{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,18]],"date-time":"2026-02-18T22:59:36Z","timestamp":1771455576788,"version":"3.50.1"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2024,6,27]],"date-time":"2024-06-27T00:00:00Z","timestamp":1719446400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,6,27]],"date-time":"2024-06-27T00:00:00Z","timestamp":1719446400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","award":["510140239"],"award-info":[{"award-number":["510140239"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","award":["510140239"],"award-info":[{"award-number":["510140239"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100002869","name":"Christian-Albrechts-Universit\u00e4t zu Kiel","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100002869","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2024,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Camptocormia, a severe flexion deformity of the spine, presents challenges in monitoring its progression outside laboratory settings. This study introduces a customized method utilizing four inertial measurement unit (IMU) sensors for continuous recording of the camptocormia angle (CA), incorporating both the consensual malleolus and perpendicular assessment methods. The setup is wearable and mobile and allows measurements outside the laboratory environment. The practicality for measuring CA across various activities is evaluated for both the malleolus and perpendicular method in a mimicked Parkinson disease posture. Multiple activities are performed by a healthy volunteer. Measurements are compared against a camera-based reference system. Results show an overall root mean squared error (RMSE) of 4.13\u00b0 for the malleolus method and 2.71\u00b0 for the perpendicular method. Furthermore, patient-specific calibration during the standing still with forward lean activity significantly reduced the RMSE to 2.45\u00b0 and 1.68\u00b0 respectively. This study presents a novel approach to continuous CA monitoring outside the laboratory setting. The proposed system is suitable as a tool for monitoring the progression of camptocormia and for the first time implements the malleolus method with IMU. It holds promise for effectively monitoring camptocormia at home.<\/jats:p>","DOI":"10.1007\/s11517-024-03149-1","type":"journal-article","created":{"date-parts":[[2024,6,27]],"date-time":"2024-06-27T03:40:43Z","timestamp":1719459643000},"page":"3637-3652","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Continuous mobile measurement of camptocormia angle using four accelerometers"],"prefix":"10.1007","volume":"62","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5248-3401","authenticated-orcid":false,"given":"K.","family":"Naderi Beni","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K.","family":"Knutzen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J. P.","family":"Kuhtz-Buschbeck","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N. G.","family":"Margraf","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4436-0804","authenticated-orcid":false,"given":"R.","family":"Rieger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,6,27]]},"reference":[{"issue":"11","key":"3149_CR1","doi-asserted-by":"publisher","first-page":"1015","DOI":"10.1093\/aje\/kwg068","volume":"157","author":"SK Van Den Eeden","year":"2003","unstructured":"Van Den Eeden SK et al (2003) Incidence of Parkinson\u2019s disease: variation by age, gender, and race\/ethnicity. Am J Epidemiol 157(11):1015\u20131022. https:\/\/doi.org\/10.1093\/aje\/kwg068","journal-title":"Am J Epidemiol"},{"key":"3149_CR2","doi-asserted-by":"publisher","unstructured":"G B D (2021) 2017 U. S. N. D. Collaborators, \u201cBurden