{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T10:09:51Z","timestamp":1790676591049,"version":"4.1.0"},"reference-count":58,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2010,9,2]],"date-time":"2010-09-02T00:00:00Z","timestamp":1283385600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2011,7]]},"DOI":"10.1007\/s11548-010-0528-2","type":"journal-article","created":{"date-parts":[[2010,9,1]],"date-time":"2010-09-01T04:10:04Z","timestamp":1283314204000},"page":"473-488","source":"Crossref","is-referenced-by-count":30,"title":["Mutual interferences and design principles for mechatronic devices in magnetic resonance imaging"],"prefix":"10.1007","volume":"6","author":[{"given":"Ningbo","family":"Yu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roger","family":"Gassert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Riener","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2010,9,2]]},"reference":[{"issue":"3","key":"528_CR1","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1109\/EMB.2007.910265","volume":"27","author":"R Gassert","year":"2008","unstructured":"Gassert R, Burdet E, Chinzei K (2008) Opportunities and challenges in MR-compatible robotics. IEEE Eng Med Biol Mag 27(3): 15\u201322","journal-title":"IEEE Eng Med Biol Mag"},{"key":"528_CR2","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1146\/annurev.bioeng.9.121806.160642","volume":"9","author":"NV Tsekos","year":"2007","unstructured":"Tsekos NV, Khanicheh A, Christoforou E, Mavroidis C (2007) Magnetic resonance-compatible robotic and mechatronics systems for image-guided interventions and rehabilitation: a review study. Annu Rev Biomed Eng 9: 351\u2013387","journal-title":"Annu Rev Biomed Eng"},{"key":"528_CR3","unstructured":"Yu N, Riener R (2006) Review on MR-compatible robotic systems. In: The IEEE\/RAS-EMBS international conference on biomedical robotics and biomechatronics (BioRob), Pisa, Italy"},{"key":"528_CR4","doi-asserted-by":"crossref","unstructured":"Chinzei K, Kikinis R, Jolesz FA (1999) MR compatibility of mechatronic devices: design criteria. In: The international conference on medical image computing and computer-assisted intervention","DOI":"10.1007\/10704282_111"},{"issue":"6","key":"528_CR5","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1118\/1.597854","volume":"23","author":"JF Schenck","year":"1996","unstructured":"Schenck JF (1996) The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. Med Phys 23(6): 815\u2013850","journal-title":"Med Phys"},{"issue":"4","key":"528_CR6","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1002\/cmr.b.20070","volume":"29","author":"R Gassert","year":"2006","unstructured":"Gassert R, Yamamoto A, Chapuis D, Dovat L, Bleuler H, Burdet E (2006) Actuation methods for applications in MR environments. Concepts Magn Reson B Magn Reson Eng 29(4): 191\u2013209","journal-title":"Concepts Magn Reson B Magn Reson Eng"},{"issue":"3","key":"528_CR7","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1109\/TMECH.2008.924113","volume":"13","author":"R Gassert","year":"2008","unstructured":"Gassert R, Chapuis D, Bleuler H, Burdet E (2008) Sensors for applications in magnetic resonance environments. IEEE\/ASME Trans Mechatron 13(3): 335\u2013344","journal-title":"IEEE\/ASME Trans Mechatron"},{"key":"528_CR8","unstructured":"A primer on medical device interactions with magnetic resonance imaging systems. The US Food and Drug Administration (FDA) (1997)"},{"key":"528_CR9","unstructured":"MR safety and MR compatibility: test guidelines for signa SPTM, Version 1.0. GE Medical Systems (1997)"},{"key":"528_CR10","unstructured":"Standard test method for measurement of magnetically induced displacement force on medical devices in the magnetic resonance environment. ASTM F2052-06e1, 2006"},{"key":"528_CR11","unstructured":"Standard test method for measurement of magnetically induced torque on passive implants in the magnetic resonance