{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T03:42:27Z","timestamp":1777866147061,"version":"3.51.4"},"reference-count":49,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2026,3,30]],"date-time":"2026-03-30T00:00:00Z","timestamp":1774828800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,3,30]],"date-time":"2026-03-30T00:00:00Z","timestamp":1774828800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2026,5]]},"DOI":"10.1007\/s11517-026-03564-6","type":"journal-article","created":{"date-parts":[[2026,3,30]],"date-time":"2026-03-30T10:13:05Z","timestamp":1774865585000},"page":"1955-1969","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Does FNS outperform CCS in Pauwel\u2019s type III fracture fixation: a combined experimental and numerical study"],"prefix":"10.1007","volume":"64","author":[{"given":"Laureb","family":"Rao","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Samarth","family":"Mittal","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Apoorva","family":"Kabra","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vivek","family":"Trikha","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anoop","family":"Chawla","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8290-2803","authenticated-orcid":false,"given":"Kaushik","family":"Mukherjee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,3,30]]},"reference":[{"key":"3564_CR1","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-019-2990-5","volume":"20","author":"JL Xu","year":"2019","unstructured":"Xu JL, Liang ZR, Xiong BL et al (2019) Risk factors associated with osteonecrosis of femoral head after internal fixation of femoral neck fracture: a systematic review and meta-analysis. BMC Musculoskelet Disord 20:632","journal-title":"BMC Musculoskelet Disord"},{"key":"3564_CR2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2014.12.031","author":"M Panteli","year":"2015","unstructured":"Panteli M, Rodham P, Giannoudis PV (2015) Biomechanical rationale for implant choices in femoral neck fracture fixation in the non-elderly. Injury. https:\/\/doi.org\/10.1016\/j.injury.2014.12.031","journal-title":"Injury"},{"key":"3564_CR3","doi-asserted-by":"publisher","first-page":"358","DOI":"10.1097\/00005131-200106000-00009","volume":"15","author":"J Barton\u00ed\u010dek","year":"2001","unstructured":"Barton\u00ed\u010dek J (2001) Pauwels\u2019 classification of femoral neck fractures: correct interpretation of the original. J Orthop Trauma 15:358\u2013360. https:\/\/doi.org\/10.1097\/00005131-200106000-00009","journal-title":"J Orthop Trauma"},{"key":"3564_CR4","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1177\/2151458512463392","volume":"3","author":"IB Menzies","year":"2012","unstructured":"Menzies IB, Mendelson DA, Kates SL, Friedman SM (2012) The impact of comorbidity on perioperative outcomes of hip fractures in a geriatric fracture model. Geriatr Orthop Surg Rehabil 3:129\u2013134. https:\/\/doi.org\/10.1177\/2151458512463392","journal-title":"Geriatr Orthop Surg Rehabil"},{"key":"3564_CR5","doi-asserted-by":"publisher","DOI":"10.3390\/jcm13051418","author":"HH Lee","year":"2024","unstructured":"Lee HH, Kang KY, Sung SY et al (2024) Femoral neck fractures treated by closed reduction and internal fixation with the double fluoroscope technique: a preliminary study. J Clin Med. https:\/\/doi.org\/10.3390\/jcm13051418","journal-title":"J Clin Med"},{"key":"3564_CR6","doi-asserted-by":"publisher","first-page":"S27","DOI":"10.1097\/BOT.0000000000001365","volume":"33","author":"P Augat","year":"2019","unstructured":"Augat P, Bliven E, Hackl S (2019) Biomechanics of femoral neck fractures and implications for fixation. J Orthop Trauma 