of neurological disorders across the US from 1990-2017: a global burden of disease study. JAMA Neurol 78(2) 165\u2013176. https:\/\/doi.org\/10.1001\/jamaneurol.2020.415","DOI":"10.1001\/jamaneurol.2020.415"},{"issue":"3\u20134","key":"3149_CR3","doi-asserted-by":"publisher","first-page":"216","DOI":"10.1159\/000493484","volume":"51","author":"E Beghi","year":"2018","unstructured":"Beghi E, Giussani G (2018) Aging and the epidemiology of epilepsy. Neuroepidemiology 51(3\u20134):216\u2013223. https:\/\/doi.org\/10.1159\/000493484","journal-title":"Neuroepidemiology"},{"issue":"1","key":"3149_CR4","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1038\/s41531-020-0117-1","volume":"6","author":"W Yang","year":"2020","unstructured":"Yang W et al (2020) 2020 Current and projected future economic burden of Parkinson\u2019s disease in the U.S. npj Park Dis 6(1):15. https:\/\/doi.org\/10.1038\/s41531-020-0117-1","journal-title":"npj Park Dis"},{"issue":"5","key":"3149_CR5","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1212\/01.wnl.0000252807.38124.a3","volume":"68","author":"D Hirtz","year":"2007","unstructured":"Hirtz D, Thurman DJ, Gwinn-Hardy K, Mohamed M, Chaudhuri AR, Zalutsky R (2007) How common are the \u2018common\u2019 neurologic disorders? Neurology 68(5):326\u2013337. https:\/\/doi.org\/10.1212\/01.wnl.0000252807.38124.a3","journal-title":"Neurology"},{"key":"3149_CR6","doi-asserted-by":"publisher","unstructured":"Ou Z et al. (2021) Global trends in the incidence, prevalence, and years lived with disability of Parkinson\u2019s disease in 204 countries\/territories from 1990 to 2019. Front Public Heal 9. https:\/\/doi.org\/10.3389\/fpubh.2021.776847","DOI":"10.3389\/fpubh.2021.776847"},{"issue":"6","key":"3149_CR7","doi-asserted-by":"publisher","first-page":"538","DOI":"10.1016\/S1474-4422(11)70067-9","volume":"10","author":"KM Doherty","year":"2011","unstructured":"Doherty KM et al (2011) Postural deformities in Parkinson\u2019s disease. Lancet Neurol 10(6):538\u2013549. https:\/\/doi.org\/10.1016\/S1474-4422(11)70067-9","journal-title":"Lancet Neurol"},{"issue":"3","key":"3149_CR8","doi-asserted-by":"publisher","first-page":"485","DOI":"10.3233\/JPD-160836","volume":"6","author":"NG Margraf","year":"2016","unstructured":"Margraf NG, Wrede A, Deuschl G, Schulz-Schaeffer WJ (2016) Pathophysiological concepts and treatment of camptocormia. J Parkinsons Dis 6(3):485\u2013501. https:\/\/doi.org\/10.3233\/JPD-160836","journal-title":"J Parkinsons Dis"},{"issue":"2","key":"3149_CR9","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1136\/jnnp.2008.150011","volume":"80","author":"D Tiple","year":"2009","unstructured":"Tiple D et al (2009) Camptocormia in Parkinson disease: an epidemiological and clinical study. J Neurol Neurosurg Psychiatry 80(2):145\u2013148. https:\/\/doi.org\/10.1136\/jnnp.2008.150011","journal-title":"J Neurol Neurosurg Psychiatry"},{"issue":"3","key":"3149_CR10","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1002\/mdc3.12437","volume":"4","author":"NG Margraf","year":"2017","unstructured":"Margraf NG, Granert O, Hampel J, Wrede A, Schulz-Schaeffer WJ, Deuschl G (2017) Clinical definition of camptocormia in Parkinson\u2019s disease. Mov Disord Clin Pract 4(3):349\u2013357. https:\/\/doi.org\/10.1002\/mdc3.12437","journal-title":"Mov Disord Clin Pract"},{"key":"3149_CR11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.parkreldis.2018.06.013","volume":"52","author":"NG Margraf","year":"2018","unstructured":"Margraf NG et al (2018) Consensus for the measurement of the camptocormia angle in the standing patient. Park Relat Disord 52:1\u20135. https:\/\/doi.org\/10.1016\/j.parkreldis.2018.06.013","journal-title":"Park