environment. ASTM F2213-06, 2006"},{"key":"528_CR12","unstructured":"Standard test method for evaluation of MR image artifacts from passive implants. ASTM F2119-07, 2007"},{"issue":"3","key":"528_CR13","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1109\/EMB.2007.910267","volume":"27","author":"G Schaefers","year":"2008","unstructured":"Schaefers G (2008) Testing MR safety and compatibility. IEEE Eng Med Biol Mag 27(3): 23\u201327","journal-title":"IEEE Eng Med Biol Mag"},{"key":"528_CR14","unstructured":"Guidance for industry and FDA staff\u2014establishing safety and compatibility of passive implants in the magnetic resonance (MR) environment. The US Food and Drug Administration (FDA) (2008)"},{"key":"528_CR15","unstructured":"Standard test method for evaluation of MR image artifacts from passive implants. ASTM F 2119-01, 2001"},{"issue":"3","key":"528_CR16","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1109\/EMB.2007.910273","volume":"27","author":"R Gassert","year":"2008","unstructured":"Gassert R, Burdet E, Chinzei K (2008) MRI-compatible robotics. IEEE Eng Med Biol Mag 27(3): 12\u201314","journal-title":"IEEE Eng Med Biol Mag"},{"key":"528_CR17","unstructured":"Technical description: Intera 1.5T Release 2.5 series, Achieva 1.5T \/ 3.0T \/ XR Release 2.5, Panorama HFO Release 2.5 series. Philips Medical Systems Nederland (2007)"},{"key":"528_CR18","unstructured":"Wilde JD, Price D, Williams J, Delakis I, Renaud C (2004) Comparative specications of four 3T MRI systems. Medicines and Healthcare products Regulatory Agency, Department of Health, UK, techniacl report"},{"issue":"2","key":"528_CR19","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1002\/mrm.1910390218","volume":"39","author":"MA Bernstein","year":"1998","unstructured":"Bernstein MA, Zhou XJ, Polzin JA, King KF, Ganin A, Pelc NJ, Glover GH (1998) Concomitant gradient terms in phase contrast MR: analysis and correction. Magn Reson Med 39(2): 300\u2013318","journal-title":"Magn Reson Med"},{"key":"528_CR20","doi-asserted-by":"crossref","unstructured":"Riener R, Villgrattner T, Kleiser R, Nef T, Kollias S (2005) fMRI-compatible electromagnetic haptic interface. In: The IEEE-EMBS annual international conference of the engineering in medicine and biology society (EMBS), vol 7, pp 7024\u20137027","DOI":"10.1109\/IEMBS.2005.1616123"},{"key":"528_CR21","unstructured":"Chapuis D (2009) Application of ultrasonic motors to MR-compatible haptic interfaces. PhD Thesis"},{"issue":"4","key":"528_CR22","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1002\/jmri.20539","volume":"23","author":"H Graf","year":"2006","unstructured":"Graf H, Lauer UA, Schick F (2006) Eddy-current induction in extended metallic parts as a source of considerable torsional moment. J Magn Reson Imaging 23(4): 585\u2013590","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"528_CR23","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1002\/jmri.1880050115","volume":"5","author":"CR Camacho","year":"1995","unstructured":"Camacho CR, Plewes DB, Henkelman RM (1995) Nonsusceptibility artifacts due to metallic objects in MR imaging. J Magn Reson Imaging 5(1): 75\u201388","journal-title":"J Magn Reson Imaging"},{"key":"528_CR24","unstructured":"Standard test method for measurement of radio frequency induced heating near passive implants during magnetic resonance imaging. ASTM F2182-02a, 2002"},{"issue":"1","key":"528_CR25","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1002\/1522-2586(200007)12:1<79::AID-JMRI9>3.0.CO;2-T","volume":"12","author":"MK Konings","year":"2000","unstructured":"Konings MK, Bartels LW, Smits HF, Bakker CJ (2000) Heating around intravascular guidewires by resonating RF waves. J Magn Reson Imaging 12(1): 79\u201385","journal-title":"J Magn Reson Imaging"},{"issue":"2","key":"528_CR26","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1053\/euhj.2000.2149","volume":"22","author":"F Duru","year":"2001","unstructured":"Duru