{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T06:08:15Z","timestamp":1760249295367},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2013,4,21]],"date-time":"2013-04-21T00:00:00Z","timestamp":1366502400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2013,11]]},"DOI":"10.1007\/s11548-013-0843-5","type":"journal-article","created":{"date-parts":[[2013,4,20]],"date-time":"2013-04-20T10:03:26Z","timestamp":1366452206000},"page":"905-916","source":"Crossref","is-referenced-by-count":10,"title":["Cerebrovascular segmentation and planning of depth electrode insertion for epilepsy surgery"],"prefix":"10.1007","volume":"8","author":[{"given":"Xiaofei","family":"Du","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hui","family":"Ding","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wenjing","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guangming","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guangzhi","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2013,4,21]]},"reference":[{"key":"843_CR1","unstructured":"Sirven JI, Pedley TA, Wilterdink JL (2011) Evaluation and management of drug-resistant epilepsy. Available at: http:\/\/www.uptodate.com\/contents\/evaluation-and-management-of-drug-resistant-epilepsy . Accessed Apr 15 2011"},{"issue":"6","key":"843_CR2","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1109\/79.962275","volume":"18","author":"S Baillet","year":"2001","unstructured":"Baillet S, Mosher JC, Leahy RM (2001) Electromagnetic brain mapping. IEEE Sign Process Mag 18(6):14\u201330","journal-title":"IEEE Sign Process Mag"},{"issue":"8","key":"843_CR3","doi-asserted-by":"crossref","first-page":"553","DOI":"10.1111\/j.1445-2197.1996.tb00808.x","volume":"66","author":"JV Rosenfeld","year":"1996","unstructured":"Rosenfeld JV (1996) Minimally invasive neurosurgery. Aust N Z J Surg 66(8):553\u2013559","journal-title":"Aust N Z J Surg"},{"key":"843_CR4","doi-asserted-by":"crossref","DOI":"10.1017\/CBO9781139021951","volume-title":"Techniques in epilepsy surgery: the MNI approach","author":"A Olivier","year":"2012","unstructured":"Olivier A, Boling WW, Tanriverdi T (2012) Techniques in epilepsy surgery: the MNI approach. Cambridge University Press, Cambridge"},{"issue":"4","key":"843_CR5","doi-asserted-by":"crossref","first-page":"1088","DOI":"10.1227\/NEU.0b013e3181ecc887","volume":"67","author":"H Bront\u00eb-Stewart","year":"2010","unstructured":"Bront\u00eb-Stewart H, Louie S, Batya S, Henderson JM (2010) Clinical motor outcome of bilateral subthalamic nucleus deep-brain stimulation for Parkinson\u2019s disease using image-guided frameless stereotaxy. Neurosurgery 67(4):1088","journal-title":"Neurosurgery"},{"key":"843_CR6","doi-asserted-by":"crossref","unstructured":"Chakravarty MM, Sadikot AF, Mongia S, Bertrand G, Collins DL (2006) Towards a multi-modal atlas for neurosurgical planning. In: Medical image computing and computer-assisted intervention-MICCAI 2006. Springer, pp 389\u2013396","DOI":"10.1007\/11866763_48"},{"issue":"3","key":"843_CR7","doi-asserted-by":"crossref","first-page":"404","DOI":"10.3171\/jns.2005.103.3.0404","volume":"103","author":"KL Holloway","year":"2005","unstructured":"Holloway KL, Gaede SE, Starr PA, Rosenow JM, Ramakrishnan V, Henderson JM (2005) Frameless stereotaxy using bone fiducial markers for deep brain stimulation. J Neurosurg 103(3):404\u2013413","journal-title":"J Neurosurg"},{"issue":"S14","key":"843_CR8","doi-asserted-by":"crossref","first-page":"S247","DOI":"10.1002\/mds.20959","volume":"21","author":"A Machado","year":"2006","unstructured":"Machado A, Rezai AR, Kopell BH, Gross RE, Sharan AD, Benabid AL (2006) Deep brain stimulation for Parkinson\u2019s disease: surgical technique and perioperative management. Mov Disord 21(S14):S247\u2013S258","journal-title":"Mov Disord"},{"key":"843_CR9","doi-asserted-by":"crossref","unstructured":"Liu Y, Dawant BM, Pallavaram S, Neimat JS, Konrad PE, D\u2019Haese P-F, Datteri RD, Landman BA, Noble JH A surgeon specific automatic path planning algorithm for deep brain stimulation. In: SPIE medical imaging, 2012. international society for optics and photonics, pp 83161D\u201383161D","DOI":"10.1117\/12.911705"},{"key":"843_CR10","doi-asserted-by":"crossref","unstructured":"Brunenberg EJ, Vilanova A, Visser-Vandewalle V, Temel Y, Ackermans L, Platel B, ter Haar Romeny BM (2007) Automatic trajectory planning for deep brain stimulation: a feasibility study. In: Medical image computing and computer-assisted intervention-MICCAI 2007. Springer, pp 