Relat Disord"},{"issue":"1","key":"3149_CR12","first-page":"290","volume":"46","author":"MP Murray","year":"1967","unstructured":"Murray MP (1967) Gait as a total pattern of movement. Am J Phys Med 46(1):290\u2013333","journal-title":"Am J Phys Med"},{"issue":"3","key":"3149_CR13","doi-asserted-by":"publisher","first-page":"350","DOI":"10.1016\/j.parkreldis.2012.09.008","volume":"19","author":"Y Furusawa","year":"2013","unstructured":"Furusawa Y et al (2013) Long-term effect of repeated lidocaine injections into the external oblique for upper camptocormia in Parkinson\u2019s disease. Park Relat Disord 19(3):350\u2013354. https:\/\/doi.org\/10.1016\/j.parkreldis.2012.09.008","journal-title":"Park Relat Disord"},{"issue":"1","key":"3149_CR14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41531-020-00151-w","volume":"7","author":"Y Lai","year":"2021","unstructured":"Lai Y et al (2021) Pallidal stimulation as treatment for camptocormia in Parkinson\u2019s disease. npj Park Dis 7(1):1\u20137. https:\/\/doi.org\/10.1038\/s41531-020-00151-w","journal-title":"npj Park Dis"},{"key":"3149_CR15","unstructured":"von Uexk\u00fcll T, Adler RH, Herrmann CM, K\u00f6hle K, Langewitz W, Schonecke O, Wesiack W\u00a0(2002) Psychosomatische medizin.\u00a0Urban & Fischer Verlag\/Elsevier GmbH; 6th edn"},{"key":"3149_CR16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TIM.2021.3057935","volume":"70","author":"A Rodriguez","year":"2021","unstructured":"Rodriguez A, Rabu\u00f1al JR, Pazos A, Rodr\u00edguez Sotillo A, Ezquerra N (2021) Wearable postural control system for low back pain therapy. IEEE Trans Instrum Meas 70:1\u201310. https:\/\/doi.org\/10.1109\/TIM.2021.3057935","journal-title":"IEEE Trans Instrum Meas"},{"key":"3149_CR17","doi-asserted-by":"publisher","first-page":"110080","DOI":"10.1016\/j.jbiomech.2020.110080","volume":"113","author":"RB Graham","year":"2020","unstructured":"Graham RB, Dupeyron A, van Die\u00ebn JH (2020) Between-day reliability of IMU-derived spine control metrics in patients with low back pain. J Biomech 113:110080. https:\/\/doi.org\/10.1016\/j.jbiomech.2020.110080","journal-title":"J Biomech"},{"key":"3149_CR18","doi-asserted-by":"publisher","unstructured":"Moon KS, Gombatto SP, Phan K, Ozturk Y (2022) Extraction of lumbar spine motion using a 3-IMU wearable cluster. Sensors (Basel) 23(1). https:\/\/doi.org\/10.3390\/s23010182","DOI":"10.3390\/s23010182"},{"key":"3149_CR19","doi-asserted-by":"publisher","unstructured":"Michaud F, Lugr\u00eds U, Cuadrado J (2022) Determination of the 3D human spine posture from wearable inertial sensors and a multibody model of the spine. Sensors 22(13). https:\/\/doi.org\/10.3390\/s22134796","DOI":"10.3390\/s22134796"},{"issue":"6","key":"3149_CR20","doi-asserted-by":"publisher","first-page":"2829","DOI":"10.1109\/JBHI.2023.3262164","volume":"27","author":"MS Bin Hossain","year":"2023","unstructured":"Bin Hossain MS, Guo Z, Choi H (2023) Estimation of lower extremity joint moments and 3D ground reaction forces using IMU sensors in multiple walking conditions: a deep learning approach. IEEE J Biomed Heal Informatics 27(6):2829\u20132840. https:\/\/doi.org\/10.1109\/JBHI.2023.3262164","journal-title":"IEEE J Biomed Heal Informatics"},{"issue":"2","key":"3149_CR21","doi-asserted-by":"publisher","first-page":"1616","DOI":"10.1109\/JSEN.2020.3016642","volume":"21","author":"G Saggio","year":"2021","unstructured":"Saggio G, Tombolini F, Ruggiero A (2021) Technology-based complex motor tasks assessment: a 6-DOF inertial-based system versus a gold-standard optoelectronic-based one. IEEE Sens J 21(2):1616\u20131624. https:\/\/doi.org\/10.1109\/JSEN.2020.3016642","journal-title":"IEEE Sens