{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T13:21:10Z","timestamp":1777555270005,"version":"3.51.4"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2011,7,23]],"date-time":"2011-07-23T00:00:00Z","timestamp":1311379200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2012,5]]},"DOI":"10.1007\/s11548-011-0645-6","type":"journal-article","created":{"date-parts":[[2011,7,22]],"date-time":"2011-07-22T03:53:09Z","timestamp":1311306789000},"page":"371-387","source":"Crossref","is-referenced-by-count":17,"title":["Robust bronchoscope motion tracking using sequential Monte Carlo methods in navigated bronchoscopy: dynamic phantom and patient validation"],"prefix":"10.1007","volume":"7","author":[{"given":"Xi\u00f3ngbi\u0101o","family":"Lu\u00f3","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marco","family":"Feuerstein","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takayuki","family":"Kitasaka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kensaku","family":"Mori","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2011,7,23]]},"reference":[{"key":"645_CR1","unstructured":"American Cancer Society (2010) Global cancer facts & figures 2010, American Cancer Society, Atlanta. http:\/\/www.cancer.org\/Research\/CancerFactsFigures"},{"issue":"6","key":"645_CR2","first-page":"809","volume":"79-D","author":"K Mori","year":"1996","unstructured":"Mori K, Urano A, Hasegawa J, Toriwaki J, Anno H, Katada K (1996) Virtualized endoscope system\u2014an application of virtual reality technology to diagnostic aid. IEICE Trans Inf Syst E 79-D(6): 809\u2013819","journal-title":"IEICE Trans Inf Syst E"},{"key":"645_CR3","doi-asserted-by":"crossref","first-page":"1153","DOI":"10.1016\/S1076-6332(03)80517-2","volume":"9","author":"AP Kiraly","year":"2002","unstructured":"Kiraly AP, Higgins WE, McLennan G, Hoffman EA, Reinhardt JM (2002) Three-dimensional human airway segmentation methods for cinical virtual bronchoscopy. Acad Radiol 9: 1153\u20131168","journal-title":"Acad Radiol"},{"key":"645_CR4","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1016\/j.acra.2004.01.012","volume":"11","author":"D Mayer","year":"2004","unstructured":"Mayer D, Bartz D, Fischer J, Ley S, del Rio A, Thust S, Kauczor H-U, Heussel CP (2004) Hybrid segmentation and virtual bronchoscopy based on CT images. Acad Radiol 11: 551\u2013565","journal-title":"Acad Radiol"},{"issue":"11","key":"645_CR5","doi-asserted-by":"crossref","first-page":"1462","DOI":"10.1109\/TMI.2006.883452","volume":"25","author":"F Deligianni","year":"2006","unstructured":"Deligianni F, Chung AJ, Yang GZ (2006) Nonrigid 2-D\/3-D registration for patient specific bronchoscopy simulation with statistical shape modeling: phantom validation. IEEE Trans Med Imaging 25(11): 1462\u20131471","journal-title":"IEEE Trans Med Imaging"},{"key":"645_CR6","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1016\/j.cviu.2006.10.010","volume":"108","author":"J Helferty","year":"2007","unstructured":"Helferty J, Sherbondy A, Kiraly A, Higgins W (2007) Computer-based system for the virtual-endoscopic guidance of bronchoscopy. Comput Vis Image Underst 108: 171\u2013187","journal-title":"Comput Vis Image Underst"},{"key":"645_CR7","doi-asserted-by":"crossref","first-page":"786","DOI":"10.1016\/j.acra.2008.03.001","volume":"15","author":"MJ Suter","year":"2008","unstructured":"Suter MJ, Reinhardt JM, McLennan G (2008) Integrated CT\/bronchoscopy in the central airways: preliminary results. Acad Radiol 15: 786\u2013798","journal-title":"Acad Radiol"},{"issue":"4","key":"645_CR8","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1016\/j.media.2009.06.001","volume":"13","author":"D Deguchi","year":"2009","unstructured":"Deguchi D, Mori K, Feuerstein M, Kitasaka T, Maurer CR Jr, Suenaga Y, Takabatake H, Mori M, Natori H (2009) Selective image similarity measure for bronchoscope tracking based on image registration. Med Image Anal 13(4): 621\u2013633","journal-title":"Med Image Anal"},{"issue":"6","key":"645_CR9","doi-asserted-by":"crossref","first-page":"1783","DOI":"10.1378\/chest.118.6.1783","volume":"118","author":"SB