584\u2013592","DOI":"10.1007\/978-3-540-75757-3_71"},{"issue":"4","key":"843_CR11","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1007\/s11548-011-0651-8","volume":"7","author":"C Essert","year":"2012","unstructured":"Essert C, Haegelen C, Lalys F, Abadie A, Jannin P (2012) Automatic computation of electrode trajectories for Deep Brain Stimulation: a hybrid symbolic and numerical approach. Int J Comput Assist Radiol Surg 7(4):517\u2013532","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"843_CR12","doi-asserted-by":"crossref","first-page":"2885","DOI":"10.1118\/1.4704643","volume":"39","author":"RR Shamir","year":"2012","unstructured":"Shamir RR, Joskowicz L, Tamir I, Dabool E, Pertman L, Ben-Ami A, Shoshan Y (2012) Reduced risk trajectory planning in image-guided keyhole neurosurgery. Med Phys 39:2885","journal-title":"Med Phys"},{"issue":"5","key":"843_CR13","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1007\/s11548-012-0768-4","volume":"7","author":"S B\u00e9riault","year":"2012","unstructured":"B\u00e9riault S, Al Subaie F (2012) A multi-modal approach to computer-assisted deep brain stimulation trajectory planning. Int J Comput Assist Radiol Surg 7(5):687\u2013704","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"6","key":"843_CR14","doi-asserted-by":"crossref","first-page":"631","DOI":"10.1046\/j.1528-1157.2002.26101.x","volume":"43","author":"ML Smith","year":"2002","unstructured":"Smith ML, Elliott IM, Lach L (2002) Cognitive skills in children with intractable epilepsy: comparison of surgical and nonsurgical candidates. Epilepsia 43(6):631\u2013637","journal-title":"Epilepsia"},{"issue":"3","key":"843_CR15","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1097\/00002142-200106000-00005","volume":"12","author":"NG Campeau","year":"2001","unstructured":"Campeau NG, Huston J III (2001) Magnetic resonance angiography at 3.0 Tesla: initial clinical experience. Top Magn Reson Imag 12(3):183\u2013204","journal-title":"Top Magn Reson Imag"},{"key":"843_CR16","doi-asserted-by":"crossref","unstructured":"Essig M, Giesel FL (2008) Head and neck MRA. In: Clinical blood pool MR imaging. Springer, pp 59\u201368","DOI":"10.1007\/978-3-540-77861-5_6"},{"issue":"6","key":"843_CR17","first-page":"322","volume":"8","author":"JH Maki","year":"1996","unstructured":"Maki JH, Chenevert TL, Prince MR (1996) Three-dimensional contrast-enhanced MR angiography. Top Magn Reson Imag 8(6):322\u2013344","journal-title":"Top Magn Reson Imag"},{"issue":"1","key":"843_CR18","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1102\/1470-7330.2007.0019","volume":"7","author":"HS Thomsen","year":"2007","unstructured":"Thomsen HS, Marckmann P, Logager VB (2007) Nephrogenic systemic fibrosis (NSF): a late adverse reaction to some of the gadolinium based contrast agents. Cancer Imag 7(1):130","journal-title":"Cancer Imag"},{"key":"843_CR19","doi-asserted-by":"crossref","unstructured":"Vu D, Gonz\u00e1lez RG, Schaefer PW (2006) Conventional MRI and MR angiography of stroke. In: Acute ischemic stroke. Springer, pp 115\u2013137","DOI":"10.1007\/3-540-30810-5_6"},{"issue":"2","key":"843_CR20","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1002\/mrm.1910140206","volume":"14","author":"DG Nishimura","year":"2005","unstructured":"Nishimura DG (2005) Time-of-flight MR angiography. Magn Reson Med 14(2):194\u2013201","journal-title":"Magn Reson Med"},{"issue":"1","key":"843_CR21","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1148\/radiology.204.1.9205259","volume":"204","author":"JR Reichenbach","year":"1997","unstructured":"Reichenbach JR, Venkatesan R, Schillinger DJ, Kido DK, Haacke EM (1997) Small vessels in the human brain: MR venography with deoxyhemoglobin as an intrinsic contrast agent. Radiology 204(1):272\u2013277","journal-title":"Radiology"},{"key":"843_CR22","volume-title":"Magnetic resonance angiography: a practical approach","author":"EK Yucel","year":"1995","unstructured":"Yucel EK (1995) Magnetic resonance angiography: a practical approach. McGraw-Hill, Health Professions Division, New York"},{"issue":"3","key":"843_CR23","doi-asserted-by":"crossref","first-page":"784","DOI":"10.1002\/mrm.22825","volume":"66","author":"A Ng","year":"2011","unstructured":"Ng A, Johnston L, Chen Z, Cho ZH, Zhang J, Egan G (2011) Spatially dependent filtering for removing phase distortions at the cortical surface. Magn Reson Med 66(3):784\u2013793","journal-title":"Magn Reson Med"},{"issue":"3","key":"843_CR24","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1016\/S1064-9689(21)00252-X","volume":"3","author":"C