{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,25]],"date-time":"2026-01-25T15:20:16Z","timestamp":1769354416980,"version":"3.49.0"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2013,9,29]],"date-time":"2013-09-29T00:00:00Z","timestamp":1380412800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2014,7]]},"DOI":"10.1007\/s11548-013-0946-z","type":"journal-article","created":{"date-parts":[[2013,9,28]],"date-time":"2013-09-28T03:55:46Z","timestamp":1380340546000},"page":"733-743","source":"Crossref","is-referenced-by-count":22,"title":["Automated implant segmentation in cone-beam CT using edge detection and particle counting"],"prefix":"10.1007","volume":"9","author":[{"given":"Ruben","family":"Pauwels","sequence":"first","affiliation":[]},{"given":"Reinhilde","family":"Jacobs","sequence":"additional","affiliation":[]},{"given":"Hilde","family":"Bosmans","sequence":"additional","affiliation":[]},{"given":"Pisha","family":"Pittayapat","sequence":"additional","affiliation":[]},{"given":"Pasupen","family":"Kosalagood","sequence":"additional","affiliation":[]},{"given":"Onanong","family":"Silkosessak","sequence":"additional","affiliation":[]},{"given":"Soontra","family":"Panmekiate","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2013,9,29]]},"reference":[{"key":"946_CR1","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1111\/j.1834-7819.2011.01657.x","volume":"57","author":"WC Scarfe","year":"2012","unstructured":"Scarfe WC, Li Z, Aboelmaaty W, Scott SA, Farman AG (2012) Maxillofacial cone beam computed tomography: essence, elements and steps to interpretation. Aust Dent J 57:46\u201360","journal-title":"Aust Dent J"},{"key":"946_CR2","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1563\/AAID-JOI-D-09-00080","volume":"36","author":"M Naitoh","year":"2010","unstructured":"Naitoh M, Nabeshima H, Hayashi H, Nakayama T, Kurita K, Ariji E (2010) Postoperative assessment of incisor dental implants using cone-beam computed tomography. J Oral Implantol 36:377\u2013384","journal-title":"J Oral Implantol"},{"key":"946_CR3","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1111\/j.1600-051X.2010.01535.x","volume":"37","author":"N Assche Van","year":"2010","unstructured":"Van Assche N, van Steenberghe D, Quirynen M, Jacobs R (2010) Accuracy assessment of computer-assisted flapless implant placement in partial edentulism. J Clin Periodontol 37:398\u2013403","journal-title":"J Clin Periodontol"},{"key":"946_CR4","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1007\/s11548-011-0556-6","volume":"6","author":"V Wouters","year":"2011","unstructured":"Wouters V, Mollemans W, Schutyser F (2011) Calibrated segmentation of CBCT and CT images for digitization of dental prostheses. Int J Comput Assist Radiol Surg 6:609\u2013616","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"946_CR5","doi-asserted-by":"crossref","unstructured":"Pauwels R, Nackaerts O, Bellaiche N, Stamatakis H, Tsiklakis K, Walker A, Bosmans H, Bogaerts R, Jacobs R, Horner K, The SEDENTEXCT Project Consortium (2013) Variability of dental cone beam CT grey values for density estimations. Br J Radiol 86:20120135","DOI":"10.1259\/bjr.20120135"},{"key":"946_CR6","doi-asserted-by":"crossref","unstructured":"Liu Y, B\u00e4uerle T, Pan L, Dimitrakopoulou-Strauss A, Strauss LG, Heiss C, Schnettler R, Semmler W, Cao L (2012) Calibration of cone beam CT using relative attenuation ratio for quantitative assessment of bone density: a small animal study. Int J Comput Assist Radiol Surg (Epub ahead of print)","DOI":"10.1007\/s11548-012-0803-5"},{"key":"946_CR7","doi-asserted-by":"crossref","unstructured":"Pauwels R, Stamatakis H, Bosmans H, Bogaerts R, Jacobs R, Horner K, Tsiklakis K, The SEDENTEXCT Project Consortium (2013) Quantification of metal artefacts on cone beam computed tomography images. Clin Oral Implants Res 24:94\u201399","DOI":"10.1111\/j.1600-0501.2011.02382.x"},{"key":"946_CR8","doi-asserted-by":"crossref","unstructured":"Schulze R, Heil U, Gro $${\\upbeta }$$ \u03b2 D, Bruellmann D, Dranischnikow E, Schwanecke U, Schoemer E (2011) Artefacts in CBCT: a review. Dentomaxillofac Radiol 40:265\u2013273","DOI":"10.1259\/dmfr\/30642039"},{"key":"946_CR9","doi-asserted-by":"crossref","unstructured":"Pauwels R, Stamatakis H, Manousaridis G, Walker A, Michielsen K, Bosmans H, Bogaerts R, Jacobs R, Horner K, Tsiklakis K, The SEDENTEXCT Project Consortium (2011) Development and applicability of a quality control phantom for dental cone-beam CT. J Appl Clin Med Phys 12:245\u2013260","DOI":"10.1120\/jacmp.v12i4.3478"},{"key":"946_CR10","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1097\/ID.0b013e31829afac0","volume":"22","author":"E Mijiritsky","year":"2013","unstructured":"Mijiritsky E, Mazor Z, Lorean A, Levin L (2013) Implant diameter and length influence on survival: interim results during the first 2 years of function of implants by a single manufacturer. Implant Dent 22:394\u2013398","journal-title":"Implant