F, Luechinger R, Scheidegger MB, Luscher TF, Boesiger P, Candinas R (2001) Pacing in magnetic resonance imaging environment: clinical and technical considerations on compatibility. Eur Heart J 22(2): 113\u2013124","journal-title":"Eur Heart J"},{"key":"528_CR27","unstructured":"Lchinger RC (2002) Safety aspects of cardiac pacemakers in magnetic resonance imaging. PhD thesis"},{"issue":"5","key":"528_CR28","doi-asserted-by":"crossref","first-page":"1328","DOI":"10.1002\/jmri.21157","volume":"26","author":"H Graf","year":"2007","unstructured":"Graf H, Steidle G, Schick F (2007) Heating of metallic implants and instruments induced by gradient switching in a 1.5-Tesla whole-body unit. J Magn Reson Imaging 26(5): 1328\u20131333","journal-title":"J Magn Reson Imaging"},{"issue":"4","key":"528_CR29","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1002\/jmri.1088","volume":"13","author":"MF Dempsey","year":"2001","unstructured":"Dempsey MF, Condon B, Hadley DM (2001) Investigation of the factors responsible for burns during MRI. J Magn Reson Imaging 13(4): 627\u2013631","journal-title":"J Magn Reson Imaging"},{"issue":"3","key":"528_CR30","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1002\/mrm.1910070302","volume":"7","author":"R Buchli","year":"1988","unstructured":"Buchli R, Boesiger P, Meier D (1988) Heating effects of metallic implants by MRI examinations. Magn Reson Med 7(3): 255\u2013261","journal-title":"Magn Reson Med"},{"issue":"6","key":"528_CR31","doi-asserted-by":"crossref","first-page":"1338","DOI":"10.1002\/jmri.1880080625","volume":"8","author":"FG Shellock","year":"1998","unstructured":"Shellock FG, Shellock VJ (1998) Cardiovascular catheters and accessories: ex vivo testing of ferromagnetism, heating, and artifacts associated with MRI. J Magn Reson Imaging 8(6): 1338\u20131342","journal-title":"J Magn Reson Imaging"},{"issue":"2\u20133","key":"528_CR32","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1002\/(SICI)1097-0193(1999)8:2\/3<80::AID-HBM2>3.0.CO;2-C","volume":"8","author":"P Jezzard","year":"1999","unstructured":"Jezzard P, Clare S (1999) Sources of distortion in functional MRI data. Hum Brain Mapp 8(2\u20133): 80\u201385","journal-title":"Hum Brain Mapp"},{"key":"528_CR33","doi-asserted-by":"crossref","DOI":"10.1017\/CBO9780511545405","volume-title":"MRI from picture to proton","author":"DW McRobbie","year":"2006","unstructured":"McRobbie DW (2006) MRI from picture to proton, 2nd edn. Cambridge University Press, Cambridge","edition":"2"},{"issue":"3","key":"528_CR34","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1002\/1522-2594(200103)45:3<470::AID-MRM1062>3.0.CO;2-E","volume":"45","author":"YZ Wadghiri","year":"2001","unstructured":"Wadghiri YZ, Johnson G, Turnbull DH (2001) Sensitivity and performance time in MRI dephasing artifact reduction methods. Magn Reson Med 45(3): 470\u2013476","journal-title":"Magn Reson Med"},{"issue":"6","key":"528_CR35","doi-asserted-by":"crossref","first-page":"1443","DOI":"10.1002\/jmri.21164","volume":"27","author":"KM Franklin","year":"2008","unstructured":"Franklin KM, Dale BM, Merkle EM (2008) Improvement in B1-inhomogeneity artifacts in the abdomen at 3T MR imaging using a radiofrequency cushion. J Magn Reson Imaging 27(6): 1443\u20131447","journal-title":"J Magn Reson Imaging"},{"key":"528_CR36","doi-asserted-by":"crossref","unstructured":"Chinzei K, Yoshinaka K, Washio T (2006) Numerical simulations and lab tests for design of MR-compatible robots. In: The IEEE international conference on robotics and automation (ICRA), Orlando, FL, USA, pp 3819\u20133824","DOI":"10.1109\/ROBOT.2006.1642286"},{"issue":"3","key":"528_CR37","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1016\/j.neuroimage.2005.04.039","volume":"27","author":"J Diedrichsen","year":"2005","unstructured":"Diedrichsen J, Shadmehr R (2005) Detecting and adjusting for artifacts in fMRI time series data. Neuroimage 