{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T23:39:46Z","timestamp":1773358786077,"version":"3.50.1"},"reference-count":107,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2025,1,28]],"date-time":"2025-01-28T00:00:00Z","timestamp":1738022400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,1,28]],"date-time":"2025-01-28T00:00:00Z","timestamp":1738022400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100004377","name":"The Hong Kong Polytechnic University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100004377","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2025,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>Finite element analysis has become indispensable for biomechanical research on clavicle fractures. This review summarized evidence regarding configurations and applications of finite element analysis in clavicle fracture fixation. Seventeen articles involving 22 clavicles were synthesized from CINAHL, Embase, IEEE Xplore, PubMed, Scopus, and Web of Science databases. Most studies investigated midshaft transverse closed fractures by reconstructing intact models from CT scans and simulating fractures through gap creation. Common loading schemes included axial compression, distal torsion, and inferior bending. The primary objective was comparing different implant designs\/placements on construct stiffness, von Mises stress, and fracture site micro-motion. Our review suggested a preference for plate fixation, particularly with anterior placement, for midshaft transverse fractures. However, limited fracture types studied constrain comprehensive recommendations. Additionally, the review highlighted discrepancies between finite element and clinical studies, emphasizing the need for improved modeling of physiological conditions. Future research should focus on developing a comprehensive database of finite element models to test various implant options and placements under common loading schemes, bridging the gap between biomechanical simulations and clinical outcomes.<\/jats:p>\n          <jats:p>\n            <jats:bold>Graphical Abstract<\/jats:bold>\n          <\/jats:p>","DOI":"10.1007\/s11517-025-03294-1","type":"journal-article","created":{"date-parts":[[2025,1,28]],"date-time":"2025-01-28T15:53:01Z","timestamp":1738079581000},"page":"1585-1607","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Finite element modeling of clavicle fracture fixations: a systematic scoping review"],"prefix":"10.1007","volume":"63","author":[{"given":"Yi","family":"Zheng","sequence":"first","affiliation":[]},{"given":"Jing","family":"Li","sequence":"additional","affiliation":[]},{"given":"Andy Yiu-Chau","family":"Tam","sequence":"additional","affiliation":[]},{"given":"Timothy Tin-Yan","family":"Lee","sequence":"additional","affiliation":[]},{"given":"Yinghu","family":"Peng","sequence":"additional","affiliation":[]},{"given":"James Chung-Wai","family":"Cheung","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8805-1157","authenticated-orcid":false,"given":"Duo Wai-Chi","family":"Wong","sequence":"additional","affiliation":[]},{"given":"Ming","family":"Ni","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2025,1,28]]},"reference":[{"key":"3294_CR1","doi-asserted-by":"publisher","first-page":"S25","DOI":"10.1016\/j.jcot.2019.07.016","volume":"11","author":"R Moverley","year":"2020","unstructured":"Moverley R, Little N, Gulihar A, Singh B (2020) Current concepts in the management of clavicle fractures. J Clin Ortho Trauma 11:S25\u2013S30","journal-title":"J Clin Ortho Trauma"},{"issue":"5","key":"3294_CR2","doi-asserted-by":"publisher","first-page":"954","DOI":"10.1016\/j.jcot.2019.01.019","volume":"10","author":"SF DeFroda","year":"2019","unstructured":"DeFroda SF, Lemme N, Kleiner J, Gil J, Owens BD (2019) Incidence and mechanism of injury of clavicle fractures in the NEISS database: athletic and non athletic injuries. J Clin Ortho Trauma 10(5):954\u2013958","journal-title":"J Clin Ortho Trauma"},{"issue":"10","key":"3294_CR3","doi-asserted-by":"publisher","first-page":"232596712211265","DOI":"10.1177\/23259671221126553","volume":"10","author":"J Twomey-Kozak","year":"2022","unstructured":"Twomey-Kozak J, Whitlock KG, O\u2019Donnell JA, Klifto CS, Anakwenze O (2022) Epidemiology of sports-related clavicle fractures in the United States: injuries from 2015 to 2019. Orthop J Sports Med 10(10):23259671221126550","journal-title":"Orthop J Sports Med"},{"issue":"9","key":"3294_CR4","doi-asserted-by":"publisher","first-page":"901","DOI":"10.1080\/13696998.2019.1620245","volume":"22","author":"M Putnam","year":"2019","unstructured":"Putnam M, Vanderkarr M, Nandwani P, Holy CE, Chitnis AS (2019) Surgical treatment, complications, and reimbursement among patients with clavicle fracture and acromioclavicular dislocations: a US retrospective claims database analysis. J Med Econ 22(9):901\u2013908","journal-title":"J Med Econ"},{"key":"3294_CR5","doi-asserted-by":"publisher","first-page":"560","DOI":"10.1186\/s12891-020-03557-y","volume":"21","author":"ED Tutuhatunewa","year":"2020","unstructured":"Tutuhatunewa ED, Stevens M, Dams OC, van Son J, Louhanepessy RD, Krabbe PF, Postma MJ, Diercks RL (2020) Exploring patient satisfaction after operative and nonoperative treatment for midshaft clavicle fractures: a focus group analysis. BMC Musculoskelet Disord 21:560","journal-title":"BMC Musculoskelet Disord"},{"key":"3294_CR6","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1016\/j.jcot.2020.08.020","volume":"13","author":"KM Amer","year":"2021","unstructured":"Amer KM, Congiusta DV, Suri P, Choudhry A, Otero K, Adams M (2021) Clavicle fractures: associated trauma and morbidity. J Clin Ortho Trauma 13:53\u201356","journal-title":"J Clin Ortho Trauma"},{"issue":"2","key":"3294_CR7","doi-asserted-by":"publisher","first-page":"163","DOI":"10.4103\/jotr.jotr_33_20","volume":"13","author":"S Ahmad","year":"2021","unstructured":"Ahmad S, Singh NK (2021) A clinical study of the management of fracture shaft of