J"},{"issue":"17","key":"3149_CR22","doi-asserted-by":"publisher","first-page":"19407","DOI":"10.1109\/JSEN.2021.3091583","volume":"21","author":"H Chen","year":"2021","unstructured":"Chen H et al (2021) An IMU-based real-time measuring system for acetabular prosthesis implant angles in THR surgeries. IEEE Sens J 21(17):19407\u201319415. https:\/\/doi.org\/10.1109\/JSEN.2021.3091583","journal-title":"IEEE Sens J"},{"issue":"2","key":"3149_CR23","doi-asserted-by":"publisher","first-page":"1445","DOI":"10.1109\/TII.2022.3189648","volume":"19","author":"T Tan","year":"2023","unstructured":"Tan T, Wang D, Shull PB, Halilaj E (2023) IMU and smartphone camera fusion for knee adduction and knee flexion moment estimation during walking. IEEE Trans. Ind. Informatics 19(2):1445\u20131455. https:\/\/doi.org\/10.1109\/TII.2022.3189648","journal-title":"IEEE Trans. Ind. Informatics"},{"key":"3149_CR24","volume-title":"Radiologische Skizzen und Tabellen, Sch\u00e4del, Gehirn, Wirbels\u00e4ule, R\u00fcckenmark","author":"F Heuck","year":"1999","unstructured":"Heuck F, Bast BRG, Hentschel F, Voigt K (1999) Radiologische Skizzen und Tabellen, Sch\u00e4del, Gehirn, Wirbels\u00e4ule, R\u00fcckenmark. Thieme, Stuttgart"},{"key":"3149_CR25","doi-asserted-by":"publisher","unstructured":"Saito A, Kizawa S, Kobayashi Y, Miyawaki K (2020) Pose estimation by extended Kalman filter using noise covariance matrices based on sensor output. Robomech J 7(1). https:\/\/doi.org\/10.1186\/s40648-020-00185-y","DOI":"10.1186\/s40648-020-00185-y"},{"issue":"4","key":"3149_CR26","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1109\/MSP.2011.941097","volume":"28","author":"RW Schafer","year":"2011","unstructured":"Schafer RW (2011) What is a Savitzky-Golay filter? [Lecture Notes]. IEEE Signal Process Mag 28(4):111\u2013117. https:\/\/doi.org\/10.1109\/MSP.2011.941097","journal-title":"IEEE Signal Process Mag"},{"key":"3149_CR27","doi-asserted-by":"publisher","unstructured":"Wolframm H, Margraf NG, Deuschl G, Wolke R, Rieger R (2019) Measurement of camptocormia trunk flexion using a dual-sensor measurement setup. Proc. Annu Int Conf IEEE Eng Med Biol Soc EMBS, pp 3275\u20133278. https:\/\/doi.org\/10.1109\/EMBC.2019.8857212","DOI":"10.1109\/EMBC.2019.8857212"},{"key":"3149_CR28","unstructured":"Fisher CJ (2010) Using an accelerometer for inclination sensing, [Online]. Available: http:\/\/hamblen.ece.gatech.edu\/489X\/F13PROJ\/SpeedControl\/Important_files\/%0AInclination_Acce.pdf"},{"issue":"1","key":"3149_CR29","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1109\/TRO.2008.915453","volume":"24","author":"AM Dollar","year":"2008","unstructured":"Dollar AM, Herr H (2008) Lower extremity exoskeletons and active orthoses: challenges and state-of-the-art. IEEE Trans Robot 24(1):144\u2013158. https:\/\/doi.org\/10.1109\/TRO.2008.915453","journal-title":"IEEE Trans Robot"},{"issue":"5","key":"3149_CR30","doi-asserted-by":"publisher","first-page":"981","DOI":"10.1016\/j.jbiomech.2004.05.042","volume":"38","author":"G Wu","year":"2005","unstructured":"Wu G et al (2005) ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion\u2013Part II: shoulder, elbow, wrist and hand. J Biomech 38(5):981\u2013992. https:\/\/doi.org\/10.1016\/j.jbiomech.2004.05.042","journal-title":"J Biomech"},{"key":"3149_CR31","doi-asserted-by":"publisher","first-page":"594","DOI":"10.1002\/mdc3.13460","volume":"9","author":"M Tinazzi","year":"2022","unstructured":"Tinazzi M et al (2022) Task force consensus on nosology and cut-off values for axial postural abnormalities in Parkinsonism. Mov. Disord. Clin. Pract. 9:594\u2013603. https:\/\/doi.org\/10.1002\/mdc3.13460","journal-title":"Mov. Disord. Clin. Pract."