27(3): 624\u2013634","journal-title":"Neuroimage"},{"key":"528_CR38","doi-asserted-by":"crossref","unstructured":"Yu N, Murr W, Blickenstorfer A, Kollias S, Riener R (2007) An fMRI compatible haptic interface with pneumatic actuation. In: The IEEE international conference on rehabilitation robotics (ICORR), Nordwijk, The Netherlands","DOI":"10.1109\/ICORR.2007.4428504"},{"issue":"1","key":"528_CR39","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1109\/TMECH.2006.886258","volume":"12","author":"D Stoianovici","year":"2007","unstructured":"Stoianovici D, Patriciu A, Petrisor D, Mazilu D, Kavoussi L (2007) A new type of motor: pneumatic step motor. IEEE\/ASME Trans Mechatron 12(1): 98\u2013106","journal-title":"IEEE\/ASME Trans Mechatron"},{"issue":"2","key":"528_CR40","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1109\/TMECH.2006.871897","volume":"11","author":"R Gassert","year":"2006","unstructured":"Gassert R, Moser R, Burdet E, Bleuler H (2006) MRI\/fMRI- compatible robotic system with force feedback for interaction with human motion. IEEE\/ASME Trans Mechatron 11(2): 216\u2013224","journal-title":"IEEE\/ASME Trans Mechatron"},{"issue":"3","key":"528_CR41","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1109\/TMECH.2008.924041","volume":"13","author":"N Yu","year":"2008","unstructured":"Yu N, Hollnagel C, Blickenstorfer A, Kollias SS, Riener R (2008) Comparison of MRI-compatible mechatronic systems with hydrodynamic and pneumatic actuation. IEEE\/ASME Trans Mechatron 13(3): 268\u2013277","journal-title":"IEEE\/ASME Trans Mechatron"},{"key":"528_CR42","doi-asserted-by":"crossref","unstructured":"Chapuis D, Gassert R, Ganesh G, Burdet EABE, Bleuler HABH (2006) Investigation of a cable transmission for the actuation of MR compatible haptic interfaces. In: Gassert R (ed) The IEEE\/RAS-EMBS international conference on biomedical robotics and biomechatronics (BioRob), pp 426\u2013431","DOI":"10.1109\/BIOROB.2006.1639125"},{"key":"528_CR43","doi-asserted-by":"crossref","unstructured":"Chinzei K, Hata N, Jolesz FA, Kikinis RAKR (2000) Surgical assist robot for the active navigation in the intraoperative mri: hardware design issues. In: Hata N (ed) The IEEE\/RSJ international conference on intelligent robots and systems (IROS), vol 1, pp 727\u2013732","DOI":"10.1109\/IROS.2000.894690"},{"issue":"4","key":"528_CR44","doi-asserted-by":"crossref","first-page":"458","DOI":"10.1115\/1.1785803","volume":"126","author":"BT Larson","year":"2004","unstructured":"Larson BT, Erdman AG, Tsekos NV, Yacoub E, Tsekos PV, Koutlas IG (2004) Design of an MRI-compatible robotic stereotactic device for minimally invasive interventions in the breast. J Biomech Eng 126(4): 458\u2013465","journal-title":"J Biomech Eng"},{"issue":"1","key":"528_CR45","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1109\/TNSRE.2007.910286","volume":"16","author":"A Khanicheh","year":"2008","unstructured":"Khanicheh A, Mintzopoulos D, Weinberg B, Tzika AA, Mavroidis C (2008) MR-CHIROD v.2: magnetic resonance compatible smart hand rehabilitation device for brain imaging. IEEE Trans Neural Syst Rehabil Eng 16(1): 91\u201398","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"2","key":"528_CR46","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1016\/j.jneumeth.2006.01.016","volume":"155","author":"J Hidler","year":"2006","unstructured":"Hidler J, Hodics T, Xu B, Dobkin B, Cohen LG (2006) MR compatible force sensing system for real-time monitoring of wrist moments during fMRI testing. J Neurosci Methods 155(2): 300\u2013307","journal-title":"J Neurosci Methods"},{"key":"528_CR47","unstructured":"Gassert R (2006) MR-compatible robotics to investigate human motor control. PhD thesis"},{"issue":"6","key":"528_CR48","doi-asserted-by":"crossref","first-page":"1439","DOI":"10.1002\/mrm.20713","volume":"54","author":"P Kellman","year":"2005","unstructured":"Kellman P, McVeigh ER (2005) Image reconstruction