{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T13:16:34Z","timestamp":1740143794961,"version":"3.37.3"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2024,10,3]],"date-time":"2024-10-03T00:00:00Z","timestamp":1727913600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,10,3]],"date-time":"2024-10-03T00:00:00Z","timestamp":1727913600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100014718","name":"Innovative Research Group Project of the National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["61473193"],"award-info":[{"award-number":["61473193"]}],"id":[{"id":"10.13039\/100014718","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2025,2]]},"DOI":"10.1007\/s11517-024-03206-9","type":"journal-article","created":{"date-parts":[[2024,10,3]],"date-time":"2024-10-03T04:01:42Z","timestamp":1727928102000},"page":"417-428","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparative biomechanical analysis of a conventional\/novel hip prosthetic socket"],"prefix":"10.1007","volume":"63","author":[{"given":"Yu","family":"Qian","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yunzhang","family":"Cheng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shiyao","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mingwei","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yingyu","family":"Fang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tianyi","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,10,3]]},"reference":[{"key":"3206_CR1","doi-asserted-by":"publisher","first-page":"105986","DOI":"10.1016\/j.clinbiomech.2023.105986","volume":"106","author":"CR Lanahan","year":"2023","unstructured":"Lanahan CR, Coburn KA, Hafner BJ, Ballesteros D, Allyn KJ, Friedly JL et al (2023) Short partial doffs of release\/relock sockets may effectively stabilize limb fluid volume in prosthesis users with transtibial amputation. Clin Biomech 106:105986. https:\/\/doi.org\/10.1016\/j.clinbiomech.2023.105986","journal-title":"Clin Biomech"},{"key":"3206_CR2","doi-asserted-by":"publisher","first-page":"607","DOI":"10.1097\/PXR.0000000000000157","volume":"46","author":"AL Mayo","year":"2022","unstructured":"Mayo AL, Gould S, Cimino SR, Glasford S, Harvey E, Ratto M et al (2022) A qualitative study on stakeholder perceptions of digital prosthetic socket fabrication for transtibial amputations. Prosthet Orthot Int 46:607\u2013613. https:\/\/doi.org\/10.1097\/PXR.0000000000000157","journal-title":"Prosthet Orthot Int"},{"key":"3206_CR3","doi-asserted-by":"publisher","first-page":"855","DOI":"10.1682\/JRRD.2013.06.0133","volume":"51","author":"K Ghoseiri","year":"2014","unstructured":"Ghoseiri K, Safari MR (2014) Prevalence of heat and perspiration discomfort inside prostheses: literature review. J Rehabil Res Dev 51:855\u2013868. https:\/\/doi.org\/10.1682\/JRRD.2013.06.0133","journal-title":"J Rehabil Res Dev"},{"key":"3206_CR4","doi-asserted-by":"publisher","first-page":"468","DOI":"10.1111\/ijd.13089","volume":"55","author":"E Colgecen","year":"2016","unstructured":"Colgecen E, Korkmaz M, Ozyurt K, Mermerkaya U, Kader C (2016) A clinical evaluation of skin disorders of lower limb amputation sites. Int J Dermatol 55:468\u2013472. https:\/\/doi.org\/10.1111\/ijd.13089","journal-title":"Int J Dermatol"},{"key":"3206_CR5","doi-asserted-by":"publisher","first-page":"1035","DOI":"10.1097\/PHM.0000000000000292","volume":"94","author":"ME Kralovec","year":"2015","unstructured":"Kralovec ME, Houdek MT, Andrews KL, Shives TC, Rose PS, Sim FH (2015) Prosthetic rehabilitation after hip disarticulation or hemipelvectomy. Am J Phys Med Rehabil 94:1035\u20131040. https:\/\/doi.org\/10.1097\/PHM.0000000000000292","journal-title":"Am J Phys Med Rehabil"},{"key":"3206_CR6","doi-asserted-by":"publisher","first-page":"366","DOI":"10.1589\/jpts.31.366","volume":"31","author":"K