clavicle by different modalities. J Ortho Traumatol Rehab 13(2):163\u2013168","journal-title":"J Ortho Traumatol Rehab"},{"issue":"6","key":"3294_CR8","doi-asserted-by":"publisher","first-page":"540","DOI":"10.1302\/1863-2548.15.210139","volume":"15","author":"A Sisman","year":"2021","unstructured":"Sisman A, Poyraz C, Cicek AC, Kor S, Cullu E (2021) Are there any differences between the shoulder-arm sling and figure-of-eight bandage in the conservative treatment of paediatric clavicle fractures? J Child Orthop 15(6):540\u2013545","journal-title":"J Child Orthop"},{"key":"3294_CR9","doi-asserted-by":"publisher","first-page":"519","DOI":"10.1007\/s00068-019-01122-4","volume":"46","author":"H Frima","year":"2020","unstructured":"Frima H, van Heijl M, Michelitsch C, van Der Meijden O, Beeres FJ, Houwert RM, Sommer C (2020) Clavicle fractures in adults; current concepts. Eur J Trauma Emerg Surg 46:519\u2013529","journal-title":"Eur J Trauma Emerg Surg"},{"issue":"5","key":"3294_CR10","doi-asserted-by":"publisher","first-page":"759","DOI":"10.3390\/jpm12050759","volume":"12","author":"C Biz","year":"2022","unstructured":"Biz C, Scucchiari D, Pozzuoli A, Belluzzi E, Bragazzi NL, Berizzi A, Ruggieri P (2022) Management of displaced midshaft clavicle fractures with figure-of-eight bandage: the impact of residual shortening on shoulder function. J Person Med 12(5):759","journal-title":"J Person Med"},{"issue":"7","key":"3294_CR11","doi-asserted-by":"publisher","first-page":"2793","DOI":"10.1007\/s00590-023-03541-x","volume":"33","author":"MG Rizzo","year":"2023","unstructured":"Rizzo MG, Markowitz MI, Minaie A, Greif D, Lee D, Allegra P, Mu\u00f1oz J (2023) The 50 most influential publications in clavicle fractures. Eur J Orthop Surg Traumatol 33(7):2793\u20132803","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"1","key":"3294_CR12","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1186\/s12891-022-05075-5","volume":"23","author":"S Wolf","year":"2022","unstructured":"Wolf S, Chitnis AS, Manoranjith A, Vanderkarr M, Plaza JQ, Gador LV, Holy CE, Sparks C, Lambert SM (2022) Surgical treatment, complications, reoperations, and healthcare costs among patients with clavicle fracture in England. BMC Musculoskelet Disord 23(1):135","journal-title":"BMC Musculoskelet Disord"},{"issue":"13","key":"3294_CR13","doi-asserted-by":"publisher","first-page":"1119","DOI":"10.2106\/JBJS.M.00607","volume":"96","author":"T Leroux","year":"2014","unstructured":"Leroux T, Wasserstein D, Henry P, Khoshbin A, Dwyer T, Ogilvie-Harris D, Mahomed N, Veillette C (2014) Rate of and risk factors for reoperations after open reduction and internal fixation of midshaft clavicle fractures: a population-based study in Ontario. Canada JBJS 96(13):1119\u20131125","journal-title":"Canada JBJS"},{"issue":"7","key":"3294_CR14","doi-asserted-by":"publisher","first-page":"504","DOI":"10.1097\/01.bot.0000172287.44278.ef","volume":"19","author":"M Zlowodzki","year":"2005","unstructured":"Zlowodzki M, Zelle BA, Cole PA, Jeray K, McKee MD (2005) Treatment of acute midshaft clavicle fractures: systematic review of 2144 fractures: on behalf of the Evidence-Based Orthopaedic Trauma Working Group. J Orthop Trauma 19(7):504\u2013507","journal-title":"J Orthop Trauma"},{"issue":"10","key":"3294_CR15","doi-asserted-by":"publisher","first-page":"e498","DOI":"10.1016\/j.jse.2022.03.016","volume":"31","author":"SJ Charles","year":"2022","unstructured":"Charles SJ, Chen SR, Mittwede P, Rai A, Moloney G, Sabzevari S, Lin A (2022) Risk factors for complications and reoperation following operative management of displaced midshaft clavicle fractures. J Shoulder Elbow Surg 31(10):e498\u2013e506","journal-title":"J Shoulder Elbow Surg"},{"key":"3294_CR16","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1186\/s12891-020-03256-8","volume":"21","author":"P Hoogervorst","year":"2020","unstructured":"Hoogervorst P, Van Dam T, Verdonschot N, Hannink G (2020) Functional outcomes and complications of intramedullary fixation devices for midshaft clavicle fractures: a systematic review and meta-analysis. BMC Musculoskelet Disord 21:395","journal-title":"BMC Musculoskelet Disord"},{"issue":"5","key":"3294_CR17","doi-asserted-by":"publisher","first-page":"e125","DOI":"10.1016\/j.jse.2015.11.065","volume":"25","author":"RA Navarro","year":"2016","unstructured":"Navarro RA, Gelber JD, Harrast JJ, Seiler JG III, Jackson KR, Garcia IA (2016) Frequency and complications after operative fixation of clavicular fractures. J Shoulder Elbow Surg 25(5):e125\u2013e129","journal-title":"J Shoulder Elbow Surg"},{"issue":"5","key":"3294_CR18","doi-asserted-by":"publisher","first-page":"739","DOI":"10.1016\/j.jse.2015.09.029","volume":"25","author":"M Naimark","year":"2016","unstructured":"Naimark M, Dufka FL, Han R, Sing DC, Toogood P, Ma CB, Zhang AL, Feeley BT (2016) Plate fixation of midshaft clavicular fractures: patient-reported outcomes and hardware-related complications. J Shoulder Elbow Surg 25(5):739\u2013746","journal-title":"J Shoulder Elbow Surg"},{"key":"3294_CR19","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1186\/s10195-018-0492-0","volume":"19","author":"MM Alzahrani","year":"2018","unstructured":"Alzahrani MM, Cota A, Alkhelaifi K, Aleidan A, Berry G, Reindl R, Harvey E (2018) Are clinical outcomes affected by type of plate used for management of mid-shaft clavicle fractures? J Orthop Traumatol 19:8","journal-title":"J Orthop Traumatol"},{"issue":"6","key":"3294_CR20","doi-asserted-by":"publisher","first-page":"2331","DOI":"10.1007\/s00590-022-03428-3","volume":"33","author":"MA Sinkler","year":"2023","unstructured":"Sinkler MA, Wang M, Kuo A, Furdock RJ, McMellen CJ, Boes K, Ochenjele G (2023) Anterior and superior plate positions in diaphyseal clavicle fractures produce similar patient outcomes. Eur J Orthop Surg Traumatol 33(6):2331\u20132336","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"7","key":"3294_CR21","doi-asserted-by":"publisher","first-page":"e898","DOI":"10.3928\/01477447-20130624-20","volume":"36","author":"N