33:S27\u2013S32. https:\/\/doi.org\/10.1097\/BOT.0000000000001365","journal-title":"J Orthop Trauma"},{"key":"3564_CR7","doi-asserted-by":"publisher","first-page":"995","DOI":"10.1016\/j.injury.2020.02.075","volume":"51","author":"J Li","year":"2020","unstructured":"Li J, Wang M, Zhou J et al (2020) Finite element analysis of different screw constructs in the treatment of unstable femoral neck fractures. Injury 51:995\u20131003. https:\/\/doi.org\/10.1016\/j.injury.2020.02.075","journal-title":"Injury"},{"key":"3564_CR8","doi-asserted-by":"publisher","first-page":"683","DOI":"10.1007\/s00264-006-0248-y","volume":"31","author":"YS Lee","year":"2007","unstructured":"Lee YS, Huang HL, Lo TY, Huang CR (2007) Dynamic hip screw in the treatment of intertrochanteric fractures: a comparison of two fixation methods. Int Orthop 31:683\u2013688. https:\/\/doi.org\/10.1007\/s00264-006-0248-y","journal-title":"Int Orthop"},{"key":"3564_CR9","doi-asserted-by":"publisher","first-page":"3207","DOI":"10.1007\/s00590-024-04051-0","volume":"34","author":"A Caldaria","year":"2024","unstructured":"Caldaria A, Gambuti E, Biagi N et al (2024) Comparison of femoral neck system versus cannulated cancellous screws for the fixation of femoral neck fracture: a single-center retrospective cohort study. Eur J Orthop Surg Traumatol 34:3207\u20133213. https:\/\/doi.org\/10.1007\/s00590-024-04051-0","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"3564_CR10","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-022-11914-1","volume":"12","author":"JK Moon","year":"2022","unstructured":"Moon JK, Lee JI, Hwang KT et al (2022) Biomechanical comparison of the femoral neck system and the dynamic hip screw in basicervical femoral neck fractures. Sci Rep 12:7915. https:\/\/doi.org\/10.1038\/s41598-022-11914-1","journal-title":"Sci Rep"},{"key":"3564_CR11","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2024.111717","volume":"55","author":"B Mahapatra","year":"2024","unstructured":"Mahapatra B, Pal B (2024) Biomechanical analysis of various internal fracture fixation devices used for treating femoral neck fractures: a comparative finite element analysis. Injury 55:111717. https:\/\/doi.org\/10.1016\/j.injury.2024.111717","journal-title":"Injury"},{"key":"3564_CR12","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2021.106409","author":"Y Xia","year":"2021","unstructured":"Xia Y, Zhang W, Hu H et al (2021) Biomechanical study of two alternative methods for the treatment of vertical femoral neck fractures \u2013 a finite element analysis. Comput Methods Programs Biomed. https:\/\/doi.org\/10.1016\/j.cmpb.2021.106409","journal-title":"Comput Methods Programs Biomed"},{"key":"3564_CR13","doi-asserted-by":"publisher","DOI":"10.1177\/21514593221141376","author":"GR Roytman","year":"2022","unstructured":"Roytman GR, Ramji AF, Beitler B et al (2022) Simulating prophylactic fixation methods for osteoporotic femoral neck fracture prevention. Geriatr Orthop Surg Rehabil. https:\/\/doi.org\/10.1177\/21514593221141376","journal-title":"Geriatr Orthop Surg Rehabil"},{"key":"3564_CR14","doi-asserted-by":"publisher","DOI":"10.1177\/21514593221135117","volume":"13","author":"JN LaMonica","year":"2022","unstructured":"LaMonica JN, Rhee B, Milligan K et al (2022) Finite element evaluation of the femoral neck system as prophylactic fixation to prevent contralateral hip fractures. Geriatr Orthop Surg Rehabil 13:21514593221135116. https:\/\/doi.org\/10.1177\/21514593221135117","journal-title":"Geriatr Orthop Surg Rehabil"},{"key":"3564_CR15","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000029450","volume":"101","author":"Y Teng","year":"2022","unstructured":"Teng Y, Zhang Y, Guo C (2022) Finite element analysis of