{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T12:03:20Z","timestamp":1769169800943,"version":"3.49.0"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2010,7,22]],"date-time":"2010-07-22T00:00:00Z","timestamp":1279756800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2011,5]]},"DOI":"10.1007\/s11548-010-0511-y","type":"journal-article","created":{"date-parts":[[2010,7,21]],"date-time":"2010-07-21T09:40:26Z","timestamp":1279705226000},"page":"319-327","source":"Crossref","is-referenced-by-count":12,"title":["Surgical stent planning: simulation parameter study for models based on DICOM standards"],"prefix":"10.1007","volume":"6","author":[{"given":"S.","family":"Scherer","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.","family":"Treichel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N.","family":"Ritter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.","family":"Triebel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"W. G.","family":"Drossel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"O.","family":"Burgert","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2010,7,22]]},"reference":[{"issue":"6","key":"511_CR1","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1016\/j.ejvs.2009.02.017","volume":"37","author":"D Cin\u00e0","year":"2009","unstructured":"Cin\u00e0 D, Grant G, Peterson M, Campbell V, Garrido-Olivares L, Cin\u00e0 C (2009) A study of pullout forces of the components of modular multi-manufacturer hybrid endografts used for aortic aneurysm repair. Eur J Vasc Endovasc Surg 37(6): 671\u2013680. doi: 10.1016\/j.ejvs.2009.02.017","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"511_CR2","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.ejvs.2009.10.019","volume":"39","author":"WMPF Bosman","year":"2010","unstructured":"Bosman WMPF, van der Steenhoven TJ, Su\u00e1rez DR, Hinnen JW, Valstar ER, Hamming JF (2010) The proximal fixation strength of modern EVAR grafts in a short aneurysm neck\u2014an in vitro study. Eur J Vasc Endovasc Surg 39: 187\u2013192. doi: 10.1016\/j.ejvs.2009.10.019 Elsevier Ltd","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"511_CR3","unstructured":"Gebert de Uhlenbrock A (2009) Designanalyse von endovaskul\u00e4ren Aortenprothesen. Dissertation, Technische Universit\u00e4t Hamburg-Harburg, urn:nbn:de:gbv:830-tubdok-7993"},{"issue":"1","key":"511_CR4","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1053\/ejvs.1998.0711","volume":"17","author":"AW Lambert","year":"1999","unstructured":"Lambert AW, Williams DJ, Budd JS, Horrocks M (1999) Experimental assessment of proximal stent-graft (interVascular) fixation in human cadaveric infrarenal aortas. Eur J Vasc Endovasc Surg 17(1): 60\u201365","journal-title":"Eur J Vasc Endovasc Surg"},{"issue":"4","key":"511_CR5","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1583\/1074-6218(1998)005<0310:EAEWSW>2.0.CO;2","volume":"5","author":"M Malina","year":"1998","unstructured":"Malina M, Lindblad B, Ivancev K, Lindh M, Malina J, Brunkwall J (1998) Endovascular AAA exclusion: will stents with hooks and barbs prevent stent-graft migration?. J Endovasc Surg 5(4): 310\u2013317","journal-title":"J Endovasc Surg"},{"issue":"4","key":"511_CR6","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1016\/S1078-5884(05)80007-3","volume":"9","author":"SM Andrews","year":"1995","unstructured":"Andrews SM, Anson AW, Greenhalgh RM, Nott DM (1995) In vitro evaluation of endovascular stents to assess suitability for endovascular graft fixation. Eur J Vasc Endovasc Surg 9(4): 403\u2013407","journal-title":"Eur J Vasc Endovasc Surg"},{"issue":"6","key":"511_CR7","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1016\/j.ejvs.2009.03.001","volume":"37","author":"E Waasdorp","year":"2009","unstructured":"Waasdorp E, de Vries J, Sterkenburg A, Vos J, Kelder H, Moll F, Zarins C (2009) The association between iliac fixation and proximal stent-graft migration during EVAR follow-up: mid-term results of 154 talent devices. Eur J Vasc Endovasc Surg 37(6): 681\u2013687. doi: 10.1016\/j.ejvs.2009.03.001","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"511_CR8","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1583\/1545-1550(2007)14[585:DRTIVD]2.0.CO;2","volume":"14","author":"EH Murphy","year":"2007","unstructured":"Murphy EH, Johnson ED, Arko FR (2007) Device-specific resistance to in vivo displacement of stent-grafts implanted with maximum iliac fixation. J Endovasc Ther 14: 585\u2013592","journal-title":"J Endovasc