in SNR units: a general method for SNR measurement. Magn Reson Med 54(6): 1439\u20131447","journal-title":"Magn Reson Med"},{"issue":"2","key":"528_CR49","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1002\/rcs.19","volume":"1","author":"D Stoianovici","year":"2005","unstructured":"Stoianovici D (2005) Multi-imager compatible actuation principles in surgical robotics. Int J Med Robot Comput Assist Surg MRCAS 1(2): 86\u2013100","journal-title":"Int J Med Robot Comput Assist Surg MRCAS"},{"key":"528_CR50","unstructured":"Chapuis D, Gassert R, Hartwig V, Vanello N, Bicchi A (2004) Prototype fMRI compatible actuators. Technical report, 30 May 2004"},{"issue":"3","key":"528_CR51","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1109\/TMECH.2008.924115","volume":"13","author":"N Vanello","year":"2008","unstructured":"Vanello N, Hartwig V, Tesconi M, Ricciardi E, Tognetti A, Zupone G, Gassert R, Chapuis D, Sgambelluri N, Scilingo EP, Giovannetti G, Positano V, Santarelli MF, Bicchi A, Pietrini P, Rossi DD, Landini L (2008) Sensing glove for brain studies: design and assessment of its compatibility for fMRI with a robust test. IEEE\/ASME Trans Mechatron 13(3): 345\u2013354","journal-title":"IEEE\/ASME Trans Mechatron"},{"key":"528_CR52","unstructured":"Mathworks MATLAB user\u2019s guide, 2008"},{"issue":"1","key":"528_CR53","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1006\/nimg.2001.1054","volume":"16","author":"C Hutton","year":"2002","unstructured":"Hutton C, Bork A, Josephs O, Deichmann R, Ashburner J, Turner R (2002) Image distortion correction in fMRI: a quantitative evaluation. Neuroimage 16(1): 217\u2013240","journal-title":"Neuroimage"},{"key":"528_CR54","doi-asserted-by":"crossref","unstructured":"Funai A, Fessler JA, Grissom W, Noll DC (2007) Regularized B1+ map estimation in MRI. In: The IEEE international symposium on biomedical imaging: macro to nano, vol 1\u20133, pp 616\u2013619, 1383","DOI":"10.1109\/ISBI.2007.356927"},{"issue":"10","key":"528_CR55","doi-asserted-by":"crossref","first-page":"1484","DOI":"10.1109\/TMI.2008.923956","volume":"27","author":"AK Funai","year":"2008","unstructured":"Funai AK, Fessler JA, Yeo DTB, Olafsson VT, Noll DC (2008) Regularized field map estimation in MRI. IEEE Trans Med Imaging 27(10): 1484\u20131494","journal-title":"IEEE Trans Med Imaging"},{"issue":"1","key":"528_CR56","doi-asserted-by":"crossref","first-page":"266","DOI":"10.3390\/s100100266","volume":"10","author":"F Baselice","year":"2010","unstructured":"Baselice F, Ferraioli G, Shabou A (2010) Field map reconstruction in magnetic resonance imaging using bayesian estimation. Sensors 10(1): 266\u2013279","journal-title":"Sensors"},{"issue":"894","key":"528_CR57","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1259\/bjr.75.894.750523","volume":"75","author":"DW McRobbie","year":"2002","unstructured":"McRobbie DW, Quest RA (2002) Effectiveness and relevance of MR acceptance testing: results of an 8\u00a0year audit. Br J Radiol 75(894): 523\u2013531","journal-title":"Br J Radiol"},{"key":"528_CR58","unstructured":"Koivula A (2002) Magnetic resonance image distortions due to artificial macroscopic objects\u2014an example: correction of image distortion caused by an artificial hip prosthesis. PhD thesis"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-010-0528-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-010-0528-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-010-0528-2","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,2]],"date-time":"2019-06-02T20:35:25Z","timestamp":1559507725000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-010-0528-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,9,2]]},"references-count":58,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2011,7]]}},"alternative-id":["528"],"URL":"https:\/\/doi.org\/10.1007\/s11548-010-0528-2","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,9,2]]}}}