T7-Fz connectivity are implicated in prosthetic hand control and can be optimized through gaze training. J Neuroeng Rehabil 16(1):52. https:\/\/doi.org\/10.1186\/s12984-019-0524-x","journal-title":"J Neuroeng Rehabil"},{"key":"2879_CR18","doi-asserted-by":"publisher","unstructured":"Tsao YC, Cheng FJ, Li YH, Liao LD (2022) An IoT-Based Smart System with an MQTT Broker for Individual Patient Vital Sign Monitoring in Potential Emergency or Prehospital Applications. Emerg Med Int,  2022. https:\/\/doi.org\/10.1155\/2022\/7245650","DOI":"10.1155\/2022\/7245650"},{"issue":"2","key":"2879_CR19","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1007\/s40846-020-00596-7","volume":"41","author":"C Chen","year":"2021","unstructured":"Chen C et al (2021) \u201cEEG-Based Anxious States Classification Using Affective BCI-Based Closed Neurofeedback System,\u201d (in English). J Med Biol Eng 41(2):155\u2013164. https:\/\/doi.org\/10.1007\/s40846-020-00596-7","journal-title":"J Med Biol Eng"},{"key":"2879_CR20","doi-asserted-by":"publisher","first-page":"1585","DOI":"10.1109\/jproc.2012.2184830","volume":"100","author":"BJ Lance","year":"2012","unstructured":"Lance BJ, Kerick SE, Ries AJ, Oie KS, McDowell K (2012) Brain-Computer Interface Technologies in the Coming Decades. Proceed IEEE 100:1585\u20131599. https:\/\/doi.org\/10.1109\/jproc.2012.2184830","journal-title":"Proceed IEEE"},{"key":"2879_CR21","doi-asserted-by":"crossref","unstructured":"Ku CJ, Wang Y, Chang CY, Wu MT, Dai ST, and Liao LD (2022) Noninvasive blood oxygen, heartbeat rate, and blood pressure parameter monitoring by photoplethysmography signals. Heliyon, p. e11698","DOI":"10.1016\/j.heliyon.2022.e11698"},{"key":"2879_CR22","doi-asserted-by":"publisher","DOI":"10.1007\/s40846-022-00766-9","author":"XY Duan","year":"2022","unstructured":"Duan XY, Guo SJ, Chen LL, Wang MG (2022) A P300 Brain-Computer Interface for Lower Limb Robot Control Based on Tactile Stimulation (in English). J Med Biol Eng. https:\/\/doi.org\/10.1007\/s40846-022-00766-9","journal-title":"J Med Biol Eng"},{"key":"2879_CR23","doi-asserted-by":"publisher","unstructured":"Wu JY, Ching CTS, Wang HMD, Liao LD (2022) Emerging Wearable Biosensor Technologies for Stress Monitoring and Their Real-World Applications. Biosensors-Basel,  12:12. https:\/\/doi.org\/10.3390\/bios12121097","DOI":"10.3390\/bios12121097"},{"key":"2879_CR24","doi-asserted-by":"publisher","unstructured":"Lin CT, Jiang WL, Chen SF, Huang KC, Liao LD (2021) Design of a Wearable Eye-Movement Detection System Based on Electrooculography Signals and Its Experimental Validation. Biosensors-Basel,  11:9. https:\/\/doi.org\/10.3390\/bios11090343","DOI":"10.3390\/bios11090343"},{"issue":"6","key":"2879_CR25","doi-asserted-by":"publisher","first-page":"5819","DOI":"10.3390\/s110605819","volume":"11","author":"LD Liao","year":"2011","unstructured":"Liao LD, Wang IJ, Chen SF, Chang JY, Lin CT (2011) \u201cDesign, Fabrication and Experimental Validation of a Novel Dry-Contact Sensor for Measuring Electroencephalography Signals without Skin Preparation,\u201d (in English). Sensors 11(6):5819\u20135834. https:\/\/doi.org\/10.3390\/s110605819","journal-title":"Sensors"},{"issue":"8","key":"2879_CR26","doi-asserted-by":"publisher","first-page":"2133","DOI":"10.1109\/TBME.2013.2248154","volume":"60","author":"SL Wu","year":"2013","unstructured":"Wu SL, Liao LD, Lu SW, Jiang WL, Chen SA, Lin CT (2013) Controlling a human-computer interface system with a novel classification method that uses electrooculography signals (in eng). IEEE Trans