femoral neck system in the treatment of Pauwels type III femoral neck fracture. Medicine 101:E29450. https:\/\/doi.org\/10.1097\/MD.0000000000029450","journal-title":"Medicine"},{"key":"3564_CR16","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-022-06003-3","author":"J Ma","year":"2022","unstructured":"Ma J, Zhao Z, Zhi X et al (2022) Finite element comparative analysis of three different internal fixation methods in the treatment of Pauwels type III femoral neck fractures. BMC Musculoskelet Disord. https:\/\/doi.org\/10.1186\/s12891-022-06003-3","journal-title":"BMC Musculoskelet Disord"},{"key":"3564_CR17","doi-asserted-by":"publisher","DOI":"10.1097\/bot.0000000000000739","author":"K Stoffel","year":"2017","unstructured":"Stoffel K, Zderic I, Gras F et al (2017) Biomechanical evaluation of the femoral neck system in unstable Pauwels III femoral neck fractures: a comparison with the dynamic hip screw and cannulated screws. J Orthop Trauma. https:\/\/doi.org\/10.1097\/bot.0000000000000739","journal-title":"J Orthop Trauma"},{"key":"3564_CR18","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1016\/j.jor.2022.02.016","volume":"30","author":"MR Hsu","year":"2022","unstructured":"Hsu MR, Shu HT, Luksameearunothai K et al (2022) Is there an increased risk for subtrochanteric stress fracture with the Femoral Neck System versus multiple cannulated screws fixation? J Orthop 30:127\u2013133. https:\/\/doi.org\/10.1016\/j.jor.2022.02.016","journal-title":"J Orthop"},{"key":"3564_CR19","doi-asserted-by":"publisher","DOI":"10.1186\/s10195-024-00792-0","author":"X Xie","year":"2024","unstructured":"Xie X, Bi S, Song Q et al (2024) Biomechanical evaluation of percutaneous compression plate and femoral neck system in Pauwels type III femoral neck fractures. J Orthop Traumatol. https:\/\/doi.org\/10.1186\/s10195-024-00792-0","journal-title":"J Orthop Traumatol"},{"key":"3564_CR20","doi-asserted-by":"publisher","first-page":"3155","DOI":"10.1007\/s00402-022-04551-w","volume":"143","author":"K Schuetze","year":"2023","unstructured":"Schuetze K, Burkhardt J, Pankratz C et al (2023) Is new always better: comparison of the femoral neck system and the dynamic hip screw in the treatment of femoral neck fractures. Arch Orthop Trauma Surg 143:3155\u20133161. https:\/\/doi.org\/10.1007\/s00402-022-04551-w","journal-title":"Arch Orthop Trauma Surg"},{"key":"3564_CR21","doi-asserted-by":"publisher","DOI":"10.3390\/medicina58080999","author":"Y Lu","year":"2022","unstructured":"Lu Y, Canavese F, Nan G et al (2022) Is femoral neck system a valid alternative for the treatment of displaced femoral neck fractures in adolescents? A comparative study of femoral neck system versus cannulated compression screw. Medicina (Lithuania). https:\/\/doi.org\/10.3390\/medicina58080999","journal-title":"Medicina (Lithuania)"},{"key":"3564_CR22","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1016\/j.jot.2020.06.002","volume":"24","author":"C Schopper","year":"2020","unstructured":"Schopper C, Zderic I, Menze J et al (2020) Higher stability and more predictive fixation with the femoral neck system versus Hansson pins in femoral neck fractures Pauwels II. J Orthop Translat 24:88\u201395. https:\/\/doi.org\/10.1016\/j.jot.2020.06.002","journal-title":"J Orthop Translat"},{"key":"3564_CR23","doi-asserted-by":"publisher","DOI":"10.1016\/J.INJURY.2025.112218","volume":"56","author":"YJ Zhu","year":"2025","unstructured":"Zhu YJ, Wu S, Yan JP et al (2025) Finite element analysis of the Femoral neck system for different placement positions in the fixation of Pauwels type \u2162 femoral neck fractures. Injury 