Dumoulin","year":"1995","unstructured":"Dumoulin C (1995) Phase contrast MR angiography techniques. Magn Reson Imag Clin N Am 3(3):399","journal-title":"Magn Reson Imag Clin N Am"},{"key":"843_CR25","doi-asserted-by":"crossref","unstructured":"Pernicone J, Siebert JE, Potchen E, Pera A, Dumoulin C, Souza S (1990) Three-dimensional phase-contrast MR angiography in the head and neck: preliminary report. Am J Roentgenol 155(1): 167\u2013176","DOI":"10.2214\/ajr.155.1.2112840"},{"key":"843_CR26","doi-asserted-by":"crossref","unstructured":"Ross DA, Brunberg JA, Drury I, Henry TR (1996) Intracerebral depth electrode monitoring in partial epilepsy: the morbidity and efficacy of placement using magnetic resonance image-guided stereotactic surgery. Neurosurgery 39(2):327\u2013334","DOI":"10.1097\/00006123-199608000-00018"},{"issue":"2","key":"843_CR27","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/0098-3004(84)90020-7","volume":"10","author":"JC Bezdek","year":"1984","unstructured":"Bezdek JC, Ehrlich R, Full W (1984) FCM: the fuzzy c-means clustering algorithm. Comput Geosci 10(2):191\u2013203","journal-title":"Comput Geosci"},{"issue":"5","key":"843_CR28","doi-asserted-by":"crossref","first-page":"672","DOI":"10.1109\/72.159057","volume":"3","author":"LO Hall","year":"1992","unstructured":"Hall LO, Bensaid AM, Clarke LP, Velthuizen RP, Silbiger MS, Bezdek JC (1992) A comparison of neural network and fuzzy clustering techniques in segmenting magnetic resonance images of the brain. IEEE Trans Neural Netw 3(5):672\u2013682","journal-title":"IEEE Trans Neural Netw"},{"key":"843_CR29","doi-asserted-by":"crossref","unstructured":"Frangi AF, Niessen WJ, Vincken KL, Viergever MA (1998) Multiscale vessel enhancement filtering. In: Medical image computing and computer-assisted interventation-MICCAI\u201998. Springer, pp 130\u2013137","DOI":"10.1007\/BFb0056195"},{"key":"843_CR30","doi-asserted-by":"crossref","unstructured":"Enquobahrie A, Ibanez L, Bullitt E, Aylward S (2007) Vessel enhancing diffusion filter. Insight J. http:\/\/www.insight-journal.com\/download\/pdf\/6321\/VEDArticle2.pdf","DOI":"10.54294\/7bbkq8"},{"issue":"3","key":"843_CR31","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1145\/78964.78965","volume":"9","author":"M Levoy","year":"1990","unstructured":"Levoy M (1990) Efficient ray tracing of volume data. ACM Trans Graph (TOG) 9(3):245\u2013261","journal-title":"ACM Trans Graph (TOG)"},{"key":"843_CR32","doi-asserted-by":"crossref","unstructured":"Marks MP, Pelc NJ, Ross MR, Enzmann DR (1992) Determination of cerebral blood flow with a phase-contrast cine MR imaging technique: evaluation of normal subjects and patients with arteriovenous malformations. Radiology 182(2):467\u2013476","DOI":"10.1148\/radiology.182.2.1732966"},{"key":"843_CR33","doi-asserted-by":"crossref","unstructured":"Liu W, Guo H, Du X, Zhou W, Zhang G, Ding H, Wang G (2012) Cortical vessel imaging and visualization for image guided depth electrode insertion. Comput Med Imag Graph. doi: 10.1016\/j.compmedimag.2012.05.004","DOI":"10.1016\/j.compmedimag.2012.05.004"},{"issue":"6","key":"843_CR34","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.2214\/ajr.143.6.1157","volume":"143","author":"L Axel","year":"1984","unstructured":"Axel L (1984) Blood flow effects in magnetic resonance imaging. Am J Roentgenol 143(6):1157\u20131166","journal-title":"Am J Roentgenol"},{"issue":"1","key":"843_CR35","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1016\/j.media.2010.08.003","volume":"15","author":"C Xiao","year":"2011","unstructured":"Xiao C, Staring M, Shamonin D, Reiber JHC, Stolk J, Stoel BC (2011) A strain energy filter for 3D vessel enhancement with application to pulmonary CT images. Med Image anal 15(1):112\u2013124","journal-title":"Med Image anal"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-013-0843-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-013-0843-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-013-0843-5","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,2,14]],"date-time":"2022-02-14T13:30:30Z","timestamp":1644845430000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-013-0843-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,4,21]]},"references-count":35,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2013,11]]}},"alternative-id":["843"],"URL":"https:\/\/doi.org\/10.1007\/s11548-013-0843-5","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,4,21]]}}}