{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2022,4,4]],"date-time":"2022-04-04T00:18:04Z","timestamp":1649031484546},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"3-4","license":[{"start":{"date-parts":[[2007,10,24]],"date-time":"2007-10-24T00:00:00Z","timestamp":1193184000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2007,12]]},"DOI":"10.1007\/s11548-007-0128-y","type":"journal-article","created":{"date-parts":[[2007,10,23]],"date-time":"2007-10-23T08:25:12Z","timestamp":1193127912000},"page":"183-190","source":"Crossref","is-referenced-by-count":4,"title":["Comparison of performance between rigid and non-rigid software registering CT to FDG-PET"],"prefix":"10.1007","volume":"2","author":[{"given":"Gabriele","family":"Wolz","sequence":"first","affiliation":[]},{"given":"Anton","family":"N\u00f6mayr","sequence":"additional","affiliation":[]},{"given":"Torsten","family":"Hothorn","sequence":"additional","affiliation":[]},{"given":"Joachim","family":"Hornegger","sequence":"additional","affiliation":[]},{"given":"Wolfgang","family":"R\u00f6mer","sequence":"additional","affiliation":[]},{"given":"Werner","family":"Bautz","sequence":"additional","affiliation":[]},{"given":"Torsten","family":"Kuwert","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2007,10,24]]},"reference":[{"key":"128_CR1","doi-asserted-by":"crossref","first-page":"1456","DOI":"10.1007\/s00259-004-1593-y","volume":"31","author":"P Reinartz","year":"2004","unstructured":"Reinartz P, Wieres F-J, Schneider W, Schur A and Buell U (2004). Side-by-side reading of PET and CT scans in oncology: which patients might profit from integrated PET\/CT. Eur J Nucl Med Mol Imaging 31: 1456\u20131461","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"128_CR2","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1007\/s00259-001-0700-6","volume":"29","author":"BF Hutton","year":"2002","unstructured":"Hutton BF, Braun M, Thurfjell L and Lau DYH (2002). Image registration: an essential tool for nuclear medicine. Eur J Nucl Med 29: 559\u2013577","journal-title":"Eur J Nucl Med"},{"key":"128_CR3","doi-asserted-by":"crossref","first-page":"2500","DOI":"10.1056\/NEJMoa022136","volume":"348","author":"D Lardinois","year":"2003","unstructured":"Lardinois D, Weder W and Hany TF et al (2003). Staging of non- small-cell lung cancer with integrated positron-emission tomography and computed tomography. N Engl J Med 348: 2500\u20132507","journal-title":"N Engl J Med"},{"key":"128_CR4","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1053\/snuc.2003.127314","volume":"33","author":"DW Townsend","year":"2003","unstructured":"Townsend DW, Beyer T and Blodgett TM (2003). PET\/CT scanners: a hardware approach to image fusion. Sem Nucl Med 33: 193\u2013204","journal-title":"Sem Nucl Med"},{"key":"128_CR5","first-page":"1369","volume":"41","author":"T Beyer","year":"2000","unstructured":"Beyer T, Townsend DW and Brun T et al (2000). A combined PET\/CT scanner for clinical oncology. J Nucl Med 41: 1369\u20131379","journal-title":"J Nucl Med"},{"key":"128_CR6","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1148\/radiol.2252011568","volume":"225","author":"TF Hany","year":"2002","unstructured":"Hany TF, Steinert HC, Goerres GW, Buck A and von Schulthess GK (2002). PET diagnostic accuracy: improvement with in-line PET-CT system: initial results. Radiology 225: 575\u2013581","journal-title":"Radiology"},{"key":"128_CR7","first-page":"587","volume":"46","author":"JH Kim","year":"2005","unstructured":"Kim JH, Czernin J and Allen-Auerbach MS et al (2005). Comparison between 18F-FDG PET, in-line PET\/CT, and software fusion for restaging of recurrent colorectal cancer. J Nucl Med 46: 587\u2013595","journal-title":"J Nucl Med"},{"key":"128_CR8","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1016\/j.mibio.2004.08.004","volume":"6","author":"M Allen-Auerbach","year":"2004","unstructured":"Allen-Auerbach M, Quon A and Weber WA et al (2004). Comparison between 2-deoxy-2\u201318ffluoro-D-glucose positron emission tomography\/computed tomography hardware fusion for staging of