{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,28]],"date-time":"2026-02-28T15:36:05Z","timestamp":1772292965393,"version":"3.50.1"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2024,12,16]],"date-time":"2024-12-16T00:00:00Z","timestamp":1734307200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,12,16]],"date-time":"2024-12-16T00:00:00Z","timestamp":1734307200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["52035012"],"award-info":[{"award-number":["52035012"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100012226","name":"Fundamental Research Funds for the Central Universities","doi-asserted-by":"publisher","award":["2682023ZTPY052"],"award-info":[{"award-number":["2682023ZTPY052"]}],"id":[{"id":"10.13039\/501100012226","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2025,4]]},"DOI":"10.1007\/s11517-024-03257-y","type":"journal-article","created":{"date-parts":[[2024,12,16]],"date-time":"2024-12-16T04:27:54Z","timestamp":1734323274000},"page":"1189-1200","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["The influence of PEEK acetabular shell on the mechanical stability of total hip replacements under gait loading and motion"],"prefix":"10.1007","volume":"63","author":[{"given":"Hongxing","family":"Shi","sequence":"first","affiliation":[]},{"given":"Xiaogang","family":"Zhang","sequence":"additional","affiliation":[]},{"given":"Zhenxian","family":"Chen","sequence":"additional","affiliation":[]},{"given":"Yali","family":"Zhang","sequence":"additional","affiliation":[]},{"given":"Zhongmin","family":"Jin","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2024,12,16]]},"reference":[{"issue":"2","key":"3257_CR1","first-page":"248","volume":"39","author":"W Cui","year":"2019","unstructured":"Cui W, Zhang Y, Wang Z et al (2019) Review of the artificial hip and knee wear testing standards and simulation testing machines. Tribology 39(2):248\u2013258","journal-title":"Tribology"},{"key":"3257_CR2","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1007\/978-3-031-26415-3_2","volume-title":"Managing cardiovascular risk in elective total joint arthroplasty","author":"TL Bernasek","year":"2023","unstructured":"Bernasek TL, Gill M, Herekar R et al (2023) Total joint replacement, contemporary concepts. In: Harrison EE, Ho NH (eds) Managing cardiovascular risk in elective total joint arthroplasty. Springer International Publishing, Cham, pp 7\u201322 (ISBN 978-3-031-26414-6)"},{"issue":"21","key":"3257_CR3","first-page":"1453","volume":"40","author":"YY Bian","year":"2020","unstructured":"Bian YY, Cheng KY, Chang X et al (2020) Reports and analysis of amount of hip and knee arthroplasty in China from 2011 to 2019. Chin J Orthop 40(21):1453\u20131460","journal-title":"Chin J Orthop"},{"key":"3257_CR4","doi-asserted-by":"publisher","DOI":"10.1142\/S0219519424500192","author":"M Kalayarasan","year":"2024","unstructured":"Kalayarasan M, Dhanabal P, Shankar S et al (2024) Unveiling the influence of one-leg stance and standing up from a chair on human hip joint prosthesis using finite element concepts. J Mech Med Biol. https:\/\/doi.org\/10.1142\/S0219519424500192","journal-title":"J Mech Med Biol"},{"issue":"4","key":"3257_CR5","doi-asserted-by":"publisher","first-page":"551","DOI":"10.1302\/0301-620X.73B4.2071634","volume":"73","author":"M Jasty","year":"1991","unstructured":"Jasty M, Maloney W, Bragdon C et al (1991) The Initiation of failure in cemented femoral components of hip arthroplasties. J Bone Joint Surg 73(4):551\u2013558","journal-title":"J Bone Joint Surg"},{"key":"3257_CR6","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1097\/00003086-198607000-00023","volume":"208","author":"RM Pilliar","year":"1986","unstructured":"Pilliar RM, Lee JM, Maniatopoulos C et al (1986) Observations on the effect of movement on bone ingrowth into porous-surfaced implants. Clin Orthop Relat Res 208:108\u2013113","journal-title":"Clin Orthop Relat Res"},{"issue":"3","key":"3257_CR7","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1016\/S0883-5403(99)90063-3","volume":"14","author":"H Kienapfel","year":"1999","unstructured":"Kienapfel H, Sprey C, Wilke A et al (1999) Implant fixation by bone ingrowth. J Arthroplast 14(3):355\u2013368","journal-title":"J Arthroplast"},{"issue":"1","key":"3257_CR8","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1186\/s42836-022-00156-1","volume":"5","author":"I