56:112218. https:\/\/doi.org\/10.1016\/J.INJURY.2025.112218","journal-title":"Injury"},{"key":"3564_CR24","doi-asserted-by":"publisher","first-page":"1564","DOI":"10.1557\/jmr.1992.1564","volume":"7","author":"WC Oliver","year":"1992","unstructured":"Oliver WC, Pharr GM (1992) An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments. J Mater Res 7:1564\u20131583. https:\/\/doi.org\/10.1557\/jmr.1992.1564","journal-title":"J Mater Res"},{"key":"3564_CR25","doi-asserted-by":"publisher","DOI":"10.1016\/j.otsr.2009.10.008","author":"M G\u00fcven","year":"2010","unstructured":"G\u00fcven M, Yavuz U, Kadio\u01e7lu B et al (2010) Importance of screw position in intertrochanteric femoral fractures treated by dynamic hip screw. Orthop Traumatol Surg Res. https:\/\/doi.org\/10.1016\/j.otsr.2009.10.008","journal-title":"Orthop Traumatol Surg Res"},{"key":"3564_CR26","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199507000-00012","author":"MR Baumgaertner","year":"1995","unstructured":"Baumgaertner MR, Curtin SL, Lindskog DM, Keggi JM (1995) The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg. https:\/\/doi.org\/10.2106\/00004623-199507000-00012","journal-title":"J Bone Joint Surg"},{"key":"3564_CR27","unstructured":"ISO 7206\u20134 (2010) Implants for surgery \u2014 Partial and total hip joint prostheses \u2014 Part 4: Determination of endurance properties and performance of stemmed femoral components"},{"key":"3564_CR28","doi-asserted-by":"publisher","first-page":"566","DOI":"10.1007\/s40846-015-0085-9","volume":"35","author":"S Samsami","year":"2015","unstructured":"Samsami S, Saberi S, Sadighi S, Rouhi G (2015) Comparison of three fixation methods for femoral neck fracture in young adults: experimental and numerical investigations. J Med Biol Eng 35:566\u2013579. https:\/\/doi.org\/10.1007\/s40846-015-0085-9","journal-title":"J Med Biol Eng"},{"key":"3564_CR29","doi-asserted-by":"publisher","DOI":"10.1016\/j.rcim.2010.06.014","author":"F Nabhani","year":"2010","unstructured":"Nabhani F, Bradley EJ, Hodgson S (2010) Comparison of two tools for the measurement of interfragmentary movement in femoral neck fractures stabilised by cannulated screws. Robot Comput Integr Manuf. https:\/\/doi.org\/10.1016\/j.rcim.2010.06.014","journal-title":"Robot Comput Integr Manuf"},{"key":"3564_CR30","doi-asserted-by":"publisher","first-page":"525","DOI":"10.1016\/0021-9290(95)00084-4","volume":"29","author":"L Cristofolini","year":"1996","unstructured":"Cristofolini L, Viceconti M, Cappello A, Toni A (1996) Mechanical validation of whole bone composite femur models. J Biomech 29:525\u2013535. https:\/\/doi.org\/10.1016\/0021-9290(95)00084-4","journal-title":"J Biomech"},{"key":"3564_CR31","doi-asserted-by":"publisher","unstructured":"Rao L, Mittal S, Kabra A, et al (2025) Biomechanical evaluation of femoral neck fracture fixation based on finite element analysis. Results Eng 28:108230. https:\/\/doi.org\/10.1016\/J.RINENG.2025.108230","DOI":"10.1016\/J.RINENG.2025.108230"},{"key":"3564_CR32","doi-asserted-by":"publisher","first-page":"1923","DOI":"10.1007\/S10439-022-03013-Z\/FIGURES\/10","volume":"50","author":"P Nag","year":"2022","unstructured":"Nag P, Borgohain B, Ahmed KA et al (2022) The influence of static load and sideways impact fall on extramedullary bone plates used to treat intertrochanteric femoral fracture: a preclinical strength assessment. Ann Biomed Eng 50:1923\u20131940. https:\/\/doi.org\/10.1007\/S10439-022-03013-Z\/FIGURES\/10","journal-title":"Ann Biomed Eng"},{"key":"3564_CR33","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1016\/j.medengphy.2021.09.007","volume":"97","author":"S Zhan","year":"2021","unstructured":"Zhan S, Jiang D, Ling M et al (2021) Fixation effects of different types of cannulated screws on vertical femoral