patients with lymphoma. Mol Imaging Biol 6: 411\u2013416","journal-title":"Mol Imaging Biol"},{"key":"128_CR9","doi-asserted-by":"crossref","first-page":"644","DOI":"10.1097\/00004728-200007000-00024","volume":"24","author":"GJ Schaffler","year":"2000","unstructured":"Schaffler GJ, Groell R and Schoellnast H et al (2000). Digital image fusion of CT and PET data sets-clinical value in abdominal\/pelvic malignancies. J Comput Assist Tomogr 24: 644\u2013647","journal-title":"J Comput Assist Tomogr"},{"key":"128_CR10","doi-asserted-by":"crossref","first-page":"1674","DOI":"10.1007\/s00259-003-1300-4","volume":"30","author":"CC Tsai","year":"2003","unstructured":"Tsai CC, Tsai CS and Ng KK et al (2003). The impact of image fusion in resolving discrepant findings between FDG-PET and MRI\/CT in patients with gynaecological cancers. Eur J Nucl Med Mol Imaging 30: 1674\u20131683","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"128_CR11","first-page":"1279","volume":"45","author":"AJ Lemke","year":"2004","unstructured":"Lemke AJ, Niehues SM and Hosten N et al (2004). Retrospective digital fusion of multidetector CT and 18F-FDG PET: clinical value in pancreatic lesions\u2013a prospective study with 104 patients. J Nucl Med 45: 1279\u20131286","journal-title":"J Nucl Med"},{"key":"128_CR12","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1016\/S0003-4975(02)03693-7","volume":"74","author":"TA D\u2019amico","year":"2002","unstructured":"D\u2019amico TA, Wong TZ, Harpole DH, Brown SD and Coleman RE (2002). Impact of computed tomography-positron emission tomography fusion in staging patients with thoracic malignancies. Ann Thorac Surg 74: 160\u2013163","journal-title":"Ann Thorac Surg"},{"key":"128_CR13","first-page":"267","volume":"49","author":"G Rizzo","year":"2005","unstructured":"Rizzo G, Castiglioni I and Arienti R et al (2005). Automatic registration of PET and CT studies for clinical use in thoracic and abdominal conformal radiotherapy. QJ Nucl Med Mol Imaging 49: 267\u2013279","journal-title":"QJ Nucl Med Mol Imaging"},{"key":"128_CR14","doi-asserted-by":"crossref","first-page":"2289","DOI":"10.1016\/S0012-3692(15)52634-2","volume":"128","author":"BS Halpern","year":"2005","unstructured":"Halpern BS, Schiepers C and Weber WA et al (2005). Presurgical staging of non-small cell lung cancer: positron emission tomography, integrated positron emission tomography\/CT, and software image fusion. Chest 128: 2289\u20132297","journal-title":"Chest"},{"key":"128_CR15","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1055\/s-0038-1625738","volume":"45","author":"W R\u00f6mer","year":"2006","unstructured":"R\u00f6mer W, N\u00f6mayr A and Greess H et al (2006). Retrospective interactive rigid fusion of F-18 FDG-PET and CT: additional diagnostic information in melanoma patients. Nuklearmedizin 45: 88\u201395","journal-title":"Nuklearmedizin"},{"key":"128_CR16","doi-asserted-by":"crossref","first-page":"1083","DOI":"10.1118\/1.1688041","volume":"31","author":"WC Lavely","year":"2004","unstructured":"Lavely WC, Scarfone C and Cevikalp H et al (2004). Phantom validation of coregistration of PET and CT for image-guided radiotherapy. Med Phys 31: 1083\u20131092","journal-title":"Med Phys"},{"key":"128_CR17","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1002\/(SICI)1522-712X(1995)1:6<300::AID-IGS2>3.0.CO;2-E","volume":"1","author":"GE Kraus","year":"1995","unstructured":"Kraus GE, Bernstein TW, Satter M, Ezzeddine B, Hwang DR and Mantil J (1995). A technique utilizing positron emission tomography and magnetic resonance\/computed tomography image fusion to aid in surgical navigation and tumor volume determination. J Image Guid Surg 1: 300\u2013307","journal-title":"J Image Guid Surg"},{"key":"128_CR18","first-page":"156","volume":"33","author":"W Sureshbabu","year":"2005","unstructured":"Sureshbabu W and Mawlawi O (2005). PET\/CT imaging artifacts. J Nucl Med Technol 33: 156\u2013161","journal-title":"J Nucl Med Technol"},{"key":"128_CR19","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1007\/s00259-002-1055-3","volume":"30","author":"C