},{"key":"3149_CR32","doi-asserted-by":"publisher","first-page":"1254","DOI":"10.3389\/fneur.2019.01254","volume":"10","author":"C Schlenstedt","year":"2019","unstructured":"Schlenstedt C, Gavriliuc O, Bo\u00dfe K, Wolke R, Granert O, Deuschl G, Margraf NG (2019) The effect of medication and deep brain stimulation on posture in Parkinson\u2019s disease. Front Neurol 10:1254. https:\/\/doi.org\/10.3389\/fneur.2019.01254","journal-title":"Front Neurol"},{"key":"3149_CR33","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1016\/j.parkreldis.2020.01.012","volume":"76","author":"C Schlenstedt","year":"2020","unstructured":"Schlenstedt C, Bo\u00dfe K, Gavriliuc O, Wolke R, Granert O, Deuschl G, Margraf NG (2020) Quantitative assessment of posture in healthy controls and patients with Parkinson\u2019s disease. Parkinsonism Relat Disord 76:85\u201390. https:\/\/doi.org\/10.1016\/j.parkreldis.2020.01.012","journal-title":"Parkinsonism Relat Disord"},{"issue":"2","key":"3149_CR34","doi-asserted-by":"publisher","first-page":"358","DOI":"10.1111\/sms.13851","volume":"31","author":"NP Brouwer","year":"2021","unstructured":"Brouwer NP, Yeung T, Bobbert MF, Besier TF (2021) 3D trunk orientation measured using inertial measurement units during anatomical and dynamic sports motions. Scand J Med Sci Sport 31(2):358\u2013370. https:\/\/doi.org\/10.1111\/sms.13851","journal-title":"Scand J Med Sci Sport"},{"key":"3149_CR35","doi-asserted-by":"publisher","unstructured":"Naderi Beni K, Wolke R, Finck MJ, Elfrath E, Margraf NG, Rieger R (2022) Acquisition and automated segmentation of inertia sensor data for mobile camptocormia assessment. In Proc. 44th Ann Int Conf IEEE Eng Med & Biology Soc. (EMBC), pp 105-108. https:\/\/doi.org\/10.1109\/EMBC48229.2022.9871886","DOI":"10.1109\/EMBC48229.2022.9871886"},{"issue":"20","key":"3149_CR36","doi-asserted-by":"publisher","first-page":"8525","DOI":"10.1109\/JSEN.2018.2865764","volume":"18","author":"YC Han","year":"2018","unstructured":"Han YC, Wong KI, Murray I (2018) 2-point error estimation algorithm for 3-D thigh and shank angles estimation using IMU. IEEE Sens J 18(20):8525\u20138531. https:\/\/doi.org\/10.1109\/JSEN.2018.2865764","journal-title":"IEEE Sens J"},{"key":"3149_CR37","doi-asserted-by":"publisher","unstructured":"Dang QK, Seo HG, Pham DD, and Chee Y (2019) Wearable sensor based stooped posture estimation in simulated Parkinson\u2019s disease gait. Sensors (Basel) 19(2). https:\/\/doi.org\/10.3390\/s19020223","DOI":"10.3390\/s19020223"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-024-03149-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11517-024-03149-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-024-03149-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,16]],"date-time":"2024-11-16T16:06:19Z","timestamp":1731773179000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11517-024-03149-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,27]]},"references-count":37,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2024,12]]}},"alternative-id":["3149"],"URL":"https:\/\/doi.org\/10.1007\/s11517-024-03149-1","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,6,27]]},"assertion":[{"value":"12 October 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 June 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 June 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All experimental procedures involving human subjects were approved by the institution\u2019s ethical review board under file number D 548\/19 and were conducted with informed consent according to the Declaration of Helsinki.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval and consent to participate"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}