{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,16]],"date-time":"2026-01-16T12:42:13Z","timestamp":1768567333250,"version":"3.49.0"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2008,11,15]],"date-time":"2008-11-15T00:00:00Z","timestamp":1226707200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2009,3]]},"DOI":"10.1007\/s11548-008-0278-6","type":"journal-article","created":{"date-parts":[[2008,11,14]],"date-time":"2008-11-14T03:56:55Z","timestamp":1226635015000},"page":"113-123","source":"Crossref","is-referenced-by-count":28,"title":["Inside the beating heart: an in vivo feasibility study on fusing pre- and intra-operative imaging for minimally invasive therapy"],"prefix":"10.1007","volume":"4","author":[{"given":"Cristian A.","family":"Linte","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John","family":"Moore","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chris","family":"Wedlake","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel","family":"Bainbridge","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G\u00e9rard M.","family":"Guiraudon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Douglas L.","family":"Jones","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Terry M.","family":"Peters","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2008,11,15]]},"reference":[{"key":"278_CR1","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1510\/icvts.2007.154567","volume":"6","author":"G Guiraudon","year":"2007","unstructured":"Guiraudon G, Jones D, Bainbridge D, Peters T (2007) Mitral valve implantation using off-pump closed beating intracardiac surgery: a feasability study. Interact Cardiovasc Thorac Surg 6: 603\u2013607","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"278_CR2","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1016\/S1569-9293(02)00117-2","volume":"2","author":"L Segesser von","year":"2003","unstructured":"von Segesser L, Tozzi P, Augstburger M, Corno A (2003) Working heart off-pump cardiac repair (OPCARE)\u2014the next step in robotic surgery?. Interact Cardiovasc Thorac Surg 2: 120\u2013124","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"278_CR3","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1016\/j.jtcvs.2004.06.011","volume":"128","author":"Y Suematsu","year":"2004","unstructured":"Suematsu Y, Marx GR, Stoll JA, Dupont PE, Cleveland RO, Howe RD, Triedman JK, Mihaljevic T, Mora BN, Savord BJ, Salgo IS, del Nido PJ (2004) Three-dimensional echo-guided beating-heart surgery without cardiopulmonary bypass: a feasibility study. J Thorac Cardiovasc Surg 128: 579\u2013587","journal-title":"J Thorac Cardiovasc Surg"},{"key":"278_CR4","doi-asserted-by":"crossref","first-page":"958","DOI":"10.1002\/mrm.21044","volume":"56","author":"ER McVeigh","year":"2006","unstructured":"McVeigh ER, Guttman MA, Lederman RJ, Li M, Kocatruk O, Hunt T, Kozlov S, Horvath KA (2006) Real-time interactive MRI-guided cardiac surgery: aortic valve replacement using a direct apical approach. Magn Reson Med 56: 958\u2013964","journal-title":"Magn Reson Med"},{"key":"278_CR5","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1002\/rcs.70","volume":"2","author":"M Hastenteufel","year":"2006","unstructured":"Hastenteufel M, Yang S, Christoph C, Vetter M, Meinzer H, Wolf I (2006) Image-based guidance for minimally invasive surgical atrial fibrillation ablation. Int J Med Robotics Comput Assist Surg 2: 60\u201369","journal-title":"Int J Med Robotics Comput Assist Surg"},{"key":"278_CR6","doi-asserted-by":"crossref","first-page":"1512","DOI":"10.1109\/TMI.2005.857661","volume":"24","author":"S DeBuck","year":"2005","unstructured":"DeBuck S, Maes A, Ecto J, Bogaert J, Dymarkowski S, Heidbnchel H, Suetens P (2005) An augmented reality system for patient-specific guidance of cardiac catheter ablation procedures. IEEE Trans Med Imaging 24: 1512\u20131524","journal-title":"IEEE Trans Med Imaging"},{"key":"278_CR7","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1111\/j.1540-8167.2006.00425.x","volume":"17","author":"J Dong","year":"2006","unstructured":"Dong J, Dickfeld T, Dalal D, Cheema A, Vasamreddy C, Henrikson C, Marine J, Halperin H, Berger R, Lima J, Bluemke D, Calkins H (2006) Initial experience in the use of integrated electroanatomic mapping with three-dimensional MR\/CT images to guide catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol 17: 459\u2013466","journal-title":"J Cardiovasc