{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,28]],"date-time":"2026-02-28T07:09:55Z","timestamp":1772262595227,"version":"3.50.1"},"reference-count":45,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2025,11,29]],"date-time":"2025-11-29T00:00:00Z","timestamp":1764374400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,11,29]],"date-time":"2025-11-29T00:00:00Z","timestamp":1764374400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["52035012"],"award-info":[{"award-number":["52035012"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2026,2]]},"DOI":"10.1007\/s11517-025-03483-y","type":"journal-article","created":{"date-parts":[[2025,11,29]],"date-time":"2025-11-29T05:58:21Z","timestamp":1764395901000},"page":"739-753","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["An algorithm for personalized optimal acetabular cup implant positioning based on bony coverage rate and impingement-free range of motion"],"prefix":"10.1007","volume":"64","author":[{"given":"Tao","family":"Feng","sequence":"first","affiliation":[]},{"given":"Yunxin","family":"Tian","sequence":"additional","affiliation":[]},{"given":"Cheng","family":"Liang","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4608-5401","authenticated-orcid":false,"given":"Xiaogang","family":"Zhang","sequence":"additional","affiliation":[]},{"given":"Jianjun","family":"Zou","sequence":"additional","affiliation":[]},{"given":"Yali","family":"Zhang","sequence":"additional","affiliation":[]},{"given":"Zhongmin","family":"Jin","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2025,11,29]]},"reference":[{"issue":"4","key":"3483_CR1","doi-asserted-by":"publisher","first-page":"1101","DOI":"10.1016\/j.arth.2017.11.010","volume":"33","author":"BPDS Murphy","year":"2018","unstructured":"Murphy BPDS, Dowsey MM, Spelman T, Choong PFM (2018) What is the impact of advancing age on the outcomes of total hip arthroplasty? J Arthroplasty 33(4):1101","journal-title":"J Arthroplasty"},{"issue":"11","key":"3483_CR2","doi-asserted-by":"publisher","first-page":"3484","DOI":"10.1016\/j.arth.2018.07.005","volume":"33","author":"D Dimitriou","year":"2018","unstructured":"Dimitriou D, Antoniadis A, Flury A, Liebhauser M, Helmy N (2018) Total hip arthroplasty improves the quality-adjusted life years in patients who exceeded the estimated life expectancy. J Arthroplasty 33(11):3484","journal-title":"J Arthroplasty"},{"issue":"2","key":"3483_CR3","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1503\/cjs.007214","volume":"58","author":"S Petis","year":"2015","unstructured":"Petis S, Howard JL, Lanting BL, Vasarhelyi EM (2015) Surgical approach in primary total hip arthroplasty: anatomy, technique and clinical outcomes. Can J Surg 58(2):128","journal-title":"Can J Surg"},{"issue":"4","key":"3483_CR4","doi-asserted-by":"publisher","first-page":"553","DOI":"10.1016\/S0030-5898(05)70226-1","volume":"32","author":"CF Scifert","year":"2001","unstructured":"Scifert CF, Noble PC, Brown TD, Bartz RL, Kadakia N, Sugano N, Johnston RC, Pedersen DR, Callaghan JJ (2001) Experimental and computational simulation of total hip arthroplasty dislocation. Orthop Clin North Am 32(4):553","journal-title":"Orthop Clin North Am"},{"issue":"1","key":"3483_CR5","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1080\/17453674.2016.1251255","volume":"88","author":"KG Seagrave","year":"2017","unstructured":"Seagrave KG, Troelsen A, Malchau H, Husted H, Gromov K (2017) Acetabular cup position and risk of dislocation in primary total hip arthroplasty. Acta Orthop 88(1):10","journal-title":"Acta Orthop"},{"issue":"11","key":"3483_CR6","doi-asserted-by":"publisher","first-page":"1050","DOI":"10.1111\/j.1525-1594.2004.00017.x","volume":"28","author":"H Oki","year":"2004","unstructured":"Oki H, Ando M, Omori H, Okumura Y, Negoro K, Uchida K, Baba H (2004) Relation between vertical orientation and stability of acetabular component in the dysplastic hip simulated by nonlinear three-dimensional finite element method. Artif Organs 28(11):1050","journal-title":"Artif Organs"},{"issue":"7","key":"3483_CR7","doi-asserted-by":"publisher","DOI":"10.1308\/rcsann.2018.0112","volume":"100","author":"XD