Solomon","year":"2000","unstructured":"Solomon SB, White JP, Wiener CM, Orens JB, Wang KP (2000) Three-dimensionsal CT-guided bronchoscopy with a real-time electromagnetic position sensor: a comparison of two image registration methods. Chest 118(6): 1783\u20131787","journal-title":"Chest"},{"issue":"4","key":"645_CR10","doi-asserted-by":"crossref","first-page":"988","DOI":"10.1378\/chest.129.4.988","volume":"129","author":"Y Schwarz","year":"2006","unstructured":"Schwarz Y, Greif J, Becker HD, Ernst A, Mehta A (2006) Real-time electromagnetic navigation bronchoscopy to peripheral lung lesions using overlaid CT images: the first human study. Chest 129(4): 988\u2013994","journal-title":"Chest"},{"key":"645_CR11","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1016\/j.acra.2006.12.004","volume":"14","author":"EB Levy","year":"2007","unstructured":"Levy EB, Tang J, Lindisch D, Glossop N, Banovac F, Cleary K (2007) Implementation of an electromagnetic tracking system for accurate intrahepatic puncture needle guidance: accuracy results in an in vitro model. Acad Radiol 14: 344\u2013354","journal-title":"Acad Radiol"},{"issue":"4","key":"645_CR12","doi-asserted-by":"crossref","first-page":"922","DOI":"10.1109\/TBME.2009.2035688","volume":"57","author":"Z Yaniv","year":"2010","unstructured":"Yaniv Z, Cheng P, Wilson E, Popa T, Lindisch D, Campos-Nanez E, Abeledo H, Watson V, Cleary K, Banovac F (2010) Needle-based interventions with the image-guided surgery toolkit (IGSTK): from phantoms to clinical trials. IEEE Trans Biomed Eng 57(4): 922\u2013933","journal-title":"IEEE Trans Biomed Eng"},{"key":"645_CR13","doi-asserted-by":"crossref","first-page":"1282","DOI":"10.1016\/j.acra.2010.05.017","volume":"17","author":"SA Muller","year":"2010","unstructured":"Muller SA, Maier-Hein L, Tekbas A, Seitel A, Ramsauer S, Radeleff B, Franz AM, Tetzlaff R, Mehrabi A, Wolf I, Kauczor H-U, Meinzer H-P, Schmied BM (2010) Navigated liver biopsy using a novel soft tissue navigation system versus CT-guided liver biopsy in a porcine model: a prospective randomized trial. Acad Radiol 17: 1282\u20131287","journal-title":"Acad Radiol"},{"key":"645_CR14","doi-asserted-by":"crossref","unstructured":"Mori K, Deguchi D, Akiyama K, Kitasaka T, Maurer CR Jr, Suenaga Y, Takabatake H, Mori M, Natori H (2005) Hybrid bronchoscope tracking using a magnetic tracking sensor and image registration. In: Proceedings of MICCAI 2005, vol LNCS 3750. pp 543\u2013550","DOI":"10.1007\/11566489_67"},{"issue":"3","key":"645_CR15","doi-asserted-by":"crossref","first-page":"736","DOI":"10.1109\/TBME.2009.2034733","volume":"57","author":"TD Soper","year":"2010","unstructured":"Soper TD, Haynor DR, Glenny RW, Seibel EJ (2010) In vivo validation of a hybrid tracking system for navigation of an ultrathin bronchoscope within peripheral airways. IEEE Trans Biomed Eng 57(3): 736\u2013745","journal-title":"IEEE Trans Biomed Eng"},{"issue":"3","key":"645_CR16","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1007\/BF01409422","volume":"5","author":"VV Kindratenko","year":"2000","unstructured":"Kindratenko VV (2000) A survey of electromagnetic position tracker calibration techniques. Virtual Real 5(3): 169\u2013182","journal-title":"Virtual Real"},{"issue":"6","key":"645_CR17","doi-asserted-by":"crossref","first-page":"951","DOI":"10.1109\/TMI.2008.2008954","volume":"28","author":"M Feuerstein","year":"2009","unstructured":"Feuerstein M, Reichl T, Vogel J, Traub J, Navab N (2009) Magneto-optical tracking of flexible laparoscopic ultrasound: model-based online detection and correction of magnetic tracking errors. IEEE Trans Med Imaging 28(6): 951\u2013967","journal-title":"IEEE Trans Med Imaging"},{"key":"645_CR18","unstructured":"Luo X, Reichl T, Feuerstein M, Kitasaka T, Mori K (2010) Modified hybrid bronchoscope tracking based on sequential monte carlo sampler: dynamic phantom validation. In: Proceedings of ACCV 2010, vol 3. pp 1722\u20131733"},{"issue":"3","key":"645_CR19","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1023\/A:1008935410038","volume":"10","author":"CA