Formaini","year":"2013","unstructured":"Formaini N, Taylor BC, Backes J, Bramwell TJ (2013) Superior versus anteroinferior plating of clavicle fractures. Orthopedics 36(7):e898\u2013e904","journal-title":"Orthopedics"},{"issue":"2","key":"3294_CR22","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1097\/BOT.0b013e3181dc56b1","volume":"25","author":"J Bellapianta","year":"2011","unstructured":"Bellapianta J, Dow K, Pallotta NA, Hospodar PP, Uhl RL, Ledet EH (2011) Threaded screw head inserts improve locking plate biomechanical properties. J Orthop Trauma 25(2):65\u201371","journal-title":"J Orthop Trauma"},{"key":"3294_CR23","doi-asserted-by":"crossref","unstructured":"Lenza M, Faloppa F (2015) Surgical interventions for treating acute fractures or non\u2010union of the middle third of the clavicle. Cochrane Database of Syst Rev 2015(5):CD007428","DOI":"10.1002\/14651858.CD007428.pub3"},{"issue":"4","key":"3294_CR24","doi-asserted-by":"publisher","first-page":"753","DOI":"10.1016\/j.injury.2018.02.017","volume":"49","author":"MH Hulsmans","year":"2018","unstructured":"Hulsmans MH, Van Heijl M, Houwert RM, Burger BJ, Verleisdonk EJM, Veeger DJ, van der Meijden OA (2018) Surgical fixation of midshaft clavicle fractures: a systematic review of biomechanical studies. Injury 49(4):753\u2013765","journal-title":"Injury"},{"issue":"1","key":"3294_CR25","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.OA.21.00123","volume":"7","author":"J Kitzen","year":"2022","unstructured":"Kitzen J, Paulson K, Korley R, Duffy P, Martin CR, Schneider PS (2022) Biomechanical evaluation of different plate configurations for midshaft clavicle fracture fixation: single plating compared with dual mini-fragment plating. JBJS Open Access 7(1):e21","journal-title":"JBJS Open Access"},{"issue":"6","key":"3294_CR26","doi-asserted-by":"publisher","first-page":"848","DOI":"10.1016\/j.jse.2012.08.022","volume":"22","author":"GR Rieser","year":"2013","unstructured":"Rieser GR, Edwards K, Gould GC, Markert RJ, Goswami T, Rubino LJ (2013) Distal-third clavicle fracture fixation: a biomechanical evaluation of fixation. J Shoulder Elbow Surg 22(6):848\u2013855","journal-title":"J Shoulder Elbow Surg"},{"issue":"7","key":"3294_CR27","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1097\/BOT.0b013e3181c3f6d4","volume":"24","author":"G Partal","year":"2010","unstructured":"Partal G, Meyers KN, Sama N, Pagenkopf E, Lewis PB, Goldman A, Wright TM, Helfet DL (2010) Superior versus anteroinferior plating of the clavicle revisited: a mechanical study. J Orthop Trauma 24(7):420\u2013425","journal-title":"J Orthop Trauma"},{"issue":"12","key":"3294_CR28","doi-asserted-by":"publisher","first-page":"E462","DOI":"10.1097\/BOT.0000000000001318","volume":"32","author":"K Worhacz","year":"2018","unstructured":"Worhacz K, Nayak AN, Boudreaux RL, Pavan B, Wipf F, Jacofsky MC, Araghi A (2018) Biomechanical analysis of superior and anterior precontoured plate fixation techniques for neer type II-A clavicle fractures. J Orthop Trauma 32(12):E462\u2013E468","journal-title":"J Orthop Trauma"},{"key":"3294_CR29","doi-asserted-by":"crossref","unstructured":"Baccouch M (2021) A brief summary of the finite element method for differential equations. In: Baccouch M (ed) Finite element methods and their applications, 1st edn. IntechOpen Limited, London, pp 1\u201342","DOI":"10.5772\/intechopen.95423"},{"key":"3294_CR30","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1007\/978-3-319-74594-7_8","volume-title":"Solid modeling and applications: rapid prototyping, CAD and CAE Theory","author":"D Um","year":"2018","unstructured":"Um D (2018) Finite element modeling and analysis: introduction. In: Um D (ed) Solid modeling and applications: rapid prototyping, CAD and CAE Theory, 2nd edn. Springer, Cham, Switzerland, pp 231\u2013296","edition":"2"},{"issue":"5","key":"3294_CR31","doi-asserted-by":"publisher","first-page":"1375","DOI":"10.1007\/s00466-021-01993-8","volume":"67","author":"E Tamsen","year":"2021","unstructured":"Tamsen E, Balzani D (2021) A general, implicit, finite-strain FE 2 framework for the simulation of dynamic problems on two scales. Comput Mech 67(5):1375\u20131394","journal-title":"Comput Mech"},{"issue":"3","key":"3294_CR32","doi-asserted-by":"publisher","first-page":"43","DOI":"10.3390\/jfb12030043","volume":"12","author":"S Naoum","year":"2021","unstructured":"Naoum S, Vasiliadis AV, Koutserimpas C, Mylonakis N, Kotsapas M, Katakalos K (2021) Finite element method for the evaluation of the human spine: a literature overview. J Funct Biomater 12(3):43","journal-title":"J Funct Biomater"},{"issue":"2","key":"3294_CR33","doi-asserted-by":"publisher","first-page":"958","DOI":"10.3390\/app13020958","volume":"13","author":"V Sciortino","year":"2023","unstructured":"Sciortino V, Pasta S, Ingrassia T, Cerniglia D (2023) On the finite element modeling of the lumbar spine: a schematic review. Appl Sci 13(2):958","journal-title":"Appl Sci"},{"issue":"9","key":"3294_CR34","doi-asserted-by":"publisher","first-page":"963","DOI":"10.1080\/10255842.2011.567983","volume":"15","author":"A Stops","year":"2012","unstructured":"Stops A, Wilcox R, Jin Z (2012) Computational modelling of the natural hip: a review of finite element and multibody simulations. Comput Methods Biomech Biomed Engin 15(9):963\u2013979","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"3294_CR35","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.medengphy.2019.08.002","volume":"74","author":"RJ Cooper","year":"2019","unstructured":"Cooper RJ, Wilcox RK, Jones AC (2019) Finite element models of the tibiofemoral joint: a review of validation approaches and modelling challenges. Med Eng Phys 74:1\u201312","journal-title":"Med Eng Phys"},{"key":"3294_CR36","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1007\/s10439-015-1359-7","volume":"44","author":"Y Wang","year":"2016","unstructured":"Wang Y, Wong DW-C, Zhang M (2016) Computational models of