Electrophysiol"},{"key":"278_CR8","first-page":"100","volume":"20","author":"A Vahanian","year":"2005","unstructured":"Vahanian A, Acar C (2005) Percutaneaous valve procedures: what is the future?. Curr Opin Cardiol 20: 100\u2013106","journal-title":"Curr Opin Cardiol"},{"key":"278_CR9","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1016\/j.echo.2005.09.008","volume":"19","author":"TZ Naqvi","year":"2006","unstructured":"Naqvi TZ, Zarbatany D (2006) Intracardiac echocardiography for percutaneous mitral valve repair in a swine model. J Am Soc Echocardiogr 19: 147\u2013153","journal-title":"J Am Soc Echocardiogr"},{"key":"278_CR10","doi-asserted-by":"crossref","first-page":"1221","DOI":"10.1016\/j.acra.2005.05.024","volume":"12","author":"ER McVeigh","year":"2005","unstructured":"McVeigh ER, Guttman MA, Kellman P, Raval AA, Lederman RJ (2005) Real-time, interactive MRI for cardiovascular interventions. Acad Radiol 12: 1221\u20131227","journal-title":"Acad Radiol"},{"key":"278_CR11","doi-asserted-by":"crossref","first-page":"922","DOI":"10.1109\/TMI.2006.876166","volume":"25","author":"G Lauritsch","year":"2006","unstructured":"Lauritsch G, Boese J, Wigstr\u00f6m L, Kemeth H, Fahrig R (2006) Towards cardiac C-arm computed tomography. IEEE Trans Med Imaging 25: 922\u2013934","journal-title":"IEEE Trans Med Imaging"},{"key":"278_CR12","doi-asserted-by":"crossref","first-page":"1348","DOI":"10.1016\/j.jtcvs.2005.06.043","volume":"130","author":"Y Suematsu","year":"2005","unstructured":"Suematsu Y, Martinez JF, Wolf BK, Marx GR, Stoll JA, Dupont PE, Howe RD, Triedman JK, del Nido PJ (2005) Three-dimensional echo-guided beating-heart surgery without cardiopulmonary bypass: atrial septal defect closure in a swine model. J Cardiovasc Thorac Surg 130: 1348\u20131357","journal-title":"J Cardiovasc Thorac Surg"},{"key":"278_CR13","doi-asserted-by":"crossref","first-page":"82","DOI":"10.3109\/10929080801951160","volume":"13","author":"CA Linte","year":"2008","unstructured":"Linte CA, Moore J, Wiles AD, Wedlake C, Peters TM (2008) Virtual reality-enhanced ultrasound guidance: a novel technique for intracardiac interventions. Comput Aided Surg 13: 82\u201394","journal-title":"Comput Aided Surg"},{"key":"278_CR14","doi-asserted-by":"crossref","unstructured":"Linte CA, Wiles AD, Hill N, Moore J, Wedlake C, Guiraudon GM, Jones DL, Bainbridge D, Peters TM (2007) An augmented reality environment for image-guidance of off-pump mitral valve implantation. In: Medical imaging 2007: visualization and image-guided procedures. Proc of SPIE, vol 6509, 65090N-12","DOI":"10.1117\/12.711041"},{"key":"278_CR15","doi-asserted-by":"crossref","unstructured":"Wiles AD, Guiraudon GM, Moore J, Wedlake C, Linte CA, Jones DL, Bainbridge D, Peters TM (2007) Navigation accuracy for an intracardiac procedure using virtual reality-enhanced ultrasound. In: Medical imaging 2007: visualization and image-guided procedures. Proc of SPIE, vol 6509, 61410W-10","DOI":"10.1117\/12.711532"},{"key":"278_CR16","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1002\/jmri.20364","volume":"22","author":"R Smol\u00edkov\u00e1-Wqchowiak","year":"2003","unstructured":"Smol\u00edkov\u00e1-Wqchowiak R, Wachowiak MP, Fenster A, Drangova M (2003) Registration of tow-dimensional cardiac images to preprocedural three-dimensional images for interventional applications. J Magn Reson Imaging 22: 219\u2013228","journal-title":"J Magn Reson Imaging"},{"key":"278_CR17","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1016\/j.media.2004.06.014","volume":"8","author":"M Wierzbicki","year":"2004","unstructured":"Wierzbicki M, Drangova M, Guiraudon GM, Peters TM (2004) Validation of dynamic heart models obtained using non-linear registration for virtual reality training, planning, and guidance of minimally invasive cardiac surgeries. Med Image Anal 8: 387\u2013401","journal-title":"Med Image Anal"},{"key":"278_CR18","doi-asserted-by":"crossref","unstructured":"Schroeder WJ, Zarge JA, Lorensen WE (1992) Decimation of triangle meshes. In: Computer graphics\u2014SIGGRAPH 92, pp 65\u201370","DOI":"10.1145\/133994.134010"},{"key":"278_CR19","doi-asserted-by":"crossref","unstructured":"Wierzbicki M, Peters TM (2003) Determining epicardial surface motion using elastic registration: towards virtual reality guidance of minimally-invasive cardiac interventions. In: Proc of med image comput comput assist interv. Lect notes comput sci, vol 