Patel","year":"2023","unstructured":"Patel I, Nham F, Zalikha AK et al (2023) Epidemiology of total hip arthroplasty: demographics, comorbidities and outcomes. Arthroplasty 5(1):2","journal-title":"Arthroplasty"},{"issue":"6","key":"3257_CR9","doi-asserted-by":"publisher","first-page":"1717","DOI":"10.1007\/s11517-024-03023-0","volume":"62","author":"CM Saviour","year":"2024","unstructured":"Saviour CM, Mathai B, Gupta S (2024) Mechanobiochemical bone remodelling around an uncemented acetabular component: influence of bone orthotropy. Med Biol Eng Compu 62(6):1717\u20131732","journal-title":"Med Biol Eng Compu"},{"key":"3257_CR10","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1007\/s12178-023-09839-x","volume":"16","author":"A Arshi","year":"2023","unstructured":"Arshi A, Hughes AJ, Robin JX et al (2023) Return to sport after hip and knee arthroplasty: counseling the patient on resuming an active lifestyle. Curr Rev Musculoskelet Med 16:329\u2013337","journal-title":"Curr Rev Musculoskelet Med"},{"issue":"1","key":"3257_CR11","doi-asserted-by":"publisher","first-page":"493","DOI":"10.1007\/s00402-023-05058-8","volume":"144","author":"Y Afghanyar","year":"2024","unstructured":"Afghanyar Y, Moeller JH, Wunderlich F et al (2024) An isoelastic monoblock cup versus a modular metal-back cup: a matched-pair analysis of clinical and radiological results using Einzel-Bild-Rontgen-Analyse software. Arch Orthop Trauma Surg 144(1):493\u2013500","journal-title":"Arch Orthop Trauma Surg"},{"key":"3257_CR12","doi-asserted-by":"publisher","first-page":"719","DOI":"10.1016\/j.jbiomech.2011.11.042","volume":"45","author":"AS Dickinson","year":"2012","unstructured":"Dickinson AS, Taylor AC, Browne M (2012) The influence of acetabular cup material on pelvis cortex surface strains, measured using digital image correlation. J Biomech 45:719\u2013723","journal-title":"J Biomech"},{"issue":"1","key":"3257_CR13","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1080\/10402004.2022.2140727","volume":"66","author":"AT Alpkaya","year":"2023","unstructured":"Alpkaya AT, Mihcin S (2023) The computational approach to predicting wear: comparison of wear performance of CFR-PEEK and XLPE liners in total hip replacement. Tribol Trans 66(1):59\u201372","journal-title":"Tribol Trans"},{"issue":"6","key":"3257_CR14","doi-asserted-by":"publisher","first-page":"1372","DOI":"10.3390\/ma13061372","volume":"13","author":"D Vogel","year":"2020","unstructured":"Vogel D, Klimek M, Saemann M et al (2020) Influence of the acetabular cup material on the shell deformation and strain distribution in the adjacent bone\u2014a finite element analysis. Materials 13(6):1372","journal-title":"Materials"},{"key":"3257_CR15","doi-asserted-by":"publisher","first-page":"104006","DOI":"10.1016\/j.medengphy.2023.104006","volume":"117","author":"AT Alpkaya","year":"2023","unstructured":"Alpkaya AT, Mihcin S (2023) Dynamic computational wear model of PEEK-on-XLPE bearing couple in total hip replacements. Med Eng Phys 117:104006","journal-title":"Med Eng Phys"},{"key":"3257_CR16","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1302\/0301-620X.89B2.18634","volume":"89","author":"YH Kim","year":"2007","unstructured":"Kim YH, Yoon SH, Kim JS (2007) Changes in the bone mineral density in the acetabulum and proximal femur after cementless total hip replacement: alumina-on-alumina versus alumina-on-polyethylene articulation. J Bone Jt Surg 89:174\u2013179","journal-title":"J Bone Jt Surg"},{"issue":"1","key":"3257_CR17","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1016\/j.clinbiomech.2010.08.015","volume":"26","author":"A Hothan","year":"2011","unstructured":"Hothan A, Huber G, Weiss C et al (2011) Deformation characteristics and eigenfrequencies of press-fit acetabular shells. Clin Biomech 26(1):46\u201351","journal-title":"Clin Biomech"},{"key":"3257_CR18","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1097\/00003086-199201000-00018","volume":"274","author":"EW Morscher","year":"1992","unstructured":"Morscher EW (1992) Current status of acetabular fixation in primary total hip arthroplasty. Clin Orthop Relat Res 274:172\u2013193","journal-title":"Clin Orthop Relat Res"},{"issue":"2","key":"3257_CR19","doi-asserted-by":"publisher","first-page":"299","DOI":"10.1243\/095441105X69150","volume":"220","author":"ZM