neck fracture: a finite element analysis and experimental study. Med Eng Phys 97:32\u201339. https:\/\/doi.org\/10.1016\/j.medengphy.2021.09.007","journal-title":"Med Eng Phys"},{"key":"3564_CR34","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1007\/s11517-020-02306-6","volume":"59","author":"P Nag","year":"2021","unstructured":"Nag P, Chanda S (2021) Biomechanical design prognosis of two extramedullary fixation devices for subtrochanteric femur fracture: a finite element study. Med Biol Eng Comput 59:271\u2013285. https:\/\/doi.org\/10.1007\/s11517-020-02306-6","journal-title":"Med Biol Eng Comput"},{"key":"3564_CR35","unstructured":"Eberle S, Augat P (2007) Preventing contact convergence problems in bone- implant contact models. ANSYS Conference 25th CADHEM Users Meeting 2007, pp 21\u201325"},{"key":"3564_CR36","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2004.05.022","author":"MO Heller","year":"2005","unstructured":"Heller MO, Bergmann G, Kassi JP et al (2005) Determination of muscle loading at the hip joint for use in pre-clinical testing. J Biomech. https:\/\/doi.org\/10.1016\/j.jbiomech.2004.05.022","journal-title":"J Biomech"},{"key":"3564_CR37","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1097\/00003086-200302000-00028","volume":"407","author":"T McConnell","year":"2003","unstructured":"McConnell T, Tornetta P, Benson E, Manuel J (2003) Gluteus medius tendon injury during reaming for gamma nail insertion. Clin Orthop Relat Res 407:199\u2013202. https:\/\/doi.org\/10.1097\/00003086-200302000-00028","journal-title":"Clin Orthop Relat Res"},{"key":"3564_CR38","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1016\/j.arthro.2007.11.015","volume":"24","author":"WJ Robertson","year":"2008","unstructured":"Robertson WJ, Gardner MJ, Barker JU et al (2008) Anatomy and dimensions of the gluteus medius tendon insertion. Arthroscopy 24:130\u2013136. https:\/\/doi.org\/10.1016\/j.arthro.2007.11.015","journal-title":"Arthroscopy"},{"key":"3564_CR39","doi-asserted-by":"publisher","DOI":"10.1177\/11795972231166240","volume":"14","author":"JE Johnson","year":"2023","unstructured":"Johnson JE, Brouillette MJ, Miller BJ, Goetz JE (2023) Finite element model-computed mechanical behavior of femurs with metastatic disease varies between physiologic and idealized loading simulations. Biomed Eng Comput Biol 14:11795972231166240. https:\/\/doi.org\/10.1177\/11795972231166240","journal-title":"Biomed Eng Comput Biol"},{"key":"3564_CR40","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2012.12.005","author":"JD Reed","year":"2013","unstructured":"Reed JD, Stanbury SJ, Menorca RM, Elfar JC (2013) The emerging utility of composite bone models in biomechanical studies of the hand and upper extremity. J Hand Surg. https:\/\/doi.org\/10.1016\/j.jhsa.2012.12.005","journal-title":"J Hand Surg"},{"key":"3564_CR41","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1177\/0954411915591617","volume":"229","author":"S Chanda","year":"2015","unstructured":"Chanda S, Dickinson A, Gupta S, Browne M (2015) Full-field in vitro measurements and in silico predictions of strain shielding in the implanted femur after total hip arthroplasty. Proc Inst Mech Eng H 229:549\u2013559. https:\/\/doi.org\/10.1177\/0954411915591617","journal-title":"Proc Inst Mech Eng H"},{"key":"3564_CR42","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2024.106296","volume":"117","author":"P Brzozowski","year":"2024","unstructured":"Brzozowski P, Inculet C, Schemitsch EH, Zdero R (2024) Biomechanical testing of a computationally optimized far cortical locking plate versus traditional implants for distal femur fracture repair. Clin Biomech 