Yoshikawa","year":"2019","unstructured":"Yoshikawa K, Mutsuzaki H, Sano A, Kiguchi N, Shimizu Y, Kishimoto H et al (2019) A case of an elderly hip disarticulation amputee with rheumatoid arthritis who regained the ability to walk using a hip prosthesis. J Phys Ther Sci 31:366\u2013370. https:\/\/doi.org\/10.1589\/jpts.31.366","journal-title":"J Phys Ther Sci"},{"key":"3206_CR7","doi-asserted-by":"publisher","first-page":"4985","DOI":"10.1038\/s41598-020-61915-1","volume":"10","author":"SC Henao","year":"2020","unstructured":"Henao SC, Orozco C, Ram\u00edrez J (2020) Influence of gait cycle loads on stress distribution at the residual limb\/socket interface of transfemoral amputees: a finite element analysis. Sci Rep 10:4985. https:\/\/doi.org\/10.1038\/s41598-020-61915-1","journal-title":"Sci Rep"},{"key":"3206_CR8","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1016\/j.medengphy.2020.05.007","volume":"83","author":"Z Meng","year":"2020","unstructured":"Meng Z, Wong DW-C, Zhang M, Leung A (2020) Analysis of compression\/release stabilized transfemoral prosthetic socket by finite element modelling method. Med Eng Phys 83:123\u2013129. https:\/\/doi.org\/10.1016\/j.medengphy.2020.05.007","journal-title":"Med Eng Phys"},{"key":"3206_CR9","doi-asserted-by":"publisher","first-page":"2374","DOI":"10.1080\/09638288.2022.2093997","volume":"45","author":"TL Rich","year":"2023","unstructured":"Rich TL, Voss G, Fairhurst S, Matsumoto M, Brielmaier S, Koester K et al (2023) Feasibility testing of a novel prosthetic socket sensor system. Disabil Rehabil 45:2374\u20132381. https:\/\/doi.org\/10.1080\/09638288.2022.2093997","journal-title":"Disabil Rehabil"},{"key":"3206_CR10","doi-asserted-by":"publisher","unstructured":"Karimi MT, Kamali M, Omar H, Mostmand J (2014) Evaluation of gait performance of a hemipelvectomy amputation walking with a Canadian prosthesis. Case Rep Orthop:962980. https:\/\/doi.org\/10.1155\/2014\/962980","DOI":"10.1155\/2014\/962980"},{"key":"3206_CR11","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1589\/jpts.35.361","volume":"35","author":"T Kawaguchi","year":"2023","unstructured":"Kawaguchi T, Yamada T, Iwashita K (2023) Biomechanical gait analysis for a hip disarticulation prosthesis: power source for the swing phase of a hip disarticulation prosthetic limb. J Phys Ther Sci 35:361\u2013365. https:\/\/doi.org\/10.1589\/jpts.35.361","journal-title":"J Phys Ther Sci"},{"key":"3206_CR12","doi-asserted-by":"publisher","first-page":"434","DOI":"10.1097\/PXR.0000000000000029","volume":"45","author":"H Gholizadeh","year":"2021","unstructured":"Gholizadeh H, Baddour N, Botros M, Brannen K, Golshan F, Lemaire ED (2021) Hip disarticulation and hemipelvectomy prostheses: a review of the literature. Prosthet Orthot Int 45:434\u2013439. https:\/\/doi.org\/10.1097\/PXR.0000000000000029","journal-title":"Prosthet Orthot Int"},{"key":"3206_CR13","doi-asserted-by":"publisher","unstructured":"Zhang L, Zhu M, Shen L, Zheng F (2013) Finite element analysis of the contact interface between trans-femoral stump and prosthetic socket. Annu Int Conf IEEE Eng Med Biol Soc IEEE Eng Med Biol Soc Annu Int Conf:1270\u20133. https:\/\/doi.org\/10.1109\/EMBC.2013.6609739","DOI":"10.1109\/EMBC.2013.6609739"},{"key":"3206_CR14","doi-asserted-by":"publisher","unstructured":"van Heesewijk A, Crocombe A, Cirovic S, Taylor M, and Xu W (2019) Evaluating the effect of changes in bone geometry on the trans-femoral socket-residual limb interface using finite element analysis. In: Lhotska L, Sukupova L, Lackovi\u0107 I, Ibbott GS (eds) World Congr. Med. Phys. Biomed. Eng. 2018. Springer, Singapore, pp 