Arnaud Doucet","year":"2000","unstructured":"Arnaud Doucet CA, Godsill S (2000) On sequential Monte Carlo sampling methods for Bayesian filtering. Stat Comput 10(3): 197\u2013208","journal-title":"Stat Comput"},{"key":"645_CR20","doi-asserted-by":"crossref","DOI":"10.1007\/978-1-4757-3437-9","volume-title":"Sequential Monte Carlo methods in practice","author":"A Doucet","year":"2001","unstructured":"Doucet A, de Freitas N, Gordon N (2001) Sequential Monte Carlo methods in practice. Springer, Berlin"},{"issue":"443","key":"645_CR21","doi-asserted-by":"crossref","first-page":"1032","DOI":"10.1080\/01621459.1998.10473765","volume":"93","author":"JS Liu","year":"1998","unstructured":"Liu JS, Chen R (1998) Sequential Monte Carlo methods for dynamic systems. J Am Stat Assoc 93(443): 1032\u20131044","journal-title":"J Am Stat Assoc"},{"key":"645_CR22","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1109\/78.978374","volume":"50","author":"M Arulampalam","year":"2002","unstructured":"Arulampalam M et\u00a0al (2002) A tutorial on particle filters for nonlinear\/non-gaussian Bayesian tracking. IEEE Trans Signal Process 50: 174\u2013188","journal-title":"IEEE Trans Signal Process"},{"key":"645_CR23","doi-asserted-by":"crossref","DOI":"10.1017\/CBO9780511811685","volume-title":"Multiple view geometry in computer vision","author":"R Hartley","year":"2004","unstructured":"Hartley R, Zisserman A (2004) Multiple view geometry in computer vision. Cambridge University Press, Cambridge"},{"issue":"3","key":"645_CR24","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1145\/195784.197480","volume":"13","author":"JC Hart","year":"1994","unstructured":"Hart JC, Francis GK, Kauffman LH (1994) Visualizing quaternion rotation. ACM Trans Graph 13(3): 256\u2013276","journal-title":"ACM Trans Graph"},{"key":"645_CR25","volume-title":"Visualizing quaternions","author":"AJ Hanson","year":"2006","unstructured":"Hanson AJ (2006) Visualizing quaternions. Morgan-Kaufmann\/ Elsevier, Los Altos"},{"issue":"1","key":"645_CR26","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1023\/A:1008078328650","volume":"29","author":"M Isard","year":"1998","unstructured":"Isard M, Blake A (1998) Condensation\u2014conditional density propagation for visual tracking. Int J Comput Vis 29(1): 5\u201328","journal-title":"Int J Comput Vis"},{"key":"645_CR27","unstructured":"Luo X, Feuerstein M, Deguchi D, Kitasaka T, Takabatake H, Mori K Development and comparison of new hybrid motion tracking for bronchoscopic navigation. Med Image Anal (in press)"},{"key":"645_CR28","doi-asserted-by":"crossref","unstructured":"Mori K, Suenaga Y, Toriwaki J (2003) Fast software-based volume rendering using multimedia instructions on PC platforms and its application to virtual endoscopy. In: Proceedings of SPIE, vol 5031. pp 111\u2013122","DOI":"10.1117\/12.480417"},{"key":"645_CR29","doi-asserted-by":"crossref","unstructured":"Luo X, Feuerstein M, Sugiura T, Kitasaka T, Imaizumi K, Hasegawa Y, Mori K (2010) Towards hybrid bronchoscope tracking under respiratory motion: evaluation on a dynamic motion phantom. In: Proceedings of SPIE, vol 7625. p 76251B","DOI":"10.1117\/12.844139"},{"key":"645_CR30","doi-asserted-by":"crossref","unstructured":"Schneider M, Stevens C (2007) Development and testing of a new magnetic-tracking device for image guidance. In: Proceedings of SPIE, vol 6509. p 65090I","DOI":"10.1117\/12.713249"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-011-0645-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-011-0645-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-011-0645-6","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,13]],"date-time":"2019-06-13T05:41:50Z","timestamp":1560404510000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-011-0645-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,7,23]]},"references-count":30,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2012,5]]}},"alternative-id":["645"],"URL":"https:\/\/doi.org\/10.1007\/s11548-011-0645-6","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,7,23]]}}}