117:106296. https:\/\/doi.org\/10.1016\/j.clinbiomech.2024.106296","journal-title":"Clin Biomech"},{"key":"3564_CR43","unstructured":"GENERAL CATALOG - Sawbones\/Pacific Research Labs (2025) - PDF Catalogs | Technical Documentation. https:\/\/pdf.medicalexpo.com\/pdf\/sawbones-pacific-research-labs\/general-catalog\/103604-179594.html. Accessed 11 Sep 2025"},{"key":"3564_CR44","doi-asserted-by":"publisher","unstructured":"Bayraktar HH, Morgan EF, Niebur GL, et al (2004) Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue. J Biomech 37. https:\/\/doi.org\/10.1016\/S0021-9290(03)00257-4","DOI":"10.1016\/S0021-9290(03)00257-4"},{"key":"3564_CR45","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijmecsci.2019.105213","author":"R Belda","year":"2020","unstructured":"Belda R, Palomar M, Peris-Serra JL et al (2020) Compression failure characterization of cancellous bone combining experimental testing, digital image correlation and finite element modeling. Int J Mech Sci. https:\/\/doi.org\/10.1016\/j.ijmecsci.2019.105213","journal-title":"Int J Mech Sci"},{"key":"3564_CR46","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-023-07110-5","author":"X Fan","year":"2024","unstructured":"Fan X, Zhou Y, Dai S et al (2024) Bio-mechanical effects of femoral neck system versus cannulated screws on treating young patients with Pauwels type III femoral neck fractures: a finite element analysis. BMC Musculoskelet Disord. https:\/\/doi.org\/10.1186\/s12891-023-07110-5","journal-title":"BMC Musculoskelet Disord"},{"key":"3564_CR47","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1186\/s12891-023-06872-2","volume":"24","author":"JC Fisher","year":"2023","unstructured":"Fisher JC, Gerzina C, Rush K, Caroom C (2023) Subtrochanteric fracture after femoral neck system of femoral neck fractures: a report of four cases. BMC Musculoskelet Disord 24:749. https:\/\/doi.org\/10.1186\/s12891-023-06872-2","journal-title":"BMC Musculoskelet Disord"},{"key":"3564_CR48","doi-asserted-by":"publisher","first-page":"770","DOI":"10.1097\/CORR.0000000000000945","volume":"478","author":"EK Crump","year":"2020","unstructured":"Crump EK, Quacinella M, Deafenbaugh BK (2020) Does screw location affect the risk of subtrochanteric femur fracture after femoral neck fixation? A biomechanical study. Clin Orthop Relat Res 478:770\u2013776. https:\/\/doi.org\/10.1097\/CORR.0000000000000945","journal-title":"Clin Orthop Relat Res"},{"key":"3564_CR49","doi-asserted-by":"publisher","first-page":"1743","DOI":"10.1016\/J.INJURY.2017.05.013","volume":"48","author":"B Kemker","year":"2017","unstructured":"Kemker B, Magone K, Owen J et al (2017) A sliding hip screw augmented with 2 screws is biomechanically similar to an inverted triad of cannulated screws in repair of a Pauwels type-III fracture. Injury 48:1743\u20131748. https:\/\/doi.org\/10.1016\/J.INJURY.2017.05.013","journal-title":"Injury"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-026-03564-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11517-026-03564-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-026-03564-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T08:06:47Z","timestamp":1777536407000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11517-026-03564-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,30]]},"references-count":49,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,5]]}},"alternative-id":["3564"],"URL":"https:\/\/doi.org\/10.1007\/s11517-026-03564-6","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,30]]},"assertion":[{"value":"29 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 March 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval and consent to participate"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}