Wu","year":"2018","unstructured":"Wu XD, Xu W, Tian M, Cheng Q, Huang W (2018) Cup-on-cup technique to manage severe protrusio acetabular defects. Ann R Coll Surg Engl 100(7):e181","journal-title":"Ann R Coll Surg Engl"},{"issue":"1","key":"3483_CR8","doi-asserted-by":"publisher","first-page":"15","DOI":"10.2106\/00004623-197961010-00004","volume":"61","author":"JF Crowe","year":"1979","unstructured":"Crowe JF, Mani VJ, Ranawat CS (1979) Total hip replacement in congenital dislocation and dysplasia of the hip. J Bone Joint Surg Am 61(1):15","journal-title":"J Bone Joint Surg Am"},{"issue":"6","key":"3483_CR9","doi-asserted-by":"publisher","first-page":"1720","DOI":"10.1016\/j.arth.2020.01.019","volume":"35","author":"C Schulze","year":"2020","unstructured":"Schulze C, Morgenroth R, Bader R, Kluess D, Haas H (2020) Fixation stability of uncemented acetabular cups with respect to different bone defect sizes. J Arthroplasty 35(6):1720","journal-title":"J Arthroplasty"},{"issue":"1","key":"3483_CR10","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-022-05168-1","volume":"23","author":"Y Wang","year":"2022","unstructured":"Wang Y, Wang M, Li C, Nakamura Y, Deng L, Yamako G, Chosa E, Pan C (2022) Biomechanical effect of metal augment and bone graft on cup stability for acetabular reconstruction of total hip arthroplasty in hip dysplasia: a finite element analysis. BMC Musculoskelet Disord 23(1):277","journal-title":"BMC Musculoskelet Disord"},{"key":"3483_CR11","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200403000-00014","volume":"420","author":"KJ Bozic","year":"2004","unstructured":"Bozic KJ, Freiberg AA, Harris WH (2004) The high hip center. Clin Orthop Relat Res 420:101","journal-title":"Clin Orthop Relat Res"},{"issue":"1","key":"3483_CR12","doi-asserted-by":"publisher","first-page":"55","DOI":"10.5301\/hipint.5000419","volume":"27","author":"D Lakstein","year":"2017","unstructured":"Lakstein D, Tan Z, Oren N, M\u00e4kinen TJ, Gross AE, Safir O (2017) Preoperative planning of total hip arthroplasty on dysplastic acetabuli. Hip Int 27(1):55","journal-title":"Hip Int"},{"issue":"3","key":"3483_CR13","doi-asserted-by":"publisher","DOI":"10.3390\/jcm12030751","volume":"12","author":"C Faldini","year":"2023","unstructured":"Faldini C, Brunello M, Pilla F, Geraci G, Stefanini N, Tassinari L, Di Martino A (2023) Femoral head autograft to manage acetabular bone loss defects in THA for Crowe III hips by DAA: retrospective study and surgical technique. J Clin Med 12(3):751","journal-title":"J Clin Med"},{"issue":"3","key":"3483_CR14","doi-asserted-by":"publisher","first-page":"518","DOI":"10.1177\/11207000211059442","volume":"33","author":"A Kannan","year":"2023","unstructured":"Kannan A, Madurawe C, Pierrepont J, McMahon S (2023) Does total hip arthroplasty with high hip centre in dysplasia compromise acetabular bone stock? Hip Int 33(3):518","journal-title":"Hip Int"},{"key":"3483_CR15","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-018-2097-4","volume":"19","author":"R Debi","year":"2018","unstructured":"Debi R, Slamowicz E, Cohen O, Elbaz A, Lubovsky O, Lakstein D, Tan Z, Atoun E (2018) Acetabular cup orientation and postoperative leg length discrepancy in patients undergoing elective total hip arthroplasty via a direct anterior and anterolateral approaches. BMC Musculoskelet Disord 19:188","journal-title":"BMC Musculoskelet Disord"},{"issue":"1","key":"3483_CR16","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-023-03735-3","volume":"18","author":"R Tian","year":"2023","unstructured":"Tian R, Duan XD, Kong N, Wang KZ, Yang P (2023) Precise acetabular positioning, discrepancy in leg length, and hip offset using a new seven-axis robot-assisted total hip arthroplasty system requires no learning curve: a retrospective study. J Orthop Surg Res 18(1):236","journal-title":"J Orthop Surg Res"},{"key":"3483_CR17","doi-asserted-by":"crossref","unstructured":"Hidayat T, Ammarullah MI, Saputra E, Lamura MDP, Chethan KN, Ismail R, Bayuseno AP, Jamari J (2024) A method for estimating the contact area of a dual-mobility total hip prosthesis. Aip Adv 14(1)","DOI":"10.1063\/5.0188638"},{"key":"3483_CR18","doi-asserted-by":"crossref","unstructured":"G\u00f6kta\u015f