Ther"},{"key":"511_CR9","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1583\/1545-1550(2001)008<0358:AMANSO>2.0.CO;2","volume":"8","author":"K Liffman","year":"2001","unstructured":"Liffman K, Lawrence-Brown MM, Semmens JB, Bui A, Rudman M, Hartley DE (2001) Analytical modeling and numerical simulation of forces in an endoluminal graft. J Endovasc Ther 8: 358\u2013371","journal-title":"J Endovasc Ther"},{"key":"511_CR10","doi-asserted-by":"crossref","first-page":"1087","DOI":"10.1016\/j.jbiomech.2003.11.014","volume":"37","author":"L Morris","year":"2004","unstructured":"Morris L, Delassus P, Walsh M, McGloughlin T (2004) A mathematical model to predict the in vivo pulsatile drag forces acting on bifurcated stent grafts used in endovascular treatment of abdominal aortic aneurysms (AAA). J Biomech 37: 1087\u20131095","journal-title":"J Biomech"},{"issue":"4","key":"511_CR11","first-page":"211","volume":"4","author":"RA Sina","year":"2007","unstructured":"Sina RA, Westt K, Rontala RS, Greenberg RK, Banerjee RK (2007) In vitro measurement and calculation of drag force on iliac limb stentgraft in a compliant arterial wall model. Mol Cell Biomech (MCB), Tech Science Press 4(4): 211\u2013226","journal-title":"Mol Cell Biomech (MCB), Tech Science Press"},{"key":"511_CR12","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1007\/s002460010203","volume":"22","author":"M Okubo","year":"2001","unstructured":"Okubo M, Ino T, Takahashi K, Kishiro M, Akimoto K, Yamashiro Y (2001) Age dependency of stiffness of the abdominal aorta and the mechanical properties of the aorta in Kawasaki disease in children. Pediatr Cardiol 22: 198\u2013203. doi: 10.1007\/s002460010203 Springer","journal-title":"Pediatr Cardiol"},{"key":"511_CR13","doi-asserted-by":"crossref","unstructured":"Gao F, Watanabe M, Matsuzawa T (2006) Stress analysis in a layered aortic arch model under pulsatile blood flow. BioMed Eng Online 5. doi: 10.1186\/1475-925X-5-25","DOI":"10.1186\/1475-925X-5-25"},{"key":"511_CR14","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1186\/1475-925X-6-38","volume":"6","author":"B Doyle","year":"2007","unstructured":"Doyle B, Callanan A, McGloughlin T (2007) A comparison of modeling techniques for computing wall stress in abdominal aortic aneurysms. BioMed Eng Online 6: 38. doi: 10.1186\/1475-925X-6-38","journal-title":"BioMed Eng Online"},{"key":"511_CR15","unstructured":"Holzapfel GA (2002) Biomechanics of soft tissues with application to arterial walls. In: Mathematical and computational modelling of biological systems, chap 1. Centro Internacional de Matem\u00e1tica CIM, Coimbra, pp 1\u201337"},{"key":"511_CR16","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1115\/1.1800557","volume":"126","author":"GA Holzapfel","year":"2004","unstructured":"Holzapfel GA, Sommer G, Regitnig P (2004) Anisotropic mechanical properties of tissue components in human atherosclerotic plaques. J Biomech Eng H 126: 657\u2013665. doi: 10.1115\/1.1800557","journal-title":"J Biomech Eng H"},{"key":"511_CR17","unstructured":"Stary HC (2003) Atlas of atherosclerosis progression and regression, 2nd edn (Encyclopedia of Visual Medicine). Informa Healthcare, ISBN-10:1842141538"},{"key":"511_CR18","doi-asserted-by":"crossref","unstructured":"Holzapfel GA (2009) Arterial tissue in health and disease: experimental data, collagen-based modelling and simulation, including aortic dissection. In: Biomechanical modelling at the molecular, cellular and tissue levels, CISM Courses and Lectures No. 508. Springer, Vienna, pp 259\u2013343","DOI":"10.1007\/978-3-211-95875-9_4"},{"key":"511_CR19","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1080\/10255840108908007","volume":"4","author":"F Auricchio","year":"2001","unstructured":"Auricchio F, Loreto M, Sacco E (2001) Finite-element analysis of a stenotic artery revascularization through a stent insertion. Comput Methods Biomech Biomed Eng 4: 249\u2013263. doi: 10.1080\/10255840108908007","journal-title":"Comput Methods Biomech Biomed Eng"},{"issue":"4","key":"511_CR20","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1007\/s10237-004-0039-6","volume":"2","author":"F Migliavacca","year":"2004","unstructured":"Migliavacca F, Petrini L, Massarotti Paolo, Schievano S, Auricchio F, Dubini G (2004) Stainless and shape memory alloy coronary stents: a computational study on the interaction with the vascular wall. Biomech Model Mechanobiol 2(4): 205\u2013217. doi: 10.1007\/s10237-004-0039-6","journal-title":"Biomech Model