Dent"},{"key":"946_CR11","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1016\/j.tripleo.2005.10.039","volume":"102","author":"M Loubele","year":"2006","unstructured":"Loubele M, Maes F, Schutyser F, Marchal G, Jacobs R, Suetens P (2006) Assessment of bone segmentation quality of cone-beam CT versus multislice spiral CT: a pilot study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 102:225\u2013234","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"946_CR12","doi-asserted-by":"crossref","first-page":"160","DOI":"10.2319\/121608-639.1","volume":"80","author":"Y Liu","year":"2010","unstructured":"Liu Y, Olszewski R, Alexandroni ES, Enciso R, Xu T, Mah JK (2010) The validity of in vivo tooth volume determinations from cone-beam computed tomography. Angle Orthod 80:160\u2013166","journal-title":"Angle Orthod"},{"key":"946_CR13","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1007\/s11548-006-0050-8","volume":"1","author":"H Shi","year":"2006","unstructured":"Shi H, Scarfe WC, Farman AG (2006) Upper airway segmentation and dimensions estimation from cone-beam CT image datasets. Int J Comput Assist Radiol Surg 1:177\u2013186","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"946_CR14","doi-asserted-by":"crossref","first-page":"2275","DOI":"10.1118\/1.3566016","volume":"38","author":"M Yazdi","year":"2011","unstructured":"Yazdi M, Lari MA, Bernier G, Beaulieu L (2011) An opposite view data replacement approach for reducing artifacts due to metallic dental objects. Med Phys 38:2275\u20132281","journal-title":"Med Phys"},{"key":"946_CR15","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1097\/RLI.0b013e3182532f17","volume":"47","author":"MM Lell","year":"2012","unstructured":"Lell MM, Meyer E, Kuefner MA, May MS, Raupach R, Uder M, Kachelriess M (2012) Normalized metal artifact reduction in head and neck computed tomography. Invest Radiol 47:415\u2013421","journal-title":"Invest Radiol"},{"key":"946_CR16","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1259\/dmfr\/25260548","volume":"40","author":"S Tohnak","year":"2011","unstructured":"Tohnak S, Mehnert AJ, Mahoney M, Crozier S (2011) Dental CT metal artefact reduction based on sequential substitution. Dentomaxillofac Radiol 40:184\u2013190","journal-title":"Dentomaxillofac Radiol"},{"key":"946_CR17","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1007\/s00784-012-0698-0","volume":"17","author":"P Pittayapat","year":"2013","unstructured":"Pittayapat P, Galiti D, Huang Y, Dreesen K, Schreurs M, Souza PC, Rubira-Bullen IR, Westphalen FH, Pauwels R, Kalema G, Willems G, Jacobs R (2013) An in vitro comparison of subjective image quality of panoramic views acquired via 2D or 3D imaging. Clin Oral Investig 17:293\u2013300","journal-title":"Clin Oral Investig"},{"key":"946_CR18","doi-asserted-by":"crossref","unstructured":"Pauwels R, Beinsberger J, Stamatakis H, Tsiklakis K, Walker A, Bosmans H, Bogaerts R, Jacobs R, Horner K, The SEDENTEXCT Project Consortium (2012) Comparison of spatial and contrast resolution for cone-beam computed tomography scanners. Oral Surg Oral Med Oral Pathol Oral Radiol 114:127\u2013135","DOI":"10.1016\/j.oooo.2012.01.020"},{"key":"946_CR19","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1111\/j.1600-0501.2008.01677.x","volume":"20","author":"Y Hua","year":"2009","unstructured":"Hua Y, Nackaerts O, Duyck J, Maes F, Jacobs R (2009) Bone quality assessment based on cone beam computed tomography imaging. Clin Oral Implants Res 20:767\u2013771","journal-title":"Clin Oral Implants Res"},{"key":"946_CR20","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1016\/j.jcms.2010.10.002","volume":"39","author":"B Hohlweg-Majert","year":"2011","unstructured":"Hohlweg-Majert B, Metzger MC, Kummer T, Schulze D (2011) Morphometric analysis\u2014cone beam computed tomography to predict bone quality and quantity. J Craniomaxillofac Surg 39:330\u2013334","journal-title":"J Craniomaxillofac Surg"},{"key":"946_CR21","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1259\/dmfr\/80899839","volume":"41","author":"BB Bechara","year":"2012","unstructured":"Bechara BB, Moore WS, McMahan CA, Noujeim M (2012) Metal artefact reduction with cone beam CT: an in vitro study. Dentomaxillofac Radiol 41:248\u2013253","journal-title":"Dentomaxillofac Radiol"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-013-0946-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-013-0946-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-013-0946-z","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,7,26]],"date-time":"2019-07-26T15:12:46Z","timestamp":1564153966000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-013-0946-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,9,29]]},"references-count":21,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2014,7]]}},"alternative-id":["946"],"URL":"https:\/\/doi.org\/10.1007\/s11548-013-0946-z","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,9,29]]}}}