H, Suba\u015fi E, Uzkut M, Kara M, Bi\u00e7ici H, Shirazi H, Chethan KN, Mih\u00e7in \u015e (2021) Optimization of hip implant designs based on its mechanical behaviour. In: The International Conference of the Polish Society of Biomechanics. Springer. p:37-43.","DOI":"10.1007\/978-3-030-86297-8_4"},{"issue":"6","key":"3483_CR19","doi-asserted-by":"publisher","DOI":"10.1088\/2057-1976\/acfe14","volume":"9","author":"JV Corda","year":"2023","unstructured":"Corda JV, Chethan KN, Bhat NS, Shetty S, Shenoy BS, Zuber M (2023) Finite element analysis of elliptical shaped stem profile of hip prosthesis using dynamic loading conditions. Biomed Phys Eng Expr 9(6):065028","journal-title":"Biomed Phys Eng Expr"},{"issue":"4","key":"3483_CR20","doi-asserted-by":"publisher","first-page":"321","DOI":"10.5312\/wjo.v15.i4.321","volume":"15","author":"T Hidayat","year":"2024","unstructured":"Hidayat T, Ammarullah MI, Ismail R, Saputra E, Lamura MDP, Chethan KN, Bayuseno AP, Jamari J (2024) Investigation of contact behavior on a model of the dual-mobility artificial hip joint for Asians in different inner liner thicknesses. World J Orthop 15(4):321","journal-title":"World J Orthop"},{"issue":"1","key":"3483_CR21","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20171114-01","volume":"41","author":"Y Nie","year":"2018","unstructured":"Nie Y, Wang HY, Huang ZY, Shen B, Kraus VB, Zhou ZK (2018) Radiographic underestimation of in vivo cup coverage provided by total hip arthroplasty for dysplasia. Orthopedics 41(1):E46","journal-title":"Orthopedics"},{"issue":"10","key":"3483_CR22","doi-asserted-by":"publisher","first-page":"1746","DOI":"10.1016\/j.jbiomech.2013.03.025","volume":"46","author":"L Wang","year":"2013","unstructured":"Wang L, Thoreson AR, Trousdale RT, Morrey BF, Dai KR, An KN (2013) Two-dimensional and three-dimensional cup coverage in total hip arthroplasty with developmental dysplasia of the hip. J Biomech 46(10):1746","journal-title":"J Biomech"},{"issue":"1","key":"3483_CR23","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1016\/j.arth.2018.09.082","volume":"34","author":"T Ueno","year":"2019","unstructured":"Ueno T, Kabata T, Kajino Y, Ohmori T, Yoshitani J, Tsuchiya H (2019) Three-dimensional host bone coverage required in total hip arthroplasty for developmental dysplasia of the hip and its relationship with 2-dimensional coverage. J Arthroplasty 34(1):93\u2013101","journal-title":"J Arthroplasty"},{"issue":"19","key":"3483_CR24","doi-asserted-by":"publisher","DOI":"10.3390\/jcm12196227","volume":"12","author":"CJ Yon","year":"2023","unstructured":"Yon CJ, Lee KJ, Choi BC, Suh HS, Min BW (2023) The validation of two-dimensional and three-dimensional radiographic measurements of host bone coverage in total hip arthroplasty for hip dysplasia: a comparison with intra-operative measurements. J Clin Med 12(19):6227","journal-title":"J Clin Med"},{"issue":"7","key":"3483_CR25","doi-asserted-by":"publisher","DOI":"10.1016\/S0021-9290(02)00040-4","volume":"35","author":"F Yoshimine","year":"2002","unstructured":"Yoshimine F, Ginbayashi K (2002) A mathematical formula to calculate the theoretical range of motion for total hip replacement. J Biomech 35(7):989","journal-title":"J Biomech"},{"issue":"5","key":"3483_CR26","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2010.01.012","volume":"25","author":"WT Ji","year":"2010","unstructured":"Ji WT, Tao K, Wang CT (2010) A three-dimensional parameterized and visually kinematic simulation module for the theoretical range of motion of total hip arthroplasty. Clin Biomech (Bristol, Avon) 25(5):427","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"10","key":"3483_CR27","doi-asserted-by":"publisher","DOI":"10.1177\/0954411912455009","volume":"226","author":"P Ellison","year":"2012","unstructured":"Ellison P (2012) Mathematical formulae to calculate the theoretical range of motion of prosthetic hip implants with non-circular neck geometry. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 226(10):804","journal-title":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine"},{"issue":"11","key":"3483_CR28","doi-asserted-by":"publisher","DOI":"10.1002\/jor.25585","volume":"41","author":"T Feng","year":"2023","unstructured":"Feng T, Tang H, Zhang X, Zhang Y, Zhou Y, Jin Z (2023) A novel algorithm to efficiently calculate the impingement-free range of motion of irregularly-shaped total hip arthroplasty components. J Orthop Res 41(11):2516","journal-title":"J Orthop Res"},{"issue":"3","key":"3483_CR29","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1177\/09544119251319960","volume":"239","author":"T Feng","year":"2025","unstructured":"Feng T, Tang H, Zhang X, Zhang Y, Zhou Y, Jin Z (2025) A novel preoperative prosthetic position planning algorithm for total hip arthroplasty based on the no-impingement principle: a case study. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 239(3):321","journal-title":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine"},{"issue":"2","key":"3483_CR30","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1016\/j.jos.2018.08.019","volume":"24","author":"Y Sakemi","year":"2019","unstructured":"Sakemi Y, Komiyama K, Yoshimoto K, Shiomoto K, Iwamoto M, Nakashima Y (2019) How does anteroposterior cup placement affect bone coverage and range of motion in primary total hip arthroplasty for hip dysplasia? J Orthop Sci 24(2):269","journal-title":"J Orthop Sci"},{"issue":"3","key":"3483_CR31","doi-asserted-by":"publisher","first-page":"465","DOI":"10.1007\/s00590-019-02589-y","volume":"30","author":"Y Masumoto","year":"2020","unstructured":"Masumoto Y, Fukunishi S, Fukui T, Yoshiya S, Nishio S, Fujihara Y, Okahisa S, Okada T, Kanto M, Goshi A, Morio F, Takeda Y (2020) New combined anteversion technique in hybrid THA: cup-first procedure with CT-based navigation. Eur J Orthop Surg Traumatol 30(3):465","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"4","key":"3483_CR32","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1016\/S0021-9290(01)00222-6","volume":"35","author":"G Wu","year":"2002","unstructured":"Wu G, Siegler S, Allard P, Kirtley C, Leardini A, Rosenbaum D, Whittle M, D\u2019Lima DD, Cristofolini L, Witte H, Schmid O, Stokes H (2002) ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion - part 1: ankle, hip, and spine. J Biomech 35(4):543","journal-title":"J Biomech"},{"key":"3483_CR33","doi-asserted-by":"crossref","unstructured":"M\u00f6ller T, Trumbore B (2005) Fast, minimum storage ray\/triangle intersection. In: ACM SIGGRAPH 2005 Courses. Los Angeles, California: Association for Computing Machinery. p:7-es.","DOI":"10.1145\/1198555.1198746"},{"key":"3483_CR34","unstructured":"Seers T (2024) Fast mesh-mesh intersection using ray-tri intersection with octree spatial partitioning. In: MATLAB central file exchange. Available via https:\/\/ww2.mathworks.cn\/matlabcentral\/fileexchange\/49160-fast-mesh-mesh-intersection-using-ray-tri-intersection-with-octree-spatial-partitioning?s_tid=srchtitle"},{"key":"3483_CR35","unstructured":"Tuszynski J (2024) in_polyhedron. In: MATLAB central file exchange. Available via https:\/\/ww2.mathworks.cn\/matlabcentral\/fileexchange\/48041-in_polyhedron?s_tid=srchtitle"},{"issue":"1","key":"3483_CR36","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1097\/CORR.0000000000001923","volume":"480","author":"H Tang","year":"2022","unstructured":"Tang H, Li Y, Zhou Y, Wang S, Zhao Y, Ma Z (2022) A modeling study of a patient-specific safe zone for THA: calculation, validation, and key factors based on standing and sitting sagittal pelvic tilt. Clin Orthop Relat Res 480(1):191","journal-title":"Clin Orthop Relat Res"},{"key":"3483_CR37","doi-asserted-by":"publisher","DOI":"10.1007\/s11517-024-03257-y","author":"HX Shi","year":"2024","unstructured":"Shi HX, Zhang XG, Chen ZX, Zhang YL, Jin ZM (2024) The influence of PEEK acetabular shell on the mechanical stability of total hip replacements under gait loading and motion. Med Biol Eng Comput. https:\/\/doi.org\/10.1007\/s11517-024-03257-y","journal-title":"Med Biol Eng Comput"},{"issue":"11","key":"3483_CR38","doi-asserted-by":"publisher","first-page":"1471","DOI":"10.1016\/S0021-9290(00)00096-8","volume":"33","author":"IR Spears","year":"2000","unstructured":"Spears IR, Pfleiderer M, Schneider E, Hille E, Bergmann G, Morlock MM (2000) Interfacial conditions between a press-fit acetabular cup and bone during daily activities: implications for achieving bone in-growth. J Biomech 33(11):1471","journal-title":"J Biomech"},{"key":"3483_CR39","doi-asserted-by":"publisher","DOI":"10.1016\/j.ics.2004.03.016","volume":"1268","author":"M Takao","year":"2004","unstructured":"Takao M, Sugano N, Nishii T, Miki H, Koyama T, Yoshikawa H (2004) Host bone coverage requirements for press-fit acetabular cup fixation. 