the foot and ankle for pathomechanics and clinical applications: a review. Ann Biomed Eng 44:213\u2013221","journal-title":"Ann Biomed Eng"},{"issue":"9","key":"3294_CR37","doi-asserted-by":"publisher","DOI":"10.1115\/1.4050667","volume":"143","author":"P Phan","year":"2021","unstructured":"Phan P, Vo A, Bakhtiarydavijani A, Burch R, Smith B, Ball JE, Chander H, Knight A, Prabhu R (2021) In silico finite element analysis of the foot ankle complex biomechanics: a literature review. J Biomech Eng 143(9):090802","journal-title":"J Biomech Eng"},{"issue":"4","key":"3294_CR38","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1007\/s11914-021-00690-y","volume":"19","author":"GS Lewis","year":"2021","unstructured":"Lewis GS, Mischler D, Wee H, Reid JS, Varga P (2021) Finite element analysis of fracture fixation. Curr Osteoporos Rep 19(4):403\u2013416","journal-title":"Curr Osteoporos Rep"},{"key":"3294_CR39","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2020.104196","volume":"130","author":"M Feyzi","year":"2021","unstructured":"Feyzi M, Fallahnezhad K, Taylor M, Hashemi R (2021) A review on the finite element simulation of fretting wear and corrosion in the taper junction of hip replacement implants. Comput Biol Med 130:104196","journal-title":"Comput Biol Med"},{"issue":"10","key":"3294_CR40","doi-asserted-by":"publisher","DOI":"10.1016\/j.heliyon.2022.e10940","volume":"8","author":"Y Song","year":"2022","unstructured":"Song Y, Shao E, B\u00edr\u00f3 I, Baker JS, Gu Y (2022) Finite element modelling for footwear design and evaluation: a systematic scoping review. Heliyon 8(10):e10940","journal-title":"Heliyon"},{"issue":"2","key":"3294_CR41","doi-asserted-by":"publisher","first-page":"271","DOI":"10.31616\/asj.2019.0263","volume":"15","author":"S Bidari","year":"2021","unstructured":"Bidari S, Kamyab M, Ghandhari H, Komeili A (2021) Efficacy of computer-aided design and manufacturing versus computer-aided design and finite element modeling technologies in brace management of idiopathic scoliosis: a narrative review. Asian Spine J 15(2):271","journal-title":"Asian Spine J"},{"issue":"2","key":"3294_CR42","doi-asserted-by":"publisher","first-page":"1277","DOI":"10.1007\/s11831-021-09621-7","volume":"29","author":"M Dymek","year":"2022","unstructured":"Dymek M, Ptak M, Fernandes FA (2022) Design and virtual testing of American football helmets\u2013a review. Arch Comput Methods Eng 29(2):1277\u20131289","journal-title":"Arch Comput Methods Eng"},{"key":"3294_CR43","doi-asserted-by":"publisher","DOI":"10.7717\/peerj.6364","volume":"7","author":"DW-C Wong","year":"2019","unstructured":"Wong DW-C, Wang Y, Lin J, Tan Q, Chen TL-W, Zhang M (2019) Sleeping mattress determinants and evaluation: a biomechanical review and critique. PeerJ 7:e6364","journal-title":"PeerJ"},{"key":"3294_CR44","doi-asserted-by":"publisher","DOI":"10.1016\/j.medntd.2021.100067","volume":"11","author":"DW-C Wong","year":"2021","unstructured":"Wong DW-C, Chen TL-W, Peng Y, Lam W-K, Wang Y, Ni M, Niu W, Zhang M (2021) An instrument for methodological quality assessment of single-subject finite element analysis used in computational orthopaedics. Med Novel Technol Dev 11:100067","journal-title":"Med Novel Technol Dev"},{"issue":"10","key":"3294_CR45","doi-asserted-by":"publisher","first-page":"2119","DOI":"10.11124\/JBIES-20-00167","volume":"18","author":"MD Peters","year":"2020","unstructured":"Peters MD, Marnie C, Tricco AC, Pollock D, Munn Z, Alexander L, McInerney P, Godfrey CM, Khalil H (2020) Updated methodological guidance for the conduct of scoping reviews. JBI Evid Synth 18(10):2119\u20132126","journal-title":"JBI Evid Synth"},{"issue":"3","key":"3294_CR46","first-page":"141","volume":"13","author":"MD Peters","year":"2015","unstructured":"Peters MD, Godfrey CM, Khalil H, McInerney P, Parker D, Soares CB (2015) Guidance for conducting systematic scoping reviews. JBI Evid Implement 13(3):141\u2013146","journal-title":"JBI Evid Implement"},{"key":"3294_CR47","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1016\/j.jclinepi.2020.03.016","volume":"123","author":"J McGowan","year":"2020","unstructured":"McGowan J, Straus S, Moher D, Langlois EV, O\u2019Brien KK, Horsley T, Aldcroft A, Zarin W, Garitty CM, Hempel S (2020) Reporting scoping reviews\u2014PRISMA ScR extension. J Clin Epidemiol 123:177\u2013179","journal-title":"J Clin Epidemiol"},{"issue":"8","key":"3294_CR48","doi-asserted-by":"publisher","first-page":"917","DOI":"10.3390\/bioengineering10080917","volume":"10","author":"ES-W Cheng","year":"2023","unstructured":"Cheng ES-W, Lai DK-H, Mao Y-J, Lee TT-Y, Lam W-K, Cheung JC-W, Wong DW-C (2023) Computational biomechanics of sleep: a systematic mapping review. Bioengineering 10(8):917","journal-title":"Bioengineering"},{"key":"3294_CR49","doi-asserted-by":"publisher","unstructured":"Mauri M, Elli T, Caviglia G, Uboldi G, Azzi M (2017) RAWGraphs: a visualisation platform to create open outputs. In: Proceedings of the 12th biannual conference on Italian SIGCHI chapter, Cagliari, pp 1\u20135. https:\/\/doi.org\/10.1145\/3125571.3125585","DOI":"10.1145\/3125571.3125585"},{"issue":"4","key":"3294_CR50","first-page":"41","volume":"20","author":"E Cali\u015fal","year":"2018","unstructured":"Cali\u015fal E, U\u011fur L (2018) Evaluation of the plate location used in clavicle fractures during shoulder abduction and flexion movements: a finite element analysis. Acta Bioeng Biomech 20(4):41\u201346","journal-title":"Acta Bioeng Biomech"},{"issue":"3","key":"3294_CR51","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1007\/s12204-021-2291-7","volume":"26","author":"R Cheng","year":"2021","unstructured":"Cheng R, Jiang Z, Dimitriou D, Gong W, Tsai TY (2021) Biomechanical analysis of personalised 3D-printed clavicle plates of different materials to treat midshaft clavicle fractures. J Shanghai Jiaotong Univ (Science) 26(3):259\u2013266","journal-title":"J Shanghai Jiaotong Univ (Science)"},{"issue":"7","key":"3294_CR52","doi-asserted-by":"publisher","first-page":"740","DOI":"10.1080\/10255842.2013.845175","volume":"18","author":"M Cronsk\u00e4r","year":"2015","unstructured":"Cronsk\u00e4r M, Rasmussen J, Tinnsten M (2015) Combined finite element and multibody musculoskeletal investigation of a fractured clavicle with reconstruction plate. Comput Methods Biomech Biomed Engin 18(7):740\u2013748","journal-title":"Comput Methods Biomech Biomed Engin"},{"issue":"8","key":"3294_CR53","doi-asserted-by":"publisher","first-page":"2152","DOI":"10.1111\/os.13558","volume":"15","author":"ZH Han","year":"2023","unstructured":"Han ZH, Luo Q, Deng GY, Bi C, Yin G, Lin HD, Wu JH, Wu XM (2023) Canceling notch improves the mechanical safety of clavicle locking plate: a 3D finite element study. Orthop Surg 15(8):2152\u20132156","journal-title":"Orthop Surg"},{"issue":"8","key":"3294_CR54","doi-asserted-by":"publisher","first-page":"4805","DOI":"10.1007\/s00402-023-04801-5","volume":"143","author":"DQ Huang","year":"2023","unstructured":"Huang DQ, Hu ZQ, Feng WL, Wang XP (2023) Dual plate has better biomechanical stability than hook plate or superior single plate for the fixation of unstable distal clavicle fractures: a finite element analysis. Arch Orthop Trauma Surg 143(8):4805\u20134812","journal-title":"Arch Orthop Trauma Surg"},{"issue":"10","key":"3294_CR55","doi-asserted-by":"publisher","first-page":"1070","DOI":"10.1016\/j.medengphy.2016.06.021","volume":"38","author":"TL Huang","year":"2016","unstructured":"Huang TL, Chen WC, Lin KJ, Tsai CL, Lin KP, Wei HW (2016) Conceptual finite element study for comparison among superior, anterior, and spiral clavicle plate fixations for midshaft clavicle fracture. Med Eng Phys 38(10):1070\u20131075","journal-title":"Med Eng Phys"},{"issue":"30","key":"3294_CR56","doi-asserted-by":"publisher","first-page":"e29319","DOI":"10.1097\/MD.0000000000029319","volume":"101","author":"D-G Kim","year":"2022","unstructured":"Kim D-G, Min Kim S, Kim Y (2022) Numerical simulation and biomechanical analysis of locking screw caps on clavicle locking plates. Medicine 101(30):e29319\u2013e29319","journal-title":"Medicine"},{"issue":"1","key":"3294_CR57","doi-asserted-by":"publisher","first-page":"6382","DOI":"10.1038\/s41598-024-56588-z","volume":"14","author":"SM Kim","year":"2024","unstructured":"Kim SM, Kim ST, Han DW, Kim DG (2024) Study on the characteristics of increased mechanical stiffness according to changes in LCP shape to reinforce clavicle fractures. Sci Rep 14(1):6382","journal-title":"Sci Rep"},{"issue":"3","key":"3294_CR58","doi-asserted-by":"publisher","first-page":"1465","DOI":"10.1007\/s00590-023-03826-1","volume":"34","author":"A Kritsaneephaiboon","year":"2024","unstructured":"Kritsaneephaiboon A, Jitprapaikulsarn S, Chantarapanich N, Klabklay P, Gromprasit A, Patamamongkonchai C, Dissaneewate P (2024) The application of inverted lateral clavicle locking compression plate for medial clavicle fractures: biomechanical study and clinical implementation. Eur J Orthop Surg Traumatol 34(3):1465\u20131478","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"8","key":"3294_CR59","doi-asserted-by":"publisher","first-page":"759","DOI":"10.1007\/s11517-015-1288-5","volume":"53","author":"C Marie","year":"2015","unstructured":"Marie C (2015) Strength analysis of clavicle fracture fixation devices and fixation techniques using finite element analysis with musculoskeletal force input. Med Biol Eng Compu 53(8):759\u2013769","journal-title":"Med Biol Eng Compu"},{"issue":"2","key":"3294_CR60","first-page":"593","volume":"58","author":"R Marinescu","year":"2017","unstructured":"Marinescu R, Antoniac VI, Stoia DI, L\u0103ptoiu DC (2017) Clavicle anatomical osteosynthesis plate breakage \u2013 failure analysis report based on patient morphological parameters. Rom J Morphol Embryol 58(2):593\u2013598","journal-title":"Rom J Morphol Embryol"},{"issue":"8","key":"3294_CR61","doi-asserted-by":"publisher","first-page":"1618","DOI":"10.1016\/j.injury.2016.06.004","volume":"47","author":"M Ni","year":"2016","unstructured":"Ni M, Niu W, Wong DW-C, Zeng W, Mei J, Zhang M (2016) Finite element analysis of locking plate and two types of intramedullary nails for treating mid-shaft clavicle fractures. Injury 47(8):1618\u20131623","journal-title":"Injury"},{"issue":"3","key":"3294_CR62","first-page":"2106","volume":"20","author":"M Ni","year":"2020","unstructured":"Ni M, Zhang F, Mei J, Lin CYJ, Gruber SMS, Niu W, Wong DWC, Zhang M (2020) Biomechanical analysis of four augmented fixations of plate osteosynthesis for comminuted mid-shaft clavicle fracture: a finite element approach. Exp Ther Med 20(3):2106\u20132112","journal-title":"Exp Ther Med"},{"issue":"4","key":"3294_CR63","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1007\/s40846-021-00635-x","volume":"41","author":"DK Wu","year":"2021","unstructured":"Wu DK, Chen WC, Lin KJ, Tsai CL, Lin KP, Wei HW (2021) Advantage of multi-directional stability of spiral clavicle plate in treatment of middle one-third clavicle fracture: a finite element study. J Med Biol Eng 41(4):405\u2013411","journal-title":"J Med Biol Eng"},{"issue":"5","key":"3294_CR64","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0126131","volume":"10","author":"L Zeng","year":"2015","unstructured":"Zeng L, Wei H, Liu Y, Zhang W, Pan Y, Zhang W, Zhang C, Zeng B, Chen Y (2015) Titanium elastic nail (TEN) versus reconstruction plate repair of midshaft clavicular fractures: a finite element study. PLoS ONE 10(5):e0126131","journal-title":"PLoS ONE"},{"issue":"1","key":"3294_CR65","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1186\/s13018-020-01666-x","volume":"15","author":"F Zhang","year":"2020","unstructured":"Zhang F, Chen F, Qi Y, Qian Z, Ni S, Zhong Z, Zhang X, Li D, Yu B (2020) Finite element analysis of dual small plate fixation and single plate fixation for treatment of midshaft clavicle fractures. J Orthop Surg Res 15(1):148","journal-title":"J Orthop Surg Res"},{"key":"3294_CR66","doi-asserted-by":"crossref","unstructured":"Zhang