Jin","year":"2006","unstructured":"Jin ZM, Meakins S, Morlock MM et al (2006) Deformation of press-fitted metallic resurfacing shells. Part 1: experimental simulation. Proc Inst Mech Eng H 220(2):299\u2013309","journal-title":"Proc Inst Mech Eng H"},{"key":"3257_CR20","unstructured":"Pengyu L (2021) The finite element analysis and research of reconstruction of Paprosky III bone defects [D]. Southwest Jiaotong University"},{"key":"3257_CR21","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1016\/1350-4533(95)97314-F","volume":"17","author":"JY Rho","year":"1995","unstructured":"Rho JY, Hobatho MC, Ashman RB (1995) Relations of mechanical properties to density and CT numbers in human bone. Med Eng Phys 17:347\u2013355","journal-title":"Med Eng Phys"},{"issue":"10","key":"3257_CR22","doi-asserted-by":"publisher","first-page":"2318","DOI":"10.1016\/j.jbiomech.2006.10.038","volume":"40","author":"AD Speirs","year":"2007","unstructured":"Speirs AD, Heller MO, Duda GN, Taylor WR (2007) Physiologically based boundary conditions in finite element modelling. J Biomech 40(10):2318\u20132323","journal-title":"J Biomech"},{"issue":"2","key":"3257_CR23","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1007\/s00776-012-0340-7","volume":"18","author":"P Goebel","year":"2013","unstructured":"Goebel P, Kluess D, Wieding J et al (2013) The influence of head diameter and wall thickness on deformations of metallic acetabular press-fit shells and UHMWPE liners: a finite element analysis. J Orthop Sci 18(2):264\u2013270","journal-title":"J Orthop Sci"},{"key":"3257_CR24","doi-asserted-by":"publisher","unstructured":"Vogel D, Klimek M, Saemann M et al (2020) Influence of the acetabular shell material on the shell deformation and strain distribution in the adjacent bone-a finite element analysis. Materials 13(6). https:\/\/doi.org\/10.3390\/ma13061372","DOI":"10.3390\/ma13061372"},{"key":"3257_CR25","doi-asserted-by":"publisher","first-page":"e0155612","DOI":"10.1371\/journal.pone.0155612","volume":"11","author":"G Bergmann","year":"2016","unstructured":"Bergmann G, Bender A, Dymke J et al (2016) Standardized loads acting in hip implants. PLoS ONE 11:e0155612","journal-title":"PLoS ONE"},{"issue":"3","key":"3257_CR26","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1016\/S0021-9290(01)00215-9","volume":"35","author":"SH Teoh","year":"2002","unstructured":"Teoh SH, Chan WH, Thampuran R (2002) An elasto-plastic finite element model for polyethylene wear in total hip arthroplasty. J Biomech 35(3):323\u2013330","journal-title":"J Biomech"},{"issue":"4","key":"3257_CR27","doi-asserted-by":"publisher","first-page":"468","DOI":"10.5301\/HIP.2011.8573","volume":"21","author":"CA Yahia","year":"2011","unstructured":"Yahia CA, Diwanji S, Ganapati M et al (2011) Supra acetabular bone mineral density measurements after hip resurfacing arthroplasty at short term follow up. Hip Int 21(4):468\u2013474","journal-title":"Hip Int"},{"key":"3257_CR28","doi-asserted-by":"publisher","unstructured":"Celik E, Alemdar F, Bati M et al Mechanical investigation for the use of polylactic acid in total hip arthroplasty using FEM analysis. In: Hadamus A, Piszczatowski S, Syczewska M, B\u0142a\u017ckiewicz M (eds) Biomechanics in medicine, sport and biology. Biomechanics 2021. Lecture notes in networks and systems, vol 328. Springer, Cham. https:\/\/doi.org\/10.1007\/978-3-030-86297-8_2","DOI":"10.1007\/978-3-030-86297-8_2"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-024-03257-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11517-024-03257-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-024-03257-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,29]],"date-time":"2025-03-29T20:51:22Z","timestamp":1743281482000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11517-024-03257-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,16]]},"references-count":28,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025,4]]}},"alternative-id":["3257"],"URL":"https:\/\/doi.org\/10.1007\/s11517-024-03257-y","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,16]]},"assertion":[{"value":"6 August 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 November 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 December 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}