3D-CT analysis. Int Congr Ser 1268:1299","journal-title":"Int Congr Ser"},{"key":"3483_CR40","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-021-02745-3","author":"JW Zhang","year":"2021","unstructured":"Zhang JW, Kong KY, Chi YJ, Liu XL, Zeng YM, Li HW (2021) Evaluation of the feasibility of acetabular cup pre-determination in revision total hip arthroplasty via X-ray of the bone stock of the anterosuperior acetabulum. J Orthop Surg Res. https:\/\/doi.org\/10.1186\/s13018-021-02745-3","journal-title":"J Orthop Surg Res"},{"issue":"5","key":"3483_CR41","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1007\/s00132-020-03895-8","volume":"49","author":"M Ghanem","year":"2020","unstructured":"Ghanem M, Zajonz D, Heyde CE, Roth A (2020) Acetabular defect classification and management revision arthroplasty of the acetabular cup based on 3-point fixation. Orthopade 49(5):432","journal-title":"Orthopade"},{"issue":"4","key":"3483_CR42","doi-asserted-by":"publisher","first-page":"1284","DOI":"10.1007\/s11999-014-4072-1","volume":"473","author":"B Larkin","year":"2015","unstructured":"Larkin B, van Holsbeeck M, Koueiter D, Zaltz I (2015) What is the impingement-free range of motion of the asymptomatic hip in young adult males? Clin Orthop Relat Res 473(4):1284","journal-title":"Clin Orthop Relat Res"},{"issue":"2","key":"3483_CR43","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1007\/s00264-016-3216-1","volume":"41","author":"M Woerner","year":"2017","unstructured":"Woerner M, Weber M, Sendtner E, Springorum R, Worlicek M, Craiovan B, Grifka J, Renkawitz T (2017) Soft tissue restricts impingement-free mobility in total hip arthroplasty. Int Orthop 41(2):277","journal-title":"Int Orthop"},{"issue":"4","key":"3483_CR44","doi-asserted-by":"publisher","first-page":"484","DOI":"10.1302\/0301-620X.97B4.34638","volume":"97b","author":"RJ van Arkel","year":"2015","unstructured":"van Arkel RJ, Amis AA, Cobb JP, Jeffers JRT (2015) The capsular ligaments provide more hip rotational restraint than the acetabular labrum and the ligamentum teres. Bone Joint J 97b(4):484","journal-title":"Bone Joint J"},{"issue":"14","key":"3483_CR45","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2015.09.002","volume":"48","author":"RJ van Arkel","year":"2015","unstructured":"van Arkel RJ, Amis AA, Jeffers JRT (2015) The envelope of passive motion allowed by the capsular ligaments of the hip. J Biomech 48(14):3803","journal-title":"J Biomech"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-025-03483-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11517-025-03483-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-025-03483-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,28]],"date-time":"2026-02-28T04:26:02Z","timestamp":1772252762000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11517-025-03483-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,29]]},"references-count":45,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,2]]}},"alternative-id":["3483"],"URL":"https:\/\/doi.org\/10.1007\/s11517-025-03483-y","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,29]]},"assertion":[{"value":"18 May 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 October 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 November 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This work was approved by the Ethics Committee of Affiliated Hospital of Southwest Medical University, with approval No. KY2021135. All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics statement"}},{"value":"The authors declare no conflicts of interest.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interest"}}]}}