XJ, Cheng XD, Yin B, Wang JZ, Li S, Liu GB, Hu ZS, Wu WW, Zhang YZ (2019) Finite element analysis of spiral plate and Herbert screw fixation for treatment of midshaft clavicle fractures. Medicine 98(34):e16898","DOI":"10.1097\/MD.0000000000016898"},{"key":"3294_CR67","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1186\/s12891-017-1444-1","volume":"18","author":"C Kihlstr\u00f6m","year":"2017","unstructured":"Kihlstr\u00f6m C, M\u00f6ller M, L\u00f6nn K, Wolf O (2017) Clavicle fractures: epidemiology, classification and treatment of 2 422 fractures in the Swedish Fracture Register; an observational study. BMC Musculoskelet Disord 18:82","journal-title":"BMC Musculoskelet Disord"},{"issue":"1","key":"3294_CR68","doi-asserted-by":"publisher","first-page":"34912","DOI":"10.1038\/srep34912","volume":"6","author":"N Hussain","year":"2016","unstructured":"Hussain N, Sermer C, Prusick PJ, Banfield L, Atrey A, Bhandari M (2016) Intramedullary nailing versus plate fixation for the treatment displaced midshaft clavicular fractures: a systematic review and meta-analysis. Sci Rep 6(1):34912","journal-title":"Sci Rep"},{"key":"3294_CR69","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1186\/s12891-017-1517-1","volume":"18","author":"J Ai","year":"2017","unstructured":"Ai J, Kan S-L, Li H-L, Xu H, Liu Y, Ning G-Z, Feng S-Q (2017) Anterior inferior plating versus superior plating for clavicle fracture: a meta-analysis. BMC Musculoskelet Disord 18:159","journal-title":"BMC Musculoskelet Disord"},{"issue":"2","key":"3294_CR70","doi-asserted-by":"publisher","first-page":"392","DOI":"10.1097\/CORR.0000000000000986","volume":"478","author":"DE Axelrod","year":"2020","unstructured":"Axelrod DE, Ekhtiari S, Bozzo A, Bhandari M, Johal H (2020) What is the best evidence for management of displaced midshaft clavicle fractures? A systematic review and network meta-analysis of 22 randomized controlled trials. Clin Ortho Related Res \u00ae 478(2):392\u2013402","journal-title":"Clin Ortho Related Res \u00ae"},{"key":"3294_CR71","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2020.105199","volume":"80","author":"P Yanev","year":"2020","unstructured":"Yanev P, Zderic I, Pukalski Y, Enchev D, Rashkov M, Varga P, Gehweiler D, Richards G, Gueorguiev B, Baltov A (2020) Two reconstruction plates provide superior stability of displaced midshaft clavicle fractures in comparison to single plating\u2013a biomechanical study. Clin Biomech 80:105199","journal-title":"Clin Biomech"},{"issue":"5","key":"3294_CR72","doi-asserted-by":"publisher","first-page":"500","DOI":"10.1177\/17585732211002495","volume":"14","author":"U Sheth","year":"2022","unstructured":"Sheth U, Fernandez CE, Morgan AM, Henry P, Nam D (2022) Are two plates better than one? A systematic review of dual plating for acute midshaft clavicle fractures. Should Elb 14(5):500\u2013509","journal-title":"Should Elb"},{"issue":"12","key":"3294_CR73","doi-asserted-by":"publisher","first-page":"2337","DOI":"10.1016\/j.jbiomech.2011.05.006","volume":"44","author":"SC Tadepalli","year":"2011","unstructured":"Tadepalli SC, Erdemir A, Cavanagh PR (2011) Comparison of hexahedral and tetrahedral elements in finite element analysis of the foot and footwear. J Biomech 44(12):2337\u20132343","journal-title":"J Biomech"},{"issue":"5","key":"3294_CR74","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1016\/1350-4533(95)97314-F","volume":"17","author":"J-Y Rho","year":"1995","unstructured":"Rho J-Y, Hobatho M, Ashman R (1995) Relations of mechanical properties to density and CT numbers in human bone. Med Eng Phys 17(5):347\u2013355","journal-title":"Med Eng Phys"},{"issue":"11","key":"3294_CR75","doi-asserted-by":"publisher","first-page":"e1450","DOI":"10.3928\/01477447-20131021-31","volume":"36","author":"DJ Wilson","year":"2013","unstructured":"Wilson DJ, Weaver DL, Balog TP, Arrington ED (2013) Early postoperative failure of a new intramedullary fixation device for midshaft clavicle fractures. Orthopedics 36(11):e1450\u2013e1453","journal-title":"Orthopedics"},{"issue":"12","key":"3294_CR76","doi-asserted-by":"publisher","first-page":"3364","DOI":"10.1007\/s11999-011-1867-1","volume":"469","author":"CD Mudd","year":"2011","unstructured":"Mudd CD, Quigley KJ, Gross LB (2011) Excessive complications of open intramedullary nailing of midshaft clavicle fractures with the Rockwood clavicle pin. Clin Ortho Rel Res \u00ae 469(12):3364\u20133370","journal-title":"Clin Ortho Rel Res \u00ae"},{"issue":"9","key":"3294_CR77","doi-asserted-by":"publisher","first-page":"461","DOI":"10.1097\/BOT.0000000000000936","volume":"31","author":"A Nourian","year":"2017","unstructured":"Nourian A, Dhaliwal S, Vangala S, Vezeridis PS (2017) Midshaft fractures of the clavicle: a meta-analysis comparing surgical fixation using anteroinferior plating versus superior plating. J Orthop Trauma 31(9):461\u2013467","journal-title":"J Orthop Trauma"},{"key":"3294_CR78","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1007\/978-3-319-52238-8_2","volume-title":"Clavicle injuries: a case-based guide to diagnosis and treatment","author":"S Guti\u00e9rrez","year":"2018","unstructured":"Guti\u00e9rrez S, Pappou IP, Aira J, Simon P, Frankle MA (2018) Biomechanics of the clavicle. In: Groh GI (ed) Clavicle injuries: a case-based guide to diagnosis and treatment. Springer International Publishing, Cham, pp 19\u201332"},{"issue":"5","key":"3294_CR79","doi-asserted-by":"publisher","first-page":"e814","DOI":"10.3928\/01477447-20160517-06","volume":"39","author":"JM Burnham","year":"2016","unstructured":"Burnham JM, Kim DC, Kamineni S (2016) Midshaft clavicle fractures: a critical review. Orthopedics 39(5):e814\u2013e821","journal-title":"Orthopedics"},{"issue":"1","key":"3294_CR80","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.RVW.22.00171","volume":"11","author":"T Yetter","year":"2023","unstructured":"Yetter T, Harper J, Weatherby PJ, Somerson JS (2023) Complications and outcomes after surgical intervention in clavicular nonunion: a systematic review. JBJS Rev 11(1):e22","journal-title":"JBJS Rev"},{"issue":"2","key":"3294_CR81","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0116907","volume":"10","author":"H Liebl","year":"2015","unstructured":"Liebl H, Garcia EG, Holzner F, Noel PB, Burgkart R, Rummeny EJ, Baum T, Bauer JS (2015) In-vivo assessment of femoral bone strength using Finite Element Analysis (FEA) based on routine MDCT imaging: a preliminary study on patients with vertebral fractures. PLoS ONE 10(2):e0116907","journal-title":"PLoS ONE"},{"issue":"13","key":"3294_CR82","doi-asserted-by":"publisher","first-page":"2982","DOI":"10.1016\/j.jbiomech.2007.02.010","volume":"40","author":"E Schileo","year":"2007","unstructured":"Schileo E, Taddei F, Malandrino A, Cristofolini L, Viceconti M (2007) Subject-specific finite element models can accurately predict strain levels in long bones. J Biomech 40(13):2982\u20132989","journal-title":"J Biomech"},{"key":"3294_CR83","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1007\/s10195-014-0298-7","volume":"15","author":"N Narsaria","year":"2014","unstructured":"Narsaria N, Singh AK, Arun G, Seth R (2014) Surgical fixation of displaced midshaft clavicle fractures: elastic intramedullary nailing versus precontoured plating. J Orthop Traumatol 15:165\u2013171","journal-title":"J Orthop Traumatol"},{"issue":"8","key":"3294_CR84","doi-asserted-by":"publisher","first-page":"1095","DOI":"10.1302\/0301-620X.99B8.BJJ-2016-1318.R1","volume":"99","author":"H Fuglesang","year":"2017","unstructured":"Fuglesang H, Flugsrud G, Randsborg P, Oord P, Benth J, Utv\u00e5g S (2017) Plate fixation versus intramedullary nailing of completely displaced midshaft fractures of the clavicle: a prospective randomised controlled trial. Bone Joint J 99(8):1095\u20131101","journal-title":"Bone Joint J"},{"issue":"7","key":"3294_CR85","doi-asserted-by":"publisher","first-page":"1195","DOI":"10.1016\/j.jse.2016.01.018","volume":"25","author":"RM Houwert","year":"2016","unstructured":"Houwert RM, Smeeing DP, Ali UA, Hietbrink F, Kruyt MC, van der Meijden OA (2016) Plate fixation or intramedullary fixation for midshaft clavicle fractures: a systematic review and meta-analysis of randomized controlled trials and observational studies. J Shoulder Elbow Surg 25(7):1195\u20131203","journal-title":"J Shoulder Elbow Surg"},{"key":"3294_CR86","doi-asserted-by":"publisher","unstructured":"Buenter I, Kremo V, van de Wall B, Link B, Galliker B, Babst R, Beeres F (2022) Superior versus anterior plate fixation for midshaft clavicular fractures\u2013a multicentre analysis. Bri J Surg 109(Supplement_3):znac187\u2013006. https:\/\/doi.org\/10.1093\/bjs\/znac187.006","DOI":"10.1093\/bjs\/znac187.006"},{"issue":"9","key":"3294_CR87","doi-asserted-by":"publisher","first-page":"e263","DOI":"10.1016\/j.jhsa.2016.06.007","volume":"41","author":"A Rongguang","year":"2016","unstructured":"Rongguang A, Zhen J, Jianhua Z, Jifei S, Xinhua J, Baoqing Y (2016) Surgical treatment of displaced midshaft clavicle fractures: precontoured plates versus noncontoured plates. J Hand Surg 41(9):e263\u2013e266","journal-title":"J Hand Surg"},{"key":"3294_CR88","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2024.108036","volume":"245","author":"S Zhan","year":"2024","unstructured":"Zhan S, Jiang D, Hu Q, Wang M, Feng C, Jia W, Hu H, Niu W (2024) Single-plane osteotomy model is inaccurate for evaluating the optimal strategy in treating vertical femoral neck fractures: a finite element analysis. Comput Methods Programs Biomed 245:108036","journal-title":"Comput Methods Programs Biomed"},{"issue":"1","key":"3294_CR89","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1097\/01.prs.0000263537.57701.8b","volume":"120","author":"CML Werner","year":"2007","unstructured":"Werner CML, Favre P, van Lenthe HG, Dumont CE (2007) Pedicled vascularized rib transfer for reconstruction of clavicle nonunions with bony defects: anatomical and biomechanical considerations. Plast Reconstr Surg 120(1):173\u2013180","journal-title":"Plast Reconstr Surg"},{"key":"3294_CR90","doi-asserted-by":"publisher","first-page":"953","DOI":"10.1007\/s11517-013-1099-5","volume":"51","author":"B Bolsterlee","year":"2013","unstructured":"Bolsterlee B, Veeger DH, Chadwick EK (2013) Clinical applications of musculoskeletal modelling for the shoulder and upper limb. Med Biol Eng Compu 51:953\u2013963","journal-title":"Med Biol Eng Compu"},{"key":"3294_CR91","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jsr.2023.08.004","volume":"87","author":"S Wang","year":"2023","unstructured":"Wang S, Feng C, Chen X, Shan M, Niu W (2023) A biomechanical evaluation of firefighters\u2019 musculoskeletal loads when carrying self-contained breathing apparatus in walking and running. J Safety Res 87:1\u201314","journal-title":"J Safety Res"},{"issue":"12","key":"3294_CR92","doi-asserted-by":"publisher","first-page":"3142","DOI":"10.1016\/j.jbiomech.2015.07.013","volume":"48","author":"DW-C Wong","year":"2015","unstructured":"Wong DW-C, Wang Y, Zhang M, Leung AK-L (2015) Functional restoration and risk of non-union of the first metatarsocuneiform arthrodesis for hallux valgus: a finite element approach. J Biomech 48(12):3142\u20133148","journal-title":"J Biomech"},{"issue":"2","key":"3294_CR93","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1007\/s10409-014-0027-8","volume":"30","author":"J Yao","year":"2014","unstructured":"Yao J, Kuang G-M, Wong DW-C, Niu W-X, Zhang M, Fan Y-B (2014) Influence of screw length and diameter on tibial strain energy density distribution after anterior cruciate ligament reconstruction. Acta Mech Sin 30(2):241\u2013249","journal-title":"Acta Mech Sin"},{"issue":"4","key":"3294_CR94","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0154435","volume":"11","author":"DW-C Wong","year":"2016","unstructured":"Wong DW-C, Niu W, Wang Y, Zhang M (2016) Finite element analysis of foot and ankle impact injury: risk evaluation of calcaneus and talus fracture. PLoS ONE 