587\u201391. https:\/\/doi.org\/10.1007\/978-981-10-9038-7_109","DOI":"10.1007\/978-981-10-9038-7_109"},{"key":"3206_CR15","doi-asserted-by":"publisher","first-page":"98","DOI":"10.3390\/bioengineering6040098","volume":"6","author":"MS Jamaludin","year":"2019","unstructured":"Jamaludin MS, Hanafusa A, Shinichirou Y, Agarie Y, Otsuka H, Ohnishi K (2019) Analysis of pressure distribution in transfemoral prosthetic socket for prefabrication evaluation via the finite element method. Bioeng Basel Switz 6:98. https:\/\/doi.org\/10.3390\/bioengineering6040098","journal-title":"Bioeng Basel Switz"},{"key":"3206_CR16","doi-asserted-by":"publisher","first-page":"630","DOI":"10.1016\/j.clinbiomech.2005.03.001","volume":"20","author":"X Jia","year":"2005","unstructured":"Jia X, Zhang M, Li X, Lee W (2005) A quasi-dynamic nonlinear finite element model to investigate prosthetic interface stresses during walking for trans-tibial amputees. Clin Biomech 20:630\u2013635. https:\/\/doi.org\/10.1016\/j.clinbiomech.2005.03.001","journal-title":"Clin Biomech"},{"key":"3206_CR17","doi-asserted-by":"publisher","first-page":"607","DOI":"10.1016\/s1350-4533(00)00079-5","volume":"22","author":"M Zhang","year":"2000","unstructured":"Zhang M, Roberts C (2000) Comparison of computational analysis with clinical measurement of stresses on below-knee residual limb in a prosthetic socket. Med Eng Phys 22:607\u2013612. https:\/\/doi.org\/10.1016\/s1350-4533(00)00079-5","journal-title":"Med Eng Phys"},{"key":"3206_CR18","doi-asserted-by":"publisher","first-page":"126","DOI":"10.3389\/fbioe.2018.00126","volume":"6","author":"E Ramasamy","year":"2018","unstructured":"Ramasamy E, Avci O, Dorow B, Chong S, Gizzi L, Steidle G (2018) An efficient modelling-simulation-analysis workflow to investigate stump-socket interaction using patient-specific, three-dimensional, continuum-mechanical, finite element residual limb models. Front Bioeng Biotechnol 6:126. https:\/\/doi.org\/10.3389\/fbioe.2018.00126","journal-title":"Front Bioeng Biotechnol"},{"key":"3206_CR19","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1177\/0954411915624452","volume":"230","author":"Y Sang","year":"2016","unstructured":"Sang Y, Li X, Luo Y (2016) Biomechanical design considerations for transradial prosthetic interface: a review. Proc Inst Mech Eng [H] 230:239\u2013250. https:\/\/doi.org\/10.1177\/0954411915624452","journal-title":"Proc Inst Mech Eng [H]"},{"key":"3206_CR20","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1109\/TNSRE.2003.810436","volume":"11","author":"E T\u00f6n\u00fck","year":"2003","unstructured":"T\u00f6n\u00fck E, Silver-Thorn MB (2003) Nonlinear elastic material property estimation of lower extremity residual limb tissues. IEEE Trans Neural Syst Rehabil Eng Publ IEEE Eng Med Biol Soc 11:43\u201353. https:\/\/doi.org\/10.1109\/TNSRE.2003.810436","journal-title":"IEEE Trans Neural Syst Rehabil Eng Publ IEEE Eng Med Biol Soc"},{"key":"3206_CR21","doi-asserted-by":"publisher","first-page":"100731","DOI":"10.1016\/j.irbm.2022.07.002","volume":"44","author":"MH Wang","year":"2023","unstructured":"Wang MH, Nong QJ, Qian Y, Huang YH, Wang YH, Yu HL (2023) Design of adjustable frame-type prosthetic socket for lower limb. IRBM 44:100731. https:\/\/doi.org\/10.1016\/j.irbm.2022.07.002","journal-title":"IRBM"},{"key":"3206_CR22","doi-asserted-by":"publisher","first-page":"1227","DOI":"10.1007\/s11517-017-1758-z","volume":"56","author":"JC Cagle","year":"2017","unstructured":"Cagle JC, Reinhall PG, Allyn KJ, McLean J, Hinrichs P, Hafner BJ et al (2017) A finite element model to assess transtibial prosthetic sockets with elastomeric liners. Med Biol Eng Comput 56:1227\u20131240. https:\/\/doi.org\/10.1007\/s11517-017-1758-z","journal-title":"Med Biol Eng Comput"},{"key":"3206_CR23","doi-asserted-by":"publisher","first-page":"5016","DOI":"10.3390\/s21155016","volume":"21","author":"S-T Ko","year":"2021","unstructured":"Ko S-T, Asplund F, Zeybek B (2021) A scoping review of pressure measurements in prosthetic sockets of transfemoral amputees during ambulation: key considerations for sensor design. Sensors 21:5016. https:\/\/doi.org\/10.3390\/s21155016","journal-title":"Sensors"},{"key":"3206_CR24","doi-asserted-by":"publisher","unstructured":"Wang F, Kim K, Wen S, Wang Y, Wu C (2011) Study of gait symmetry quantification and its application to intelligent prosthetic leg development. 