Biomed Eng, Research Support, Non-U.S. Gov\u2019t 60(8):2133\u201341. https:\/\/doi.org\/10.1109\/TBME.2013.2248154","journal-title":"IEEE Trans Biomed Eng, Research Support, Non-U.S. Gov't"},{"key":"2879_CR27","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1109\/RBME.2010.2084078","volume":"3","author":"YM Chi","year":"2010","unstructured":"Chi YM, Jung TP, Cauwenberghs G (2010) Dry-contact and noncontact biopotential electrodes: methodological review. IEEE Rev Biomed Eng 3:106\u2013119. https:\/\/doi.org\/10.1109\/RBME.2010.2084078","journal-title":"IEEE Rev Biomed Eng"},{"issue":"3","key":"2879_CR28","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1109\/MEMB.2010.936545","volume":"29","author":"A Casson","year":"2010","unstructured":"Casson A, Yates D, Smith S, Duncan J, Rodriguez-Villegas E (2010) Wearable Electroencephalography. IEEE Eng Med Biol Mag 29(3):44\u201356. https:\/\/doi.org\/10.1109\/MEMB.2010.936545","journal-title":"IEEE Eng Med Biol Mag"},{"issue":"4","key":"2879_CR29","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1109\/TNSRE.2010.2048579","volume":"18","author":"NA Alba","year":"2010","unstructured":"Alba NA, Sclabassi RJ, Sun M, Cui XT (2010) \u201cNovel hydrogel-based preparation-free EEG electrode,\u201d (in eng). IEEE Trans Neural Syst Rehabil Eng 18(4):415\u2013423. https:\/\/doi.org\/10.1109\/TNSRE.2010.2048579","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"2879_CR30","doi-asserted-by":"publisher","first-page":"2700307","DOI":"10.1109\/JTEHM.2014.2367518","volume":"2","author":"YH Yu","year":"2014","unstructured":"Yu YH, Lu SW, Liao LD, Lin CT (2014) Design, Fabrication, and Experimental Validation of Novel Flexible Silicon-Based Dry Sensors for Electroencephalography Signal Measurements. IEEE J Transl Eng Health Med 2:2700307. https:\/\/doi.org\/10.1109\/JTEHM.2014.2367518","journal-title":"IEEE J Transl Eng Health Med"},{"key":"2879_CR31","doi-asserted-by":"publisher","unstructured":"Sadaghiani S, Brookes MH, Baillet S (2022) Connectomics of human electrophysiology. Neuroimage,  247. https:\/\/doi.org\/10.1016\/j.neuroimage.2021.118788","DOI":"10.1016\/j.neuroimage.2021.118788"},{"key":"2879_CR32","doi-asserted-by":"publisher","unstructured":"Roberto M (2010) The electrode\u2013skin interface and optimal detection of bioelectric signals. Physiol Measure 31(10). https:\/\/doi.org\/10.1088\/0967-3334\/31\/10\/e01","DOI":"10.1088\/0967-3334\/31\/10\/e01"},{"key":"2879_CR33","doi-asserted-by":"publisher","unstructured":"Thakor NV (1999) Biopotentials and electro-physiology measurement. in The measurement, Instrumentation, and Sensors Handbook: CRC Press, ch. XI, pp 74\u20131. https:\/\/doi.org\/10.1201\/b15664-72","DOI":"10.1201\/b15664-72"},{"issue":"4","key":"2879_CR34","doi-asserted-by":"publisher","first-page":"1295","DOI":"10.1002\/hbm.25721","volume":"43","author":"P Fiedler","year":"2022","unstructured":"Fiedler P, Fonseca C, Supriyanto E, Zanow F, Haueisen J (2022) \u201cA high-density 256-channel cap for dry electroencephalography,\u201d. Hum Brain Mapp 43(4):1295\u20131308. https:\/\/doi.org\/10.1002\/hbm.25721","journal-title":"Hum Brain Mapp"},{"issue":"4","key":"2879_CR35","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1046\/j.1440-1819.2000.00729.x","volume":"54","author":"H Jing","year":"2000","unstructured":"Jing H, Takigawa M (2000) Low sampling rate induces high correlation dimension on electroencephalograms from healthy subjects. Psychiatry Clin Neurosci 54(4):407\u2013412. https:\/\/doi.org\/10.1046\/j.1440-1819.2000.00729.x","journal-title":"Psychiatry Clin Neurosci"},{"key":"2879_CR36","unstructured":"Gatzke, R. \"Biomedical Electrode Technology: Theory and Practice.