{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T12:13:04Z","timestamp":1774959184365,"version":"3.50.1"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2011,6,23]],"date-time":"2011-06-23T00:00:00Z","timestamp":1308787200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2012,3]]},"DOI":"10.1007\/s11548-011-0598-9","type":"journal-article","created":{"date-parts":[[2011,6,22]],"date-time":"2011-06-22T06:30:47Z","timestamp":1308724247000},"page":"181-190","source":"Crossref","is-referenced-by-count":44,"title":["Robotic system for MRI-guided prostate biopsy: feasibility of teleoperated needle insertion and ex vivo phantom study"],"prefix":"10.1007","volume":"7","author":[{"given":"Reza","family":"Seifabadi","sequence":"first","affiliation":[]},{"given":"Sang-Eun","family":"Song","sequence":"additional","affiliation":[]},{"given":"Axel","family":"Krieger","sequence":"additional","affiliation":[]},{"given":"Nathan Bongjoon","family":"Cho","sequence":"additional","affiliation":[]},{"given":"Junichi","family":"Tokuda","sequence":"additional","affiliation":[]},{"given":"Gabor","family":"Fichtinger","sequence":"additional","affiliation":[]},{"given":"Iulian","family":"Iordachita","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2011,6,23]]},"reference":[{"key":"598_CR1","unstructured":"American Cancer Society (2010) Cancer facts and figures 2010. American Cancer Society, Atlanta"},{"key":"598_CR2","doi-asserted-by":"crossref","unstructured":"Jemal A, Siegel R, Ward E, Hao Y, Xu J, Thun MJ (2009) Cancer Statistics, 2009. CA: A Cancer Journal for Clinicians, page caac.20006","DOI":"10.3322\/caac.20006"},{"key":"598_CR3","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1159\/000283071","volume":"59","author":"MK Terris","year":"1997","unstructured":"Terris MK, Wallen EM, Stamey TA (1997) Comparison of mid-lobe versus lateral systematic sextant biopsies in detection of prostate cancer. Urol Int 59: 239\u2013242","journal-title":"Urol Int"},{"issue":"1","key":"598_CR4","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/S0033-8389(05)70150-0","volume":"38","author":"KK Yu","year":"2000","unstructured":"Yu KK, Hricak H (2000) Imaging prostate cancer. Radiol Clin North Am 38(1): 59\u201385","journal-title":"Radiol Clin North Am"},{"issue":"4","key":"598_CR5","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1002\/pros.20298","volume":"66","author":"SL Chowning","year":"2006","unstructured":"Chowning SL, Susil RC, Krieger A, Fichtinger G, Whitcomb LL, Atalar E (2006) A preliminary analysis and model of prostate injection distributions. Prostate 66(4): 344\u2013357","journal-title":"Prostate"},{"key":"598_CR6","doi-asserted-by":"crossref","unstructured":"Krieger A, Metzger G, Fichtinger G, Atalar E, Whitcomb LL (2006) A hybrid method for 6-DOF tracking of MRI-compatible robotic interventional devices. In: Proceedings of the IEEE international conference on robotics and automation, vol 2006. Orlando, FL, USA, pp 3844\u20133849","DOI":"10.1109\/ROBOT.2006.1642290"},{"key":"598_CR7","unstructured":"Krieger A, Susil R, Tanacs A, Fichtinger G, Whitcomb L, Atalar E (2002) A mri compatible device for MRI-guided transrectal prostate biopsy. International Society of Magnetic Resonance Imaging in Medicine, Tenth Scientific Meeting, Honolulu, p 338"},{"key":"598_CR8","doi-asserted-by":"crossref","unstructured":"Krieger A, Iulian I, Sang-Eun S, Bongjoon CN, Peter G, Gabor F, Louis W (2010) Development and preliminary evaluation of an actuated MRI-compatible robotic device for MRI-guided prostate intervention. ICRA, AK, US","DOI":"10.1109\/ROBOT.2010.5509727"},{"issue":"2","key":"598_CR9","doi-asserted-by":"crossref","first-page":"576","DOI":"10.1148\/radiol.2342031887","volume":"234","author":"D Beyersdorff","year":"2005","unstructured":"Beyersdorff D, Winkel A, Hamm B, Lenk S, Loening SA, Taupitz M (2005) MR imaging-guided prostate biopsy with a closed MR unit at 1.5T: Initial results. Radiology 234(2): 