{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,14]],"date-time":"2026-03-14T23:39:17Z","timestamp":1773531557245,"version":"3.50.1"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2011,1,5]],"date-time":"2011-01-05T00:00:00Z","timestamp":1294185600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2011,9]]},"DOI":"10.1007\/s11548-010-0544-2","type":"journal-article","created":{"date-parts":[[2011,1,4]],"date-time":"2011-01-04T10:27:45Z","timestamp":1294136865000},"page":"635-640","source":"Crossref","is-referenced-by-count":14,"title":["Successive iterative restoration applied to streak artifact reduction in X-ray CT image of dento-alveolar region"],"prefix":"10.1007","volume":"6","author":[{"given":"Jian","family":"Dong","sequence":"first","affiliation":[]},{"given":"Atsushi","family":"Kondo","sequence":"additional","affiliation":[]},{"given":"Kosuke","family":"Abe","sequence":"additional","affiliation":[]},{"given":"Yoshihiko","family":"Hayakawa","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2011,1,5]]},"reference":[{"key":"544_CR1","doi-asserted-by":"crossref","first-page":"1285","DOI":"10.3174\/ajnr.A1654","volume":"30","author":"AC Miracle","year":"2009","unstructured":"Miracle AC, Mukherji SK (2009) Conebeam CT of the head and neck, part 2: clinical applications. Am J Neuroradiol 30: 1285\u20131292","journal-title":"Am J Neuroradiol"},{"key":"544_CR2","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1007\/s12149-009-0254-4","volume":"23","author":"H Shimamoto","year":"2009","unstructured":"Shimamoto H, Kakimoto N, Fujino K, Hamada S, Shimosegawa E, Murakami S, Furukawa S, Hatazawa J (2009) Metallic artifacts caused by dental metal prostheses on PET images: a PET\/CT phantom study using different PET\/CT scanners. Ann Nucl Med 23: 443\u2013449. doi: 10.1007\/s12149-009-0254-4","journal-title":"Ann Nucl Med"},{"key":"544_CR3","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1016\/j.compmedimag.2009.02.003","volume":"33","author":"K Imai","year":"2009","unstructured":"Imai K, Ikeda M, Enchi Y, Niimi T (2009) Quantitative assessment of image noise and streak artifact on CT image: comparison of z-axis automatic tube current modulation technique with fixed tube current technique. Comput Med Imaging Graph 33: 353\u2013358. doi: 10.1016\/j.compmedimag.2009.02.003","journal-title":"Comput Med Imaging Graph"},{"key":"544_CR4","doi-asserted-by":"crossref","first-page":"1047","DOI":"10.2967\/jnumed.107.049858","volume":"49","author":"C Nahmias","year":"2008","unstructured":"Nahmias C, Lemmens C, Faul D, Carlson E, Long M, Blodgett T, Nuyts J, Townsend D (2008) Does reducing CT artifacts from dental implants influence the PET interpretation in PET\/CT studies of oral cancer and head and neck cancer?. J Nucl Med 49: 1047\u20131052. doi: 10.2967\/jnumed.107.049858","journal-title":"J Nucl Med"},{"key":"544_CR5","doi-asserted-by":"crossref","first-page":"911","DOI":"10.1259\/bjr\/93741044","volume":"80","author":"K Imai","year":"2007","unstructured":"Imai K, Ikeda M, Wada S, Enchi Y, Niimi T (2007) Analysis of streak artefacts on CT images using statistics of extremes. Br J Radiol 80: 911\u2013918","journal-title":"Br J Radiol"},{"key":"544_CR6","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1118\/1.3276777","volume":"37","author":"WJ Veldkamp","year":"2010","unstructured":"Veldkamp WJ, Joemai RM, van der Molen AJ, Geleijns J (2010) Development and validation of segmentation and interpolation techniques in sinograms for metal artifact suppression in CT. Med Phys 37: 620\u2013628","journal-title":"Med Phys"},{"key":"544_CR7","doi-asserted-by":"crossref","first-page":"6575","DOI":"10.1088\/0031-9155\/54\/21\/009","volume":"54","author":"D Prell","year":"2009","unstructured":"Prell D, Kyriakou Y, Beister M, Kalender WA (2009) A novel forward projection-based metal artifact reduction method for flat-detector computed tomography. Phys Med Biol 54: 6575\u20136591","journal-title":"Phys Med Biol"},{"key":"544_CR8","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1097\/RCT.0b013e318149e215","volume":"32","author":"J Rinkel","year":"2008","unstructured":"Rinkel J, Dillon WP, Funk T, Gould R, Prevrhal S (2008) Computed tomographic metal artifact reduction