\" (1974):99\u2013116."},{"key":"2879_CR37","unstructured":"J. G. Webster (ed.), Medical instrumentation: application and design. 3rd ed. New York: John Wiley & Sons, 1998."},{"key":"2879_CR38","doi-asserted-by":"publisher","unstructured":"Alharbi, A.G.; Kulkarni, J.; Desai, A.; Sim, C.-Y.-D.; Poddar, A. A Multi-Slot Two-Antenna MIMO with High Isolation for Sub-6 GHz 5G\/IEEE802.11ac\/ax\/C-Band\/X-Band Wireless and Satellite Applications. Electronics 2022(11)473. https:\/\/doi.org\/10.3390\/electronics11030473","DOI":"10.3390\/electronics11030473"},{"issue":"8","key":"2879_CR39","doi-asserted-by":"publisher","first-page":"1847","DOI":"10.1109\/TBME.2010.2043432","volume":"57","author":"H Gollee","year":"2010","unstructured":"Gollee H, Volosyak I, McLachlan IJ, Hunt KJ, Gr\u00e4ser A (2010) An SSVEP-based brain-computer interface for the control of functional electrical stimulation. IEEE Trans Biomed Eng 57(8):1847\u20131855. https:\/\/doi.org\/10.1109\/TBME.2010.2043432","journal-title":"IEEE Trans Biomed Eng"},{"issue":"1","key":"2879_CR40","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TNSRE.2010.2076364","volume":"19","author":"R Ortner","year":"2010","unstructured":"Ortner R, Allison BZ, Korisek G, Gaggl H, Pfurtscheller G (2010) An SSVEP BCI to control a hand orthosis for persons with tetraplegia. IEEE Trans Neural Syst Rehabil Eng 19(1):1\u20135. https:\/\/doi.org\/10.1109\/TNSRE.2010.2076364","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"3","key":"2879_CR41","doi-asserted-by":"publisher","first-page":"242","DOI":"10.1016\/j.biopsycho.2006.04.007","volume":"73","author":"EW Sellers","year":"2006","unstructured":"Sellers EW, Krusienski DJ, McFarland DJ, Vaughan TM, Wolpaw JR (2006) \u201cA P300 event-related potential brain-computer interface (BCI): The effects of matrix size and inter stimulus interval on performance,\u201d (in English). Biol Psychol 73(3):242\u2013252. https:\/\/doi.org\/10.1016\/j.biopsycho.2006.04.007","journal-title":"Biol Psychol"},{"issue":"10","key":"2879_CR42","doi-asserted-by":"publisher","first-page":"1490","DOI":"10.1002\/hbm.20952","volume":"31","author":"B Sadeh","year":"2010","unstructured":"Sadeh B, Podlipsky I, Zhdanov A, Yovel G (2010) Event-related potential and functional MRI measures of face-selectivity are highly correlated: a simultaneous ERP-fMRI investigation. Hum Brain Mapp 31(10):1490\u20131501. https:\/\/doi.org\/10.1002\/hbm.20952","journal-title":"Hum Brain Mapp"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-023-02879-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11517-023-02879-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-023-02879-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,18]],"date-time":"2023-10-18T01:08:44Z","timestamp":1697591324000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11517-023-02879-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8,11]]},"references-count":42,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2023,11]]}},"alternative-id":["2879"],"URL":"https:\/\/doi.org\/10.1007\/s11517-023-02879-y","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,8,11]]},"assertion":[{"value":"6 April 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 June 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 August 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that there are no conflicts of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}