576\u2013581","journal-title":"Radiology"},{"issue":"6","key":"598_CR10","doi-asserted-by":"crossref","first-page":"1237","DOI":"10.1007\/s00330-005-0100-6","volume":"16","author":"K Engelhard","year":"2006","unstructured":"Engelhard K, Hollenbach HP, Kiefer B, Winkel A, Goeb K, Engehausen D (2006) Prostate biopsy in the supine position in a standard 1.5- T scanner under real time MR-imaging control using a MR-compatible endorectal biopsy device. Eur Radiol 16(6): 1237\u20131243","journal-title":"Eur Radiol"},{"key":"598_CR11","doi-asserted-by":"crossref","unstructured":"Elhawary H, Zivanovic A, Rea M, Davies B, Besant C, McRobbie D, de Souza N, Young I, Lamprth M (2006) The feasibility of MR image guided prostate biopsy using piezoceramic motors inside or near to the magnet isocentre. Int Conf Med Image Comput Comput Assist Interv 9(Pt 1):519\u2013526","DOI":"10.1007\/11866565_64"},{"issue":"2","key":"598_CR12","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1016\/S0022-5347(05)67366-1","volume":"164","author":"AV D\u2019Amico","year":"2000","unstructured":"D\u2019Amico AV, Tempany CM, Cormack R, Hata N, Jinzaki M, Tuncali K, Weinstein M, Richie JP (2000) Transperineal magnetic resonance image guided prostate biopsy. J Urol 164(2): 385\u2013387","journal-title":"J Urol"},{"issue":"3","key":"598_CR13","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1002\/mrm.20138","volume":"52","author":"R Susil","year":"2004","unstructured":"Susil R, Camphausen K, Choyke P, McVeigh E, GS GG, Ning H, Miller R, Atalar E, Coleman C, Menard C (2004) System for prostate brachytherapy and biopsy in a standard 1.5T MRI scanner. Magn Reson Med 52(3): 683\u2013687","journal-title":"Magn Reson Med"},{"key":"598_CR14","unstructured":"Chinzei K, Hata N, Jolesz FA, Kikinis R (2000) MRI-compatible surgical assist robot: system integration and preliminary feasibility study. In: Medical image computing and computer-assisted intervention (MICCAI), vol 1935, pp 921\u2013930"},{"issue":"1","key":"598_CR15","doi-asserted-by":"crossref","first-page":"15","DOI":"10.3109\/10929080601168254","volume":"12","author":"SP DiMaio","year":"2007","unstructured":"DiMaio SP, Pieper S, Chinzei K, Hata N, Haker SJ, Kacher DF, Fichtinger G, Tempany CM, Kikinis R (2007) Robot-assisted needle placement in open MRI: system architecture, integration and validation. Comput Aided Surg 12(1): 15\u201324","journal-title":"Comput Aided Surg"},{"key":"598_CR16","doi-asserted-by":"crossref","unstructured":"Tadakuma K, DeVita LSY, Dubowsky S (2008) The experimental study of a precision parallel manipulator with binary actuation: with application to MRI cancer treatment. In: Proceedings of the IEEE ICRA, Pasadena, USA","DOI":"10.1109\/ROBOT.2008.4543589"},{"issue":"4","key":"598_CR17","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1080\/13645700701520735","volume":"16","author":"D Stoianovici","year":"2007","unstructured":"Stoianovici D, Song D, Petrisor D, Ursu D, Mazilu D, Muntener M, Mutener M, Schar M, Patriciu A (2007) MRI stealth robot for prostate interventions. Minim Invasive Ther Allied Technol 16(4): 241\u2013248","journal-title":"Minim Invasive Ther Allied Technol"},{"issue":"3","key":"598_CR18","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1109\/TMECH.2008.924044","volume":"13","author":"GS Fischer","year":"2008","unstructured":"Fischer GS, Iordachita I, Csoma C, Tokuda J, DiMaio SP, Tempany CM, Hata N, Fichtinger G (2008) MRI-compatible pneumatic robot for transperineal prostate needle placement. IEEE\/ASME Trans Mechatron 13(3): 295\u2013305","journal-title":"IEEE\/ASME Trans Mechatron"},{"issue":"3","key":"598_CR19","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1109\/TMECH.2008.924122","volume":"13","author":"AA Goldenberg","year":"2008","unstructured":"Goldenberg AA, Trachtenberg J, Kucharczyk W, Yi Y, Haider M, Ma L, Weersink R, Raoufi C (2008) Robotic system for closed bore MRI-guided prostatic interventions. IEEE\/ASME Trans Mechatron 13(3): 