Cohade","year":"2003","unstructured":"Cohade C, Osman M, Marshall LN and Wahl RN (2003). PET-CT: accuracy of PET and CT spatial registration of lung lesions. Eur J Nucl Med Mol Imaging 30: 721\u2013726","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"128_CR20","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1007\/s00259-001-0710-4","volume":"29","author":"GW Goerres","year":"2002","unstructured":"Goerres GW, Kamel E, Heidelberg TNH, Schwitter MR, Burger C and von Schulthess GK (2002). PET-CT image co-registration in the thorax: influence of respiration. Eur J Nucl Med Mol Imaging 29: 351\u2013360","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"128_CR21","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1055\/s-0038-1623925","volume":"44","author":"A N\u00f6mayr","year":"2005","unstructured":"N\u00f6mayr A, R\u00f6mer W and Hothorn T et al (2005). Anatomical accuracy of lesion localization: retrospective interactive rigid image registration between 18F-FDG-PET and X-ray CT. Nuklearmedizin 44: 49\u201355","journal-title":"Nuklearmedizin"},{"key":"128_CR22","doi-asserted-by":"crossref","first-page":"2662","DOI":"10.1109\/TNS.2004.835778","volume":"51","author":"H Herzog","year":"2004","unstructured":"Herzog H, Tellmann L, Hocke C, Pietrzyk U, Casey ME and Kuwert T (2004). NEMA NU2\u20132001 guided performance evaluation of four Siemens ECAT PET-Scanners. IEEE Trans Nucl Sci 51: 2662\u20132669","journal-title":"IEEE Trans Nucl Sci"},{"key":"128_CR23","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1023\/A:1020830525823","volume":"50","author":"G Hermosillo","year":"2002","unstructured":"Hermosillo G, Chefd\u2019Hotel C and Faugeras O (2002). Variational methods for multi-modal image matching. Int J Comput Vision 50: 329\u2013343","journal-title":"Int J Comput Vision"},{"key":"128_CR24","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1117\/12.594577","volume":"5747","author":"DA Hahn","year":"2005","unstructured":"Hahn DA, Hornegger J, Bautz W, Kuwert T and R\u00f6mer W (2005). Unbiased rigid registration using transfer functions. Proc SPIE 5747: 151\u2013162","journal-title":"Proc SPIE"},{"key":"128_CR25","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1055\/s-0037-1616625","volume":"46","author":"G Wolz","year":"2007","unstructured":"Wolz G, N\u00f6mayr A and Hothorn T et al (2007). Anatomical accuracy of interactive and automated rigid registration between X-ray CT and FDG-PET. Nuklearmedizin 46: 43\u201348","journal-title":"Nuklearmedizin"},{"key":"128_CR26","doi-asserted-by":"crossref","DOI":"10.1007\/978-1-4419-0318-1","volume-title":"Mixed-effects models in S and S-PLUS","author":"JC Pinheiro","year":"2000","unstructured":"Pinheiro JC and Bates M (2000). Mixed-effects models in S and S-PLUS. Springer, New York"},{"key":"128_CR27","unstructured":"R Development Core Team (2006) R: A language and environment for statistical computing. R Foundation for statistical Computing, Vienna, Austria. http:\/\/www.R-project.org"},{"key":"128_CR28","unstructured":"Bates M, Sakar D (2006) lme4: Linear mixed-effects models using S4 classes. R package version 0.995\u20132. http:\/\/CRAN.R-project.org"},{"key":"128_CR29","first-page":"155","volume":"17","author":"H Inagaki","year":"1999","unstructured":"Inagaki H, Kato T and Tadokoro M et al (1999). Interactive fusion of three-dimensional images of upper abdominal CT and FDG PET with no body surface markers. Radiat Med 17: 155\u2013163","journal-title":"Radiat Med"},{"key":"128_CR30","doi-asserted-by":"crossref","first-page":"1960","DOI":"10.2214\/ajr.184.6.01841960","volume":"184","author":"Y Nakamoto","year":"2005","unstructured":"Nakamoto Y, Sakamoto S and Okada T et al (2005). Accuracy of image fusion using a fixation device for whole-body cancer imaging. AJR Am J Roentgenol 184: 1960\u20131966","journal-title":"AJR Am J Roentgenol"},{"key":"128_CR31","first-page":"1184","volume":"43","author":"J Skalski","year":"2002","unstructured":"Skalski J, Wahl RL and Meyer CR (2002). Comparison of mutual information-based warping accuracy for fusing body CT and PET