{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,24]],"date-time":"2026-01-24T00:39:58Z","timestamp":1769215198140,"version":"3.49.0"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2013,10,30]],"date-time":"2013-10-30T00:00:00Z","timestamp":1383091200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2014,7]]},"DOI":"10.1007\/s11548-013-0943-2","type":"journal-article","created":{"date-parts":[[2013,10,29]],"date-time":"2013-10-29T14:12:45Z","timestamp":1383055965000},"page":"617-633","source":"Crossref","is-referenced-by-count":0,"title":["Stent graft visualization and planning tool for endovascular surgery using finite element analysis"],"prefix":"10.1007","volume":"9","author":[{"given":"S.","family":"von Sachsen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B.","family":"Senf","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"O.","family":"Burgert","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"Meixensberger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H. J.","family":"Florek","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"F. W.","family":"Mohr","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C. D.","family":"Etz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2013,10,30]]},"reference":[{"key":"943_CR1","first-page":"123","volume":"137","author":"NL Volodos","year":"1986","unstructured":"Volodos NL, Shekhanin VE, Karpovich IP, Troian VI, Gur\u2019ev IA (1986) A self-fixing synthetic blood vessel endoprosthesis. Vestn Khir Im I I Grek 137:123\u2013125","journal-title":"Vestn Khir Im I I Grek"},{"key":"943_CR2","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1007\/BF02015271","volume":"5","author":"JC Parodi","year":"1991","unstructured":"Parodi JC, Palmaz JC, Barone HD (1991) Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg 5:491\u2013499","journal-title":"Ann Vasc Surg"},{"issue":"26","key":"943_CR3","doi-asserted-by":"crossref","first-page":"1729","DOI":"10.1056\/NEJM199412293312601","volume":"331","author":"MD Dake","year":"1994","unstructured":"Dake MD, Miller DC, Semba CP (1994) Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic aneurysms. N Engl J Med 331(26):1729\u20131734","journal-title":"N Engl J Med"},{"key":"943_CR4","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1583\/1074-6218(1997)004<0362:TYEWMS>2.0.CO;2","volume":"4","author":"WJ Stelter","year":"1997","unstructured":"Stelter WJ, Umscheid T, Ziegler P (1997) Three-year experience with modular stent graft devices for endovascular AAA treatment. J Endovasc surg 4:362\u2013369","journal-title":"J Endovasc surg"},{"key":"943_CR5","unstructured":"Deutsche Gesellschaft f\u00fcr Gef\u00e4\u00dfchirurgie (DGG) (2008) 8. Qualit\u00e4tsmanagement Bauchaortenaneurysma"},{"key":"943_CR6","unstructured":"VASCUTEK Ltd, a TERUMO Company, Anaconda stent graft, http:\/\/www.vascutek.com\/vascutek\/products\/item\/anaconda-aaa-stent-graft-system . Active link, July 2013"},{"key":"943_CR7","doi-asserted-by":"crossref","unstructured":"Kortmann H (2011) Bauchaortenaneurysmen (Kapitel 11). In: Kompaktwissen Gef\u00e4\u00dfchirurgie, B.L.P. Luther (Hrsg.). Springer, Heidelberg, pp 199\u2013219","DOI":"10.1007\/978-3-642-14277-2_11"},{"key":"943_CR8","unstructured":"Rosset A (2012) OsiriX imaging software. http:\/\/www.osirix-viewer.com . Active link, July 2013"},{"key":"943_CR9","unstructured":"Aquarius iNtuition Enterprise (2012) TeraRecon. http:\/\/www.terarecon.com . Active link, July 2013"},{"key":"943_CR10","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1016\/S0021-9290(99)00201-8","volume":"33","author":"ML Raghavan","year":"2000","unstructured":"Raghavan ML, Vorp DA (2000) Toward a biomechanical tool to evaluate rupture potential of abdominal aortic aneurysm: identification of a finite strain constitutive model and valuation of its applicability. J Biomech 33:475\u2013482","journal-title":"J Biomech"},{"key":"943_CR11","unstructured":"Vascops GmbH (\u00d6sterreich), VASCPOS (Sweden). http:\/\/www.vascops.com\/en\/vascops-A4clinics.html . Active link July 2013"},{"key":"943_CR12","doi-asserted-by":"crossref","unstructured":"Molony DS, Broderick S, Callanan A, McGloughlin TM, Walsh MT (2011) Fluid-structure interaction in healthy, diseased and endovascularly treated abdominal aortic aneurysms. Stud Mech Anobiol Tissue Eng Biomater, vol 7, Springer, Berlin, pp. 163\u2013179. doi: 10.1007\/8415_2011_85 . ISBN:978-3-642-18094-1","DOI":"10.1007\/8415_2011_85"},{"key":"943_CR13","first-page":"1728","volume":"23","author":"Z Sun","year":"2008","unstructured":"Sun Z, Chaichana T, Sangworasil M, Tungjitkusolmun S (2008) Computational fluid analysis of blood flow characteristics in abdominal aortic aneurysms treated with suprarenal endovascular grafts. ICBME Proc 23:1728\u20131732","journal-title":"ICBME Proc"},{"key":"943_CR14","doi-asserted-by":"crossref","unstructured":"Figueroa CA, Taylor CA, Yeh V, Chiou AJ, Zarins CK (2009) Effect of curvature on displacement forces acting on aortic endografts: a 3-dimensional computational analysis. J Endovasc Ther 16:284\u2013294","DOI":"10.1583\/08-2667.1"},{"key":"943_CR15","doi-asserted-by":"crossref","unstructured":"Scherer S, Treichel T, Ritter N, Triebel G, Drossel, WG, Burgert O (2011) Surgical stent planning\u2014simulation parameter study for models based on DICOM standards. Int J CARS, 6, 3. Springer, Heidelberg, pp 319\u2013327","DOI":"10.1007\/s11548-010-0511-y"},{"key":"943_CR16","doi-asserted-by":"crossref","unstructured":"de Bock S, de Beule M, de Santis G, Vermassen F, Segers P, Verhegghe B (2011) A simulation tool for virtual stent graft deployment in patient-specific abdominal aortic aneurysms. In: Proceedings of the ASME, summer engineering conference","DOI":"10.1115\/SBC2011-53419"},{"key":"943_CR17","doi-asserted-by":"crossref","unstructured":"von Sachsen S, Etz CD, Mohr FW, Senf B, Neugebauer R, Florek HJ (2011) A method for integrating finite element results in a surgical planning software for evaluating stent graft properties in endovascular surgery. In: IEEE proceedings 4th international conference on biomedical engineering and informatics, Shanghai (China), pp 1349\u20131354. ISBN:978-1-4244-9350-0","DOI":"10.1109\/BMEI.2011.6098637"},{"key":"943_CR18","unstructured":"Gebert de Uhlenbrock (2009) A. Dissertation Technische Universit\u00e4t Hamburg-Harburg, Designanalyse von endovaskul\u00e4ren Aortenprothesen"},{"key":"943_CR19","doi-asserted-by":"crossref","unstructured":"Senf B, von Sachsen S, Neugebauer R, Drossel WG, Florek HJ, Mohr FW, Etz CD (2013) The effect of stent graft oversizing on radial forces considering Nitinol wire behavior and vessel characteristics. J Med Eng (accepted)","DOI":"10.1016\/j.medengphy.2014.07.020"},{"issue":"4","key":"943_CR20","first-page":"211","volume":"4","author":"A Sinha Roy","year":"2007","unstructured":"Sinha Roy A, Westt K, Rontala RS, Greenberg RK, Banerjee RK (2007) In vitro measurement and calculation of drag force on iliac limb stentgraft in a compliant arterial wall model. Mol Cell Biomech 4(4):211\u2013226","journal-title":"Mol Cell Biomech"},{"issue":"1","key":"943_CR21","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1016\/j.medengphy.2010.09.013","volume":"33","author":"TJ Corbett","year":"2011","unstructured":"Corbett TJ, Molony DS, Callanan A, Mc Gloughlin TM (2011) The effect of vessel material properties and pulsatile wall motion on the fixation of a proximal stent of an endovscular graft. Med Eng Phys 33(1):106\u2013111","journal-title":"Med Eng Phys"},{"key":"943_CR22","doi-asserted-by":"crossref","unstructured":"Arko FR, Heikkinen M, Lee ES, Bass A, Alsac JM, Zarins CK (2004) Iliac fixation length and resistance to in-vivo stentgraft displacement. In: Proceedings of the 19. Annual meeting of the western vascular society, vol 41, number 4, pp 664\u2013671. doi: 10.1016\/j.jvs.2004.12.050","DOI":"10.1016\/j.jvs.2004.12.050"},{"key":"943_CR23","doi-asserted-by":"crossref","unstructured":"Kleinstreuer