374\u2013379","journal-title":"IEEE\/ASME Trans Mechatron"},{"issue":"5","key":"598_CR20","doi-asserted-by":"crossref","first-page":"N133","DOI":"10.1088\/0031-9155\/55\/5\/N02","volume":"55","author":"MR Bosch van den","year":"2010","unstructured":"van den Bosch MR, Moman MR, van Vulpen M, Battermann JJ, Duiveman E, van Schelven LJ, de Leeuw H, Lagendijk JJW, Moerland MA (2010) Mri-guided robotic system for transperineal prostate interventions: proof of principle. Phys Med Biol 55(5): N133\u2013N140","journal-title":"Phys Med Biol"},{"key":"598_CR21","unstructured":"Su H, Harrington K, Cole G, Fischer G (2010) Modular needle steering driver for MRI-guided transperineal prostate intervention, IEEE ICRA, Workshop on snakes, worms and catheters, Anchorage, AK"},{"key":"598_CR22","doi-asserted-by":"crossref","unstructured":"Su H, Zervas M, Cole G, Furlong C, Fischer G (2011) Real-time MRI-guided needle placement robot with integrated fiber optic force sensing. In: Proceedings of the IEEE international conference on robotics and automation (ICRA), China","DOI":"10.1109\/ICRA.2011.5979539"},{"issue":"1","key":"598_CR23","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1007\/s00330-004-2458-2","volume":"15","author":"S Zangos","year":"2005","unstructured":"Zangos S, Eichler K, Engelmann K, Ahmed M, Dettmer S, Herzog C, Pegios W, Wetter A, Lehnert T, Mack MG, Vogl TJ (2005) MRguided transgluteal biopsies with an open low-field system in patients with clinically suspected prostate cancer: technique and preliminary results. Eur Radiol 15(1): 174\u2013182","journal-title":"Eur Radiol"},{"issue":"4","key":"598_CR24","doi-asserted-by":"crossref","first-page":"1118","DOI":"10.1007\/s00330-006-0421-0","volume":"17","author":"S Zangos","year":"2007","unstructured":"Zangos S, Herzog C, Eichler K, Hammerstingl R, Lukoschek A, Guthmann S, Gutmann B, Schoepf UJ, Costello P, Vogl TJ (2007) MR-compatible assistance system for punction in a high-field system: device and feasibility transgluteal biopsies of the prostate gland. Euro Radiol 17(4): 1118\u20131124","journal-title":"Euro Radiol"},{"key":"598_CR25","unstructured":"Song S, Cho N, Ficsher G, Hata N, Tempany C, Fichtinger G, Iordachita I (2010) Development of a pneumatic robot for MRI-guided transperineal prostate biopsy and brachytherapy: new approaches. In: Proceedings of the IEEE international conference on robotics and automation, Anchorage, USA"},{"key":"598_CR26","unstructured":"Song S, Cho N, Tokuda J, Hata N, Tempany C, Fichtinger G, Iordachita I (2010) MRI compatibility study of a pneumatically actuated robotic system for transperineal prostate needle placement. Computer-assisted radiology and surgery (CARS), Geneva, Switzerland"},{"key":"598_CR27","doi-asserted-by":"crossref","unstructured":"Song S, Cho N, Tokuda J, Hata N, Tempany C, Fichtinger G, Iordachita I (2010) Preliminary evaluation of a MRI-compatible modular robotic system for MRI-guided prostate interventions. BioRob, Tokyo, Japan","DOI":"10.1109\/BIOROB.2010.5626987"},{"key":"598_CR28","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/j.media.2009.02.001","volume":"13","author":"R Kokes","year":"2009","unstructured":"Kokes R, Lister K, Gullapalli R, Zhang B, MacMillan A, Richard H, Desai JP (2009) Towards a teleoperated needle driver robot with haptic feedback for RFA of breast tumors under continuous MRI. Med Image Anal 13: 445\u2013455","journal-title":"Med Image Anal"},{"key":"598_CR29","doi-asserted-by":"crossref","unstructured":"Su H, Shang W, Cole G, Harrington K, Fischer G (2010) Haptic system design for MRI-guided needle based prostate brachytherapy. Haptic symposium","DOI":"10.1109\/HAPTIC.2010.5444612"},{"key":"598_CR30","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1243\/09544119JEIM468","volume":"223","author":"ZH Tse","year":"2009","unstructured":"Tse ZH, Elhawary H, Rea M, Young I, Davis BL, Lamperth M (2009) A haptic unit designed for magnetic resonance guided biopsy. IMechE 223: 