{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T02:32:13Z","timestamp":1761964333662},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2011,10,19]],"date-time":"2011-10-19T00:00:00Z","timestamp":1318982400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2012,7]]},"DOI":"10.1007\/s11548-011-0661-6","type":"journal-article","created":{"date-parts":[[2011,10,18]],"date-time":"2011-10-18T11:09:21Z","timestamp":1318936161000},"page":"611-620","source":"Crossref","is-referenced-by-count":20,"title":["A motion constrained cross-wire phantom for tracked 2D ultrasound calibration"],"prefix":"10.1007","volume":"7","author":[{"given":"Eivind Lyche","family":"Melv\u00e6r","sequence":"first","affiliation":[]},{"given":"Knut","family":"M\u00f8rken","sequence":"additional","affiliation":[]},{"given":"Eigil","family":"Samset","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2011,10,19]]},"reference":[{"issue":"12","key":"661_CR1","doi-asserted-by":"crossref","first-page":"1615","DOI":"10.1016\/S0301-5629(01)00483-5","volume":"27","author":"D Atkinson","year":"2001","unstructured":"Atkinson D, Burcher M, Declerck J, Noble JA (2001) Respiratory motion compensation for 3-d freehand echocardiography. Ultrasound Med Biol 27(12): 1615\u20131620. doi: 10.1016\/S0301-5629(01)00483-5","journal-title":"Ultrasound Med Biol"},{"issue":"3","key":"661_CR2","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1109\/TMI.2005.862736","volume":"25","author":"DC Barratt","year":"2006","unstructured":"Barratt DC, Penney GP, Chan CSK, Slomszykowski M, Carter TJ, Edwards PJ, Hawkes DJ (2006) Self-calibrating 3d-ultrasound-based bone registration for minimally invasive orthopedic surgery. IEEE Trans Med Imaging 25(3): 312\u2013323","journal-title":"IEEE Trans Med Imaging"},{"key":"661_CR3","doi-asserted-by":"crossref","unstructured":"Blackall JM, Rueckert D, Maurer CR Jr, Penney GP, Hill DLG, Hawkes DJ (2000) An image registration approach to automated calibration for freehand 3d ultrasound. In: MICCAI \u201900: proceedings of the third international conference on medical image computing and computer-assisted intervention. Springer, London, pp 462\u2013471","DOI":"10.1007\/978-3-540-40899-4_47"},{"key":"661_CR4","doi-asserted-by":"crossref","unstructured":"Boctor EM, Fichtinger G, Taylor RH, Choti MA (2003) Tracked 3D ultrasound in radio-frequency liver ablation. In: Walker WF, Insana MF (eds) Society of photo-optical instrumentation engineers (SPIE) conference series, society of photo-optical instrumentation engineers (SPIE) conference series, vol 5035. pp 174\u2013182. doi: 10.1117\/12.479952","DOI":"10.1117\/12.479952"},{"key":"661_CR5","first-page":"872","volume":"49","author":"B Brendel","year":"2004","unstructured":"Brendel B, Winter S, Ermert H (2004) A simple and accurate calibration method for 3d freehand ultrasound. Biomed Tech 49: 872\u2013873","journal-title":"Biomed Tech"},{"issue":"6","key":"661_CR6","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1109\/TPAMI.1986.4767851","volume":"8","author":"J Canny","year":"1986","unstructured":"Canny J (1986) A computational approach to edge detection. IEEE Trans Pattern Anal Mach Intell 8(6): 679\u2013698. doi: 10.1109\/TPAMI.1986.4767851","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"issue":"9","key":"661_CR7","doi-asserted-by":"crossref","first-page":"923","DOI":"10.1016\/0301-5629(94)90052-3","volume":"20","author":"PR Detmer","year":"1994","unstructured":"Detmer PR, Bashein G, Hodges T, Beach KW, Filer EP, Burns DH, Strandness DE Jr (1994) 3d ultrasonic image feature localization based on magnetic scanhead tracking: in vitro calibration and validation. Ultrasound Med Biol 20(9): 923\u2013936","journal-title":"Ultrasound Med Biol"},{"issue":"1","key":"661_CR8","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1145\/361237.361242","volume":"15","author":"RO Duda","year":"1972","unstructured":"Duda RO, Hart PE (1972) Use of the hough transformation to detect lines and curves in pictures. Commun ACM 15(1): 11\u201315","journal-title":"Commun ACM"},{"key":"661_CR9","first-page":"487","volume-title":"GNU scientific library reference manual, revised 2nd edn, chap 37","author":"M Galassi","year":"2005","unstructured":"Galassi M, Davies J, Theiler J, Gough B, Jungman G, Booth M, Rossi F (2005) GNU scientific library