11(4):e0154435","journal-title":"PLoS ONE"},{"key":"3294_CR95","doi-asserted-by":"publisher","DOI":"10.1002\/cnm.2710","volume":"31","author":"M Pendergast","year":"2015","unstructured":"Pendergast M, Rusovici R (2015) A finite element parametric study of clavicle fixation plates. InteJ Numeric Methods Biomed Eng 31:e02710","journal-title":"InteJ Numeric Methods Biomed Eng"},{"issue":"1","key":"3294_CR96","doi-asserted-by":"publisher","first-page":"369","DOI":"10.1186\/s12967-020-02540-4","volume":"18","author":"A Erdemir","year":"2020","unstructured":"Erdemir A, Mulugeta L, Ku JP, Drach A, Horner M, Morrison TM, Peng GC, Vadigepalli R, Lytton WW, Myers JG Jr (2020) Credible practice of modeling and simulation in healthcare: ten rules from a multidisciplinary perspective. J Transl Med 18(1):369","journal-title":"J Transl Med"},{"key":"3294_CR97","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1016\/j.bone.2013.12.006","volume":"60","author":"N Sarkalkan","year":"2014","unstructured":"Sarkalkan N, Weinans H, Zadpoor AA (2014) Statistical shape and appearance models of bones. Bone 60:129\u2013140","journal-title":"Bone"},{"key":"3294_CR98","doi-asserted-by":"publisher","first-page":"2945","DOI":"10.1007\/s11831-024-10063-0","volume":"31","author":"D Nath","year":"2024","unstructured":"Nath D, Ankit NDR, Gautam SS (2024) Application of machine learning and deep learning in finite element analysis: a comprehensive review. Arch Comput Methods Eng 31:2945\u20132984","journal-title":"Arch Comput Methods Eng"},{"key":"3294_CR99","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2022.102562","volume":"82","author":"W Dai","year":"2022","unstructured":"Dai W, Woo B, Liu S, Marques M, Engstrom C, Greer PB, Crozier S, Dowling JA, Chandra SS (2022) CAN3D: Fast 3D medical image segmentation via compact context aggregation. Med Image Anal 82:102562","journal-title":"Med Image Anal"},{"key":"3294_CR100","doi-asserted-by":"publisher","DOI":"10.1016\/j.cma.2020.113401","volume":"372","author":"J Jung","year":"2020","unstructured":"Jung J, Yoon K, Lee P-S (2020) Deep learned finite elements. Comput Methods Appl Mech Eng 372:113401","journal-title":"Comput Methods Appl Mech Eng"},{"issue":"138","key":"3294_CR101","doi-asserted-by":"publisher","first-page":"20170844","DOI":"10.1098\/rsif.2017.0844","volume":"15","author":"L Liang","year":"2018","unstructured":"Liang L, Liu M, Martin C, Sun W (2018) A deep learning approach to estimate stress distribution: a fast and accurate surrogate of finite-element analysis. J R Soc Interface 15(138):20170844","journal-title":"J R Soc Interface"},{"issue":"4","key":"3294_CR102","doi-asserted-by":"publisher","first-page":"333","DOI":"10.21037\/atm-20-7824","volume":"9","author":"M Ni","year":"2021","unstructured":"Ni M, Lv ML, Sun W, Zhang Y, Mei J, Wong DW-C, Zhang H, Jia Y, Zhang M (2021) Fracture mapping of complex intra-articular calcaneal fractures. Ann Transl Med 9(4):333","journal-title":"Ann Transl Med"},{"key":"3294_CR103","doi-asserted-by":"publisher","DOI":"10.1016\/j.medntd.2022.100190","volume":"16","author":"Y-Q Wang","year":"2022","unstructured":"Wang Y-Q, Li P-F, Xu Z-H, Zhang Y-Q, Lee Q-N, Cheung JC-W, Ni M, Wong DW-C (2022) Augmented reality (AR) and fracture mapping model on middle-aged femoral neck fracture: a proof-of-concept towards interactive visualization. Med Novel Technol Dev 16:100190","journal-title":"Med Novel Technol Dev"},{"issue":"5","key":"3294_CR104","doi-asserted-by":"publisher","first-page":"1280","DOI":"10.1007\/s10439-024-03452-w","volume":"52","author":"G Maquer","year":"2024","unstructured":"Maquer G, Mueri C, Henderson A, Bischoff J, Favre P (2024) Developing and validating a model of humeral stem primary stability, intended for in silico clinical trials. Ann Biomed Eng 52(5):1280\u20131296","journal-title":"Ann Biomed Eng"},{"issue":"4","key":"3294_CR105","doi-asserted-by":"publisher","first-page":"930","DOI":"10.1111\/os.14021","volume":"16","author":"Cd Liu","year":"2024","unstructured":"Liu Cd, Sj Hu, Chang SM, Sc Du, Wf X, Yq C (2024) Importance of the posterior plate in three-column tibial plateau fractures: a finite element analysis and clinical validation. Orthop Surg 16(4):930\u2013942","journal-title":"Orthop Surg"},{"key":"3294_CR106","doi-asserted-by":"publisher","first-page":"465","DOI":"10.1186\/s12891-019-2847-y","volume":"20","author":"N Pengrung","year":"2019","unstructured":"Pengrung N, Lakdee N, Puncreobutr C, Lohwongwatana B, Sa-ngasoongsong P (2019) Finite element analysis comparison between superior clavicle locking plate with and without screw holes above fracture zone in midshaft clavicular fracture. BMC Musculoskelet Disord 20:465","journal-title":"BMC Musculoskelet Disord"},{"issue":"16","key":"3294_CR107","doi-asserted-by":"publisher","first-page":"5651","DOI":"10.3390\/app10165651","volume":"10","author":"KS Shih","year":"2020","unstructured":"Shih KS, Hsu CC, Shih BY (2020) A biomechanical study of various fixation strategies for the treatment of clavicle fractures using three-dimensional upper-body musculoskeletal finite element models. Appl Sci 10(16):5651","journal-title":"Appl Sci"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-025-03294-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11517-025-03294-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-025-03294-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,26]],"date-time":"2025-05-26T07:03:30Z","timestamp":1748243010000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11517-025-03294-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,28]]},"references-count":107,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025,6]]}},"alternative-id":["3294"],"URL":"https:\/\/doi.org\/10.1007\/s11517-025-03294-1","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,28]]},"assertion":[{"value":"14 May 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 January 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 January 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}