159\u2013172","journal-title":"IMechE"},{"key":"598_CR31","unstructured":"Mewes P, Tokuda J, DiMaio SP, Fischer GS, Csoma C, Gobi DG, Tempany C, Fichtinger G, Hata N (2008) An integrated MRI and robot control software system for an MR-compatible robot in prostate intervention. In: Proceedings of the IEEE international conference on robotics and automation (ICRA)"},{"key":"598_CR32","doi-asserted-by":"crossref","unstructured":"Su H, Fischer G (2009) A 3-axis optical force\/torque sensor for prostate needle placement in magnetic resonance imaging environments. In: Proceedings of the 2nd annual IEEE international conference on technologies for practical robot applications, Boston, MA, USA, pp 5\u20139","DOI":"10.1109\/TEPRA.2009.5339654"},{"key":"598_CR33","unstructured":"Park Y-L, Elayaperumal S, Daniel BL, Kaye E, Pauly KB, Black RJ, Cutkosky MR (2008) MRI-compatible haptics: feasibility of using optical fiber Bragg grating strain-sensors to detect deflection of needles in an MRI environment, International Society for Magnetic Resonance in Medicine (ISMRM) 2008, Toronto, Canada"},{"issue":"4","key":"598_CR34","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1002\/rcs.274","volume":"5","author":"J Tokuda","year":"2009","unstructured":"Tokuda J, Fischer GS, Papademetris X, Yaniv Z, Ibanez L, Cheng P, Liu H, Blevins J, Arata J, Golby AJ, Kapur T, Pieper S, Burdette EC, Fichtinger G, Tempany CM, Hata N (2009) OpenIGTLink: an open network protocol for image-guided therapy environment. Int J Med Robotics Comput Assist Surg 5(4): 423\u2013434","journal-title":"Int J Med Robotics Comput Assist Surg"},{"key":"598_CR35","unstructured":"Tuncali K, Tokuda J, Iordachita I, Song SE, Fedorov A, Oguro S, Lasso A, Fennessy FM, Tang Y, Tempany CM, Hata N (2011) 3T MRI-guided transperineal trgeted prostate biopsy: clinical feasibility, safety, and early results, ISMRM"},{"key":"598_CR36","doi-asserted-by":"crossref","unstructured":"Tokuda J, Tuncali K, Iordachita I, Song SE, Fedorov A, Oguro S, Lasso A, Fennessy FM, Tang Y, Tempany CM, Hata N (2011) Preliminary accuracy evaluation of 3T MRI-guided transperineal prostate biopsy with grid template, ISMRM","DOI":"10.1088\/0031-9155\/57\/18\/5823"},{"key":"598_CR37","doi-asserted-by":"crossref","first-page":"370","DOI":"10.3109\/10929080109146306","volume":"6","author":"K Masamune","year":"2001","unstructured":"Masamune K, Fichtinger G, Patriciu A, Sakuma I, Dohi T, Stoianovici D (2001) System for robotically assisted percutaneous procedures with computed tomography guidance. J Comp Aided Surg 6: 370\u2013383","journal-title":"J Comp Aided Surg"},{"issue":"8","key":"598_CR38","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1016\/j.eursup.2007.09.001","volume":"7","author":"TH Van der Kwasta","year":"2008","unstructured":"Van der Kwasta TH, Woltersc T, Evansa A, Roobolc M (2008) Single prostatic cancer foci on prostate biopsy. Eur Urol Suppl 7(8): 549\u2013556","journal-title":"Eur Urol Suppl"},{"key":"598_CR39","doi-asserted-by":"crossref","unstructured":"Xu H, Lasso A, Vikal S, Guion P, Krieger A, Kaushal A, Whitcomb LL, Fichtinger G (2010) MRI-guided robotic prostate biopsy: a clinical accuracy validation. Medical image computing and computer-assisted intervention (MICCAI), pp 383\u2013391","DOI":"10.1007\/978-3-642-15711-0_48"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-011-0598-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-011-0598-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-011-0598-9","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,12]],"date-time":"2019-06-12T03:28:19Z","timestamp":1560310099000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-011-0598-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,6,23]]},"references-count":39,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2012,3]]}},"alternative-id":["598"],"URL":"https:\/\/doi.org\/10.1007\/s11548-011-0598-9","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,6,23]]}}}