by 2 methods: CT mapped onto PET emission scan versus CT mapped onto PET transmission scan. J Nucl Med 43: 1184\u20131187","journal-title":"J Nucl Med"},{"key":"128_CR32","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1016\/S1361-8415(97)85010-4","volume":"1","author":"CR Meyer","year":"1997","unstructured":"Meyer CR, Boes JL and Kim B et al (1997). Demonstration of accuracy and clinical versatility of mutual information for automatic multimodality image fusion using affine and thin-plate spline warped geometric deformations. Med Image Analysis 1: 195\u2013206","journal-title":"Med Image Analysis"},{"key":"128_CR33","first-page":"1488","volume":"46","author":"R Shekhar","year":"2005","unstructured":"Shekhar R, Walimbe V and Raja S et al (2005). Automated 3-dimensional elastic registration of whole-body PET and CT from separate or combined scanners. J Nucl Med 46: 1488\u20131496","journal-title":"J Nucl Med"},{"key":"128_CR34","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1109\/TMI.2003.809072","volume":"22","author":"D Mattes","year":"2003","unstructured":"Mattes D, Haynor DR, Vesselle H, Lewellen TK and Eubank W (2003). PET- CT image registration in the chest using free-form deformations. IEEE Trans Med Imaging 22: 120\u2013128","journal-title":"IEEE Trans Med Imaging"},{"key":"128_CR35","first-page":"1156","volume":"44","author":"PJ Slomka","year":"2003","unstructured":"Slomka PJ, Dey D, Przetak C, Aladl UE and Baum RP (2003). Automated 3-dimensonal registration of stand-alone 18F-FDG whole-body PET with CT. J Nucl Med 44: 1156\u20131167","journal-title":"J Nucl Med"},{"key":"128_CR36","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1148\/radiol.2372041719","volume":"237","author":"V Krishnasetty","year":"2005","unstructured":"Krishnasetty V, Fischman AJ, Halpern EL and Aquino SL (2005). Comparison of alignment of computer-registered data sets: combined PET\/CT versus independent PET and CT of the thorax. Radiology 237: 635\u2013639","journal-title":"Radiology"},{"key":"128_CR37","doi-asserted-by":"crossref","first-page":"734","DOI":"10.1007\/s00330-002-1720-8","volume":"13","author":"GW Goerres","year":"2003","unstructured":"Goerres GW, Burger C, Schwitter MR, Heidelberg TN, Seifert B and von Schulthess GK (2003). PET\/CT of the abdomen: optimizing the patient breathing pattern. Eur Radiol 13: 734\u2013739","journal-title":"Eur Radiol"},{"key":"128_CR38","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1097\/00004728-199707000-00007","volume":"21","author":"J West","year":"1997","unstructured":"West J, Fitzpatrick JM and Wang MY et al (1997). Comparison and evaluation of retrospective intermodality brain image registration techniques. J Comput Assist Tomogr 21: 554\u2013566","journal-title":"J Comput Assist Tomogr"},{"key":"128_CR39","unstructured":"G\u00fctter C, Xu C, Sauer F et\u00a0al (2005) Non-rigid multi-modal image registration using Kullback\u2013Leibler divergence MICCAI \u201905: Proceedings of the 8th International Conference on Medical Image Computing and Computer Assisted Intervention\u2014Part II, vol 3750. Springer, Heidelberg, pp 255\u2013262"},{"key":"128_CR40","first-page":"860","volume":"6144","author":"F J\u00e4ger","year":"2006","unstructured":"J\u00e4ger F, Han J, Hornegger J and Kuwert T (2006). A variational approach to spatially dependent non-rigid registration. Proc SPIE 6144: 860\u2013869","journal-title":"Proc SPIE"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-007-0128-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-007-0128-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-007-0128-y","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,1]],"date-time":"2019-06-01T12:35:44Z","timestamp":1559392544000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-007-0128-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,10,24]]},"references-count":40,"journal-issue":{"issue":"3-4","published-print":{"date-parts":[[2007,12]]}},"alternative-id":["128"],"URL":"https:\/\/doi.org\/10.1007\/s11548-007-0128-y","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,10,24]]}}}