2011 IEEE Int. Conf. Robot. Biomim. pp 1361\u20136. https:\/\/doi.org\/10.1109\/ROBIO.2011.6181478","DOI":"10.1109\/ROBIO.2011.6181478"},{"key":"3206_CR25","doi-asserted-by":"publisher","first-page":"282","DOI":"10.1016\/j.gaitpost.2018.04.030","volume":"63","author":"ZA Schafer","year":"2018","unstructured":"Schafer ZA, Perry JL, Vanicek N (2018) A personalised exercise programme for individuals with lower limb amputation reduces falls and improves gait biomechanics: a block randomised controlled trial. Gait Posture 63:282\u2013289. https:\/\/doi.org\/10.1016\/j.gaitpost.2018.04.030","journal-title":"Gait Posture"},{"key":"3206_CR26","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1097\/PHM.0b013e3181e71d90","volume":"89","author":"DC Morgenroth","year":"2010","unstructured":"Morgenroth DC, Orendurff MS, Shakir A, Segal A, Shofer J, Czerniecki JM (2010) The relationship between lumbar spine kinematics during gait and low-back pain in transfemoral amputees. Am J Phys Med Rehabil 89:635\u2013643. https:\/\/doi.org\/10.1097\/PHM.0b013e3181e71d90","journal-title":"Am J Phys Med Rehabil"},{"key":"3206_CR27","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1080\/03093640500217208","volume":"29","author":"A Fern\u00e1ndez","year":"2005","unstructured":"Fern\u00e1ndez A, Formigo J (2005) Are Canadian prostheses used? A long-term experience. Prosthet Orthot Int 29:177\u2013181. https:\/\/doi.org\/10.1080\/03093640500217208","journal-title":"Prosthet Orthot Int"},{"issue":"1","key":"3206_CR28","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1097\/PXR.0000000000000226","volume":"48","author":"A Saif","year":"2024","unstructured":"Saif A, Francis R, Sullivan J, Sedki I (2024) Factors affecting successful prosthetic use after hemipelvectomy and hip disarticulation amputations: five-year experience from a tertiary prosthetic rehabilitation center. Prosthet Orthot Int 48(1):20\u201324. https:\/\/doi.org\/10.1097\/PXR.0000000000000226","journal-title":"Prosthet Orthot Int"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-024-03206-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11517-024-03206-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-024-03206-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,21]],"date-time":"2025-01-21T06:17:15Z","timestamp":1737440235000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11517-024-03206-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,3]]},"references-count":28,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025,2]]}},"alternative-id":["3206"],"URL":"https:\/\/doi.org\/10.1007\/s11517-024-03206-9","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"type":"print","value":"0140-0118"},{"type":"electronic","value":"1741-0444"}],"subject":[],"published":{"date-parts":[[2024,10,3]]},"assertion":[{"value":"30 June 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 September 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 October 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All procedures were performed in compliance with relevant laws and institutional guidelines and have been approved by the appropriate institutional committee (Reference Number: ZYXM1-04\u2013420300197109053525).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}