Mechanobiol"},{"issue":"3","key":"511_CR21","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1016\/j.ijcard.2004.12.033","volume":"104","author":"DK Liang","year":"2005","unstructured":"Liang DK, Yang DZ, Qi M, Wang WQ (2005) Finite element analysis of the implantation of a balloon-expandable stent in a stenosed artery. Int J Cardiol 104(3): 314\u2013318. doi: 10.1016\/j.ijcard.2004.12.033","journal-title":"Int J Cardiol"},{"issue":"11","key":"511_CR22","doi-asserted-by":"crossref","first-page":"2580","DOI":"10.1016\/j.jbiomech.2006.11.009","volume":"40","author":"W Wu","year":"2007","unstructured":"Wu W, Wang WQ, Yang DZ, Qi M (2007) Stent expansion in curved vessel and their interactions: a finite element analysis. J Biomech 40(11): 2580\u20132585. doi: 10.1016\/j.jbiomech.2006.11.009","journal-title":"J Biomech"},{"key":"511_CR23","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1016\/j.medengphy.2008.11.005","volume":"31","author":"I Pericevic","year":"2009","unstructured":"Pericevic I, Lally C, Toner D, Kelly D (2009) The influence of plaque composition on underlying arterial wall stress during stent expansion: the case for lesion-specific stents. Med Eng Phys 31: 428\u2013433","journal-title":"Med Eng Phys"},{"issue":"1","key":"511_CR24","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1080\/10255840802136135","volume":"12","author":"M Early","year":"2009","unstructured":"Early M, Lally C, Prendergast PJ, Kelly DJ (2009) Comput Methods Biomech Biomed Eng 12(1): 25\u201333 First published 2009","journal-title":"Comput Methods Biomech Biomed Eng"},{"key":"511_CR25","unstructured":"Fuchs V (2008) Nichtlineare Finite Element Untersuchung mit der Finite Element Software ANSYS. Am Beispiel eines Nitinolstents und Humangewebe. Diploma thesis, Fachhochschule Frankfurt am Main, Diplomica Verlag GmbH, ISBN: 978-3-8366-1835-9"},{"key":"511_CR26","unstructured":"National Electrical Manufacturers Association (2008) Digital imaging and communications in medicine (DICOM) NEMA, Rosslyn. http:\/\/medical.nema.org . Accessed 10 Jan 2010"},{"key":"511_CR27","unstructured":"National Electrical Manufacturers Association (2008) Digital imaging and communications in medicine (DICOM), Supplement 131: Implant Templates. NEMA, Rosslyn. http:\/\/medical.nema.org . Accessed 10 Jan 2010"},{"key":"511_CR28","unstructured":"National Electrical Manufacturers Association (2008) Digital imaging and communications in medicine (DICOM), Supplement 132: Surface Segmentation. NEMA, Rosslyn. http:\/\/medical.nema.org . Accessed 10 Jan 2010"},{"key":"511_CR29","unstructured":"National Electrical Manufacturers Association (2008) Digital imaging and communications in medicine (DICOM), Supplement 134: Implantation Plan SR Document, NEMA, Rosslyn. http:\/\/medical.nema.org . Accessed 10 Jan 2010"},{"key":"511_CR30","unstructured":"Migliavacca F, Petrini L, Auricchio F, Dubini G (2003) Deployment of an intravscular stent in coronary stenotic arteries: a computational study. In: Proccedings: summer bioengineering conference June 25\u201329, Florida"},{"issue":"1","key":"511_CR31","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1016\/j.jbiomech.2004.11.003","volume":"39","author":"WQ Wang","year":"2006","unstructured":"Wang WQ, Liang DK, Yang DZ, Qi M (2006) Analysis of the transient expansion behavior and design optimization of coronary stents by finite element method. J Biomech 39(1): 21\u201332. doi: 10.1016\/j.jbiomech.2004.11.003","journal-title":"J Biomech"},{"issue":"3","key":"511_CR32","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1016\/j.medengphy.2006.04.003","volume":"29","author":"K Takashima","year":"2007","unstructured":"Takashima K, Kitou T, Mori K, Ikeuchi K (2007) Simulation and experimental observation of contact conditions between stents and artery models. Med Eng Phys 29(3): 326\u2013335. doi: 10.1016\/j.medengphy.2006.04.003","journal-title":"Med Eng Phys"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-010-0511-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-010-0511-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-010-0511-y","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,1]],"date-time":"2019-06-01T16:35:52Z","timestamp":1559406952000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-010-0511-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,7,22]]},"references-count":32,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2011,5]]}},"alternative-id":["511"],"URL":"https:\/\/doi.org\/10.1007\/s11548-010-0511-y","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,7,22]]}}}