2878, pp 722\u2013729","DOI":"10.1007\/978-3-540-39899-8_88"},{"key":"278_CR20","unstructured":"Gobbi DG, Comeau RM, Peters TM (1999) Ultrasound probe tracking for real-time ultrasound\/MRI overlay and visualization of brain shift. In: Lecture notes in computer science. Proc of med image comput comput assist interv, vol 1679, pp 920\u2013927"},{"key":"278_CR21","first-page":"475","volume":"1","author":"CA Linte","year":"2007","unstructured":"Linte CA, Wierzbicki M, Moore J, Guiraudon GM, Jones DL, Peters TM (2007) On enhancing planning and navigation of beating-heart mitral valve surgery using pre-operative cardiac models. Proc IEEE Eng Med Biol Soc 1: 475\u2013478","journal-title":"Proc IEEE Eng Med Biol Soc"},{"key":"278_CR22","unstructured":"Guiraudon GM (2005) Universal cardiac introducer. Patent Application US 2005\/0137609 A1, Appl. No. 10\/736,786"},{"key":"278_CR23","unstructured":"Wierzbicki M (2006) Subject-specific models of the heart from 4D images. PhD dissertation, University of Western Ontario, Canada"},{"key":"278_CR24","doi-asserted-by":"crossref","unstructured":"Linte CA, Wierzbicki M, Moore J, Guiraudon GM, Little SH, Peters TM (2007) Towards subject-specific models of the dynamic heart for mitral valve surgery. In: Proc of med image comput comput assist interv. Lect notes comput sci, vol 4792, pp 94\u2013101","DOI":"10.1007\/978-3-540-75759-7_12"},{"key":"278_CR25","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1109\/TRO.2007.895077","volume":"23","author":"O Bebek","year":"2007","unstructured":"Bebek O, Cavusoglu MC (2007) Intelligent control algorithms for robotic-assisted beating heart surgery. IEEE Trans Rob Autom 23: 468\u2013480","journal-title":"IEEE Trans Rob Autom"},{"key":"278_CR26","first-page":"823","volume":"1","author":"O Bebek","year":"2006","unstructured":"Bebek O, Cavusoglu MC (2006) Model based control algorithms for robotic assisted beating heart surgery. Proc IEEE Eng Med Biol Soc 1: 823\u2013828","journal-title":"Proc IEEE Eng Med Biol Soc"},{"key":"278_CR27","doi-asserted-by":"crossref","first-page":"267","DOI":"10.3109\/10929080600970916","volume":"11","author":"L Cuvillon","year":"2006","unstructured":"Cuvillon L, Gangloff J, De Mathelin M, Forgione A (2006) Towards robotized beating heart tecabg: assessment of the heart dynamics using high-speed vision. Comput Aided Surg 11: 267\u2013277","journal-title":"Comput Aided Surg"},{"key":"278_CR28","doi-asserted-by":"crossref","unstructured":"Kettler DT, Plowes RD, Novotny PM, Vasilyev NV, del Nido PJ, Howe RD (2007) An active motion compensation instrument for beating heart mitral valve surgery. In: Proc of IEEE\/RSJ international conference on intelligent robots and systems, vol 1, pp 1290\u20131295","DOI":"10.1109\/IROS.2007.4399543"},{"key":"278_CR29","unstructured":"Vogt S, Khamene A, Niemann H, Sauer F (2004) An AR system with intuitive user interface for manipulation and visualization of 3D medical data. In: Proceedings of medicine meets virtual reality. Stud health technol inform, vol 98, pp 397\u2013403"},{"key":"278_CR30","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1088\/0031-9155\/48\/3\/402","volume":"48","author":"W Birkfellner","year":"2003","unstructured":"Birkfellner W, Figl M, Matula C, Hummel J, Hanel R, Imhof H, Wanschitz F, Wagner A, Watzinger F, Bergmann H (2003) Computer-enhanced stereoscopic vision in a head-mounted operating binocular. Phys Med Biol 48: 49\u201357","journal-title":"Phys Med Biol"},{"key":"278_CR31","doi-asserted-by":"crossref","unstructured":"Linte CA, Wiles A, Moore J et al (2008) Virtual reality-enhanced ultrasound guidance for atrial ablation: in vitro epicardial study. In: Lect notes comput sci, vol 5242, pp 644\u2013651","DOI":"10.1007\/978-3-540-85990-1_77"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-008-0278-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-008-0278-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-008-0278-6","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,1]],"date-time":"2019-06-01T12:35:46Z","timestamp":1559392546000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-008-0278-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,11,15]]},"references-count":31,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2009,3]]}},"alternative-id":["278"],"URL":"https:\/\/doi.org\/10.1007\/s11548-008-0278-6","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,11,15]]}}}