C, Li Z, Basciano CA, Seelecke S, Farber MA (2008) Computational mechanics of Nitinol stent grafts. J Biomech 41:2370\u20132378","DOI":"10.1016\/j.jbiomech.2008.05.032"},{"key":"943_CR24","doi-asserted-by":"crossref","unstructured":"Gao F, Watanabem M, Matsuzawa T (2006) Stress analysis in a layered aortic arch model under pulsatile blood flow. BioMed Eng Online 5. doi: 10.1186\/1475-925X-5-25","DOI":"10.1186\/1475-925X-5-25"},{"key":"943_CR25","doi-asserted-by":"crossref","unstructured":"Holzapfel GA, Sommer G, Regitnig P (2004) Anisotropic mechanical properties of tissue components in human atherosclerotic plaques. J Biomech Eng H 126:657\u2013665. doi: 10.1115\/1.1800557","DOI":"10.1115\/1.1800557"},{"key":"943_CR26","unstructured":"Materialise (2013) Mimics innovation suite. http:\/\/biomedical.materialise.com\/mimics . Active link July 2013"},{"key":"943_CR27","unstructured":"Materialise (2013) 3-matic. http:\/\/biomedical.materialise.com\/3-matic-0 . Active link July 2013"},{"key":"943_CR28","unstructured":"ANSYS, Inc. (2009) ANSYS manual; Version 11"},{"key":"943_CR29","unstructured":"Kitware (2013) The visualization toolkit. http:\/\/www.vtk.org . Active link July 2013"},{"key":"943_CR30","unstructured":"German Cancer Research Center Division of Medical and Biological Informatics Heidelberg (2012) Medical interaction and imaging tool kit (MITK). http:\/\/www.mitk.org\/wiki\/BlueBerry . Active link July 2013"},{"key":"943_CR31","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1583\/1545-1550(2007)14[585:DRTIVD]2.0.CO;2","volume":"14","author":"EH Murphy","year":"2007","unstructured":"Murphy EH, Johnson D, Arko FR (2007) Device-specific resistance to in vivo displacement of stent-grafts implanted with maximum iliac fixation. J Endovasc Ther 14:585\u2013592","journal-title":"J Endovasc Ther"},{"key":"943_CR32","unstructured":"Bosman WMPF, Steenhoven vd, Steenhoven TJ, Su\u00e1rez DR, Hinnen JW, Valstar ER, Hamming JF (2010) The proximal fixation strength of modern EVAR grafts in a short aneurysm neck. An in vitro study. Eur J Vasc Endovasc Surg 39:187\u2013192. doi: 10.1016\/j.ejvs2009.10.019"},{"key":"943_CR33","unstructured":"ISONORM 9241-110 (2013) Ergonomics of human-system interaction\u2014Part 110: dialogue principles. http:\/\/www.iso.org\/iso\/home\/store\/catalogue_tc\/catalogue_detail.htm?csnumber=38009 . Active Link July 2013"},{"key":"943_CR34","doi-asserted-by":"crossref","unstructured":"Pr\u00fcmper J (1997) Der Benutzungsfragebogen ISONORM 9241\/10: Ergebnisse zur Reliabilit\u00e4t und Validit\u00e4t. In Liskkowsky R, Velichkovsky BM, W\u00fcnsschmann W (Hrsg) Software-Ergonomie \u201997-usability engineering: integration von Mensch-Computer-Interaktion und Software-Entwicklung, pp 253\u2013262","DOI":"10.1007\/978-3-322-86782-7_21"},{"key":"943_CR35","unstructured":"Pr\u00fcmper J (2013) ISONORM 9241-110 questionnaire. http:\/\/www.seikumu.de\/de\/dok\/dok-echtbetrieb\/Fragebogen-ISONORM-9241-110-S.pdf . Active link July 2013"},{"key":"943_CR36","unstructured":"Pr\u00fcmper J (2013) ISONORM 9241-110 Questionnaire interpretation matrix. http:\/\/www.seikumu.de\/de\/dok\/dok-echtbetrieb\/Vorlage-Auswertung-ISONORM-Fragebogen.xls . Active link July 2013"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-013-0943-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-013-0943-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-013-0943-2","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,7,31]],"date-time":"2019-07-31T12:30:34Z","timestamp":1564576234000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-013-0943-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,10,30]]},"references-count":36,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2014,7]]}},"alternative-id":["943"],"URL":"https:\/\/doi.org\/10.1007\/s11548-013-0943-2","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,10,30]]}}}