reference manual, revised 2nd edn, chap 37. Network Theory Limited, UK, pp, pp 487\u2013500"},{"issue":"4","key":"661_CR10","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1016\/j.ultrasmedbio.2004.12.022","volume":"31","author":"AH Gee","year":"2005","unstructured":"Gee AH, Houghton NE, Treece GM, Prager RW (2005) A mechanical instrument for 3d ultrasound probe calibration. Ultrasound Med Biol 31(4): 505\u2013518","journal-title":"Ultrasound Med Biol"},{"key":"661_CR11","doi-asserted-by":"crossref","first-page":"1133","DOI":"10.1016\/S0301-5629(00)00248-9","volume":"26","author":"A Goldstein","year":"2000","unstructured":"Goldstein A (2000) The effect of acoustic velocity on phantom measurements. Ultrasound Med Biol 26: 1133\u20131143","journal-title":"Ultrasound Med Biol"},{"issue":"7","key":"661_CR12","doi-asserted-by":"crossref","first-page":"919","DOI":"10.1016\/j.ultrasmedbio.2005.04.007","volume":"31","author":"MJ Gooding","year":"2005","unstructured":"Gooding MJ, Kennedy SH, Noble JA (2005) Temporal calibration of freehand three-dimensional ultrasound using image alignment. Ultrasound Med Biol 31(7): 919\u2013927. doi: 10.1016\/j.ultrasmedbio.2005.04.007","journal-title":"Ultrasound Med Biol"},{"key":"661_CR13","unstructured":"Hsu PW (2007) Freehand three-dimensional ultrasound calibration. PhD thesis, University of Cambridge"},{"key":"661_CR14","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1016\/j.ultrasmedbio.2007.07.020","volume":"34","author":"PW Hsu","year":"2008","unstructured":"Hsu PW, Prager RW, Gee AH, Treece GM (2008) Real-time freehand 3d ultrasound calibration. Ultrasound Med Biol 34: 239\u2013251","journal-title":"Ultrasound Med Biol"},{"issue":"4","key":"661_CR15","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1016\/j.ultrasmedbio.2004.11.015","volume":"31","author":"L Mercier","year":"2005","unstructured":"Mercier L, Lang\u00f8 T, Lindseth F, Collins DL (2005) A review of calibration techniques for freehand 3-d ultrasound systems. Ultrasound Med Biol 31(4): 449\u2013471","journal-title":"Ultrasound Med Biol"},{"issue":"2","key":"661_CR16","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1007\/s11548-009-0285-2","volume":"4","author":"S Milko","year":"2009","unstructured":"Milko S, Melv\u00e6r EL, Samset E, Kadir T (2009) Evaluation of bivariate correlation ratio similarity metric for rigid registration of us\/mr images of the liver. Int J Comput Assist Radiol Surg 4(2): 147\u2013155","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"661_CR17","unstructured":"Mor\u00e9 JJ (1978) Numerical analysis, lecture notes in mathematics, vol 630, chap. The Levenberg-Marquardt algorithm: implementation and theory. Springer, Berlin, pp 105\u2013116"},{"issue":"6","key":"661_CR18","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1016\/S0301-5629(98)00044-1","volume":"24","author":"RW Prager","year":"1998","unstructured":"Prager RW, Rohling RN, Gee AH, Berman L (1998) Rapid calibration for 3-d freehand ultrasound. Ultrasound Med Biol 24(6): 855\u2013869. doi: 10.1016\/S0301-5629(98)00044-1","journal-title":"Ultrasound Med Biol"},{"issue":"7","key":"661_CR19","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1016\/j.ultrasmedbio.2007.02.015","volume":"33","author":"OV Solberg","year":"2007","unstructured":"Solberg OV, Lindseth F, Torp H, Blake RE, Hernes TAN (2007) Freehand 3d ultrasound reconstruction algorithms\u2014a review. Ultrasound Med Biol 33(7): 991\u20131009","journal-title":"Ultrasound Med Biol"},{"key":"661_CR20","unstructured":"Tehnical specifications of the Aurora tracking system. http:\/\/www.ndigital.com\/medical\/aurora-techspecs-performance.php"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-011-0661-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-011-0661-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-011-0661-6","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,1]],"date-time":"2019-06-01T12:35:54Z","timestamp":1559392554000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-011-0661-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,10,19]]},"references-count":20,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2012,7]]}},"alternative-id":["661"],"URL":"https:\/\/doi.org\/10.1007\/s11548-011-0661-6","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,10,19]]}}}