for the detection and quantitation of small features near large metallic implants: a comparison of published methods. J Comput Assist Tomogr 32: 621\u2013629. doi: 10.1097\/RCT.0b013e318149e215","journal-title":"J Comput Assist Tomogr"},{"key":"544_CR9","doi-asserted-by":"crossref","first-page":"630","DOI":"10.1097\/RCT.0b013e3181568b27","volume":"32","author":"SG Moon","year":"2008","unstructured":"Moon SG, Hong SH, Choi JY, Jun WS, Kang HG, Kim HS, Kang HS (2008) Metal artifact reduction by the alteration of technical factors in multidetector computed tomography: a 3-dimensional quantitative assessment. J Comput Assist Tomogr 32: 630\u2013633. doi: 10.1097\/RCT.0b013e3181568b27","journal-title":"J Comput Assist Tomogr"},{"key":"544_CR10","doi-asserted-by":"crossref","first-page":"924","DOI":"10.1016\/j.ijrobp.2006.09.045","volume":"67","author":"Y Zhang","year":"2007","unstructured":"Zhang Y, Zhang L, Zhu XR, Lee AK, Chambers M, Dong L (2007) Reducing metal artifacts in cone-beam CT images by preprocessing projection data. Int J Radiat Oncol Biol Phys 67: 924\u2013932. doi: 10.1016\/j.ijrobp.2006.09.045","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"544_CR11","doi-asserted-by":"crossref","first-page":"2852","DOI":"10.1118\/1.2218062","volume":"33","author":"M Bal","year":"2006","unstructured":"Bal M, Spies L (2006) Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering. Med Phys 33: 2852\u20132859","journal-title":"Med Phys"},{"key":"544_CR12","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1088\/0031-9155\/51\/2\/004","volume":"51","author":"D Hwang","year":"2006","unstructured":"Hwang D, Zeng GL (2006) Convergence study of an accelerated ML-EM algorithm using bigger step size. Phys Med Biol 51: 237\u2013252","journal-title":"Phys Med Biol"},{"key":"544_CR13","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1016\/S1076-6332(00)80576-0","volume":"7","author":"G Wang","year":"2000","unstructured":"Wang G, Frei T, Vannier MW (2000) Fast iterative algorithm for metal artifact reduction in X-ray CT. Acad Radiol 7: 607\u2013614","journal-title":"Acad Radiol"},{"key":"544_CR14","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1007\/BF02347809","volume":"8","author":"Y Morita","year":"1992","unstructured":"Morita Y (1992) A new computed tomography using imaging-plate and incomplete projection data. Oral Radiol 8: 119\u2013126. doi: 10.1007\/BF02347809","journal-title":"Oral Radiol"},{"issue":"26","key":"544_CR15","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1038\/sj.dmfr.4600201","volume":"1997","author":"RL Webber","year":"1997","unstructured":"Webber RL, Horton RA, Tyndall DA, Ludlow JB (1997) Tuned-aperture computed tomography (TACT). Theory and application for three-dimensional dento-alveolar imaging. Dentomaxillofac Radiol 1997(26): 53\u201362","journal-title":"Dentomaxillofac Radiol"},{"key":"544_CR16","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1007\/s11282-010-0037-6","volume":"26","author":"A Kondo","year":"2010","unstructured":"Kondo A, Hayakawa Y, Dong J, Honda A (2010) Iterative correction applied to streak artifact reduction in an X-ray computed tomography image of the dento-alveolar region. Oral Radiol 26: 61\u201365. doi: 10.1007\/s11282-010-0037-6","journal-title":"Oral Radiol"},{"key":"544_CR17","first-page":"243","volume":"27","author":"EA Rashed","year":"2009","unstructured":"Rashed EA, Kudo H (2009) Intensity-based Bayesian framework for image reconstruction from sparse projection data. Med Imaging Technol Jpn 27: 243\u2013251","journal-title":"Med Imaging Technol Jpn"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-010-0544-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-010-0544-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-010-0544-2","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,1]],"date-time":"2019-06-01T12:35:52Z","timestamp":1559392552000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-010-0544-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,1,5]]},"references-count":17,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2011,9]]}},"alternative-id":["544"],"URL":"https:\/\/doi.org\/10.1007\/s11548-010-0544-2","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,1,5]]}}}